Please read these instructions prior to using the appliance and save them for future reference.
CP15HW2 Portable Reverse Cycle Air Conditioner
Page 3
INTRODUCTION
1
Page 4
SAFETY
For indoor use only.
Transport the air conditioner in an upright position only, or leave it in an upright position for at least 2 hours before use (Fig 1).
Use only in the upright position on a flat level surface and at least 50cm from any objects.
Do not place objects on the air conditioner, or through the ventilating slots or restrict the air inlets & outlets (Fig 2).
Closely supervise any children and pets when the air conditioner is in use.
Do not store or operate the appliance near any flammable substances.
During operation, water will collect in the bottom tank of the air conditioner. Be careful when moving the unit to prevent water from spilling.
Electrical Safety
Ensure the appliance has been installed in accordance with national wiring regulations.
1
2
2
CP15HW2 Portable Reverse Cycle Air Conditioner
Page 5
4
3
Air Outlet
Control/Display Panel
Remote Reciever
Handle
Drain Pump
Connector
Remote Control
Evaporator
Air Intake
Condenser Air Intake
Evaporator
Drain Plug
Drain Pump
Connector
Release Button
Drain Pump
Outlet
Drain
Cord Storage
Rating Label
Power Cord
Exhaust Hose
Hose End
Exhaust Nozzle
(window end)
3
Page 6
7A
5
7B
6
4
CP15HW2 Portable Reverse Cycle Air Conditioner
Page 7
CONTROL AND DISPLAY PANEL
8
Water Full
Indicator
Power ON / OFF
Green - Cooling Orange - Dehumidify Yellow - Fan Red - Heating
button
Press to turn
the air
conditioner on
and off
Mode Setting
Lights
Mode Select
Press to cycle
from Cooling,
Dehumidifying
Fan and Heating
button
Modes
Fan Speed
Indicator Lights
Low - 1 Light
Medium - 2 Lights
High - 3 Lights
Fan Speed
control button
Press to cycle the fan speed
between low,
medium and
high
Timer
Indicator
Timer Set
button
Press to enter
the timer setting
mode and time
Current Display
Temperature
Indicators
Press to increase,
to decrease the
set temperature
In Timer mode, press
to increase, to
decrease the timer
from 01-24 hours
In Cooling mode, press
at same time to toggle
between °C and °F
NOTE!
To avoid damage to the control panel, do not operate with sharp objects.
5
Page 8
REMOTE CONTROL
Signal transmission point
Power ON / OFF button
9
10
Fan speed adjust button
Mode buttons (Cool-Dehumidify-Fan-Heating)
Battery compartment
Battery cover
NOTE:
WASTE BATTERIES SHOULD
!
BE DISPOSED OF CORRECTLY
6
CP15HW2 Portable Reverse Cycle Air Conditioner
Page 9
7
Page 10
8
CP15HW2 Portable Reverse Cycle Air Conditioner
Page 11
MAINTENANCE
A
11
Remove filter from the air conditioner and clean every 2 weeks.
C
11
Press button to release
11
B
End of season storage:
Drain any water from the unit.
Operate the unit in fan only mode for a few hours, to thoroughly dry the inside.
Clean or change the filter.
Unplug and carefully store the power cord and plug end.
Replace in the original carton or cover for storage.
9
Page 12
TROUBLESHOOTING
Problem Check
The air conditioner does not run.
The air conditioner is not as cool as it once was.
The air conditioner is too noisy.
Is the air conditioner plugged in?
Is there a power failure?
Is the "WATER FULL" error code flashing? Drain the tank as shown (Fig 12).
Is there direct sunshine? Remember to close curtains or blinds.
Are windows or doors open?
More people in the room will generate more heat.
Is there something in the room producing excessive heat?
Is the exhaust fitted correctly or obstructed? All exhaust air needs to be completely removed from the room.
Is the filter dusty or dirty, restricting the airflow?
Is the air inlet or outlet blocked?
Is the room temperature below the set temperature?
Is the air conditioner positioned unevenly, so as to create vibration?
Is the floor beneath the air conditioner uneven?
The compressor will not run.
Never try to dismantle the air conditioner yourself.
In case of problems that cannot be fixed by using the above guide, or if service on your air conditioner is required, please contact your dealer or designated service agent.
10
CP15HW2 Portable Reverse Cycle Air Conditioner
Page 13
Model
Function
Cooling Capacity (Watts)
Heating Capacity (Watts)
Power Supply
Rated Input Power (Watts)
Fuse Type
Refrigerant Type / Charge (kg)
High Side Pressure - Maximum (MPa)
Low Side Pressure - Maximum (MPa)
Water Ingress Protection Rating
Weight (kg)
Dimensions (mm) (width / depth / height)
CP15HW2
Personal Cooling & Heating
4100
3500
440
220-240V ~ 50Hz
1400
3.15A / 250V
R410A / 0.83
3.53
1.77
IPX0
36
510 x 415 x 830
As a policy of continual product improvement, this manual, its contents and specifications are subject to change without notice.
11
Page 14
12
CP15HW2 Portable Reverse Cycle Air Conditioner
Page 15
1300 526 410
Convair Supercool
13
Page 16
Warranty Service
Australia 1-300-526-410
seeleyinternational.com
®
00253801-C
convair.net.au
AU 1505