IMPORTANT! Read and save these instructions. This manual to be left with the equipment.
2588705_A_EN_1811_UB_IOM
INSTALLATION, OPERATION,
AND MAINTENANCE MANUAL
Ultrasonic Blower Pack
US-Series
Humidification and Evaporative Cooling
Page 2
Thank you for choosing Condair
Installation date (DD/ MM / YYYY):
Commissioning date (DD / MM / YYYY):
Site:
Model:
Serial number:
Proprietary Notice
This document and the information disclosed herein are proprietary data of Condair Ltd. Neither this
document, nor the information contained herein shall be reproduced, used, or disclosed to others
without the written authorization of Condair Ltd., except to the extent required for installation, operation
or maintenance of the customer's equipment.
Liability Notice
Condair Ltd. does not accept any liability due to incorrect installation, maintenance or operation of the
equipment, or due to the use of parts/components/equipment that are not authorized by Condair Ltd..
Copyright Notice
Copyright 2018, Condair Ltd., All rights reserved.
Technical modification rights reserved.
Page 3
CONTENTS
1Introduction5
1.1Before You Start5
1.2General5
1.2.1Limitations of the Manual5
1.2.2Symbols Used in This Manual5
1.2.3Storage of Manual5
1.2.4Available Manuals and Languages6
1.3Receiving and Storage6
1.3.1Inspection6
1.3.2Storage, Packaging, and Transportation6
1.4Safety Precautions7
1.5Compliance7
2For Your Safety8
3Hygiene10
3.1Important Notes on Hygiene10
3.2Hygiene Risk Management10
3.2.1Guidelines to Keep a Clean System and Prevent Micro-organism Growth10
3.3Risk Monitoring and Assessment11
4Product Description12
4.1General Description12
4.2Model Designation12
4.3Functional Description13
4.4Options14
4.5Accessories15
5Product Specifications16
5.1Technical Data16
5.1.1Capacity16
5.1.2Weights16
5.1.3Dimensions16
6Specification Drawings17
7Installation and Planning18
7.1General18
7.1.1Installation Overview19
7.2Location Requirements20
7.3Clearance Requirements20
7.4Site Requirements22
7.4.1Mounting Requirements22
7.4.2Flexible Tube Requirements22
7.4.3Power Supply Requirements22
7.5Installation23
7.5.1Safety23
7.6Remote-Mounted Installation24
7.7Direct-Mounted Installation29
UB
2588705_A_EN_1811_UB_IOM
Contents|3
Page 4
8Operation34
8.1General34
8.2Starting Up34
8.3Shutting Down the Unit34
9Maintenance35
9.1General35
9.2Cleaning and Disinfecting35
9.3Maintenance List36
10Troubleshooting38
10.1General38
10.2General Troubleshooting38
11Spare Parts List: Ultrasonic Blower40
12Commissioning43
12.1General43
12.2First-time Commissioning43
13Decommissioning44
13.1General44
13.2Removing Unit from Service44
13.3Disposing or Recycling the Unit44
AAppendix:Installation Checklist46
Contents|4
2588705_A_EN_1811_UB_IOM
UB
Page 5
1Introduction
1.1Before You Start
Thank you for purchasing the Ultrasonic Blower Pack.
The Ultrasonic Blower Pack incorporates the latest technical advances and meets recognized safety
standards. Improper use of the Ultrasonic Blower Pack may result in danger to the user or third parties,
and/or damage to property.
To ensure safe, proper, and efficient operation of the Ultrasonic Blower Pack, please observe and comply with all information and safety instructions contained in this manual, as well as all relevant documentation of components of the installed humidification system.
If you have additional questions, please contact your Condair representative. They will be glad to assist
you.
1.2General
1.2.1Limitations of the Manual
The subject of this manual is the Ultrasonic Blower Pack. It is intended as a supplement to the Ultrasonic Humidifier installation, operation and maintenance manuals.
This manual is restricted to the installation, operation, and maintenance of the Ultrasonic Blower Pack.
This manual is intended for well trained personnel who are suitably qualified for their respective tasks.
1.2.2Symbols Used in This Manual
CAUTION!
The catchword "CAUTION" in conjunction with the general caution symbol is used to provide safety
instructions that, if neglected, may cause damage and/or malfunction of the unit or damage to property.
WARNING!
The catchword "WARNING" in conjunction with the general warning symbol is used to provide safety
instructions that, if neglected, may cause injury to personnel. Other specific warning symbols may also
be used in place of the general symbol.
Danger!
The catchword "DANGER" in conjunction with the general danger symbol is used to provide safety
instructions that, if neglected, may cause severe injury to personnel or even death. Other specific
danger symbols may also be used in place of the general symbol.
1.2.3Storage of Manual
Keep this manual in a place where it is safe and readily accessible. If the equipment is moved to
another location, please ensure that it remains with the equipment.
If the manual is lost or misplaced, please contact your Condair representative for a replacement.
UB
2588705_A_EN_1811_UB_IOM
Introduction|5
Page 6
1.2.4Available Manuals and Languages
Table 1: Document (Part) Numbers and Languages of Available Manuals
Installatio n
Manual
Operation and
Maintenan ce
Manual
Installatio n,
Operation, and
Maintenan ce
Manual
Spare Parts
List
Engineering
Manual
Ultrasonic
Humidifier US
Ultrasonic
Blower Pack
UB
2588786_A_EN_
1811_US_IM
——
2588787_A_EN_
1811_US_OM
1.3Receiving and Storage
1.3.1Inspection
After receiving the shipment, inspect the goods as follows:
l Inspect the shipping boxes for damage. Report any shipping box damages to the shipping com-
pany without delay.
l Check the goods against the packing slip to ensure that all items have been delivered. Report
any shortages to your Condair representative within 48 hours of receipt of the goods. Condair
does not assume responsibilities for any shortages beyond this period.
l Unpack the parts/components and check for any damage. If parts/components are damaged,
notify the shipping company immediately.
l Verify the model type on the specification label to ensure that it is suitable for your installation.
Refer to "Model Designation" on page12.
1.3.2Storage, Packaging, and Transportation
—
2588705_A_EN_
1811_UB_IOM
2588788_A_EN_
1811_US_SPL
——
—
Storage
Store the Ultrasonic Blower Pack in its original packaging inside a protected area that meets the following requirements until it is installed, or if it needs to be stored for an extended period of time:
l Room temperature: 5 to 40 °C (41 to 104 °F)
l Room humidity: 10 to 95% RH (non-condensing)
Transportation
For optimum protection always transport the unit and components in their original packaging, and use
appropriate lifting/transporting devices.
Packaging
Keep the original packaging of the unit/components for later use.
If the packaging needs to be disposed, observe local regulations on waste disposal. Please recycle
packaging where possible.
6|Introduction
2588705_A_EN_1811_UB_IOM
UB
Page 7
1.4Safety Precautions
Regard all safety precautions described in this manual.
For more information, refer to "For Your Safety" on page8.
1.5Compliance
Follow all local guidelines and regulations regarding the installation and operation of the unit; this
includes (and not limited to) mounting, plumbing, water, gas, ventilation, and electrical connections.
Please consult your local Condair representative to learn more.
UB
2588705_A_EN_1811_UB_IOM
Introduction|7
Page 8
2For Your Safety
General
Every person who is tasked with the installation, operation and/or maintenance of the Ultrasonic Blower
Pack must read and understand this manual, as well as any respective installation, operation and/or
maintenance manuals before performing any work. Knowing and understanding the contents of these
manuals is a basic requirement for protecting personnel against any kind of danger, preventing faulty
operation, and operating the unit safely and correctly.
All labels, signs and markings applied to the Ultrasonic Blower Pack must be observed and kept in a
readable state.
Personnel Qualifications
All procedures described in this document must only be performed by personnel who are adequately
qualified, familiar with the unit, well trained, and are authorized by the customer.
For safety and warranty reasons, any activity beyond the scope of this manual must only be performed
by qualified personnel authorized by Condair.
All personnel working with the Ultrasonic Blower Pack unit must be familiar with, and comply with the
appropriate regulations on workplace safety and prevention of accidents.
Intended Use
The Ultrasonic Blower Pack is intended exclusively for air humidification using a Condair-approved
within specified operating conditions. Refer to "Technical Data" on page16 for details. Any other type of
application, without the express written consent of Condair, is considered to be NOT conforming to its
intended purpose, and may lead to dangerous operation and will void the warranty.
In order to operate the equipment in the intended manner all information contained in this manual, in
particular the safety instructions, must be observed closely.
Safety Precautions that Must be Observed
DANGER!
Risk of electric shock!
The unit is electrically powered by the humidifier. Using the On/Off switch on the humidifier to
shut down the unit will NOT shut off power to the control cabinet. Live parts may be exposed when
the access panels or doors are removed. Touching live parts may cause severe injury or even
death.
Prevention: The unit must be connected to the humidifier only after all mounting and installation work
has been completed and checked for correct workmanship. The humidifier MUST be connected from
the mains only after work has been completed on the humidifier or blower pack, and the access panels/doors are closed and fastened securely.
Only qualified personnel should perform maintenance or repairs on the unit.
Follow any lockout procedures when servicing the unit.
DANGER!
Putting objects or body parts into the fan can result in serious injury or damage to equipment!
The fan consists of rotating blades. Putting objects into the fan will affect the proper functioning of
the unit, causing damage to the object and the equipment, and will become a safety hazard for
people in the vicinity of the unit.
Prevention: Avoid placing objects and body parts into the fan, and if work must be performed, ensure
that the unit is properly shut down.
For Your Safety|8
2588705_A_EN_1811_UB_IOM
UB
Page 9
WARNING!
Risk to Hygiene and Health!
Improper and infrequent maintenance of the unit presents the risk of spreading pathogens (such
as bacteria , viruses, and parasites) originating from contaminated water, air, and equipment. Failure to reduce the risks increases the likelihood of causing injuries (requiring medical care), infection, and death.
Prevention: Use, regularly clean, and replace the air and water inlet filters. Regularly flush and dis-
infect the humidifier, the blower pack, and their components (tanks, hoses, reservoirs, etc.). Use potable, treated water (potable, R.O., or D.I.).
Follow regular maintenance routines as described in "Maintenance List" on page36. Follow local regulations.
WARNING!
Do NOT leave the unit without power. Risk of contamination.
Do NOT leave the unit unpowered for more than 48 hours, or else a total system disinfect will be
required. Without power, the system will not flush properly, resulting in standing water and conditions that may promote the growth of micro-organisms.
Prevention: Leave your unit powered on. If you do not need humidification during the 48 hours, set
the humidifier to standby or set the demand to 0.
Preventing Unsafe Operation
All personnel working with the Ultrasonic Blower Pack and humidifier must immediately report to the
customer any alterations or changes to the unit that may affect safety, and secure the unit against acci-dental power-up.
If it is suspected that the unit cannot be operated safely for any of the reasons listed below, shut it down
immediately.
Alterations and changes that may affect safe operation include:
l damage to the unit
l loose or damaged electrical connections
l improper operation
l leaks in the distribution system
Modifications to the Unit Prohibited
Modifications are NOT permitted on the Ultrasonic Blower Pack without the express written consent of
Condair.
UB
2588705_A_EN_1811_UB_IOM
For Your Safety|9
Page 10
3Hygiene
3.1Important Notes on Hygiene
Observe the local health and safety executive's technical guidance on the control of Legionella in water
systems.
The user is responsible to ensure that the water system complies with local regulations, bylaws, and
guidelines (such as the HSE ACoP L8, VDI 6022, ISO 22000, HACCP, or equivalent). If inadequately
maintained, water systems, of which any humidifier is a part, can support the growth of microorganisms,
including the bacterium responsible for Legionnaires' disease.
Any risks or hazards relating to the system, including during installation and maintenance, should be
identified by a competent health and safety representative who is responsible for introducing effective
control measures.
3.2Hygiene Risk Management
Cold water humidification presents the risk of spreading pathogenic microorganisms into the air. The
Ultrasonic Humidifier and Ultrasonic Blower Pack distribute tiny water droplets (mist) that are blown into
the space before being absorbed into the air. If the mist was contaminated before leaving the unit and
then evaporates, these contaminants are deposited onto surfaces in the space, or are otherwise
inhaled or redistributed into the ventilation system.
Pathogens include, and are not limited to, Legionella, E. coli, and viruses, and may originate from contaminated water, air, and equipment.
Regular cleaning and disinfecting is required to reduce health risks. Refer to "Hygiene Risk Man-
agement" above for more information on managing hygiene hazards.
Follow all safety precautions and local regulations. Refer to "For Your Safety" on page8.
There are multiple points in the humidification system where a contamination can occur. It is the
responsibility of the customer and of Condair to ensure that health hazards due to contamination are
reduced to acceptable levels. The use of a hygiene risk assessor is recommended.
Regularly clean and maintain the humidifier and its components, and do NOT miss or ignore the warnings in this manual and service messages displayed on the humidifier.
Supply Air and Water
Pathogens can originate from the water supply, such as a tank or water line. It is important that standing
water in the tank or in the water line is flushed frequently to prevent the buildup of contaminants, and
the water is filtered and treated.
Pathogens may also enter the humidification system through the ventilation system or from within the
humidifier space. A fan blows air out of the water reservoir into flexible tubes, and further into a blower
pack and into the atmosphere. Contaminated air can join the mist, so it is recommended to use air filters
in the ventilation system, in the humidifier, and in the Ultrasonic Blower Pack. Ensure to use the supplied air filters at all times and replace them regularly (as recommended in the Ultrasonic Humidifier
Maintenance and Operation Manual).
3.2.1Guidelines to Keep a Clean System and Prevent Micro-organism Growth
l Perform a risk assessment of the water system using a competent person, and implement an
appropriate monitoring and control program.
l Connect a RO system to a clean, potable main water supply.
l Ensure that the system is cleaned and/or flushed regularly.
l Ensure that the buffer tank is clean and sterile before use.
l Enter a service contract that suits the needs of the company.
l Stop the system if polluted drinking water is found in the area.
Hygiene|10
2588705_A_EN_1811_UB_IOM
UB
Page 11
l Avoid water temperatures above 20 °C (68 °F). Temperatures between 20-60 °C (68-140 °F)
favor the growth of Legionella.
l Do not stop the system unless it is faulty or leaking (to avoid water stagnation).
l If the power to the system is interrupted (such that the unit fails to flush or drain) for more than 48
hours, complete a total system disinfection.
l Refrain from closing sections of the system, unless there is a leakage or fault (to avoid water
stagnation).
l Disinfect at least once per year, and after every maintenance or repair.
l Analyze the water and test for harmful bacteria at least once per year.
l Conduct follow-up measurements until the system is clean if bacteria has been detected in the
system.
The Condair service team can help with expert technicians who can provide:
l Bacteriological troubleshooting on-site*.
l Cleaning and disinfecting.
l Preventative maintenance.
l Repair and fault finding.
l Training and guidance.
Note: * Condair uses a quick method for measuring bacterial activity in the water with the use of
BactiQuant (BQ). Once the water sample has been taken, the bacteriological quality of the water is read
within 30 minutes, and the Condair service team will disinfect the system if necessary.
Please contact your local Condair representative for further information about our services.
3.3Risk Monitoring and Assessment
Water hygiene assessments must be performed at the site to determine the risk and severity of hygiene
hazards that affect the health and safety of the public. Performing a risk assessment with regular monitoring will allow procedures to be adjusted.
Ensure that the person conducting the assessment is qualified.
A typical assessment inspects the following:
l Supply water quality. Refer to "Technical Data" on page16.
l Environment around the humidifier.
l Maintenance procedures. Refer to "Maintenance List" on page36.
l Water pre-treatment options (such as using UV light, using reverse osmosis or deionized water,
etc.).
Proper maintenance procedures along with recommended site controls will help ensure compliance to
local regulations and protect the public.
It is recommended to monitor the humidification system weekly, and then monthly once satisfactory
levels are maintained.
Ensure that the results of every assessment is recorded.
IMPORTANT! Failure to make adequate provision against the outbreak of disease, such as Legionnaires' disease, may cause fatalities, illness, and liabilities.
UB
2588705_A_EN_1811_UB_IOM
Hygiene|11
Page 12
4Product Description
1
1
1
2
2
1
2
4.1General Description
The Ultrasonic Blower Pack is used along with an atmospheric mist generating humidifier to distribute
very fine water droplets directly into local areas or into spaces that do not have a built-in air distribution
system. The Ultrasonic Blower Pack must be mounted directly on the Ultrasonic Humidifier, or remotely
mounted on suitable surfaces in the space. Large ultrasonic humidifiers, with capacities 18 kg/h (40
lb/h) use two Ultrasonic Blower Pack units. Refer to Figure 1 - below.
Figure 1 - Ultrasonic Blower Pack Typical Remote and Direct Mounted Installations
1. Ultrasonic Blower Pack
2. Flexible tube
4.2Model Designation
The specification label on the top face of the Ultrasonic Blower Pack shows its model type, serial number, manufacturing date, and electrical rating.
l two 24 VDC fans (one top fan and one bottom fan)
l an optional air filter kit (comes with 4 metal-framed filters)
l a pressurized box
l a mist channel
When the Ultrasonic Humidifier is powered on, the safety relay closes and permits the humidifier to generate mist when it receives a demand signal. The Ultrasonic Blower Pack is controlled through the control board of the Ultrasonic Humidifier and receives an ON or OFF signal. The mist is generated in the
ultrasonic humidifier and travels through the connection tubes to the blower pack. From there, the mist
travels through the blower pack's mist channel and is discharged through the front of the blower pack.
The exiting mist is propelled into the space by the air blown out from the pressurized box. The turbulent
air causes mixing and quick absorption between the blown out air and mist streams.
Blower pack fans provide feedback to the ultrasonic humidifier through the connection cable. This feedback allows the humidifier to cease mist generation when a blower pack fan fails. This allows the entire
system to shut down safely and avoids wetting in the space. A warning message "Blower pack not connected" will display on the humidifier LCD display.
UB
2588705_A_EN_1811_UB_IOM
Product Description|13
Page 14
1
1
2
2
9
6
5
4
7
8
3
11
10
Figure 3 - Ultrasonic Blower Pack Components
1. Side panel
2. Foam filter and frame, side, assembly (optional)
3. Adjustable leg (to level the units that are remote-mounted)
4. Specification label (see "Model Designation" on page12)
5. Mist channel
6. Fan assembly
7. Pressurized box
8. Front panel
9. Terminal block
10. Wall mount bracket (for remote installation)
11. * Foam filter and frame, assembly (optional), top
4.4Options
Options for the Ultrasonic Blower Pack:
l Air filter assembly
(PN: 2588764)
l Flexible Tubes.
(PN: 2594413 flexible tube for remote mount)
(PN: 2594409 flexible tube for direct mount)
14|Product Description
2588705_A_EN_1811_UB_IOM
UB
Page 15
4.5Accessories
Accessories for the Ultrasonic Blower Pack:
l Wall mounting brackets (supplied) to mount the unit remotely.
l Ultrasonic Blower Pack Installation, Operation, and Maintenance Manual (P/N:2588705_A_
EN_1811_UB_IOM) (supplied).
UB
2588705_A_EN_1811_UB_IOM
Product Description|15
Page 16
5Product Specifications
5.1Technical Data
5.1.1Capacity
Table 2: Ultrasonic Blower Pack Capacity
ModelCapacity
UB 73 kg/h (6.6 lb/h)90 W
UB 136 kg/h (13.2 lb/h)90 W
UB 209 kg/h (19.8 lb/h)90 W
Note: The large Ultrasonic Humidifier, US 40, is equipped with dual stainless steel reservoirs –
each with its own dedicated driver board. The large unit must be equipped with two Ultrasonic
Blower Packs.
5.1.2Weights
Table 3: Ultrasonic Blower Pack Packaged Weight
ModelWeight
Ultrasonic Blower Pack (allmodels)17.7 kg (39lb)
5.1.3Dimensions
Table 4: Ultrasonic Blower Pack Dimensions
ModelDimensions
Ultrasonic Blower Pack (allmodels)371 x 483 x 432 mm
height x width x depth
(14.6 x 19.0 x 17.0 in)
Product Specifications|16
2588705_A_EN_1811_UB_IOM
UB
Page 17
6Specification Drawings
A
B
C
D
E
G
H
K
J
L
I
ON
M
F
P
Q
R
S
Figure 4 - Ultrasonic Blower Pack Overall Dimensions in millimeters and (inches)
A. 409 (16.1)
B. 428 (16.8)
C. 470 (18.5)
D. 375 (14.8)
E. 339 (13.3)
F.432 (17)
G. 180 (7.1)
H. 80 (3.1)
I.48 (1.9)
J.90 (3.5)
K. 92 (3.6)
L. 78 (3.1)
M. 55 (2.2)
N. 235 (9.3)
O. 148 (5.8)
P. 417 (16.4)
Q. 228 (9)
R. 228 (9)
S. Inner Diameter 74 (2.9); Outer Diameter 78 (3.1)
Product Specifications|17
2588705_A_EN_1811_UB_IOM
UB
Page 18
7Installation and Planning
7.1General
Strictly observe and perform all installation tasks including the mounting of the unit and connection of
the water and power supplies as described in this manual. Observe and comply with all local and
national codes dealing with water and electrical installations. Condair does not accept any liability for
installation of humidification equipment by unqualified personnel, or the use of equipment and parts
that are not authorized by Condair.
Personnel Qualifications
All installation work must be performed only by licensed personnel authorized by the customer. It is the
customer’s responsibility to verify qualifications of the personnel.
Safety
Observe the following safety precautions:
DANGER!
Risk of electric shock!
The unit is electrically powered by the humidifier. Using the On/Off switch on the humidifier to
shut down the unit will NOT shut off power to the control cabinet. Live parts may be exposed when
the access panels or doors are removed. Touching live parts may cause severe injury or even
death.
Prevention: The unit must be connected to the humidifier only after all mounting and installation work
has been completed and checked for correct workmanship. The humidifier MUST be connected from
the mains only after work has been completed on the humidifier or blower pack, and the access panels/doors are closed and fastened securely.
Only qualified personnel should perform maintenance or repairs on the unit.
Follow any lockout procedures when servicing the unit.
DANGER!
Putting objects or body parts into the fan can result in serious injury or damage to equipment!
The fan consists of rotating blades. Putting objects into the fan will affect the proper functioning of
the unit, causing damage to the object and the equipment, and will become a safety hazard for
people in the vicinity of the unit.
Prevention: Avoid placing objects and body parts into the fan, and if work must be performed, ensure
that the unit is properly shut down.
WARNING!
Risk to Hygiene and Health!
Improper and infrequent maintenance of the unit presents the risk of spreading pathogens (such
as bacteria , viruses, and parasites) originating from contaminated water, air, and equipment. Failure to reduce the risks increases the likelihood of causing injuries (requiring medical care), infection, and death.
Prevention: Use, regularly clean, and replace the air and water inlet filters. Regularly flush and dis-
infect the humidifier, the blower pack, and their components (tanks, hoses, reservoirs, etc.). Use potable, treated water (potable, R.O., or D.I.).
Follow regular maintenance routines as described in "Maintenance List" on page36. Follow local regulations.
UB
2588705_A_EN_1811_UB_IOM
Installation and Planning|18
Page 19
WARNING!
1
1
1
4
5
3
6
7
2
2
1
2
Do NOT leave the unit without power. Risk of contamination.
Do NOT leave the unit unpowered for more than 48 hours, or else a total system disinfect will be
required. Without power, the system will not flush properly, resulting in standing water and conditions that may promote the growth of micro-organisms.
Prevention: Leave your unit powered on. If you do not need humidification during the 48 hours, set
the humidifier to standby or set the demand to 0.
7.1.1Installation Overview
The Ultrasonic Blower Pack can be installed remotely with any Ultrasonic Humidifier, or mounted directly onto the Ultrasonic Humidifier (large units excluded -- the Ultrasonic Blower Pack can only beinstalled remotely on large Ultrasonic Humidifiers). Direct-mounting is currently unavailable for large
Ultrasonic Humidifiers. Figure 5 - below shows typical mounting configurations of the Ultrasonic Blower
Pack and humidifier. Learn how to install the unit in "Installation " on page23.
Figure 5 - Ultrasonic Blower Pack Typical Installation with the Humidifier (Medium Humidifier
Shown)
1. Ultrasonic Blower Pack
2. Flexible tubes
3. Electrical disconnect
4. Air gap funnel (for drain line)
5. Trap
19|Installation and Planning
6. Expansion tank (optional)
7. R.O. system
Note: The drain line should have a minimum internal diameter of 22 mm (7/8 in), with a constant
downslope (minimum 1.2°) to the air gap funnel, and must not touch the sides or bottom of the funnel.
Use stainless steel or plastic pipe if using D.I. or R.O.water.
Note: Flexible tubes should be as short as possible – the maximum length varies depending on the
humidifier capacity and material used (refer to "Model Designation" on page12). The flexible tube must
2588705_A_EN_1811_UB_IOM
UB
Page 20
have a constant slope (minimum incline of 10° or minimum decline of 2°), and have no restrictions in
the line, and be no longer than 2 m in equivalent length (ex. bends in the tubing affect the equivalent
length).
Note: Flexible tubes must not merge. Merging multiple tubes to supply an individual blower pack will
lead to water droplets forming inside the mist channel and the risk of spitting out, wetting the floor in
front of the unit, any adjacent equipment, and walls. If a humidifier capacity higher than 9 kg/h (19.8
lb/h) is needed, use a separate Ultrasonic Blower Pack (one for each 9 kg/h (19.8 lb/h) required).
7.2Location Requirements
The installation of the Ultrasonic Blower Pack depends largely on the location of the Ultrasonic Humidifier.
For medium size Ultrasonic Humidifiers, the Ultrasonic Blower Pack may be mounted directly on the
unit, or it may be installed remotely. For large size Ultrasonic Humidifiers, the Ultrasonic Blower Pack
may only be installed remotely and connected by flexible tubes. To reduce condensate losses in remote
installations, Condair recommends installing the Ultrasonic Blower Pack as close to the humidifier as
possible. Distances longer than an equivalent straight-length of 2 m (6.6 ft) reduces the mist output
drastically. Refer to "Mounting Requirements" on page22.
Refer to the Ultrasonic Humidifier Installation Manual (P/N: 2588786_A_EN_1811_US_IM).
The clearance requirements ensure that mist does not come into contact with any surfaces before it is
absorbed into the air. Refer to "Clearance Requirements" below.
IMPORTANT! For installations where the humidified space is separate from the humidifier, ensure that
there is adequate air flow to the humidifier, and adequate air flow out of the space to be humidified,
such that the atmospheric pressure in these spaces are equal. For example, if the humidifier is in a
separate room from the Ultrasonic Blower Pack, provide air from the humidified space to the air intake
of the humidifier.
7.3Clearance Requirements
The clearances for the Ultrasonic Blower Pack in Figure 6 - on the next page and in Table 5 on the next
page are shown for reference only, and are the minimums required for the proper functioning of the
equipment. Consult local and national installation codes. Condair does not accept responsibility for violations of installation codes.
Adjacent Ultrasonic Blower Pack units should be separated by distance, D. For clearance requirements
for the Ultrasonic Humidifier, consult the Ultrasonic Humidifier Installation Manual (P/N:2588786_A_
EN_1811_US_IM).
Table 5: Clearances for the Ultrasonic Blower Pack
DimensionsUS 7, 13, 20
(medium housin g)
A3.7 m (12 ft)3.7 m (12 ft)
B0.5 m (1.5 ft)0.5 m (1.5 ft)
C1.8 m (6 ft)1.8 m (6 ft)
D0.8 m (2.5 ft)0.8 m (2.5 ft)
E *2 m (7 ft)2 m (7 ft)
US 40
(large housing )
The minimum clearances are based on nominal conditions of 22 °C (72 °F) at 30% RH, for the US 20
unit.
* Maximum equivalent straight length of flexible tubes.
21|Installation and Planning
2588705_A_EN_1811_UB_IOM
UB
Page 22
7.4Site Requirements
X
X
>30°
7.4.1Mounting Requirements
□
The selected location for the humidifier and blower pack should meet the requirements
described in "Location Requirements" on page20 and "Clearance Requirements" on page20.
□
The Ultrasonic Blower Pack is designed for wall-mounting in protected interiors. The mounting
surface (wall, pillar, etc.) for the Ultrasonic Blower Pack and humidifier must offer a sufficiently
high load-bearing capacity, and be suitable for the installation. Refer to "Technical Data" on
page16.
□
The Ultrasonic Blower Pack must be level.
□
The Ultrasonic Blower Pack must only be installed and operated in a drip-proof location within
buildings, where the permissible ambient temperature and humidity conditions are maintained.
Refer to "Technical Data" on page16 for details.
□
The Ultrasonic Blower Pack should not be mounted on hot or very cold surfaces, near vibrating
components, or on the floor.
□
The Ultrasonic Blower Pack should not be used as a ducted blower. The air volume from the
Ultrasonic Blower Pack is not sufficient for proper operation in a ducted system.
7.4.2Flexible Tube Requirements
l An optional kit is available (see Ultrasonic Humidifier Spare Parts List) that contains a 2 m (78
in) flexible tube.
l The length of flexible tubes must be kept as short as possible. Exceeding an equivalent length of
2m (3.3ft) will adversely affect the performance of the unit and void the warranty.
l Maintain a constant inner diameter of 80 mm (3.15 in) within the connection.
l Flexible tubes should allow condensate to flow back to the humidifier (otherwise, use con-
densate traps for drainage along the connection).
l Connections must be tight.
l Avoid sharp bends in the connection. The suggested maximum bend should not exceed 30° .
l Avoid horizontal sections in the connection to reduce standing water and inhibit organic growth
in the humidifier and distribution system.
l Avoid merging flexible tubes.
Figure 7 - Avoid horizontal sections and merging flexible tubes
7.4.3Power Supply Requirements
l The Ultrasonic Blower Pack is powered by the humidifier; 90 W at 24 VDC. The power require-
ments are indicated on the specification label on the top face of the unit. Refer to "Model Desig-
nation" on page12.
UB
2588705_A_EN_1811_UB_IOM
Installation and Planning|22
Page 23
7.5Installation
The Ultrasonic Blower Pack can be installed directly onto a medium sized Ultrasonic Humidifier, and
can be installed remotely for any Ultrasonic Humidifier.
l To learn how to mount the unit remotely, refer to "Remote-Mounted Installation" on the facing
page.
l To learn how to mount the unit directly (on a medium humidifier), refer to "Direct-Mounted Install-
ation" on page29.
7.5.1Safety
Observe all safety precautions and comply with local installation codes. Refer to "For Your Safety" on
page8.
23|Installation and Planning
2588705_A_EN_1811_UB_IOM
UB
Page 24
7.6Remote-Mounted Installation
The electrical installation work requires removal of the covers on the Ultrasonic Blower Pack and door
panels of the humidifier.
Before proceeding with the installation, Condair recommends that you familiarize yourself with flexible
tube installation on the humidifier. Refer to the Ultrasonic Humidifier Installation Manual.
Please observe the following:
l All electrical installation work must be performed only by skilled and qualified technical per-
sonnel (e.g. electrician with appropriate training) authorized by the customer. It is the customer’s
responsibility to verify qualification of the personnel.
l The electrical installation must be performed according to the wiring diagrams in the humidifier
manual and this manual, the instructions in this section, as well as applicable local and national
regulations.
l Make sure that the available voltage and phase of the power supply match the requirements for
the blower pack, as indicated on the specification label. Refer to "Model Designation" on
page12.
l All cables must lead into the unit through appropriate cable feed-throughs and must be secured
with clamp straps.
l Cables must be secured with tie wraps (supplied) to prevent rubbing on any components, or
become a tripping hazard.
l Observe local and national codes for maximum cable length and required wire sizes for cables.
Please note the following warnings:
DANGER!
Risk of electric shock!
The unit is electrically powered by the humidifier. Using the On/Off switch on the humidifier to
shut down the unit will NOT shut off power to the control cabinet. Live parts may be exposed when
the access panels or doors are removed. Touching live parts may cause severe injury or even
death.
Prevention: The unit must be connected to the humidifier only after all mounting and installation work
has been completed and checked for correct workmanship. The humidifier MUST be connected from
the mains only after work has been completed on the humidifier or blower pack, and the access panels/doors are closed and fastened securely.
Only qualified personnel should perform maintenance or repairs on the unit.
Follow any lockout procedures when servicing the unit.
CAUTION!
Electrostatic discharge (ESD)!
The electronic components inside the control cabinet in the humidifier are sensitive to electrostatic discharge (ESD).
Prevention: Take appropriate measures to protect the electronic components inside the unit against
damage caused by electrostatic discharge (ESD). Refer to ANSI/ESD-S20.20.
DANGER
Risk of electric shock!
Touching live parts may cause severe injury or even death.
Prevention: DONOT plug the unit into a wall outlet until all installation work has been completed and
checked.
UB
2588705_A_EN_1811_UB_IOM
Installation and Planning|24
Page 25
1. Mount the Ultrasonic Blower Pack. Refer to "Location Requirements" on page20 and "Clear-
ance Requirements" on page20.
a. Locate a 2×4 wooden stud or equivalent support in the mounting surface, and mark the
position with the help of a level – refer to Figure 8 - on the facing page.
b. Install the wall bracket to the wall with mounting screws strong enough to support the
weight of the Ultrasonic Blower Pack. Refer to "Technical Data" on page16.
c. Rotate the interlocks on the side of the unit outwards to unlock them.
d. Lower the Ultrasonic Blower Pack onto the wall bracket.
e. Twist the adjustable legs to adjust their lengths and ensure that the Ultrasonic Blower Pack
is level.
f. Return the interlocks to their locked position.
25|Installation and Planning
2588705_A_EN_1811_UB_IOM
UB
Page 26
3
4
2
2
1
1
3
4
5
Figure 8 - Remote Mounting the Ultrasonic Blower Pack
1. Interlock (supplied)
2. Adjustable Leg (supplied)
3. Wall Bracket (supplied)
4. Wall
5. Mounting Screw (supplied)
2. Connect the flexible tubes. Refer to "Flexible Tube Requirements" on page22.
IMPORTANT! Use gloves and keep the system clean during installation.
a. Remove the clamp from the flexible tube. This will allow the flexible tube to pass
through the top of the humidifier cabinet.
UB
2588705_A_EN_1811_UB_IOM
Installation and Planning|26
Page 27
b. Route the 'connecter' end (item 3) of the flexible tube to the top of the water reservoir.
2
1
3
A
B
Secure the connection by gently inserting the connector and tube into the reservoir, as
seen in Figure 9 - below.
If the Ultrasonic Blower Pack is directly mounted on the humidifier, the mist channel connection extends through the top of the humidifier, into the plumbing cabinet.
c. Route the 'clamp' end (item 1) of the flexible tube through the top of the humidifier.
d. Place the 'clamp' end (item 1) of the flexible tube over the base of the mist channel in the
Ultrasonic Blower Pack. Ensure that there are no horizontal sections in the tube, then
secure the connection by using clamps.
e. Test the unit and check for leaks once installation is complete.
3. Connect the power supply and security loop cables.
a. (If applicable) Plug the power and security loop cables into the back of the Ultrasonic
Blower Pack. The unit should be shipped with these wires already installed to the terminal
block.
2588705_A_EN_1811_UB_IOM
UB
Page 28
VDC
GND
F1
F2
F2
F1
CN4
C
N
6
C
N
1
1
C
N2
4
C
N2
3
O
N
/
O
F
F
B
LO
W
E
R
L
IM
IT
C
O
N
T
RO
L
V
o
ut
IN
G
N
D
I
N
G
N
D
+
2
4
V
I
N
+
2
4
V
I
N
D D+
D-
RS485
+
GND T1 T
FAULT
CN1
CN2
RD
RD
BK
YE
BK
RD
RD
X E 2
Y
E
Y
E
R
D
R
D
Y
YE
+
-
FAN-2
FAN-1
ULTRASONIC BLOWER PACK
BLOWER
E
BLOWER
CONTROL
DRIVER BOARD
YE
YE
9
8
BK
BK
V D C
G N D
F 1
F 2
4
4
5
5
6
7
Figure 10 - Power and Security Loop Cables
b. Punch the knockout hole on the top of the Ultrasonic Humidifier.
c. Install the grommet in the knockout hole and route the cables through the grommet.
1. Control cabinet
2. External
3. Driver board
4. Knockout for Ultrasonic Blower Pack wires
5. Knockout for control devices
6. Medium Ultrasonic Humidifier
7. Large Ultrasonic Humidifier
Note: Grommets are required for remote installations.
d. Remove the door panel on the humidifier control cabinet.
e. Run the security loop and power cables along the cable chase and lead the cables
inside the humidifier's electrical cabinet.
f. Insert the cables into the screw-type connector on the control board. Tighten the
screws and ensure that the wires are properly in place.
g. Install and fasten the door panel on the humidifier control cabinet.
4. Perform the checks described in "Installation Checklist" on page46.
UB
2588705_A_EN_1811_UB_IOM
Installation and Planning|28
Page 29
7.7Direct-Mounted Installation
The electrical installation work requires removal of the covers on the Ultrasonic Blower Pack and door
panels of the humidifier.
Before proceeding with the installation, Condair recommends that you familiarize yourself with flexible
tube installation on the humidifier. Refer to the Ultrasonic Humidifier Installation Manual.
Please observe the following:
l All electrical installation work must be performed only by skilled and qualified technical per-
sonnel (e.g. electrician with appropriate training) authorized by the customer. It is the customer’s
responsibility to verify qualification of the personnel.
l The electrical installation must be performed according to the wiring diagrams in the humidifier
manual and this manual, the instructions in this section, as well as applicable local and national
regulations.
l Make sure that the available voltage and phase of the power supply match the requirements for
the blower pack, as indicated on the specification label. Refer to "Model Designation" on
page12.
l All cables must lead into the unit through appropriate cable feed-throughs and must be secured
with clamp straps.
l Cables must be secured with tie wraps (supplied) to prevent rubbing on any components, or
become a tripping hazard.
l Observe local and national codes for maximum cable length and required wire sizes for cables.
Please note the following warnings:
DANGER!
Risk of electric shock!
The unit is electrically powered by the humidifier. Using the On/Off switch on the humidifier to
shut down the unit will NOT shut off power to the control cabinet. Live parts may be exposed when
the access panels or doors are removed. Touching live parts may cause severe injury or even
death.
Prevention: The unit must be connected to the humidifier only after all mounting and installation work
has been completed and checked for correct workmanship. The humidifier MUST be connected from
the mains only after work has been completed on the humidifier or blower pack, and the access panels/doors are closed and fastened securely.
Only qualified personnel should perform maintenance or repairs on the unit.
Follow any lockout procedures when servicing the unit.
CAUTION!
Electrostatic discharge (ESD)!
The electronic components inside the control cabinet in the humidifier are sensitive to electrostatic discharge (ESD).
Prevention: Take appropriate measures to protect the electronic components inside the unit against
damage caused by electrostatic discharge (ESD). Refer to ANSI/ESD-S20.20.
DANGER
Risk of electric shock!
Touching live parts may cause severe injury or even death.
Prevention: DONOT plug the unit into a wall outlet until all installation work has been completed and
checked.
UB
2588705_A_EN_1811_UB_IOM
Installation and Planning|29
Page 30
IMPORTANT! The Ultrasonic Blower Pack CANNOT be direct-mounted on the large Ultrasonic Humid-
VDC
GND
F1
F2
F2
F1
CN4
C
N
6
C
N
1
1
C
N2
4
C
N2
3
O
N
/
O
F
F
B
LO
W
E
R
L
IM
IT
C
O
N
T
RO
L
V
o
ut
IN
G
N
D
I
N
G
N
D
+
2
4
V
I
N
+
2
4
V
I
N
D D+
D-
RS485
+
GND T1 T
FAULT
CN1
CN2
RD
RD
BK
YE
BK
RD
RD
X E 2
Y
E
Y
E
R
D
R
D
Y
YE
+
-
FAN-2
FAN-1
ULTRASONIC BLOWER PACK
BLOWER
E
BLOWER
CONTROL
DRIVER BOARD
YE
YE
9
8
BK
BK
V D C
G N D
F 1
F 2
4
4
5
5
6
7
ifier. For Ultrasonic Blower Pack installations with large units, remotely mount the Ultrasonic Blower
Pack.
1. Punch the knockouts at the top of the humidifier and open the front door panel on the humidifier.
2. Connect the power supply and security loop cables.
a. Route the power and security loop cables through the knockout hole.
b. Place the unit on the humidifier.
i. Avoid pinching the cables when placing the unit on the humidifier.
ii. Align the mist channel with the openings at the top of the humidifier.
c. Open the door panel on the humidifier control cabinet.
d. Wire and connect the power supply and security loop cables to the driver board inside the
humidifier.
Figure 11 - Driver Board Connections
30|Installation and Planning
UB
2588705_A_EN_1811_UB_IOM
Page 31
1. Control cabinet
2. External
3. Driver board
4. Knockout for wires
5. Knockout for control devices
6. Medium Ultrasonic Humidifier
7. Large Ultrasonic Humidifier
3. Fasten the Ultrasonic Blower Pack to the humidifier.
Ultrasonic Blower Pack units can only be direct-mounted on medium Ultrasonic Humidifier
units. .
a. Slowly lower the Ultrasonic Blower Pack and ensure that there are no kinks in any wir-
ing.
b. Align the Ultrasonic Blower Pack mist inlet with the ultrasonic humidifier mist outlet,
and ensure that holes A (on the humidifier) and B (on the blower pack) are aligned, as
shown in Figure 12 - on the next page.
c. From the ceiling of the humidifier, fasten the Ultrasonic Blower Pack to the top of the
humidifier with M4x6 mm screws (supplied). Refer to Figure 12 - on the next page.
From inside the plumbing section of the humidifier, the Ultrasonic Blower Pack's mist
channel should extend beyond the ceiling.
UB
2588705_A_EN_1811_UB_IOM
Installation and Planning|31
Page 32
B
B
B
B
A
A
A
A
B
A
Figure 12 - Direct-mounting the Ultrasonic Blower Pack to the Humidifier
4. Connect the flexible tubes. Refer to "Flexible Tube Requirements" on page22.
IMPORTANT! Use gloves and keep the system clean during installation.
a. Remove the clamp from the flexible tube. This will allow the flexible tube to pass through
the top of the humidifier cabinet.
b. Route the 'connecter' end (item 3) of the flexible tube to the top of the water reservoir.
Secure the connection by gently inserting the connector and tube into the reservoir, as
seen in Figure 13 - on the facing page.
If the Ultrasonic Blower Pack is directly mounted on the humidifier, the mist channel connection extends through the top of the humidifier, into the plumbing cabinet.
c. Route the 'clamp' end (item 1) of the flexible tube through the top of the humidifier.
d. Place the 'clamp' end (item 1) of the flexible tube over the base of the mist channel in the
Ultrasonic Blower Pack. Ensure that there are no horizontal sections in the tube, then
secure the connection by using clamps.
e. Test the unit and check for leaks once installation is complete.
5. Reinstall the door panels on the humidifier cabinet and control cabinet.
6. Perform the checks described in "Installation Checklist" on page46.
UB
2588705_A_EN_1811_UB_IOM
Installation and Planning|33
Page 34
8Operation
8.1General
Personnel Qualifications
The Ultrasonic Blower Pack must only be operated by personnel who are adequately qualified, welltrained, and are authorized by the customer.
Safety
Observe the following safety precautions.
8.2Starting Up
The Ultrasonic Blower Pack is powered through the Ultrasonic Humidifier. Once the Ultrasonic Blower
Pack is installed, the humidifier must be configured to recognize and control the unit. Refer to the Ultrasonic Humidifier Operation and Maintenance Manual.
IMPORTANT! Clean and disinfect the unit if the unit has been unpowered for an extended period of
time (over 48 hours). Refer to "Cleaning and Disinfecting" on page35.
8.3Shutting Down the Unit
The Ultrasonic Blower Pack does not have an On/Off switch. The unit is directly powered by the humidifier. To shut down the Ultrasonic Blower Pack, shut down the Ultrasonic Humidifier.
Strictly observe all safety precautions and perform only the tasks described in this manual. Refer to "For
Your Safety" on page8.
IMPORTANT! Avoid unpowering your unit. To stop humidification, set your demand to 0. This will leave
your unit powered and in 'standby' mode to allow your unit to flush regularly and prevent microbial
growth.
To shut down the Ultrasonic Humidifier:
1. Shut off the water supply to the humidifier.
2. Make a note of the fault code, if any, displayed on the Home screen.
3. Set the On/Off button to the Off position.
4. Wait for the humidifier to drain the reservoir and shut down. The drain valve will remain open for
70 seconds to drain the unit. After this period, the drain valve will close.
5. Disconnect the power supply to the humidifier at the external disconnect switch. To prevent accidental power-up, lock out and tag out.
Operation|34
2588705_A_EN_1811_UB_IOM
UB
Page 35
9Maintenance
9.1General
Strictly observe all safety precautions, and perform only those maintenance tasks described in this
manual. Refer to "For Your Safety" on page8.
Use only original Condair replacement parts.
All maintenance work must be performed only by licensed personnel authorized by the customer. It is
the customer's responsibility to verify qualifications of the personnel.
The maintenance work may require removal of the cover on the unit.
The Ultrasonic Humidifier may need to be unplugged to safely maintain and operate on the unit. Refrain
from unpowering the unit (for more than 48 hours) unless it is deemed necessary, as unpowered units
will not flush.
9.2Cleaning and Disinfecting
Cleaning and disinfecting should be performed by authorized persons. Contact your Condair representative for more details.
Refer to "Maintenance List" on the next page for the general procedure and frequency of maintenance.
Disinfectants are mandatory, and must NOT produce toxic residue. Observe all safety precautions
labeled on the disinfectants and cleaner.
CAUTION!
Risk of damage to the humidifier components!
Do NOT use solvents, aromatized, or halogenized hydrocarbons, or other harsh chemicals for
cleaning.
Do NOT use cleaning materials that could leave scratches on wet, plastic and metal surfaces of
the unit.
Do NOT use hard or metallic brushes to clean the unit.
Condair recommends the following:
l Avoid recontaminating the components. Use clean gloves (that are safe to use with the agents
listed below) when handling components and cleaning agents.
l For cleaning: dish washing soap
l For descaling: citric acid solution
Note: pH 2, or 20g citric acid in 1 L water, or 0.18 lbs for every 1 gallon
l For disinfecting: 0.1% hydrogen peroxide, H
l At the end of each cleaning, allow the humidifier to fill and create mist for 2-3 minutes, then per-
2O2
form a full drain cycle. This should be performed manually or through changing the demand signal (full demand to mist; zero stop mist and allow to drain).
Condair provides a cleaning and disinfecting kit for the Ultrasonic Humidifier (P/N: 2594996)
IMPORTANT! Avoid cleaning with hard or rough materials, such as steel wool, or metal brushes. Abrasions on the surface of any components may prevent micro-organisms from being cleaned easily.
Instead use a clean cloth or soft brush.
Avoid materials that will leave particles behind.
Avoid using a hard, or metal (or otherwise abrasive) brush.
UB
2588705_A_EN_1811_UB_IOM
Maintenance|35
Page 36
To disinfect a component:
1. Review the maintenance instructions for the component that will be cleaned and disinfected.
Specific considerations must be taken into account for some components.
2. Ensure UV assembly is shut down before disinfection.
3. Clean the component with hot water and soap, and rinse with water. Remove biofilms and any
surface impurities. Avoid using hard or metallic brushes (to avoid surface abrasions) to clean
and disinfect.
4. Descale components using citric acid* (pH 2), then rinse with water.
l *Let the component soak for 20 minutes and avoid scrubbing. Do NOT agitate the piezo-
electric transducers because they are very fragile.
5. Apply disinfecting agent (hydrogen peroxide) to the component and allow to air dry (this allows
the agent to penetrate and kill pathogens).
6. Rinse thoroughly with clean water (RO or DI water) to remove residue.
To disinfect hoses:
1. Clean and disinfect hose connections, as described above.
2. Remove any residue or particles from the hoses.
3. Flush the hoses with hot water.
4. Flush the hoses with disinfecting liquid and allow to air dry.
5. Rinse the hoses with clean water (RO or DI water) to remove residue from disinfectant.
9.3Maintenance List
Perform the following maintenance tasks at the intervals specified in Table 6 on the facing page. For the
components referenced in the table, refer to "Spare Parts List: Ultrasonic Blower" on page40.
36|Maintenance
2588705_A_EN_1811_UB_IOM
UB
Page 37
Table 6: Maintenance List
Task/ComponentFrequencyDescription
Check for water leaksWeeklyCheck the humidifier and blower pack for water leaks,
stainsand calcium deposits. If present, identifythe source
of the leak and tighten or replace components, as required.
Vacuum dustWeeklyVacuum the dust from the top of the Ultrasonic Blower
Pack includingthe optional filter (if installed). Dust accumulation can affect performance of the unit.
Replace or clean air filter elementWeekly-MonthlyClean or replace all air filters for air leading to the humidifier
and Ultrasonic Blower Pack. Refer to the specificcleaning/replacement instructions packaged with the air filters.
Check for loose wiringAnnuallyVisually inspect external electricalwiring for loosecon-
nections or damage to the wiring. Repair as appropriate.
Clean the mist channelWeekly-MonthlyUse a wet, non-abrasivecloth to remove any scale, dust or
debris that may have accumulated at the outlet of the distributor assembly. If results from inspections ar e satisfactory (as per your riskassessor), mist channel may be
cleaned monthly.
Remove any dust and debris.
Clean the flexible tubesWeekly-MonthlyUse a wet, non-abrasive cloth to remove any scale, dust, or
debris that may have accumulated on and inside the flexible tubes. If resultsfrom inspectionsare satisfactory (as
per your risk assessor), flexible tubes may be cleaned
monthly.
Clean the fansWeekly-MonthlyVisuallyinspect the fans for a faulty connection or damage.
Repair or replace as appropriate. Clean the fans of any
accumulated dust. If resultsfrom inspectionsare satisfactory (as per your riskassessor), fans may be cleaned
monthly.
Remove any dust and debris.
UB
2588705_A_EN_1811_UB_IOM
Maintenance|37
Page 38
10Troubleshooting
10.1General
Troubleshooting of the Ultrasonic Blower Pack must only be performed by well qualified and well
trained personnel. Electrical repairs must only be performed by a licensed electrician authorized by the
customer, or by Condair service technicians.
Troubleshooting the Ultrasonic Blower Pack may require the user to access the inside of the humidifier
to the control and plumbing cabinets, which may expose the user and equipment to hazards described
in "For Your Safety" on page8.
10.2General Troubleshooting
Ultrasonic Blower Pack fan(s) are not operating
Probable Cause
l No power to blower pack.
l Fan(s) damaged.
Corrective Action
l Check power connection.
l Check the fans for any damage or blockages.
l Make sure that the humidifier operates, and there is a demand for humidity.
Ultrasonic Blower Pack is making unusual noises while running
Probable Cause
l Improper assembly (ex. loose parts in the unit, replacement parts poorly installed, etc.).
l Blockage in front of the fans (in the unit).
l Blockage or dirty air intake filters.
l Damaged fan bearings.
Corrective Action
l Reassemble the Ultrasonic Blower Pack. Ensure any loose parts are secured.
l If there is a blockage, remove and inspect the pressurized box. Check for any debris or
structures that may cause blockages or redirection of the air flow in and out of the fan.
l Check for blockages in the air intake filter. Blockages may be caused by excess dirt in the
filter. Replace the filter(s).
l If the fan bearings are damaged, the fan(s) must be replaced.
Troubleshooting|38
2588705_A_EN_1811_UB_IOM
UB
Page 39
Ultrasonic Blower Pack is spraying or dripping water
Probable Cause
l Ultrasonic Blower Pack is not level.
l Obstructed airflow from the pressurized box (may be caused by damage or blockage).
l Obstructed airflow or dirty surfaces in the mist channel.
Corrective Action
l Level the Ultrasonic Blower Pack with adjustable legs, or re-mount the unit.
l Inspect the fans and pressurized box. Remove any blockages or replace the pressurized
box.
l Clean dirty surfaces and ensure that the surface is smooth and without blockages, espe-
cially at distances up to 70 mm (2.75 in) from the mist outlet.
UB
2588705_A_EN_1811_UB_IOM
Troubleshooting|39
Page 40
11Spare Parts List: Ultrasonic Blower
6
6
1
4
5
6
3
2
Figure 14 - Ultrasonic Blower Pack Spare Parts. Refer to Table 7 on the next page.
UB2588705_A_EN_1811_UB_IOMSpare Parts List: Ultrasonic Blower|40
Page 41
Table 7: Ultrasonic Blower Pack Spare Parts List
ItemPart NumberDescriptionQuantity
SP, F an 1, BP, US Humidifier
Set includes:
12588752
22588753
32588754
2588755
4
2588757
2588758
52588756
l
Fan 1, left-turn (qty. 1)
l
Screw, 3.5 MM (qty. 10)
l
Distributor, box end foam (qty. 3)
SP, F an 2, NP, US Humidifier
Set includes:
l
Fan 2, right-turn (qty. 1)
l
Screw, 3.5 MM (qty. 10)
l
Distributor, box end foam (qty. 3)
SP, F an Assembly, BP, US Humidifier
Set includes:
l
Fan assembly(qty. 1)
l
Screw, 3.5 MM (qty. 4)
l
Screw, M4x10 (qty. 2)
SP, Mist Channel, BP, UB-20
Set includes:
l
Mist channel assembly, UB-20 (qty. 1)
l
Screw, M4x10 (qty. 2)
SP, Mist Channel, BP, UB-13
Set includes:
l
Mist channel assembly, UB-13 (qty. 1)
l
Screw, M4x10 (qty. 2)
SP, Mist Channel, BP, UB-07
Set includes:
l
Mist channel assembly, UB-07 (qty. 1)
l
Screw, M4x10 (qty. 2)
SP, Pressurized Box, BP, US Humidifier
Set includes:
l
Pressurized box(qty. 1)
l
Screw, M4x10 (qty. 4)
1
1
1
1
1
1
1
UB2588705_A_EN_1811_UB_IOMSpare Parts List: Ultrasonic Blower|41
Page 42
ItemPart NumberDescriptionQuantity
SP, F ilter Set, BP,US Humidifier
Set includes:
l
Frame, filter (qty. 2)
62588764
l
Foam, filter (qty. 4)
l
Plunger, snap latch (qty. 2)
l
Grommet, snap latch (qty. 2)
l
Frame, filter side (qty. 2)
N/S2594413Flexible Tube (x1), UB, Remote Mount1
N/S2594409SP. Flexible T ube (x1), UB, Direct Mount1
N/S = Not Shown
1
42|Spare Parts List: Ultrasonic Blower2588705_A_EN_1811_UB_IOMUB
Page 43
12Commissioning
12.1General
The Ultrasonic Blower Pack must be commissioned and operated only by personnel who are
adequately qualified and familiar with the Ultrasonic Blower Pack. It is the customer's responsibility to
verify the qualifications of personnel.
12.2First-time Commissioning
The unit must always be commissioned for the first time by a service technician from your Condair representative, or by personnel who are well trained and authorized by the customer. For this reason, this
manual only provides an outline, and not the details of the commissioning protocol.
The steps are in the following order:
1. Inspect the mounting of the unit.
2. Inspect the mist, water, and drain line installation.
3. Inspect the electrical installation.
4. Configure the Ultrasonic Blower Pack through the humidifier controls.
5. Conduct performance tests, including controls.
6. Fill out the commissioning protocol documents.
UB
2588705_A_EN_1811_UB_IOM
Commissioning|43
Page 44
13Decommissioning
13.1General
If the Ultrasonic Blower Pack needs to be replaced or removed from service for disposal, strictly follow
the instructions in this section.
Personnel Qualifications
All decommissioning work must be performed only by a qualified service technician authorized by the
customer. It is the customer’s responsibility to verify proper qualifications of the personnel.
Safety
The decommissioning work will require removal of the covers/door panels on the Ultrasonic Blower
Pack.
Refer to "For Your Safety" on page8.
13.2Removing Unit from Service
Remove the Ultrasonic Blower Pack from service for disposal, or long-term storage, as follows:
1. Shut down the humidifier. Refer to "Shutting Down the Unit" on page34.
2. Disconnect the humidifier from the power source.
3. Disconnect the control signal inputs (including any power and security loop connections) from
the terminal strips in the humidifier. Refer to Appendix: "WiringDiagram Ultrasonic Blower Pack"
1.
4. Remove the Ultrasonic Blower Pack from its mounting surface.
5. If the unit is to be put in long-term storage, store the unit in its original packaging inside a protected area. Refer to "Receiving and Storage" on page6.
6. If the unit is to be disposed, refer to "Disposing or Recycling the Unit" below.
13.3Disposing or Recycling the Unit
The Ultrasonic Blower Pack and its components must NOT be disposed in domestic waste, and should
only be disposed in accordance with local regulations at authorized collection facilities.
If you have any questions, please contact the appropriate local authorities, or your local Condair representative.
Decommissioning|44
2588705_A_EN_1811_UB_IOM
UB
Page 45
APPENDIX
UB
2588705_A_EN_1811_UB_IOM
Appendix
Page 46
A Appendix:
Installation Checklist
Mounting
□
Unit installed in a suitable location? Refer to "Location Requirements" on page20.
□
Unit installed with suitable clearances? Refer to "Clearance Requirements" on page20.
□
Mounting surface is stable and capable of supporting the full operating weight of the unit? Refer
to "Weights" on page16.
□
Unit is level?
□
Unit is fastened securely?
Flexible Tubes Connection
□
Flexible tubes cleaned?
□
The length of flexible tubes must be kept as short as possible
□
Flexible tubes should allow condensate to flow back to the humidifier (otherwise, use condensate traps for drainage along the connection)
□
The selected location for installation of the Ultrasonic Blower Pack should allow proper routing
of the mist, as described in "Remote Ultrasonic Blower Pack Installation".
Electrical Connection
□
Power supply meet the voltage and current requirements shown on the specification label?
Refer to "Model Designation" on page12.
□
All cables fastened securely?
□
All cables free of tension and pass through any applicable cable glands or grommets?
□
Electrical installation meet the applicable national and local codes?
□
All door panels closed and fastened securely
Installation Checklist|46
2588705_A_EN_1811_UB_IOM
UB
Page 47
Notes:
Page 48
Page 49
Warranty
Condair Inc. and/or Condair Ltd. (hereinafter collectively referred to as THE COMPANY), warrant for a
period of two years after installation or 30 months from manufacturer’s ship date, whichever date is
earlier, that THE COMPANY’s manufactured and assembled products, not otherwise expressly warranted, are free from defects in material and workmanship. No warranty is made against corrosion,
deterioration, or suitability of substituted materials used as a result of compliance with government regulations.
THE COMPANY’s obligations and liabilities under this warranty are limited to furnishing replacement
parts to the customer, F.O.B. THE COMPANY’s factory, providing the defective part(s) is returned freight
prepaid by the customer. Parts used for repairs are warranted for the balance of the term of the warranty
on the original humidifier or 90 days, whichever is longer.
The warranties set forth herein are in lieu of all other warranties expressed or implied by law. No liability
whatsoever shall be attached to THE COMPANY until said products have been paid for in full and then
said liability shall be limited to the original purchase price for the product. Any further warranty must be
in writing, signed by an officer of THE COMPANY.
THE COMPANY’s parts or materials that are considered consumables, including but not limited to: cylinders, filters, nozzles, membranes, media, gaskets, O-rings, etc. are NOT covered by the warranty.
THE COMPANY makes no warranty and assumes no liability unless the equipment is installed in strict
accordance with a copy of the catalog and installation manual in effect at the date of purchase and by a
contractor approved by THE COMPANY to install such equipment.
THE COMPANY makes no warranty and assumes no liability whatsoever for consequential damage or
damage resulting directly from misapplication, incorrect sizing or lack of proper maintenance of the
equipment.
THE COMPANY makes no warranty and assumes no liability whatsoever for damage resulting from
freezing of the humidifier, supply lines, drain lines, or quality of the water used.
THE COMPANY retains the right to change the design, specification and performance criteria of its
products without notice or obligation.
THE COMPANY’s limited warranty on accessories, not of the companies manufacture, such as controls,
humidistats, pumps, etc. is limited to the warranty of the original equipment manufacturer from date of
original shipment of humidifier.
Extended Warranty
Extended warranties are available to purchase under the conditions listed above.
Page 50
CONSULTING, SALES, AND SERVICE:
U.S.A.
835 Commerce Park Drive
Ogdensburg, NY 1366-2209
CANADA
2740 Fenton Road
Ottawa, ON, K1T 3T7
Tel: 1.866.667.8321
Fax: 613.822.7964
Email: na.info@condair.com
Website: www.condair.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.