Conrad Powerline Adapter PL500D duo User manual

Conrad
Powerline Adapter PL500D duo
While the information in this manual has been compiled with great care, it may not be deemed an assurance of product characteristics. The manufacturer shall be liable only to the degree specified in the terms of sale and delivery.
The reproduction and distribution of the documentation and software supplied with this product and the use of it s contents is subject to written authorization from the manufacturer. We reserve the right to make any alterations that arise as the result of technical development.
Trademarks
®
and Microsoft® are registered trademarks of Microsoft, Corp.
®
is a registered trademark of HomePlug Power Alliance.
This product complies with the technical requirements of the EMC directive 2004/108/EC and the other relevant provisions of the FTEG, and it is designed for use in the EU an d Swit­zerland. The product is class B equipment.
For the CE declaration for this product, refer to the accompanying product CD.
Subject to change without notice. No liability for technical errors or omissions.
October 2013

Contents

1 Introduction ................................................................................................................ 4
1.1 What does Powerline stand for? ..............................................................................4
1.2 PL500D duo ............................................................................................................4
1.3 Practical examples................................................................................................... 5
2 Installation ..................................................................................................................6
2.1 System requirements ...............................................................................................6
2.2 Connection and display elements ............................................................................6
2.3 Connecting the adapter ...........................................................................................7
3 Configuring the PLC network ..................................................................................... 8
3.1 Encrypting the PLC network at the touch of a button............................................... 8
3.2 Encrypting the PLC network via the configuration software ...................................10
4 Appendix ................................................................................................................... 11
4.1 Bandwidth optimization ........................................................................................11
4.2 Disposal of old devices ..........................................................................................11
4.3 Important safety instructions .................................................................................12
4.4 Warranty conditions ..............................................................................................13
Powerline Adapter PL500D duo
4 Introduction

1 Introduction

This chapter gives an overview of Powerline and briefly introduces the adapter. Practical examples are listed at the end of the chapter.

1.1 What does Powerline stand for?

“Inhouse Powerline” (PLC, HomePlug) is an intelligent, secure technology that lets you set up a home network easily, quickly and economically via your electrical wiring, without the need for complex and expensive dedicated cabling. The available performance and effort required for the installation also compares favourably to traditional methods—PLC now attains speeds you would expect from other LAN technologies.

1.2 PL500D duo

The adapter provides a transmission rate of up to 500 Mbps via the electrical wiring in the building. It also facilitates larger data transfer between the com­puters in your network via th ates a high degree of flexibility. The two LAN be connected directly—especially practical for computers and network print­ers in the home office or Smart TV and a game console in the living room.
e electrical wiring. The range of 300 meters cre-
ports allow for two devices to
Simple Installation
Connect network device.
Connect the adap
As an option: for
button or install the configuration software on your computer
Th
Conrad Powerline Adapter PL500D duo
the adapter via the network cable to the computer or the respective
at's it!
ter to the electrical wiring
individual password allocation simply press the encryption

1.3 Practical examples

Internet solution for a single-user
Internet solution for multi-users
Introduction 5
Conrad Powerline Adapter PL500D duo
6 Installation

2Installation

This chapter describes the connection and display elements of the adapter and how to connect it.

2.1 System requirements

Operating systems: Windows Vista Home Premium (32 bit/64 bit),
Windows 7 (32 bit/64 bit),
64 bit) or any other operating system with network support
Network connection
Please note that your computer or other device mu adapter with an Ethernet port.

2.2 Connection and display elements

The adapter is fitted with one control lamp (LED) as well as two network con­nection and an encryption button. The LED shows PL500D duo by illuminating and/or flashing in different ways:
Windows 8 (32 bit/64 bit), Windows 8 Pro (32 bit/
st feature a network
all of the statuses for the
Power
Etherne
The LED flashes at uniform intervals (of 2 s) if the adapter is connected to t
The LED lights up if the adapter is ready to operate and there is a PLC conn
The LED flashes quickly if the encryp formed in the PLC network.
The LED flashes at irregular intervals (1 s/15 s) if the adapter is in Pow­erSave mode.
t connections These are the connection points on the adapter for connecting it to a com­puter and/or another network device with the network cable.
PLC button Data encryption at the touch of a button; For more information on the func­tions of the encryption button, please see the chapter 'Encrypting the PLC network at the touch of a button'.
Conrad Powerline Adapter PL500D duo
PL500D duo
he mains supply but there is no PLC connection.
ection.
tion process (pairing) is being per-
Please note that all adapters which are connected to the electrical wiring, switch to energy-saving mode after approx. 11 minutes, if no active network device is connected to the Ethernet port. In energy-saving mode, the adapter cannot be accessed via the electrical wiring.

2.3 Connecting the adapter

Use the included network cable to connect the adapter to the network
port of your running computer.
Installation 7
Plug the ad
In order to connect multiple PLC devices into a self-contained, secure net­work, now continue with the installation of mation, refer to the chapter 'Configuring the PLC network'.
apter into a free electrical outlet.
the configuration. For more infor-
Conrad Powerline Adapter PL500D duo
8 Configuring the PLC network

3 Configuring the PLC network

To set up custom encryption for your network—either using the PLC button or the Configuration Wizard.
3.1 Encrypting the PLC network at the touch of a but­ton
To encrypt a PLC network simply press the PLC button that is located on the device. Pressing this button will encrypt your network with a randomly gener­ated password.
Adapters cannot be configured while in Standby mode.
The following section contains exact instructions o work scenarios:
Encrypting a new PLC network consisting of two adapters
Once both adapters have been successfully connected, press each PLC but­ton for one second network is now protected against unauthorized access.
within two minutes of one another. That's it! Your PLC
n the basis of possible net-
Conrad Powerline Adapter PL500D duo
Expanding an existing PLC network with a new adapter
If you have already secured your existing PLC network using the use the same method to integrate other adapters. Once you have success­fully connected the new adapter, first press the PLC button of one of your work’s existing adapters (one second), th new adapter (one second) within two minutes. That's it! The new adapter is now integrated in your network.
Configuring the PLC network 9
PLC button,
net-
en press the PLC button of your
To integrate additional adapters in your network, repeat the abo
ve steps.
Excluding a adapter from your network To exclude a adapter from an existing network, press its encryption button fo
at least ten seconds. The device will be assigned a new randomly gener-
ated password and will thus no longer be able to access the network. To inte­grate the adapter in a different PLC network, follow the steps described above, depending on
whether you are setting up a new network or adding the
adapter to an existing one.
r
Conrad Powerline Adapter PL500D duo
10 Configuring the PLC network

3.2 Encrypting the PLC network via the configuration software

To install the software, insert the included CD-ROM in the CD drive of your computer. If autoplay is installed on your computer, the installation will start automatically. Otherwise, open the folder with the Windows Explorer by right­clicking on Start (or the Windows logo) and selecting Explorer from the con­text menu. Double-click to start the installation wizard manually.
Upon successful installation, the configuration software can be
Start --> All programs --> HomePlug --> HomePlug Configuration Wiz­ard.
Please note: You must conne grate securely in your network directly to your computer for configuration.
Assign a network pas
In this step, select a network password that home network. The password must be used by all devices.
The factory default password is Ho commend overwriting it and assigning a password of your own.
Ad
d further adapters
To add a new adapter to your network, first connect it directly to your com­puter and launch the wizard again. Then assign the password that will apply
ll adapters in your home network.
to a
ct every PLC device that you intend to inte-
sword
will apply to all adapters in your
mePlugAV. For security reasons, we re-
found under
Conrad Powerline Adapter PL500D duo

4 Appendix

For the technical specifications of this product, refer to the accompanying product CD.

4.1 Bandwidth optimization

Plug the device directly into a wall socket. Avoid multiple sockets. This may
impair the transmission of the PLC signals.
Plug the devices into
strip.
different outlets and avoid using the same extension
Appendix 11

4.2 Disposal of old devices

The icon with crossed-out wastebasket on the device means that this adapter is an electrical or electronic device that falls within the scope of application of the German Electrical and Electronic Equipment Act. Since 24 March 2006, these types of devices may no longer be disposed of with household waste. Rather, in Germany, they can be given to a municipal collection point free of charge. Contact your municipal government to find out the address and hours of the nearest collection point.
Conrad Powerline Adapter PL500D duo
12 Appendix

4.3 Important safety instructions

All safety and operating instructions should be read and understood before using the device, and should be kept for future reference.
Never open the device.
device.
Do not try to service this product yourself! Contact qualified technicians each and every shock!
time your device needs maintenance. There is a risk of electric
There are no user-serviceable parts inside the
Use the device in a dry
Always use the included
The outlet must be within reach of the connected network device. The adapter and the network device must be easily accessible.
switch the device off, pull the power plug.
To
disconnect the device from the power supply grid, pull the power plug.
To
Do not
Do not
S
Never set up
The device should
Disconnect the device
Never use th
In the
keep the device in direct sunlight. insert any objects into the openings of the device.
lots and openings on the case serve as ventilation. Never block or cover
them.
the device near a heater or radiator.
ensured.
moist towel to clean the device. Never use water, paint thinner, benzene, alcohol or other strong cleaning agents when cleaning the device, as these could damage the case.
e device with a power supply that does not meet the specifica­tions provided on the rating plate. If you do not supply you have at home, contact your dealer or energy supplier.
event of damage, disconnect the device from the power supply grid
and contact customer service. This applies, for example, if
power cable or plug is damaged.
the
liquid
the
has been spilled on the device or objects have fallen into the
device.
device has been exposed to rain or water.
location only.
network cable to connect the device.
be located only where sufficient ventilation can be
from the power supply grid before cleaning. Use a
know what type of power
Conrad Powerline Adapter PL500D duo
the device does not work, even though the operating instructions have been followed properly.
device’s case is damaged.
the

4.4 Warranty conditions

The warranty is given to purchasers of the manufacturer's products in addition to the warranty conditions provided by law and in accordance with the following conditions:
1 Warranty coverage
a) The warranty covers the eq
turer's sole discretion, be replaced or repaired free of charge if, despite p roven proper han­dling and adherence to the operating instructions, these parts became defective due to fabrication and/or material defects. Alternatively, the manufacturer reserves the right to replace the defective product with a comparable product with the same specifications and features. Operating manuals and possibly supplied software are excluded from the war­ranty.
b) Material and service charges shall be covered by the manufacturer, but not shipping and
handling costs involved in transport from the buyer to the service stat ion and/or to th e man-
ufacturer. c) Replaced parts become property of the manufacturer. d) The manufacturer is authorized to carry out technical changes (e.g. firmware updates)
beyond repair and replacement of defective parts in order to bring the equipment up to the
current technical state. This does not result in any additional charge for the customer. A
legal claim to this service does not exist.
uipment delivered and all its parts. Parts will, at the manufac-
Appendix 13
2 Warranty period
The warranty period for this product is two years. This period begins at the day of delivery from the manufacturer's dealer. Warranty serv ices carried out by the man ufacture r do no t result in an extension of the warranty period nor do they initiate a new warranty period. The warra nty period for installed replacement parts ends with the warranty period of the device as a whole.
3 Warranty procedure
a) If defects appear during the warranty period, t
ately, at the latest within a period of 7 days. b) In the case of any externally visible damage arising from transport (e.g. damage to the
housing), the person carrying out the transportation and the sender should be informed
immediately. On discovery of damage which is not externally visible, the transport company
and the sender are to be immediately informed in writing, at the latest with in 3 days of deliv-
ery. c) Transport to and from the location where the warranty claim is accepted and/or the repaired
device is exchanged, is at the purchaser's own risk and cost. d) Warranty claims are only valid if a copy of the original purchas e receipt is re turned with the
device. The manufacturer reserves the right to require the submission of the original pur-
chase receipt.
4 Suspension of the warranty
All warranty claims will be deemed invalid a) if the label with the serial number has been removed from the device,
he warranty claims must be made immedi-
Conrad Powerline Adapter PL500D duo
14 Appendix
b) if the device is damaged or destroyed as a result of acts of nature or by environment al influ-
ences (moisture, electric shock, dust, etc.), c) if the device was stored or operated under conditions not in compliance with the technical
specifications, d) if the damage occurred due to incorrect handling , especially to non-observance of the sys-
tem description and the operating instructions, e) if the device was opened, repaired or modified by persons not contracted by the manufac-
turer, f) if the device shows any kind of mechanical damage, or g) if the warranty claim has not been reported in accordance with 3a) or 3b).
5 Operating mistakes
If it becomes apparent that the reported malfunction of the device has been caused by un suitable hardware, software, installation or operation, the manufacturer reserves the right to charge the purchaser for the resulting testing costs.
6 Additional regulations
a) The above conditions define the complete scope of the manufacturer's legal liability. b) The warranty gives no entitlement to additional claims, such as any refund in full or in part.
Compensation claims, regardless of the legal basis, are excluded. This does not apply if
e.g. injury to persons or damage to private property are specifically covered by the pro duct
liability law, or in cases of intentional act or culpable negligence. c) Claims for compensation of lost profits, indirect or consequential detriments, are excluded. d) The manufacturer is not liable for lost data or retrieval of lost data in cases of slight and ordi-
nary negligence. e) In the case that the intentional or culpable negligence of the manufac turer's employees has
caused a loss of data, the manufacturer will be liable for those costs typical to the recovery
of data where periodic security data back-ups have been made. f) The warranty is valid only for the first purchaser and is not transferable. g) The court of jurisdiction is located in Aachen, Germany in the case that the purchaser is a
merchant. If the purchaser does not have a court of jurisdiction in the Federal Republic of
Germany or if he moves his domicile out of Germany after conclusion of the contract, the
manufacturer's court of jurisdiction applies. This is also applicable if the purchaser's domi-
cile is not known at the time of institution of proceedings. h) The law of the Federal Republic of Germany is applicable. The UN commercial law does
not apply to dealings between the manufacturer and the purchaser.
Conrad Powerline Adapter PL500D duo
Loading...