Contec IPC-DT/L40S(PC)T, IPC-DT/H40X(PC)T User Manual

Page 1
IPC Series
FLAT PANEL DISPLAY For PanelLink
IPC-DT/L40S(PC)T IPC-DT/H40X(PC)T
User’s Manual
CONTEC CO.,LTD.
Page 2

Copyright

Copyright 2001 CONTEC CO., LTD. ALL RIGHTS RESERVED No part of this document may be copied or reproduced in any form
by any means without prior written consent of CONTEC CO., LTD.
CONTEC CO., LTD. makes no commitment to update or keep current the information contained in this document. The information in this document is subject to change without notice.
All relevant issues have been considered in the preparation of this document. Should you notice an omission or any questionable item in this document, please feel free to notify CONTEC CO., LTD.
Regardless of the foregoing statement, CONTEC assumes no responsibility for any errors that may appear in this document or for results obtained by the user as a result of using this product.

Trademarks

MS, Microsoft, Windows, Windows NT and MS-DOS are trademarks of Microsoft Corporation. Other brand and product names are trademarks of their respective holder.
User’s Manual
i
Page 3

Table of Contents

Copyright...........................................................................i
Trademarks........................................................................ i
Table of Contents.............................................................. ii
1.Introduction.......................................................................1
Features........................................................................ 1
Limited One-Year Warranty........................................ 2
How to Obtain Service................................................. 2
Liability ........................................................................ 2
Handling Precautions.................................................. 3
2.Specifications.....................................................................7
Function Specifications.................................................... 7
General Specifications ..................................................... 8
Optical Display Specifications......................................... 9
3.Outside Dimensions and Part Names............................11
Outside Dimensions........................................................11
Part Names..................................................................... 14
4.Setting the Display .........................................................15
Setting the DIP switch................................................... 15
Specifications of Remote Control Cable Connector...... 16
Connector application example................................. 16
5.Installation Procedure ....................................................17
6.Connection to the Host Computer and Power Supply ...19
Setting up the Host Computer....................................... 19
Connection Example ...................................................... 23
Power Supply.................................................................. 24
Panel Link Connector Specifications ............................ 25
7.Touch Panel..................................................................... 27
8.Options ............................................................................29
ii
User’s Manual
Page 4

1. Introduction

The IPC-DT/L40S(PC)T and IPC-DT/H40X(PC)T are TFT color liquid crystal displays (LCDs) to be used with host computers such as the CONTEC IPC Series and SBCs (s in g le -boa rd co mp u ters).

Features

- Full-bright, wide-angle-of-visibility type of liquid crystals capable of displaying up to 262,144 colors
- Touch panel enables mouse-style keyboard-less operation .
- Panel Link Interface allowing a cable of up to 5 m in length to be used
- Thin panel unit has a mounting depth of only 38mm (when input directly to 5VDC terminal)
- Back-mounted, dedicated power supply unit [IPC-POA1 00D] available as an option, enabling the LCD to be used with an AC power supply
- Equipped with a connector for remote control to get the full benefit of the LCD
- Front structure with IP65-compliant ingress protection
* For the host computer to be used with the display or its options,
contact your local CONTEC branch or sales office.
1. Introduction
User’s Manual
1
Page 5
1. Introduction

Limited One-Year Warranty

CONTEC Products are warranted by CONTEC CO., LTD. to be free from defects in material and workmanship for up to one year from the date of purchase by the original purchaser.
Repair will be free of charge only when this device is returned freight prepaid with a copy of the origina l invoic e and a Return Merchandise Authorization to the distributor or the CONTEC group office, from which it was purchased.
This warranty is not applicable for scratches or normal wear, but only for the electronic circuitry and original products. The warranty is not applicable if the device has been tampered with or damaged through abuse, mistreatment, neglect, or unreasonable use, or if the original invoice is not included, in which case repairs will be considered beyond the warranty policy.

How to Obtain Service

For replacement or repair, return the device freight prepaid, with a copy of the original invoice. Please obtain a Return Merchandise Authorization Number (RMA) from the CONTEC group office where you purchased before returning any product.
* No product will be accepted by CONTEC group without the
RMA number.

Liability

The obligation of the warrantor is solely to repair or replace the product. In no event will the warrantor be liable for any incidental or consequential damages due to such defect or consequences that arise from inexperienced usage, misuse, or malfunction of this device.
2
User’s Manual
Page 6

Handling Precautions

Take the following precautions when handling this bo ard.
- This display is made of the precise electric parts, so do not use or store it in the vicinity of impulse or vibration.
- Do not use or store the product in a location exposed to extremely high or low temperature or susceptible to rapid temperature changes. Example: - Exposure to direct sun
- In the vicinity of a heat source
- There are switches and jumpers on the board that need to be set in advance. Be sure to check these before installing to the expansion slot. Only set the switches and jumpers on the board to the specified settings. Otherwise, the product may cause a failure.
- Do not use the product in extremely humid or dusty locations.
- This product is not intended for use in aerospace, space, nuclear power, medical equipment, or other applications that require a very high level of reliability. Do not use the product in such applications.
- If you utilize this product in such usages where high reliability and safety are required as on the trains, vessels, automotives or crime- or disaster-prevention devices, contact your retailer.
- Do not use touch panel key operations to initiate actions where there is a risk of loss of life or serious injury. Ensure that the system design can handle the case when a key is pressed by mistake.
- Do not use any sharp-pointed object such as a mechanical pencil to touch the touch panel. Doing so may scratch the touch panel, resulting in malfunctions.
- Do not subject the touch panel to shock as doing so may break it.
- Do not modify the product. CONTEC will bear no responsibility for any problems, etc., resulting from modifying this product.
- Use the power supply intended for use with this unit whenever possible. If using a power supply other than the intended power supply, ensure that it satisfies the required voltage and maximum current ratings.
- Never disconnect the display cable when the ho st computer is turned on. To avoid damage to the display, turn off the computer before inserting or disconnecting the display cable.
- In the event of failure or abnormality, contact your retailer.
1. Introduction
User’s Manual
3
Page 7
1. Introduction
- When the surface or frame of the touch panel has become dirty, wipe it with neutral detergent. Do not wipe the touch panel with thinner, alcohol, ammonia, or a strong chlorinated solvent. Use a protective sheet (available as an option) if the touch panel is used where it can easily collect dust and dirt.
- This display does not support the OS other than the following OS. Windows 2000 Professional, Windows NT 4.0 Workstation, Windows 98 Second Edition
- A characteristic of analog touch panels is that the detected position may vary due to changes in the ambient environment (temperature and humidity) and chan g es in re sis tan c e valu es ov er time. In such cases, the touch panel should be recalibrated and the calibration data updated.
- LCD display may have some pixels being dropped (bright and black spots) below a certain threshold. Note that this is not a failure or a defect.
- Regular maintenance is necessary for the backlight on the touch panel and the display for the longevity parts.
Burn-in on TFT Display
- "Burn-in" may occur if the same display is retained for a long time. Avoid this by periodically switching the display so that the same display is not maintained for a long time.
* Burn-In---Phenomenon characterized by a TFT display as a result
of long-time display of the same screen where a shadow-like trace persists because electric charge remains in the LCD element even after the patterns are changed.
- Component Life
(1) backlight--- The operating lifetime of the backlight is at least
seven years. (Brightness reduced to 50% of original, assuming continuous operation at 25 degrees centigrade, Utilization rates 18 hours/one)
(2)Touch panel--- The operating lifetime of the touch panel is at
least 1 million touches (as tested by mechanical touching under 300g of force at a rate of two presses per second).
* CONTEC accepts your request for replacing each consumable in
the PANECON-PC as a request forrepair (at an additional cost). Contact your local retailer or CONTEC sales office.
4
User’s Manual
Page 8
FCC PART 15 Class A Notice
NOTE
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference at his own expense.
WARNING TO USER
Change or modifications not expressly approved the manufacturer can void the user's authority to operate this equipment.
1. Introduction
User’s Manual
5
Page 9
1. Introduction
6
User’s Manual
Page 10
2. Specifications Function Specifications
Table 2.1. Function Specifications
Item
Assembly type Panel mounted Screen size 12.1 inches 15 inches Number of pixels 800 x 600 dots 1024 x 768 dots Display type TFT color LCD Number of colors 262,144 colors Brightness control Provided by software and hardware
Backlight control Provided by software and hardware
Cable length 2m or 5m (use the special-purpose display cable sold separately.) LCD interface 20-pin MDR connector (Panel Link Interface used) *1 Power supply interface 4-pin nylon connector for +5 VDC power supply
Resolution 4096 x 4096 (Emulated in 800 x 600) 4096 x 4096 (Emulated in 1024 x 768)
Touch panel
Detection method Resistive-layer analog method Touch life expectancy The operating lifetime of the touch panel is at least 1 million touches
Touch panel interface 20-pin MDR connector on the back (shared with display signals)
Power consumption 3.3A Max. at +5 VDC±5% 4.0A Max. at +5 VDC±5%
IPC-DT/L40S(PC)T IPC-DT/H40X(PC)T
(Remote control cable connector on the back)
(Remote control cable connector on the back)
(Input at 85 to 264 VAC is enabled by using the back-mounted, optional power supply unit [IPC-POA100D].)
(as tested by mechanical touching under 300g of force at a rate of two presses per second)
Specification

2. Specifications

*1 : When used for output to the LCD, the CONTEC IPC or SBC series requires a converter such as the LCD signal conversion unit [ADPLNK(PC)H] depending on the model of the host. Check this out before purchase.
User’s Manual
7
Page 11
2. Specifications

General Specifications

Table 2.2. General Specifications
Condition
Environment
Ambient operating temperature 0 - 50°C Ambient storage temperature -10 - 60°C Ambient humidity 10 - 90%RH (No condensation ) Floating dust Normal Corrosive gas None Noise
resistance
Vibration resistance
Shock resista n c e 10 G in the X/Y/Z d irections for 11 ms; Ha l f-sine wave
Structure
Major dimensions (mm) 370(W) x 40.4(D) x 307(H) 428(W) x 40.4(D) x 336(H) Panel cut dimensions (mm) 344±0.5(W) x 281± 0 .5(H)
Weight About 4.0 kg (*2) About 5.0 kg (*2) Ingress protection Front part conforming to IP65
*2: The weight includes neither cables nor the optional power supply.
Line noise AC line: 2 kV, Signal line: 1 kV
Electrostatic withstanding voltages
Sweep durability 10 - 50 Hz/Single-side amplitude or 0.15 mm
Fixed-vibration durability
IPC-DT/L40S(PC)T IPC-DT/H40X(PC)T
(IEC1000-4-4Level3, EN61000-4-4Level3) (Host: IPC-BX/M600(PCW), Power supply: IPC-POA100D)
Contact: 4 kV (IEC1000-4-2 Level 2, EN61000-4-2 Level 2) Airborne: 8 kV (IEC1000-4-2 Level 3, EN61000-4-2 Level 3) (Host: IPC-BX/M600(PCW), Power supply: IPC-POA100D)
50 - 500 Hz/2.0 G in the X/Y/Z directions for 23 mi n ut es ea ch (Conforming to JIS C0040 and IEC68-2-6)
16.7 Hz/2 G in the X/Y/Z directions for 30 minutes each (Conforming to JIS C0040 and IEC68-2-6)
(Conforming to JIS C0041 and IEC68-2-27)
(12 stud holes are required on the periphery.)
Specification
398±0.5(W) x 306±0.5(H) (12 stud holes are required on the periphery.)
8
User’s Manual
Page 12

Optical Display Specifications

Table 2.3. Optical Display Specifications
Item Condition
Visual angle (Up/Down)
Visual angle (Right/Left)
Surface brightness (at center) *1 *1 Surface brightness is a numerical value in a display simple substance. The brightness that let the
touch panel pass serves as about 77% of the above-mentioned numerical value.
Left ( φ =
-
90o )
( θ = 0
CR10
o
φ = 180° 50deg 50deg
φ = 0° 70deg 60deg
Display in
monochrome
φ = +90° 70deg 75deg
φ= -90°
Display in white 350cd/m2 (Typ.) 250cd/m2 (Typ.)
Measurement direction
Z
)
θ
Top
o
)
( φ = 180
2. Specifications
Specifications
IPC-DT/L40S(PC)T IPC-DT/H40X(PC)T
70deg 75deg
Note!
User’s Manual
X
Bottom ( φ = 0
φ
o
)
Y
Module
Right ( φ = 90
o
)
Figure 2.1. Viewing Range Definition
The above optical specification data shows optical characteristics of the liquid crystal in the display; the data does not represent the actual view on the display or its viewing angles.
9
Page 13
2. Specifications
10
User’s Manual
Page 14

3. Outside Dimensions and Part Names

3. Outside Dimensions and Part Names Outside Dimensions
IPC-DT/L40S(PC)T
12-M4 STUD
370
251
99.7589.75
307
2.438
13
98 9898
279
Figure 3.1. Out side Dimensions of Main Unit
(IPC-DT/L40S(PC)T)
IPC-DT/H40X(PC)T
12-M4 STUD
428
310.1
13
38 2.4
106
4-M4 TAP (Maximum tapping length : 7mm)
119 119 119
100
137 137 137
342
100
396
100
[mm]
236.7
336
7
User’s Manual
304
100
7
CONTEC
4-M4 TAP (Maximum tapping length:4mm)
[mm]
302
157.5
254
138
4-M4 TAP (Including the mate) Maximum tapping length:4mm)
107106
4-M4 TAP (Including the mate) Maximum tapping length:4mm)
Figure 3.2. Out side Dimensions of Main Unit
(IPC-DT/H40X(PC)T)
11
Page 15
3. Outside Dimensions and Part Names
IPC-DT/L40S(PC)T with IPC-POA100D (power supply unit)
119 119 119
342
12-M4 STUD
58
13
2.438 370
98 9898
279
17
Figure 3.3. Dimensions of IPC-DT/L40S(PC)T with
IPC-DT/H40X(PC)T with IPC-POA100D (power supply unit)
137 137 137
107 106106
304
280
14048.5(85)
IPC-POA100D
396
67
12-M4 STUD
58
13
67
307
[mm]
2.438
336
428
167113
(85)
17
16721.5
Figure 3.4. Dimensions of IPC-DT/H40X(PC)T with
IPC-POA100D
12
[mm]
User’s Manual
Page 16
45mm
20mm
Figure 3.5. Cable Bend Dimension
3. Outside Dimensions and Part Names
User’s Manual
13
Page 17
3. Outside Dimensions and Part Names

Part Names

Panel Link connector
Remoto control cable connector
DIP-SW
5VDC power supply connecotr
Figure 3.6. Pa rt Names (IPC -D T/L40S(PC ) T and
IPC-DT/H40X(PC)T)
Touch panel over liquid crystals
Power LED
14
User’s Manual
Page 18

4. Setting the Display

Be sure to check the following settings before using the display.

Setting the DIP switch

The display has a DIP switch (an array of built-in switches) on the back. For normal use of the display, leave all of the built-in switches at the OFF positions (as factory-set). The table below shows the functions of the built-in switches.
1234
ON
Figure 4.1. DIP Switch Table 4.1. DIP Switch Settings
No. ON/OFF setting Function
OFF (Factory setting) Enable the display built-in buzzer to sound upon a touch on the
1
touch panel. (The buzzer ON/OFF setting can also be controlled by driver software.)
ON Disable the display built-in buzzer from sounding upon a touch on
the touch panel. (The buzzer ON/OFF setting can also be
controlled by driver software.) OFF (Factory setting) Use a host other than below.2 ON Use an SBC board PC-686C(PC)H-LV , -LVS
IPC-BX/M620(PCW) Series, or IPC-BX/M630(PCI) Series. OFF (Factory setting) No function3 ON No function OFF (Factory setting) No function4 ON No function
4. Setting the Display
Notes!
User’s Manual
- The buzzer is disabled by setting the DIP switch (built-in switch No. 1 to ON).
- Set built-in switch No. 2 depending on the host product to be used with the display.
15
Page 19
4. Setting the Display
Specifications of Remote Control Cable
Connector
The display has the remote control cable connector on the back. Given below are the pin assignments on the connector and an example of using it.
Table 4.2. Remote Control Cable Connector
Connector type
Model
Pin No.
1 2 3 4 5 6
*1 : The backlight remains off while the backlight ON/OFF signal has the GND level.

Connector application example

Cable connector (Side type)
S6B-XH-A(LF)(SN)(mfd. by JST)
1 2 3 4 5 6
Signal name Brightness UP GND Brightness DOWN GND Backlight ON/OFF *1 GND
Pushbutton switches (SW1, SW2)
1 2 3 4 5 6
Connector model: XHP-6 (JST)
SW1
SW2
SW3
ON/OFF switch (SW3)
Figure 4.2. Connector Application Example
Notes!
- Applying a GND-level voltage to the brightness UP or DOWN signal increases or decreases the brightness.
- The brightness remains unchanged if the two signals (brightness UP and DOWN signals) are input at the same time.
- The remote control cable is not bundled with this prod uct.
16
User’s Manual
Page 20

5. Installation Procedure

(1) Cut a panel in the following dimensions for installing the
display. The four corners of the solid-line rectangle define the panel cut dimensions. The holes (12) on dashed lines represent stud holes.
5. Installation Procedure
119 119119
281
98 9898
12 φ 05
344
Figure 5.1. Display Mounting Position
(IPC-DT/L40S(PC)T)
137 137137
306
398
[mm]
User’s Manual
106 106107
12 φ 05
[mm]
Figure 5.2. Display Mounting Position
(IPC-DT/H40X(PC)T)
17
Page 21
5. Installation Procedure
(2) Insert the supplied gasket between the panel and the display,
Panel
Figure 5.3. Assembling Method
Note!
The panel must be up to 10 mm in thickness.
then fasten them together w ith M4 nu ts a s shown be low.
Display
Gasket
18
User’s Manual
Page 22

6. Connection to the Host Computer and Power Supply

6. Connection to the Host Computer and Power Supply
If using IPC or SBC products other than those listed here, refer to their respective manuals for details of the settings.

Setting up the Host Computer

The IPC-DT/L40S(PC)T and IPC-DT/H40X(PC)T can be used with host computers such as the CONTEC IPC Series and SBCs (single­board computers). The host computer to be connected must be set up correctly for using the display. Set the IPC-DT/L40S(PC)T to SVGA (800 x 600) or the IPC-DT/H40X(PC)T to XGA (1024 x
768). Set the LCD type as follows depending on the host computer to be
used.
PC-686BX(PC)-LV
To use this SBC board with the display, set the on-board switch (U2) as shown below.
Note!
User’s Manual
12.1-inch IPC-DT/L40S(PC)T 15-inch IPC-DT/H40X(PC)T U2 U2
ON
12345678
Set all bits to OFF.
(TFT color LCD in 800 x 600) (TFT color LCD in 1024 x 768)
ON
12345678
Set only 1 to ON
Figure 6.1. U2 Switch Settings
Use this board along with the ISA bus type of LCD signal conversion board [ADPLNK(PC)].
19
Page 23
6. Connection to the Host Computer and Power Supply
PC-686C(PC)-LV or -LVS
Since this SBC board is Plug and Play compliant, there is no need to set up the host computer.
Instead, set the DIP built-in switch No. 2 to ON. (See Chapter 4.)
Note!
Use this board along with the 26/20-pin conversion cable [IPC-PL2620-002/C].
PC-686E(PC)-LV
To use this SBC board with the display, set the on-board rotary switch as shown below.
Table 6.1. PC-686E(PC)-LV
12.1-inch IPC-DT/L40S(PC)T 15-inch IPC-DT/H40X(PC)T
Setting No. = 0 (TFT color LCD in 800 x 600) Setting No. = 1 (TFT color LCD in 1024 x 768)
Note!
Use this board along with the ISA bus type of LCD signal conversion board [ADPLNK(PC)].
20
User’s Manual
Page 24
6. Connection to the Host Computer and Power Supply
PC-586U(PC)-LV or -LVS
To use this SBC board with the display, set the on-board switch (S2) as shown below.
12.1-inch IPC-DT/L40S(PC)T 15-inch IPC-DT/H40X(PC)T S2 S2
ON
ON
Note!
1234
Set all bits to OFF. Set only 1 to ON.
(TFT color LCD in 800 x 600) (TFT color LCD in 1024 x 768)
1234
Figure 6.2. S2 Switch Settings
Use this board along with the LCD signal conversion mini-board [EXLCD68] and the ISA bus type of LCD signal conversion board [ADPLNK(PC)].
PC-586HU(PC)-LV
To use this SBC board with the display, set the on-board jumper (JP8) as shown below.
12.1-inch IPC-DT/L40S(PC)T JP8
7 8
Leave all pins unconnected. Connect only the 1-2 pins.
(TFT color LCD in 800 x 600)
1 2
15-inch IPC-DT/H40X(PC)T
JP8
7 8
(TFT color LCD in 1024 x 768)
1 2
Note!
User’s Manual
Figure 6.3. JP8 Setting
Use this board along with the ISA bus type of LCD signal conversion board [ADPLNK(PC)].
21
Page 25
6. Connection to the Host Computer and Power Supply
IPC-BX/M600(PCW)
To use this box computer with the display, set the on-board switch (S1) as shown below.
12.1-inch IPC-DT/L40S(PC)T 15-inch IPC-DT/H40X(PC)T S1 S1
ON
ON
12345678
Set 5, 6, and 7 to ON.
(TFT color LCD in 800 x 600) (TFT color LCD in 1024 x 768)
12345678
Set 6, 7, and 8 to ON.
Figure 6.4. S1 Switch Settings
22
User’s Manual
Page 26

Connection Example

Illustrated below is an example of connecting the display to the box computer [IPC-BX/M600(PCW)C, CP].
IPC-BX/M600(PCW)C, CP
Panel Link cable(Option) [IPC-PL2020-020] (2m) [IPC-PL2020-050] (5m)
Display
-IPC-DT/L40S(PC)T
-IPC-DT/H40X(PC)T
Figure 6.5. System Configuration
6. Connection to the Host Computer and Power Supply
5VDC
User’s Manual
23
Page 27
6. Connection to the Host Computer and Power Supply

Power Supply

The display operates at 5VDC. For the supply voltage, use a power supply satisfying at least the capacity defined in the Specifications. Turn the 5VDC supply On in accordance with the following sequence.
1 - 50ms
(Rise time to 4.75V)
+5V
0V
Figure 6.6.
Power On Sequence
Table 6.2. Power Supply Connector
Connector type
Model
Pin No.
5VDC input connector B4PS-VH(LF)(SN)(mfd. by JST)
Signal name 1 2 3 4
GND GND
+5V +5V
4321
Applicable power cable connector
Housing: VHR-4N (manufactured by JST) Contact: SVH-21T-1.1(LF)(SN)(AWG22 - 18)
(manufactured by JST)
Although the display operates at 5VDC, the dedicated 5VDC output AC power supply [IPC-POA100D] is available as an option so that the display can be used with an AC power supply.
24
User’s Manual
Page 28
6. Connection to the Host Computer and Power Supply

Panel Link Connector Specifications

The display is equipped with the Panel Link Interface. The table below lists the pin specifications of the Panel Link connector on the back of the display.
Table 6.3. Panel Link Connector
Connector type
Model
Panel Link Interface connector(CN3) N10220-5DG3 PL(mfd. by 3M)
A1A10
Pin No.
A1 A2 A3 A4 A5 A6 A7 A8 A9
A10
B10
TX0-
TX0+ TX0 SHIELD TX2 SHIELD
TX2-
TX2+
DDC/SCL DDC/SDA
TXD(HOST)
RXD(HOST)
B1 B2 B3 B4 B5 B6 B7 B8 B9
B10
B1
Signal namePin No.Signal name
TXC-
TXC+ TXC SHIELD TX1 SHIELD
TX1­TX1+
N.C.
SENS
N.C.
GND
User’s Manual
25
Page 29
6. Connection to the Host Computer and Power Supply
26
User’s Manual
Page 30

7. Touch Panel

The IPC-DT/L40S(PC)T) and IPC-DT/H40X(PC)T is equipped with a quick response touch panel which enables keyboard-less, mouse-less operations using the serial interface (RS-232C) with the host computer.
CPU
7. Touch Panel
Touch panel
Host PC Touch panel controller Touch panel
Serial controller
NS16550 compatible
8bit CPU
INT
Serial
communication
Figure 7.1. Touch Panel and Block Diagram
Data input at the touch panel is processed by the touch panel controller and passed to the host PC via the serial port on the CPU in the controller.
Before the touch panel can be used, touch panel driver software (TPBK(PC)S) must be installed. Note that the driver software is not bundled with this product. Use th e one (to be) downloadable from the CONTEC’s home page or the one included on the driver software CD-ROM (IPC-SLIB-01) available as an option (separately priced). The CD-ROM need to be purchased separately.
The touch panel driver supports Windows 95, 98, NT4.0, and 2000. For further details, refer to the READ_ME file for each driver.
Communication format
- Baud rate 9600
- Data length 8 bits
- Parity Even parity
- Stop bit 1 bit
User’s Manual
27
Page 31
7. Touch Panel
28
User’s Manual
Page 32

8. Options

Double-sided screen protective sheets
- IPC-CV12 : (12.1-inch screen protective sheets: 10 sheets)
- IPC-CV15 : (15-inch screen protective sheets: 10 sheets)
Driver
- IPC-SLIB-01 : Driver & Utility Soft Set(CD-ROM version)
Power unit
- IPC-POA100D : 100V to 240VAC power unit
- IPC-POD24/5 : 24VDC input power unit
LCD I/F board
- ADPLNK(PC)H : Panel Link I/F board for SBC(ISA bus)
Optional cables
- IPC-PL2020-020 : Panel link cable (2 m)
- IPC-PL2020-050 : Panel link cable (5 m)
- IPC-DVIPL-020 : DVI - panel link conversion display cable (2m)
- IPC-DVIPL-050 : DVI - panel link conversion display cable (5m)
8. Options
User’s Manual
29
Page 33
IPC-DT/L40S(PC)T
IPC-DT/H40X(PC)T
User’s Manual
IPC-DT/x40x-HMU
CONTEC CO.,LTD.
3-9-31, Himesato, Nishiyodogawa-ku, Osaka 555-0025, Japan Japanese http://www.contec.co.jp/ English http://www.contec.com/ Chinese http://www.contec.com.cn/
No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD. [08012007]
[02222001] Management No. A-46-452 [08012007_rev7] Parts No. LZS9912
August 2007 Edition
Loading...