Thank you for purchasing the CONTEC product.
The product consists of the items listed below.
Check, with the following list, that your package is complete. If you discover damaged or missing
items, contact your retailer.
Product Configuration List
- Micro converter …1
[COM-1PD(USB)H]
- First step guide …1
- COM Setup Disk(CD-ROM *1) …1
- Warranty Certificate …1
- Serial number label …1
*1: The CD-ROM contains the driver software and User’s Guide (this guide)
COM-1PD(USB)H
i
Page 3
Copyright
Copyright 2004 CONTEC CO., LTD. ALL RIGHTS RESERVED
No part of this document may be copied or reproduced in any form by any means without prior written
consent of CONTEC CO., LTD.
CONTEC CO., LTD. makes no commitment to update or keep current the information contained in this
document. The information in this document is subject to change without notice.
All relevant issues have been considered in the preparation of this document. Should you notice an
omission or any questionable item in this document, please feel free to notify CONTEC CO., LTD.
Regardless of the foregoing statement, CONTEC assumes no responsibility for any errors that may
appear in this document or for results obtained by the user as a result of using this product.
Trademarks
MS, Microsoft, Windows and Windows NT are trademarks of Microsoft Corporation. Other brand and
product names are trademarks of their respective holder.
COM-1PD(USB)H
ii
Page 4
Table of Contents
Check Your P ackage................................................................................................................................ i
Table of Contents ...................................................................................................................................iii
1. BEFORE USING THE PRODUCT 1
About the P r o duct ...................................................................................................................................1
Customer Su pport.................................................................................................................................... 3
Web Site ...........................................................................................................................................3
Limited On e-Year Warranty................................................................................................................... 3
How to Obta in Service............................................................................................................................ 3
What is Setup?......................................................................................................................................... 7
Installing the driver ..........................................................................................................................7
Step 1 Sett ing the Hardw are ...................................................................................................................8
Name of each parts and Factory sett ing ..........................................................................................8
Setting the Data Trans mi ssion Mode ..............................................................................................9
Setting the Terminatin g Resistors .................................................................................................10
Step 2 Installing the Hardware .............................................................................................................12
Connecting the converte r ...............................................................................................................12
Setting wi th the Found New Hardware Wizard............................................................................ 13
Step 3 Initi alizing the Software ............................................................................................................15
Step 4 Checking Operations with the Diagno sis Progra m...................................................................16
What is the D iagnosis Pr o gram? ...................................................................................................16
Check Metho d ................................................................................................................................16
Using the Di agnosis Program........................................................................................................ 17
Step 5 Uninstalling the Driver Lib r aries ..............................................................................................19
COM-1PD(USB)H
iii
Page 5
If your problem cannot be resolved ......................................................................................................19
LED display ...........................................................................................................................................25
Hardware sp e cification..........................................................................................................................26
This chapter provides information you should know before using the product.
About the Product
This product is an isolated micro converter for converting the USB port of PC into RS-422A/485 serial
communications. Each converter has one channel RS-422A/485 communication port. Higher
noise-resistant models with isolation between a PC and bus line as well as a surge protection circuit for
communication ports. This product supports a baud rate of up to 921,600bps and has separate
128-byte / 384-byte buffer memory for transmit and receive. It also comes with a Windows driver,
which allows boards to be used as OS-standard COM ports.
This product supports CONTEC-defined driver library “API-PAC(W32)” that provide local routines.
Features
- Max. 921,600bps RS-422A/485 Serial Communication
This product has one channel RS-422A/485-standard serial ports. Baud rates from 300 to 921,600bps
can be set by software. When data is transferred at the high speed, it may not be transferred normally,
depending on the use environment such as the external device and cable length used.
- Compatible to USB1.1/USB2.0 and not necessary to power this product externally as the bus power
is used.
Compatible to USB1.1/USB2.0 and capable to achieve high speed transfer at Full Speed (12Mbps).
Not necessary to power this product externally as the bus power of USB is used.
- Possibly used as Windows-standard COM ports, using the bundled driver library
Comes with a driver software that allows the products to be used under Windows in the same way as
COM ports on the PC. Under Windows, the product supports the OS-standard Win32 API
communication function as well as Visual Basic MSComm. In addition, supplies a diagnostic program
to confirm hardware operation and to perform a communication test with equipment.
- Electric isolation is provided between channels and between PCs.
Electric isolation is provided between channels and between PCs.
This prevents electric noise between PCs and external circuits.
- Max. 127 converter can be installed as configured in the range COM1 - COM256.
Using a USB hub allows you to install up to 127 converters to a single PC.
COM1 - COM256 can be set using the device manager.
COM-1PD(USB)H
1
Page 7
1. Before Using the Product
- Each channel is equipped with separate 128-byte / 384-byte FIFO buffers for transmit and receive.
These are FIFO format, useful for high speed communications and to reduce the load to the CPU when
transmitting/receiving.
As the device manager can be used to enable/disable the use of FIFO and set the FIFO trigger size, you
can build an optimum system according to your use.
- To suit your application, cables and connectors are available as optional
Straight cables (1.8m), cross cables (1.8m) and 9-pin D-SUB connectors (male or female type) for your
own cables are available as optional.
- The control line for RS-422A/485 can be controlled and monitored by software.
The control lines for RTS+, RTS-, CTS+ and CTS- can be controlled and monitored using software.
Support Software
Standard COM Driver Software
Under Windows, this software allows you to use the serial ports on the converter as if they were
standard COM ports on the PC. You can add additional micro converters up to a maximum of 127
COM ports.
Under Windows, the serial ports can be accessed using the standard Win32 API communication routines
(CreateFile( ), WriteFile( ), ReadFile( ), and SetCommState( ), etc.) The serial ports are also
compatible with the Visual Basic communication control (MSComm). * API-SIO(98/PC) is not used.
< Operating environment >
OS
Windows Vista, XP,
COM Setup Disk
Server 2003,
2000
(Bundled)
Cable & Connector (Option)
D-SUB 9 pin Male Connector Set (5 Pieces) : CN5-D9M
D-SUB 9 pin Female Connector Set (5 Pieces) : CN5-D9F
COM-1PD(USB)H
2
Page 8
1. Before Using the Product
Customer Support
CONTEC provides the following support services for you to use CONTEC products more efficiently
and comfortably.
Web Site
Japanese http://www.contec.co.jp/
English http://www.contec.com/
Chinese http://www.contec.com.cn/
Latest product information
CONTEC provides up-to-date information on products.
CONTEC also provides product manuals and various technical documents in the PDF.
Free download
You can download updated driver software and differential files as well as sample programs available in
several languages.
Note! For product information
Contact your retailer if you have any technical question about a CONTEC product or need its price,
delivery time, or estimate information.
Limited One-Year Warranty
CONTEC Interface products are warranted by CONTEC CO., LTD. to be free from defects in material
and workmanship for up to one year from the date of purchase by the original purchaser.
Repair will be free of charge only when this device is returned freight prepaid with a copy of the
original invoice and a Return Merchandise Authorization to the distributor or the CONTEC group office,
from which it was purchased.
This warranty is not applicable for scratches or normal wear, but only for the electronic circuitry and
original products. The warranty is not applicable if the device has been tampered with or damaged
through abuse, mistreatment, neglect, or unreasonable use, or if the original invoice is not included, in
which case repairs will be considered beyond the warranty policy.
How to Obtain Service
For replacement or repair, return the device freight prepaid, with a copy of the original invoice. Please
obtain a Return Merchandise Authorization number (RMA) from the CONTEC group office where you
purchased before returning any product.
* No product will be accepted by CONTEC group without the RMA number.
Liability
The obligation of the warrantor is solely to repair or replace the product. In no event will the
warrantor be liable for any incidental or consequential damages due to such defect or consequences that
arise from inexperienced usage, misuse, or malfunction of this device.
COM-1PD(USB)H
3
Page 9
1. Before Using the Product
Safety Precautions
Understand the following definitions and precautions to use the product safely.
Safety Information
This document provides safety information using the following symbols to prevent accidents resulting
in injury or death and the destruction of equipment and resources. Understand the meanings of these
labels to operate the equipment safely.
DANGER
WAR NI NG
CAUTION
Handling Precautions
DANGER
Do not use the product where it is exposed to flammable or corrosive gas. Doing so may result in
an explosion, fire, electric shock, or failure.
CAUTION
- Do not strike or bend this product.
Otherwise, these products may malfunction, overheat, cause a failure or breakage.
- Do not touch this product's metal plated terminals (USB connector, D-SUB connector) with your
hands.
Otherwise, the product may malfunction, overheat, or cause a failure.
If the products are touched by someone's hands, clean the products with industrial alcohol.
- Make sure that your PC can supply ample power to all the products installed.
Insufficiently energized products could malfunction, overheat, or cause a failure.
- The specifications of this product is subject to change without notice for enhancement and quality
improvement.
Even when using this product continuously, be sure to read the manual and understand the contents.
- Do not modify this product. CONTEC will bear no responsibility for any problems, etc., resulting
from modifying this product.
- Regardless of the foregoing statements, CONTEC is not liable for any damages whatsoever
(including damages for loss of business profits) arising out of the use or inability to use this
CONTEC product or the information contained herein.
- It may cause a trouble in recognizing and operating the device according to the kind of USB hub.
If you use the USB hub, we encourage you to take advantage of the CONTEC’s product loan
service to confirm operation before purchasing.
COM-1PD(USB)H
4
DANGER indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury or in property damage.
Page 10
1. Before Using the Product
- Regarding “EMC Instruction Class A Notice”
This product has acquired the above-mentioned standard.
However, a sufficient margin may not be secured for the standard. In this case, use a ferrite core
(SEIWA E04SR301334 or a compatible product) for the COM cable (this product’s / connected
device’s side) or use a ferrite core (SEIWA E04SR170730A or a compatible product) for the USB
cable (PC side).
When attaching a ferrite core to the USB cable, just put the cable inside the case; when attaching a
ferrite core to the COM cable, coil it around once near the connector while leaving it open, and then
close it.
FCC PART 15Class A Notice
NOTE
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in commercial
environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference at his own expense.
WARNING TO USER
Change or modifications not expressly approved the manufacturer can void the user's
authority to operate this equipment.
COM-1PD(USB)H
5
Page 11
1. Before Using the Product
Environment
Use this product in the following environment. If used in an unauthorized environment, the board may
overheat, malfunction, or cause a failure.
Operating temperature
0 - 50°C
Operating humidity
10 - 90%RH (No condensation)
Corrosive gases
None
Floating dust particles
Not to be excessive
Inspection
Inspect the product periodically as follows to use it safely.
- The connection part of connector
have no stain or corrosion.
Storage
When storing this product, keep it in its original packing form.
(1) Put the product in the storage bag.
(2) Wrap it in the packing material, then put it in the box.
(3) Store the package at room temperature at a place free from direct sunlight, moisture, shock,
vibration, magnetism, and static electricity.
Disposal
When disposing of the product, follow the disposal procedures stipulated under the relevant laws and
municipal ordinances.
COM-1PD(USB)H
6
Page 12
2. Setup
2. Setup
This chapter explains how to set up the converter.
What is Setup?
Setup means a series of steps to take before the product can be used.
Different steps are required for software and hardware.
Installing the driver
This section enables you to prepare the software and hardware by operating in accordance with each
step in this chapter using the bundled CD-ROM. Taking the following steps sets up the software and
hardware. You can use the diagnosis program later to check whether the software and hardware
function normally.
Step 1 Setting the Hardware
Step 2 Installing the Hardware
Step 3 Initializing the Software
Step 4 Checking Operations with the Diagnosis Program
If Setup fails to be performed normally, see the “Setup Troubleshooting” section at the end of this
chapter.
COM-1PD(USB)H
7
Page 13
2. Setup
Step 1 Setting the Hardware
This section describes how to setup the converter and connect it to your PC.
There are switches and jumpers on the product that need to be set in advance.
The converter can be set up even with the factory defaults untouched. You can change board settings
later.
Name of each parts and Factory setting
Note that the switch setting shown below is the factory default.
COM-1PD(USB)H
Interface connector
D-SUB 9 pin (Male)
- Data transmission mode,
terminator setting SW
0
91
ON
345678
12
Interface connector
USB TypeA
Figure 2.1. Name of each parts and Factory setting
Turn the screwdriver to the right.
Connection cable
Figure 2.2. How to open the cover
Insert a standard screwdriver into the groove in the cover and turn the screwdriv er.
CAUTION
Pushing the screwdriver in too far may damage the inside of the connector. Take care not to apply
any force to the inside when turning the screwdriver.
COM-1PD(USB)H
8
Page 14
2. Setup
Setting the Data Transmission Mode
The data transmission mode setting switch can be used to switch between half-duplex and full-duplex
and between RTS and CTS in full-duplex mode. Set the appropriate data transmission mode
depending on the remote device to which to connect this converter. Set the transmission mode using
from the bit 1 to bit 6.
Setup method
Table 2.1. Setting the Data Transmission Mode
Full-duplex [Full]
Data
Transmission
Mode
Setup
method
Half-duplex [Half]
109
8
7
654321
ON
This sets TxD as the only data
line and uses the RTS signal on
the converter to switch between
send and receive.
Loopback RTS and CTS
RTS
CTS
109
8
7
654321
ON
If the device you are
communicating with does not use
the RTS and CTS signals, you can
use this setting to make CTS
active
when the RTS signal on the
converter is set to active.
CAUTION
Do not set bits 1 and 2 of each switch to both ON. Doing so may cause the Converter to
malfunction.
Connect RTS and CTS to
external device
RTS
CTS
109
87
6
5
4
321
ON
Connecting to the RTS and
CTS
signals from the external
device.
COM-1PD(USB)H
9
Page 15
2. Setup
Setting the Terminating Resistors
When inserting a terminator, use the terminator setting switch. Set the terminator depending on the
remote device to which to connect the converter. The converter contains a 100Ω resistor as a
terminator.
The bits correspond to individual signal conductors. Bits 7, 8, 9, and 10 are for RxD, CTS, TxD, and
RTS, respectively.
Setup method
To set the terminal to a resistor other than 100Ω, set the terminator setting switch to OFF and insert an
external terminator. Given below are examples of inserting the terminator for half-duplex or
full-duplex setup.
Table 2.2. Setting the Terminator
Not insert the terminator
RTS
TxD
CTS
RxD
ON
109
87
6
5
4
321
Factory
setting
- Half-duplex
Ter mi na to r
(bit9)
(A)
(B)
(C)(D)
Figure 2.3. Party Line Connection
Ter mi na to r
(bit9)
[A or D]
Insert the
Ter mi na to r
RTS
TxD
CTS
RxD
ON
[B or C]
Not insert
the Terminator
RTS
TxD
CTS
RxD
ON
RTS
109
TxD
87654321
CTS
RxD
109
87654321
Not insert
the Terminator
109
87654321
ON
COM-1PD(USB)H
10
Page 16
2. Setup
- Full-duplex
Terminator(bit9)Terminator(bit7)
TxD
RxD
Terminator(bit7)
Terminator(bit9)
Set the terminator of RTS, CTS to OFF.
RxD
TxD
Insert the
terminator
RTS
TxD
CTS
RxD
ON
109
87654321
Not insert the
terminator
RTS
TxD
CTS
RxD
ON
109
87654321
Figure 2.4. Loopbacking RTS and CTS
Terminator(bit9)Terminator(bit7)
TxD
RxD
Terminator(bit7)Terminator(bit9)
Terminator(bit10)Terminator(bit8)
RxD
TxD
Insert the
terminator
RTS
RTS
TxD
TxD
CTS
CTS
RxD
RxD
ON
109
87654321
Not insert the
terminator
RTS
TxD
CTS
RxD
ON
109
87654321
RTS
CTS
Terminator(bit8)Terminator(bit10)
CTS
RTS
Figure 2.5. Connecting RTS and CTS to external device
Illustrated below are the peripheral circuits for the data transmission mode setting and terminator setting
switches.
TxEN
TxD
RxD
RTS
CTS
DCD
DTR
DSR
1
2
3
4
5
6
TxEN, S EL
RTS
RI
10
Term in at or
Ω
100
7
8
9
04 TxD+
05 TxD-
08 RxD+
09 RxD-
02 RTS+
03 RTS-
07 CTS+
06 CTS-
Figure 2.6. Equivalent Circuits
COM-1PD(USB)H
11
Page 17
2. Setup
Step 2 Installing the Hardware
Under Windows, you have to let the OS detect the remote device. The process is referred to as
installing the hardware.
When using multiple converters, install one at a time and complete setup for the previous
converter before starting to install the next converter.
Connecting the converter
(1) Turn on the power to the PC before connecting the product.
(2) When the PC has been up and running, plug the USB interface connector to a USB port in the PC.
The converter can also be connected to the PC via a USB hub.
USB ports
Figure 2.7. Connecting the converter
CAUTION
It may cause a trouble in recognizing and operating the device according to the kind of USB hub.
If you use the USB hub, we encourage you to take advantage of the CONTEC’s product loan
service to confirm operation before purchasing.
COM-1PD(USB)H
12
Page 18
2. Setup
Setting with the Found New Hardware Wizard
(1) The “Found New Hardware Wizard” will be started.
(2) Select “Install from a list or specific location[Advanced]”, then click on the [Next] button.
(3) Specify that folder on the CD-ROM which contains the setup information (INF) file to register the
converter.
Source folder i s “(CD-ROM drive letter)\USB\COM1USB”.
* Be sure to uncheck [Search removable media (floppy, CD-ROM)].
COM-1PD(USB)H
13
Page 19
2. Setup
(4) In Windows XP, the Hardware Wizard displays the following alert dialog box when you have
located the INF file. This dialog box appears, only indicating that the relevant driver has not
passed Windows Logo testing, and it can be ignored without developing any problem with the
operation of the terminal.
In this case, click on the [Continue Anyway] button.
When completing the installation, push the completion button and close the wizard.
(5) After that, do the same operation so that you can confirm the COM port.
You have now finished installing the hardware.
COM-1PD(USB)H
14
Page 20
2. Setup
Step 3 Initializing the Software
The COM ports are already assigned by the hardware installation step.
Run Device Manager as described below if you wish to view or modify the COM port settings.
Start Device Manager
(1) Select "System" from "Control Panel" and start [Device Manager].
(2) Make sure that the detected USB device is listed in the "Universal Serial Bus controllers" folder.
(3) Check that the new COM ports are displayed in the [Ports] folder.
Updating the Settings
(1) If you wish to change a port number, open the properties page for the port and click the
[Advanced…] button under [Port Settings].
(2) Use the [COM Port Number] combo box to modify the COM port number.
You have now finished installing the initial setting of Software.
COM-1PD(USB)H
15
Page 21
2. Setup
Step 4 Checking Operations with the Diagnosis
Program
Use the diagnosis program to check that the terminal and driver software work normally, thereby you
can confirm that they have been set up correctly.
What is the Diagnosis Program?
These programs perform some simple checks on the terminal operation. Two programs are provided.
Terminal program (CTstCom.exe)
Data entered from the keyboard is sent directly from the port. The function of the program is
equivalent to the Hyper Terminal program provided with Windows.
Serial Communications Diagnostic Program (CommChk.exe)
Performs actual communications and indicates whether the results are correct or not (error).
The following describes the procedure for testing using the serial communications diagnostic program
(CommChk.exe).
Check Method
Obtain an RS-422A/485 crossed cable. If you do not have a crossed cable, you can perform the test on
a single COM port by using the switch settings on the converter to set communications to loopback.
The figure below shows the switch settings.
SW setting using the cross cable
109
87
6
5
4
321
ON
When using the COM-1PD(USB)H in loopback mode instead of using a cross cable
109
87
6
5
4
321
ON
COM-1PD(USB)H
16
Page 22
2. Setup
Using the Diagnosis Program
Starting the Diagnosis Program
Run [\Utility\CommChk\CommChk.exe] from the supplied CD-ROM.
Communication Settings
COM Setup: Specify the number of the COM port you wish to test.
If connecting two COM ports via a cross cable, specify the respective COM ports in
[Device1] and [Device2].
When performing loopback communications on a single COM port, set the same port
number in both [Device 1] and [Device 2].
Communication Settings: Specify the [Bits / Second], [Data bits] and other settings you wish to use.
COM-1PD(USB)H
17
Page 23
2. Setup
Start test
Click the [Start] button to start the test using the specified conditions.
View test result
The test result is displayed in the [Message] window.
A successful completion message appears if the test completed OK.
COM-1PD(USB)H
18
Page 24
2. Setup
Step 5 Uninstalling the Driver Libraries
To uninstall COM-1/1P/1PD(USB)H Drivers, follow the procedure below.
(1) Click on the [Start] button on the Windows taskbar. From the Start Menu, select “Settings” –
“Control Panel”.
(2) Double-click on “Add and Remove Programs” in the Control Panel.
(3) Select “CONTEC COM-1/1P/1PD(USB)H Drivers VerX.XX” from the displayed application and
then click on the [Change/Remove] button. Follow the on-screen instructions to uninstall the
function libraries.
* X.XX shows the version of driver.
If your problem cannot be resolved
Contact your retailer.
COM-1PD(USB)H
19
Page 25
2. Setup
COM-1PD(USB)H
20
Page 26
3. External Connection
3. External Connection
This chapter describes the interface connectors on the converter.
Check the information available here when connecting an external device.
Interface connectors
1
SGSignal Ground
Clear to Send- CTS -
Clear to Send+ CTS+
Receive Data+ RxD+
Receive Data- RxD-
Figure 3.1. Pin assignment of interface connectors
CAUTION
For TxD, RxD, and RTS, pin assignment has even-numbered pins for positive and odd-numbered
ones for negative. For CTS, however, even-numbered and odd-numbered pins are assigned for
negative and positive, respectively, in contrast with other signals. This is not a description error.
6
RTS + Request to Send+
2
7
RTS -Request to Send-
3
8
4
TxD + Transmit Data+
9
TxD -Transmit Data-
5
COM-1PD(USB)H
21
Page 27
3. External Connection
Example Connections
The RS-422A/485 interface provides a differential method of transmission, in which relative potential
differences between two conductors (positive and negative) are meaningful as signals.
For the converter, a twisted-pair cable (balanced line) should be used as possible to improve noise
immunity.
TxD+
TxD
RxD+
RxD
RTS+
RTS
CTS+
CTS
SG
-
-
-
-
TxD+
TxD
RxD+
RxD
RTS+
RTS
CTS+
CTS
SG
-
-
-
-
External device
Figure 3.2. Example of connection with RTS and CTS connected to external device in full-duplex
mode
TxD+
TxD
RxD+
RxD
SG
-
-
TxD+
TxD
RxD+
RxD
SG
-
-
External device
Figure 3.3. Example of connection with RTS and CTS self-looping in full-duplex mode
TxD+
TxD
SG
-
TxD+
TxD
SG
-
External device
Figure 3.4. Example of connection in half-duplex mode
CAUTION
Connecting the converter by incorrect wiring can cause a fault in the converter and/or the device
connected.
COM-1PD(USB)H
22
Page 28
4. Functions
4. Functions
This section describes the functions of the converter.
Communication Function
Serial Data Transmission
Sends and receives data in accordance with the RS-422A/485 standard.
RS-422A/485 Control Lines
All ports include the RTS+, RTS-, CTS+ and CTS- control lines.
The lines can be controlled or monitored by software from the application.
Setting the Baud Rate
This converter can set the following baud rate using the software.
Baud Rate: 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400,
57600, 115200, 230400, 460800 , 92 1600bps
Bus isolation
It is electrically isolated between the PC to be installed and the remote device.
Isolation between buses, prevents electrical disturbance between the PC and an external circuit and
inter-channel interference as well.
The converter can therefore be used comfortably even when line noise can be easily generated to
seemingly cause the PC to malfunction or break.
Surge protection
As the RS-422A/485 control lines are all surge-protected, you can use the product without anxiety about
surges which can cause the PC to malfunction or be damaged.
COM-1PD(USB)H
23
Page 29
4. Functions
COM-1PD(USB)H
24
Page 30
5. About Hardware
5. About Hardware
LED display
Table 5.1. Function list
LED name LED display content
ON … Power ON POWER (green)
OFF … Power OFF
Blinking … Receiving data * RxD (yellow)
OFF … Not receiving data or not connected
Blinking … Transmitting data * TxD (yellow)
OFF … Not transmitting data or not connected
TxD
RxD
POWER
Figure 5.1. LED display
*
If you forget the COM port number of this product, perform communication via specific COM ports and check the
LEDs on the product to identify its COM port number.
COM-1PD(USB)H
25
Page 31
5. About Hardware
Hardware specification
Table 5.2. Specification
Item COM-1PD(USB)H
Number of channels
I/O specification
Isolated specification
Dielectric strength
Transfer method
Baud rate
Data length
Parity check
Loading LSI
Connecting distance
Connector specification
Operation guaranteed
voltage
Power consumption
Operating condition
USB bus specification USB Specification 1.1/2.0 standard
Power supply Only bus power
USB transmission speed 12Mbps (full speed mode)
Cable length 1.8m
Physical dimension (mm) 68.3(W) x 20.5(D) x 36.5(H)
Weight 130g
*1 Data transmission at high speed may not be performed normally depending on the environment including the type of
status of connected material of cable and environment.
*2 These items can be set by software.
1 channel
RS-422A/RS-485
Bus isolation
300VDC
Asynchronous serial transfer (Full-duplex / half-duplex)
300 - 921,600bps *1*2
7, 8 bit / 1, 2 stop bit
Even, Odd, Non-parity
FT232BL
Mounting the FIFO memory as the common buffer of RS-422A/RS-485
communication and USB. Sending: 128byte / receiving: 384byte (by the
view of PC)
Within 1200m
USB side : USB A connector
RS-422A/485 side : 9 pin D-SUB connector (male)
±5%
5V
5VDC 350mA (Max.)
0 - 50°C, 10 - 90%RH(No condensation)
Physical dimension
#4-40UNC (inch screw)
36.5
59.8
68.3
Figure 5.2. Physical dimension
COM-1PD(USB)H
26
20.5
[mm]
Page 32
COM-1PD(USB)H
User’s Guide
CONTEC CO.,LTD. May 2012 Edition
3-9-31, Himesato, Nishiyodogawa-ku, Osaka 555-0025, Japan
Japanese http://www.contec.co.jp/
English http://www.contec.com/
Chinese http://www.contec.com.cn/
No part of this document may be copied or reproduced in any form by any means without prior written
consent of CONTEC CO., LTD. [05232012]
[11162004] Management No. A-46-833
[05232012_rev7] Parts No. LYDG465
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.