Connerton CSP-18-3 Installation Manual

Installation, Operation & Maintenance
Fine Cooking Equipment For Over 65 Years
Instructions
CSP SERIES STOCK POT STOVES
For Your Safety
Do NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this, or any other equipment.
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment.
To Purchaser
After installation of your stove, immediately contact your local gas supplier to obtain information in the event the user of your equipment smells gas. This information must be posted in a prominent location.
To User
RETAIN THIS MANUAL FOR FUTURE USE
Upon receipt of this stove, inspect it thoroughly for any damage which may have occurred during shipment. If damage is observed, contact the delivery agency immediately.
Warning!
1. Preparation For Installation:
extent, upon it’s proper installation. It should be installed in accordance with the National Fuel Gas Code , these instructions, and applicable State and Local Codes.
Installation must be made by a licensed plumber.
supply off. Install regulator in a drip-free area.
The stove and it’s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa).
The stove must be isolated from the gas supply piping system by closing it’s individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa).
2. Clearances And Ventilation:
with 0 inch clearance from sides and back.
Z223.1
Safe and satisfactory operation of the stove depends, to a great
Please note: air vent can plug with grease, thereby shutting gas
This stove is designed for installation in non-combustible locations
The Connerton Company
1131 E. Wakeham Avenue, Santa Ana, CA 92705-4145
Telephone: (714) 547-9218 Fax: (714) 547-1969
www.connertoncompany.com
Keep equipment area free and clear from combustibles.
The area in front of, and above the stove must be clear to avoid obstruction of flow of combustion and ventilation air. Means must be provided for adequate air supply and adequate clearance for air openings into the combustion chamber.
Adequate clearances must be provided in front and sides of the stove for servicing and proper operation.
It is important that the stove be installed under an exhaust hood which is adequate to remove the products of combustion and cooking vapors. Sufficient make-up air must also be provided to the space where the stove is located to replace that removed through the exhaust hood.
3. Gas Piping:
Connect outlet side of regulator to stove. The regulator is set at 4 inches w.c. on natural gas and 11 inches w.c. on propane gas. A 1/8” pressure tap is provided on the gas manifold at the front of the stove for checking the gas pressure.
grease, thereby shutting gas supply off. Install regulator in drip-free area.
Connect stove to the gas supply line. Under no circumstances should the gas supply line be smaller than the inlet pipe on the stove. A gas shutoff valve must be installed in the gas supply line upstream of the stove for complete shutdown and service. Use pipe sealant on all pipe joints. Sealant must be resistant to the action of L.P. gasses.
For proper performance, the stove must be level. If legs are provided, adjust feet at bottom of legs to level stove. If legs are not provided, seal the base of the stove to the countertop with silicone.
If the stove is supplied with casters, the installation must be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances , and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, . Adequate means must be provided to limit the movement of the stove without depending on the connector and the quick-disconnect device or it’s associated piping to limit the stove movement. Restraining device should be connected to legs or back of body.
IMPORTANT: Check all gas connections for leaks, using a soap and water solution.
DO NOT USE AN OPEN FLAME FOR CHECKING PURPOSES
4. Lighting And Relighting Of Stove:
Make sure the gas pressure regulator supplied with the stove is installed correctly.
Please note: air vent on regulator can plug with
ANSI Z21.69
ANSI Z21.41
A.
Turn all burner valves and lighter valves to “OFF”. Wait 5 minutes.
B.
Turn on lighter valves and light pilots. Adjust flame height to approximately 1/2”.
C.
Turn on burner valves to operate your stove.
D.
For complete shutdown, turn off all valves and the gas shutoff valve located upstream of the
stove.
E.
To relight, repeat above procedures.
5. Care And Maintenance:
Contact factory, factory representative, or a local service company to perform maintenance and repairs.
A.
B.
C.
Please Note: Contact factory before any warranty repairs are made.
To clean top grate, use warm water, a mild cleanser and wire brush.
At least once per day, clean and empty drip pan.
Periodically, but not less than once every 3 months, clean burner orifices using warm water
and wire brush. Make sure equipment is cold before removing burners and orifices.