Page 1
F&eIT Series AC-DC Power Supply Unit
POW-AD22GY or POW-AD13GY
User’s Manual
CONTEC CO.,LTD.
Copyright
- Copyright 2001 CONTEC CO., LTD. ALL RIGHTS RESERVED. No part of this document may be copied or reproduced in any form or by any means without prior written consent of CONTEC CO., LTD.
- CONTEC CO., LTD. makes no commitment to update or keep current the information contained in this document. The inf o r mation in th is d ocument is subject to chang e w ithou t noti ce.
- All relevant issues have been considered in the preparation of this document. Should you notice an omission or any questionable item in this document, please feel free to notify CONTEC CO., LTD.
- Regardless of the foregoing statement, CONTEC assumes no responsibility for any errors that may appear in this document or for any resu lts of us ing th e product.
- F&eIT is a registered trademark of CONTEC CO., LTD. Other company and product names mentioned herein are generally trademarks or registered trademarks of their respective owners.
Trademarks
- All company and product names that are referred to in this manual are generally trademarks or registered trad e.
Handling Precautions
CAUTION
- This power supply is dedicated to the F&eIT. Do not use for the other devices.
- Do not use or store the equipment in a hot or cold place, or in a place that is subject to severe temperature changes. (Operating temperature range: 0 - 50°C)
- Do not use or store the equipm ent i n a place s ubject t o direct sunlight or near a heating device, such as a stove.
- Do not use or store the equipment in a dusty or humid place. (Operating humidity range: 10 - 90%RH, No condensation)
- As this product contains precision electronic components, do not use or store in environments subject to shock or vibration.
- Do not use or store the product near equipment generating a strong magnetic field or radio waves.
- If you notice any strange odor or overheating, please unplug the power cord immediately.
- In the event of an abnormal condition or malfunction, please consult the dealer from whom the equipment was purchased.
1
POW-AD22GY, POW-AD13GY
Page 2
POW-AD22GY, POW-AD13GY User’s Manual
- To avoid electric shock, please do not touch the system with a wet hand.
- Do not modify the unit. CONTEC will bear no responsibility for any problems, etc., resulting from modifying this unit.
- Do not open the unit casing. CONT EC will discla im any responsibi lity for equipment whose casing has been opened.
Product Configuration
- System unit...1 - AC Power Supply input connector plug...1
- User’s Manual...1 - DC Power Supply output connector plug...2
About the POW-AD22GY or POW-AD13GY
The POW-A D22G Y o r P O W-AD 1 3 G Y is a co m pact power supply unit designed to supply DC power t o the F&e IT series of pr oduc ts. This AC-DC power supply unit is carrying out the standard equipment of the DIN rail attachment mechanism to the main part like other products of this series, and can install it simply and smartly. AC input can prepare 85 - 132V (POW-AD13GY) and wide-range 85 - 264V (POW-AD22GY), and can unite and choose them as a system. In addition, a system can be easily built combining F&eIT series product.
FCC PART 15 Class A No ti ce
NOTE
This equipment has been tested and found to comply with the lim its for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference at his own expense.
WARNING TO USER
Change or modifications not expressly approved the manufacturer can void the user's authority to operate this equipment.
POW-AD22GY, POW-AD13GY
2
Page 3
POW-AD22GY, POW-AD13GY User’s Manual
Compliance Requirements
The low voltage directives require that devices operating from power supplies in the range 50 - 1000 VAC or 75 - 1500 VAC observe necessary safety precautions.
The following describ es th e main po ints to no te so th at inst all ati on s usin g the POW-AD22GY can comply with the low voltage directives.
Although this information has been prepared to the best of our ability based on the requirements, standards, and other stipulations contained in the regulations obtained by CONTEC, we provide no guarantee that equipment manufactured based on this information wi ll comply with the above directive. Ultimate responsibility for determining how to comply with the low voltage directive and how to confirm compliance is the responsibility of the equipment manufacturer.
POW-AD22GY is an open-type device (a device designed to be housed inside other equipment) and must always be mounted inside a control panel according to standard EN60950. To provide electrical shock protection for people such as operators who do not have the necessary level of electrical knowledge, the control panel must include the following precautionary measures (Installation category:2).
(1) Electric shock protection
(a) Lock the control panel to ensure that it can only be opened by persons with sufficient knowledge
and training on electrical equipment.
(b) Incorporate a mechanism so that opening the control panel automatically isolates the power
supply. (2) Water and dust proofing The control panel is dust- and water-proof. If dust-proofing or water-proofing is made inadequate, insulation may deteriorate increasing the risk of insulation failure. T he insulation on the POW-AD22GY is designed to deal with pollution degree 2 and therefore the unit should only be used in environments with pollution degree 2 or better.
Pollution degree 1: Dry environment with no conductive dust or other contamination. Pollution degree 2: Environment in which conductive dust or othe r conta mination does not nor mally
occur, but where conductive contamination may occur from time to time due to accumulation of dust or similar. Typically the environment in an IP54 equivalent control panel in a factory control room or factory floor.
Pollution degree 3: Environment in which conductive dust or other contamination does occur and
where conduction may occur due to accumulation of dust or similar. Typically a factory floor environment.
Pollution degree 4: Environment in which conductive contamination such as rain or snow is always
present. An outdoor environment. As described above, if a POW-AD22GY is housed in an IP54 equivalent control panel, contamination level 2 can be achieved. (3) Installation Requirements
(a) Build in this power supply according to standard EN60950 which is a built-in power supply. (b) Installation category:2 (Pollution Degree 2) (c) The protection earth point is FG pin of 100 - 240VAC connector in front of the case. Ground this
pin to the earth with the cable.
3
POW-AD22GY, POW-AD13GY
Page 4
Nomenclature
POW-AD22GY, POW-AD13GY User’s Manual
Connector
Name Function
2-piece power input connector (detachable).
DC
A dedicated plug as a standard item.
input port
Screw-in type cable connection . 2-piece power output connector (detachable)
DC output
A dedicated plug as a standard item
port
Screw-in type cable connection
LED Indicator
Name Function Indication
Power LED Power: green
ON: DC output on OFF: DC output off
POW-AD22GY, POW-AD13GY
4
Page 5
POW-AD22GY, POW-AD13GY User’s Manual
System Reference
Specifications2
POW-AD22GY POW-AD13GY
Input
Output
Auxiliary functions
Other functions
Voltage AC85 - 264V AC85 - 132V Current ACIN 100V:0.3A(Typ. Io=100%)
Frequency 47 - 440Hz Rush current ACIN 100V:15A(Typ. Io=100%)
Leakage current 0.5mA(Max.) (60Hz,IEC60950)
Efficiency 74%(Typ.) 75%(Typ.) Rated voltage 5.0V ±5% Rated current 2.0A(Max.) 3.0A(Max.) Static input fluctuations 20mV(Max.) Static load fluctuations 40mV(Max.) Ripple noise 200mVp-p(Max.) 120mVp-p(Max.) Ambient temperature
fluctuations Time-dependent
drift
warm-up time 700ms(Max.) (ACIN 85 V, I o=100 %) 200ms(Max.) (ACIN 85V, Io=100%) holding time 8ms(Typ.)(ACIN 100V, Io=100%)
Overcurrent protection
Overvoltage protection Operates at 115%(Min.) of rated
FG pin An FG terminal is provided on the power I/O connectors External dimensions (mm) 52.4(W) x 64.7 (D) x 94 .0(H) (ex clusive of any protrusions) Cooling method Natural air cooling Service life It is seven years (Io=75%) at the circumference temperature of 25ºC. Weight of the system
unit Installation method
ACIN 200V:0.2A(Typ. Io=100%)
ACIN 200V:30A(Typ. Io=100%)
50mV(Max.)(0 - 55ºC)
20mV(Max.) (It is change of the 3 0 minute - 8 hours after input voltage impression in the circumference temperature of 25ºC, and rated input and output)
16ms(Typ.)(ACIN 200V, Io=100%) Operates at 125%(Min.) of rated
current; auto-reverting
voltage (Zener diode clamp)
110g 150g
One-touch attachment to a 35mm DIN rail The mounting mechanism is provided on the system unit as a standard item.
SpecificationsItem
ACIN 100V:0.4A(Typ. Io=100%)
ACIN 100V:25A(Typ. Io=100%)
0.18mA(Max.) (60Hz,IEC60950)
±0mV(Max.) (It is change of the 30 minute - 8 hours after input voltage impression in the circumference temperature of 25ºC, and rated input and output)
10ms(Typ.) (ACIN 85V, Io=100 %)
Operates at 105% of rated current; auto-reverting
---
5
POW-AD22GY, POW-AD13GY
Page 6
POW-AD22GY, POW-AD13GY User’s Manual
Installation Environment Requirements
Parameter Requirement descriptio n
Ambient temperature 0 - 50ºC Ambient Humidity 10 - 90%RH (No condensation) Floating dust particles Not to be excessive Corrosive gases None Noise
Line-noise AC line/2kV, Signal line/1kV (IEC1000-4-4Level 3, EN61000 -4-4Leve l 3)
immunity
Static electricity resistance
Sweep resistance
resistance
Contact discharge/4kV (IEC1000-4-2Level 2, EN61000-4-2Level 2) Atmospheric discharge/8kV (IEC1000-4-2Level 3, EN61000-4-2Level 3) 10 - 57Hz/semi-amplitude 0.15mm, 57 - 150Hz/2.0GVibration 80minutes each in X, Y, and Z directions
(JIS C0040-compliant, IEC68-2-6-compliant)
Impact resistance 15G, half-sine shock for 11ms in X, Y, and Z directions
(JIS C004-compliant, IEC68-2-27-compliant ) Grounding Class D grounding (previous class 3 grounding) Installation location Installing to the DIN rail (the control boards,etc.) as the power supply dedicated to
the F&eIT.
I/O Connectors
Item Description
Board connector 5.08mm pitch 12.0A rated current
Input
Compatible plug Laterally operable screw-in type
(MSTB2,5/3-STF-5,08 made by PHOENIX CONTACT Corp.)
Compatible wires AWG 24 - 12 12.0A rated current Board connector 3.5mm pitch 8.0A rated current
Output
Applicable plug Laterally operable screw-in type
(MC1,5/3-ST-3,5 made by PHOENIX CONTACT Corp.)
Applicable wires AWG 28 - 16 8.0A rated current
External Dimensions
(1.2)
14
31.5
POWER
Vo+
5VDC
Vo­FG
Vo+ Vo-
5VDC
FG
85-132VAC
AC(N)
AC(L)
FG
POW-AD13
52.4
POW-AD22GY, POW-AD13GY
14.035.045.0
94.0
64.7
4.0
[mm]
6
Page 7
POW-AD22GY, POW-AD13GY User’s Manual
Installation Method
Mounting the AC-DC Power Supply Unit on the DIN Rail
Mounting procedure (1) Pushing the fixing hook with a flat-blade
screwdriver renders it into a lock-enabled condition.
35mm DIN rail
Press here to lift the fixing hook.
(2) Hook th e AC-DC power supply un it fro m
the upper part of the DIN rail, and press the lower part of the unit against the DIN rail.
Side view
(3) The fixing hook is automatically locked,
and the module can be mounted in one­touch.
Removal procedure (1) Lower the fixing hook for the unit to unlock
it.
35mm DIN rail
(2) With the fixing hook unlocked, pull th e
lower part of the uni t toward you.
Side view
(3) By lifting the unit, you can easily remove it
from the DIN rail.
Fixing hook
Side view
7
POW-AD22GY, POW-AD13GY
Side view
Page 8
POW-AD22GY, POW-AD13GY User’s Manual
Connection Method
Connecting the I/O cables to the AC-DC power supply unit
Cables are connected to the AC-DC power supply unit by means of detachable connectors that are provided as standard items.
(Input unit: compatible cables: AWG 24 - 12. Tightening torque: 0.5 - 0.6Nm) (Output unit: compatible cables: AWG 28 - 16. Tightening torque: 0.22 - 0.25Nm) The AC-DC power supply unit and F&eIT Series product can be cable-connected using th e detachable
connector that is provided on either the unit face or the modulet face (compatible cables: AWG 28 - 16). Please use the clothing of a cable, turning to it about about 7mm.
CAUTION
Because the AC-DC power supply unit generates heat, a minimum spacing of 2.0 cm should be provided between the POW-AD22GY or PO W-AD13GY and any adjoining units, and care should be taken so that the ventilation holes are not covered.
List of Options
FAN Unit
- FAN-FIT FAN Unit For 52.4mm-width unit or module
Copyright 2001 CONTEC CO., LTD. ALL RIGHTS RESERVED.
CONTEC CO., LTD. December 2005 Edition
3-9-31, Himesato, Nishiyodogawa-ku, Osaka 555-0025, Japan Japanese http://www.contec.co.jp/ English http://www.contec.com/ A-40-623 (LZN6031) Chinese http://www.contec.com.cn/ 12162005_rev5 [11272001] No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD.
Loading...