1) The Speed Setting; UO
Press R; Display UO, Press M to adjust; Display the number 5 to 70; {5 represents a minimum speed
of 500 rpm, 70 represents the maximum speed of 7000 rpm}.
Example 1: You need 3500 rev/min
Press R: Display UO; Press M to adjust; Digital display 35; Press L to save.
Example 2: You need 500 rev/min
Press R: Display UO; Press M to adjust; Digital display 5; Press L to save.
2) Upper and lower needle position set; U1
Press R; Display U1; Press M to adjust; Display number 0 to 1; {0 for the next stop pin; 1 for the
stop pin}; Press R to save
3) Reversing settings; U2
Press R; Display U2; Press M to adjust; Display number 0 to 1; {0 clockwise; 1 is the reversed},
Press R to save.
4) Location parameter setting; U3
Press R; Display U3; Press M to adjust; Display the number 8 to 20; (The smaller the number, the
more slowly, but the positioning is more accurate; The bigger the number, the faster the location, the
more not allowed), Press R to save.
5) Slow start setting U4
Press R; Display U4; Press M to adjust; Display the number 0 to 9; Press R to save
6) Other display instructions:
{1}When the motor stall failure occurs, when it display E1, the motor does not work, press the R key
to recovery; Many times, it is recommended to reduce the load or contact your dealer.
{2}When the stream or under voltage fault occurred, when the motor display E2, the motor does not
work, press R key to recovery, many times, it is recommended to reduce the load or contact your
dealer.
{3}When the motor has the Hall signal error, it display E4, check the motor and controller plus
connection is intact, press R key to recovery many times, if not, please contact your dealer.
7) Restore factory settings:
In the U mode, press the M button for 3 seconds or more. The set parameters are reset to the factory
default state.
Specifications subject to change without notice.
©2017 Consew USA -0417