Comtech EF Data Vipersat CDD-562L, Vipersat CDD-564, Vipersat CDD-564L User Manual

Comtech EF Data is an
AS9100 Rev B / ISO9001:2000 Registered Company
Vipersat
CDD-56X Series
Satellite Network Demodulator Router
CDD-562L
CDD-564/564L
MN/22137 Revision 1
Vipersat CDD-56X Series
CDD-562L, CDD-564/564L
Satellite Network Demodulator Router
User Guide
April 21, 2013
Part number MN/22137
Document Revision 1
Firmware Version 1.6.11/2.6.11
COMTECH EF DATA
VIPERSAT Network Products Group
3215 Skyway Court Fremont, CA 94539 USA
Phone: (510) 252-1462 Fax: (510) 252-1695
www.comtechefdata.com
Part Number: MN/22137 Revision: 1
Firmware Version: 1.6.11/2.6.11
©2013 by Comtech EF Data, Inc. All rights reserved. No part of this manual may be copied or reproduced without prior written permission of Comtech EF Data, Inc.
IMPORTANT NOTE: The information contained in this document supersedes all previously published information regarding this product. Product specifications are subject to change without prior notice.
Comtech reserves the right to revise this publication at any time without obligation to provide notification of such revision. Comtech periodically revises and improves its products and, therefore, the information in this document is subject to change without prior notice. Comtech makes no warranty of any kind with regard to this material, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. No responsibility for any errors or omissions that may pertain to the material herein is assumed. Comtech makes no commitment to update nor to keep current the information contained in this document.
Patents and Trademarks
All products, names and services are trademarks or registered trademarks of their respective companies. See all of Comtech EF Data’s patents and patents pending at
http://patents.comtechefdata.com.
Printed in the United States of America
Document Revision History
Revision Date Description
0 3/10/08 Initial Release
Note: This new document part number, MN/22137, supersedes the previous CDD-56X User Guide part number, 22137.
New functionality in v1.5.4: New DPC enhancements; STDMA Power Hunt; Hitless Switching; New VMS registration and Managing Address method; UDP Port Base Address selection; Auto Home State Failsafe; SOTM.
1 4/21/13 Update content to reflect NP v1.6.11/2.6.11.
New Features: Dynamic Entry Channel Mode (ECMv2).
{ This Page is Intentionally Blank }
Table of Contents i
Chapter 1
General
How to Use This Manual . . . . . . . . . . . 1-1
Manual Organization . . . . . . . . . . . . 1-1
Chapter 1 — General . . . . . . . . . 1-1
Chapter 2 — Quick Start Configuration 1-1 Chapter 3 — Using the Command Line
Interface (CLI) . . . . . . . . . . . . 1-2
Appendix A — Network Addressing . . 1-2 Appendix B — Automatic Switching . . 1-2 Appendix C — Dynamic Power Control1-2
Appendix D — ECM Migration . . . . . 1-2
Appendix E — Glossary . . . . . . . . 1-2
Conventions and References . . . . . . . . 1-2
Product Description . . . . . . . . . . . . . . 1-4
Introduction . . . . . . . . . . . . . . . 1-4
Demodulator Features . . . . . . . . . . 1-4
Router Features . . . . . . . . . . . . . 1-4
Network and Bandwidth Management . . 1-5
Dynamic SCPC (dSCPC) . . . . . . . . 1-5
STDMA . . . . . . . . . . . . . . . . . 1-6
Single Hop On Demand . . . . . . . . . 1-6
Turbo Product Coding . . . . . . . . . . 1-6
Header Decompression . . . . . . . . . 1-6
Payload Decompression. . . . . . . . . 1-7
Data Decryption . . . . . . . . . . . . . 1-7
New in This Release. . . . . . . . . . . . . 1-7
1.6.11/2.6.11 Release . . . . . . . . . . 1-7
Dynamic Entry Channel Mode . . . . . 1-7
Customer Support . . . . . . . . . . . . . . . 1-8
Contact Information . . . . . . . . . . . 1-8
Return Material Authorization . . . . . . 1-8
Reader Comments / Corrections . . . . 1-8
Chapter 2
Quick Start Configuration
Introduction . . . . . . . . . . . . . . . . . . 2-1
Initial Configuration . . . . . . . . . . . . . . 2-2
Terminal Connection . . . . . . . . . . . 2-2
Network Role . . . . . . . . . . . . . . . . 2-2
Setting Vipersat CDD-56X Operating
Parameters . . . . . . . . . . . . . . . . . 2-3
Set the Feature Configuration . . . . . . 2-3
Set the IP Address . . . . . . . . . . . 2-6
Configure the Route Table . . . . . . . 2-7
Routing in a Vipersat Network. . . . . 2-7
Creating the Routes . . . . . . . . . . 2-8
Set the Satellite Demod Configuration . 2-9
Set the Vipersat Configuration . . . . 2-10
Chapter 3
Using the Command Line Interface
(CLI)
General . . . . . . . . . . . . . . . . . . . . . 3-1
Common Screen Commands . . . . . . . . 3-2
Demod Select . . . . . . . . . . . . . . 3-2
Save Parameters to Permanent Storage 3-2
Exit . . . . . . . . . . . . . . . . . . . 3-2
Telnet Logout . . . . . . . . . . . . . . 3-2
Menu Descriptions . . . . . . . . . . . . . . . 3-3
Main Menu . . . . . . . . . . . . . . . . . 3-3
Administration . . . . . . . . . . . . . . 3-3
Feature Configuration . . . . . . . . . . . . 3-5
Vipersat Feature Codes . . . . . . . . . 3-5
Vipersat Management . . . . . . . . . . 3-6
Vipersat STDMA . . . . . . . . . . . . 3-6
Vipersat Auto Switching . . . . . . . . . 3-6
Vipersat File Streamer. . . . . . . . . . 3-7
Vipersat Configuration . . . . . . . . . . . . . 3-8
STDMA Mode . . . . . . . . . . . . . . . . 3-8
STDMA . . . . . . . . . . . . . . . . . 3-9
STDMA Tx Rate. . . . . . . . . . . . 3-10
Hub Type . . . . . . . . . . . . . . . 3-10
1 – Fixed . . . . . . . . . . . . . . 3-11
2 – Dynamic Slot . . . . . . . . . . 3-11
3 – Dynamic Cycle . . . . . . . . . 3-11
4 – GIR . . . . . . . . . . . . . . . 3-11
5 – Entry Channel . . . . . . . . . . 3-12
6 – ECMv2 . . . . . . . . . . . . . 3-12
ECMv2 Mode . . . . . . . . . . . . . 3-13
Group ID. . . . . . . . . . . . . . . . 3-14
STDMA Max Power Hunt . . . . . . . 3-14
Low Data Rate Fast Acquisition . . . . 3-15
Burstmap Multicast IP . . . . . . . . . 3-15
Outbound IP. . . . . . . . . . . . . . 3-16
Cycles Per Burst Map . . . . . . . . . 3-16
Table of Contents
ii Vipersat CDD-56X Series User Guide
MN/22137, rev 1
Slot Guardband . . . . . . . . . . . . 3-17
Slot Preamble Length . . . . . . . . . 3-18
Slot Data Length. . . . . . . . . . . . 3-18
Nominal Data Length . . . . . . . . . 3-19
Maximum Data Length. . . . . . . . . 3-19
Minimum Data Length . . . . . . . . . 3-20
Total Slot Count . . . . . . . . . . . . 3-20
Slot Cycle Length . . . . . . . . . . . 3-21
Slot Start in Cycle . . . . . . . . . . . 3-21
Set Remotes. . . . . . . . . . . . . . 3-21
Adding a Remote to the STDMA Group .
3-22
Base . . . . . . . . . . . . . . . . . 3-23
Remote Count . . . . . . . . . . . . 3-23
Set Remote Policies . . . . . . . . . 3-24
Delete Remote. . . . . . . . . . . . 3-26
Enable/Disable Remote . . . . . . . 3-27
View Remote(s) . . . . . . . . . . . 3-27
Remove Timeout . . . . . . . . . . 3-28
Remove Retry Timeout . . . . . . . 3-28
LNB LO Frequency . . . . . . . . . . 3-29
Satellite Frequency Conversion . . . . 3-29
STDMA Statistics . . . . . . . . . . . 3-30
Stats Accumulation Window . . . . . 3-30
Clear . . . . . . . . . . . . . . . . . 3-31
Show Hub Statistics . . . . . . . . . . 3-31
STDMA/SCPC Automatic Switching. . . . 3-32
Auto Switching . . . . . . . . . . . . . 3-33
Current WAN Transmit Mode . . . . . 3-34
Load Switching . . . . . . . . . . . . 3-34
STDMA Slot Capacity . . . . . . . . . 3-34
STDMA Switch Delay . . . . . . . . . 3-35
Percent Allocation . . . . . . . . . . . 3-35
Keep Alive Timer for Carrier Inhibit . . 3-36
Hitless Switching Parameters . . . . . 3-36
Delay for Mod . . . . . . . . . . . . 3-37
Delay for Demod. . . . . . . . . . . 3-37
LockTimes . . . . . . . . . . . . . . 3-37
Apply Delay Values . . . . . . . . . 3-38
SOTM Update . . . . . . . . . . . . . 3-38
Unit Role. . . . . . . . . . . . . . . . . . 3-38
Expansion Unit . . . . . . . . . . . . . . 3-39
Network ID. . . . . . . . . . . . . . . . . 3-39
Unit Name . . . . . . . . . . . . . . . . . 3-40
Receive Multicast Address . . . . . . . . 3-40
Managing IP Address . . . . . . . . . . . 3-41
Management Security . . . . . . . . . . . 3-42
Primary Heart Beat . . . . . . . . . . . . 3-44
Home State Revert . . . . . . . . . . . . 3-44
Dynamic Power Control Configuration . . 3-44
DPC Enabled . . . . . . . . . . . . . 3-46
Speed Up EbNo . . . . . . . . . . . . 3-46
Target DPC Address . . . . . . . . . 3-46
Set Home State Parameters . . . . . . . 3-47
Set Current Configuration as Home State. .
3-48
Force Modem to Home State . . . . . 3-48
STDMA State . . . . . . . . . . . . . 3-49
Receive Frequency . . . . . . . . . . 3-49
Receive Data Rate . . . . . . . . . . 3-49
Receive FEC Type . . . . . . . . . . 3-50
Receive Coding Rate . . . . . . . . . 3-50
Receive Modulation Type . . . . . . . 3-51
Vipersat Summary . . . . . . . . . . . . 3-51
Vipersat Migration. . . . . . . . . . . . . 3-52
UDP Port Base Address . . . . . . . . . 3-53
Alerts . . . . . . . . . . . . . . . . . . . 3-53
Appendix A
Network Addressing
Introduction . . . . . . . . . . . . . . . . . . A-1
The OSI Reference Model . . . . . . . . . . A-2
Layers 1 – 3 . . . . . . . . . . . . . . . . . A-2
Binary Math . . . . . . . . . . . . . . . . . . A-4
IP Addressing . . . . . . . . . . . . . . . . . A-6
IP Address Classes . . . . . . . . . . . . . A-6
Class A . . . . . . . . . . . . . . . . A-6
Class B . . . . . . . . . . . . . . . . A-6
Class C . . . . . . . . . . . . . . . . A-7
Class D . . . . . . . . . . . . . . . . A-7
Class E . . . . . . . . . . . . . . . . A-8
Private Network IP Addresses . . . . . A-8
Network Address Translation (NAT). . . A-8
Subnets . . . . . . . . . . . . . . . . . . . A-8
Subnet Mask . . . . . . . . . . . . . . . . A-9
Network Segments . . . . . . . . . . . . A-10
Default Gateways . . . . . . . . . . . . . A-11
MAC Addresses. . . . . . . . . . . . . . A-11
Appendix B
Automatic Switching
General . . . . . . . . . . . . . . . . . . . . B-1
Hitless Switching . . . . . . . . . . . . . . B-2
Load Switching . . . . . . . . . . . . . . . . B-4
Overview . . . . . . . . . . . . . . . . . . B-4
Table of Contents iii
MN/22137, rev 1
Bandwidth Allocation and Load Switching by
the Hub STDMA Burst Controller . . .B-5
Load Switching—STDMA Hub . . . . . . .B-8
Hub Switching Parameters . . . . . . .B-8
Hub Switching Process . . . . . . . . .B-9
Load Switching—Remote . . . . . . . . . B-10
Remote Switching Parameters . . . . B-10
Determination for Switching . . . . . . B-12
Load Switch Example . . . . . . . . . . . B-13
Reduced Data Flow in Switched Mode
(SCPC) . . . . . . . . . . . . . . . B-14
Application Switching . . . . . . . . . . . . . B-16
ToS Switching . . . . . . . . . . . . . . . . . B-18
ToS Background . . . . . . . . . . . . . . B-18
Detection of ToS Stamped Packets . . B-19
Configuration . . . . . . . . . . . . . B-20
Example Implementations . . . . . . . . . B-21
ToS Switching Per Device . . . . . . . B-21
ToS Switching Per Traffic Type . . . . B-21
ToS Remarking . . . . . . . . . . . . B-22
ToS to DSCP Value Conversions . . . B-23 Mesh Setup Based on ToS Detection . B-24
Entry Channel Mode Switching . . . . . . . . B-25
STDMA Entry Channel Mode . . . . . . . B-25
Fail-Safe Operation . . . . . . . . . . B-26
Using STDMA ECM . . . . . . . . . . B-28
Switching an ECM Remote from SCPC to
STDMA. . . . . . . . . . . . . . . B-29
Dynamic Entry Channel Mode. . . . . . . B-31
Hub Configuration . . . . . . . . . . . B-32
Remote Configuration . . . . . . . . . B-33
ECM Processing. . . . . . . . . . . . B-34
Appendix C
Dynamic Power Control
Introduction . . . . . . . . . . . . . . . . . . C-1
Description . . . . . . . . . . . . . . . . . . C-3
BER Waterfall Mapping . . . . . . . . .C-3
Delta Power Compensation . . . . . . .C-3
Theory of Operation . . . . . . . . . . . . .C-4
Configuration . . . . . . . . . . . . . . . . . C-7
Main DPC Menu . . . . . . . . . . . . . . .C-9
Enable DPC . . . . . . . . . . . . . C-10
Target Eb/No . . . . . . . . . . . . C-10
Speed Up Eb/No Range . . . . . . . C-11
Target DPC (IP) Address . . . . . . C-11
Calculate Max Power Menu . . . . . . . . C-11
Calibrated Data Rate . . . . . . . . C-13
DPC Margin . . . . . . . . . . . . . C-13
Nominal Power Level . . . . . . . . C-13
Max Data Rate . . . . . . . . . . . C-13
Max Code Rate . . . . . . . . . . . C-13
Max Modulation . . . . . . . . . . . C-13
Max FEC Type . . . . . . . . . . . C-13
Calculate Max Power . . . . . . . . C-13
Max Power . . . . . . . . . . . . . C-14
Signal Power Level Considerations . . . . . . C-15
Power Considerations. . . . . . . . . . . C-16
Cabling Considerations . . . . . . . . . . C-16
Appendix D
ECM Migration
General . . . . . . . . . . . . . . . . . . . . D-1
Migration Procedure . . . . . . . . . . . . . D-3
Configure Remote Units. . . . . . . . . . . D-3
Configure Hub Unit . . . . . . . . . . . . . D-5
Appendix E
Glossary
. . . . . . . . . . . . . . . . . . . . . . . . . E-1
iv Vipersat CDD-56X Series User Guide
MN/22137, rev 1
{ This Page is Intentionally Blank }
List of Figures v
Chapter 2 Figures
Figure 2-1 Main Menu screen. . . . . . . . . . . . . . 2-4
Figure 2-2 Administration screen . . . . . . . . . . . 2-4
Figure 2-3 Feature Configuration screen . . . . . 2-5
Figure 2-4 FAST Feature Code dialog . . . . . . . 2-5
Figure 2-5 Working Mode dialog . . . . . . . . . . . 2-6
Figure 2-6 Ethernet Interface screen . . . . . . . . 2-7
Figure 2-7 Configuring the Route Table screen 2-9
Figure 2-8 Rx Configuration screen . . . . . . . . 2-10
Figure 2-9 Vipersat Configuration screen (Hub). .
2-10
Chapter 3 Figures
Figure 3-1 Main Menu screen. . . . . . . . . . . . . . 3-3
Figure 3-2 Administration screen . . . . . . . . . . . 3-4
Figure 3-3 Working Mode dialog . . . . . . . . . . . 3-4
Figure 3-4 Feature Configuration screen . . . . . 3-5
Figure 3-5 FAST Feature Code dialog . . . . . . . 3-6
Figure 3-6 Vipersat Configuration screen (Hub)3-8 Figure 3-7 STDMA screen (Hub, STDMA, Fixed
type). . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
Figure 3-8 STDMA screen (Hub/Remote, SCPC)
3-9
Figure 3-9 Hub Type prompt . . . . . . . . . . . . . 3-10
Figure 3-10 ECMv2 Mode prompt . . . . . . . . . 3-13
Figure 3-11 Group ID prompt . . . . . . . . . . . . . 3-14
Figure 3-12 STDMA Max Power Hunt prompt 3-15 Figure 3-13 Burstmap Multicast IP prompt . . . 3-16
Figure 3-14 Outbound IP prompt . . . . . . . . . . 3-16
Figure 3-15 Cycles per Burst Map prompt . . . 3-17
Figure 3-16 Slot Guardband prompt. . . . . . . . 3-17
Figure 3-17 Slot Preamble Length prompt . . . 3-18
Figure 3-18 Slot Data Length prompt . . . . . . . 3-19
Figure 3-19 Nominal Data Length prompt . . . 3-19 Figure 3-20 Maximum Data Length prompt . . 3-20 Figure 3-21 Minimum Data Length prompt. . . 3-20
Figure 3-22 Total Slot Count prompt . . . . . . . 3-21
Figure 3-23 STDMA Remotes Menu screen . 3-22 Figure 3-24 Remote Name and IP Address prompt
3-22 Figure 3-25 Base Remote Display prompt . . . 3-23 Figure 3-26 STDMA Remote Policies screen (GIR
Hub) . . . . . . . . . . . . . . . . . . . . . . . . . . .3-24
Figure 3-27 GIR Remote Policies prompt . . . . 3-25
Figure 3-28 Entry Channel Switch Rates screen .
3-25 Figure 3-29 Remote SCPC Data Rate prompt3-26 Figure 3-30 Global SCPC Data Rate prompt .3-26
Figure 3-31 Global Switch Type prompt . . . . .3-26
Figure 3-32 Delete Remote prompt . . . . . . . .3-27
Figure 3-33 Enable/Disable Remote prompt .3-27
Figure 3-34 View Remote(s) screen . . . . . . . .3-27
Figure 3-35 Remove Timeout prompt . . . . . . . 3-28
Figure 3-36 Remove Retry Timeout prompt . .3-28
Figure 3-37 LNB LO Frequency prompt . . . . .3-29
Figure 3-38 Satellite Frequency Conversion prompt
3-29 Figure 3-39 STDMA Statistics screen (Hub). .3-30 Figure 3-40 STDMA Statistics screen (Remote). .
3-30 Figure 3-41 Stats Accumulation Window prompt .
3-31
Figure 3-42 Show Hub Statistics screen. . . . . 3-31
Figure 3-43 Automatic Switching screen . . . .3-33
Figure 3-44 STDMA Slot Capacity prompt . . .3-34 Figure 3-45 STDMA Switch Delay prompt . . . 3-35
Figure 3-46 Percent Allocation prompt . . . . . .3-35
Figure 3-47 Keep Alive Timer for Carrier Inhibit
prompt . . . . . . . . . . . . . . . . . . . . . . . . .3-36
Figure 3-48 Hitless Switching screen . . . . . . .3-37
Figure 3-49 Set LockTime prompt . . . . . . . . .3-38
Figure 3-50 Unit Role prompt . . . . . . . . . . . . . 3-38
Figure 3-51 Expansion Unit prompt . . . . . . . .3-39
Figure 3-52 Network ID prompt . . . . . . . . . . .3-40
Figure 3-53 Unit Name prompt . . . . . . . . . . . .3-40
Figure 3-54 Receive Multicast IP Address prompt
3-41 Figure 3-55 Managing IP Address prompt . . . 3-41 Figure 3-56 Vipersat Management Security screen
3-43
Figure 3-57 Encryption Key Entry prompt. . . . 3-43
Figure 3-58 DPC Configuration screen (Hub,
STDMA) . . . . . . . . . . . . . . . . . . . . . . . .3-45
Figure 3-59 DPC Configuration screen (Hub/
Remote, SCPC) . . . . . . . . . . . . . . . . . .3-45
Figure 3-60 Speed Up EbNo prompt . . . . . . .3-46
Figure 3-61 Target DPC Address prompt . . . .3-47
List of Figures
vi Vipersat CDD-56X Series User Guide
MN/22137, rev 1
Figure 3-62 Home State Configuration screen3-48 Figure 3-63 Force Modem to Home State warning
3-49
Figure 3-64 Receive Frequency prompt . . . . . 3-49
Figure 3-65 Receive Data Rate prompt . . . . . 3-50
Figure 3-66 Receive FEC Type prompt . . . . . 3-50
Figure 3-67 Receive Coding Rate prompt . . . 3-50 Figure 3-68 Receive Modulation Type prompt 3-51
Figure 3-69 Vipersat Summary screen. . . . . . 3-51
Figure 3-70 Vipersat Migration prompt . . . . . . 3-53
Figure 3-71 UDP Port Base Address prompt . 3-53
Appendix A Figures
Figure A-1 The Seven OSI Protocol Layers . . .A-2
Figure A-2 Bits and Bytes. . . . . . . . . . . . . . . . .A-4
Figure A-3 Binary to Decimal Conversion . . . .A-4
Figure A-4 IP Address Classes A, B, C . . . . . .A-7
Figure A-5 NAT Router Example . . . . . . . . . . .A-8
Figure A-6 Default Subnet Masks for IP Classes .
A-9 Figure A-7 ANDing an IP address and a subnet
mask . . . . . . . . . . . . . . . . . . . . . . . . . .A-10
Figure A-8 Network Segments . . . . . . . . . . . .A-10
Figure A-9 Router as Default Gateway. . . . . .A-11
Figure A-10 Network Node MAC Addresses .A-12
Appendix B Figures
Figure B-1 Hitless Switching screen. . . . . . . . .B-2
Figure B-2 Auto Switching Menu, CDM-570/570L
Hub . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-8
Figure B-3 Hub Load Switching Page, SLM-5650A
B-8 Figure B-4 Auto Switching Menu, CDM-570/570L
Remote . . . . . . . . . . . . . . . . . . . . . . . .B-11
Figure B-5 Remote Load Switching Page, SLM-
5650A . . . . . . . . . . . . . . . . . . . . . . . . . B-11
Figure B-6 Load Switching diagram . . . . . . . .B-13
Figure B-7 Application Switching diagram . . .B-16 Figure B-8 ToS Field Location within the IP Header
B-18
Figure B-9 Remote ToS Switching menu . . . .B-20
Figure B-10 Per Device ToS Switching Example .
B-21
Figure B-11 Per Type ToS Switching Example . .
B-22 Figure B-12 ToS Remarking Application . . . B-23 Figure B-13 ToS and DSCP Conversion Chart . .
B-23 Figure B-14 ECM Switch Recovery: < 3 minutes .
B-27 Figure B-15 ECM Switch Recovery: > 3 minutes .
B-28 Figure B-16 STDMA Page with Entry Channel
Mode, CDM-570/570L . . . . . . . . . . . . B-29
Figure B-17 ECM Remote List Page, CDM-570/
570L . . . . . . . . . . . . . . . . . . . . . . . . . . B-30
Figure B-18 Remote Bandwidth Entry, CDM-570/
570L . . . . . . . . . . . . . . . . . . . . . . . . . . B-30
Figure B-19 Revert Uplink Carrier Command, VMS
modem . . . . . . . . . . . . . . . . . . . . . . . . B-31
Figure B-20 Entry Channel Mode v2 Configuration,
Hub (CDD-564L) . . . . . . . . . . . . . . . . B-33
Figure B-21 Entry Channel Mode v2 Configuration,
Remote (CDM-570L) . . . . . . . . . . . . . B-34
Figure B-22 ECMv2 Processing Diagram. . . B-35
Appendix C Figures
Figure C-1 Data Rate to Power Relationship, DPC
C-5 Figure C-2 Excessive Max Power Example . . C-6 Figure C-3 DPC Configuration screen, CLI . . C-9 Figure C-4 DPC dialog, Parameter Editor . . C-10 Figure C-5 DPC Calculate Max Power screen, CLI
C-12 Figure C-6 DPC Calibration dialog, Parameter
Editor . . . . . . . . . . . . . . . . . . . . . . . . . C-12
Figure C-7 Signal Power Levels, Remote SiteC-15
Appendix D Figures
Figure D-1 STDMA Configuration Page, Remote
CDM-570/L. . . . . . . . . . . . . . . . . . . . . . D-4
Figure D-2 STDMA Configuration Menu, Hub Type
Selection . . . . . . . . . . . . . . . . . . . . . . . D-5
Figure D-3 STDMA Menu, ECMv2 Hub Type . D-6 Figure D-4 Switch Rate Limits, InBand Return Path
Settings Page. . . . . . . . . . . . . . . . . . . . D-7
List of Tables vii
Chapter 2 Tables
Table 2-1 CDD-56X Network Roles and Functions
2-3
Table 2-2 Vipersat Feature Configuration . . . . 2-6
Appendix B Tables
Table B-1 STDMA ACK Message . . . . . . . . . .B-6
Table B-2 ToS Switching Settings . . . . . . . . .B-20
Appendix C Tables
Table C-1 DPC Parameters, Main Menu . . . . .C-7
Table C-2 DPC Parameters, Calculate Max Power
Menu . . . . . . . . . . . . . . . . . . . . . . . . . . .C-8
Table C-3 Typical Coaxial Cable Characteristics .
C-17
List of Tables
viii Vipersat CDD-56X Series User Guide
MN/22137, rev 1
{ This Page is Intentionally Blank }
Chapter 1 - General 1-1
C
HAPTER
GENERAL
How to Use This Manual
This manual documents the enhanced Vipersat features and functions of the CDD-56X Series (CDD-562L, CDD-564, and CDD-564L) of Satellite Network Demodulator Routers, and guides the user in how to configure these products for use in a Vipersat network. The material covered addresses only those areas specific to a CDD-56X running in Vipersat mode, and complements the univer­sal features and functions described in the CDD-564L Installation and Opera- tion Manual.
Earth station engineers, technicians, and operators responsible for the configu­ration and maintenance of the CDD-56X are the intended audience for this document.
Manual Organization
This User’s Guide is organized into the following sections:
Chapter 1 General
Contains CDD-56X product description, customer support information, and manual conventions and references.
Chapter 2 Quick Start Configuration
Covers the initial basic steps that are necessary for configuring the CDD-56X from a factory default state to a functional network element.
Ho w t o Us e T h i s Ma nu a l MN/22137, rev 1
1-2 Vipersat CDD-56X Series User Guide
Chapter 3 Using the Command Line Interface (CLI)
Describes the use of the CLI for configuring and monitoring the CDD-56X in a Vipersat network. Each CLI screen is presented along with a detailed descrip­tion and related commands.
Appendix A Network Addressing
Supplemental reference information on binary math and network addressing to assist with integrating the CDD-56X into a Vipersat network.
Appendix B Automatic Switching
Supplemental reference information on the Vipersat feature that provides load switching (response to network traffic load), application switching (response to traffic type) functions, and Entry Channel Mode switching functions.
Appendix C Dynamic Power Control
A description of Vipersat’s DPC feature and its functionality in a network of CDM-570/CDD-56X series equipment.
Appendix D ECM Migration
Procedural instructions on migrating a Vipersat network of CDM-570/CDD­56X series equipment from STDMA Entry Channel Mode (ECMv1) to Dynamic Entry Channel Mode (ECMv2).
Appendix E — Glossary
A glossary of terms that pertain to Vipersat satellite network technology.
Conventions and References
The following conventions are utilized in this manual to assist the reader:
Note: Provides important information relevant to the accompanying
text.
Tip: Provides complementary information that facilitates the
associated actions or instructions.
NOTE
Chapter 1 - General 1-3
MN/22137, rev 1 Ho w t o Us e T hi s Ma nu a l
Caution: Explanatory text that notifies the reader of possible
consequences of an action.
Warning: Explanatory text that notifies the reader of potential harm
as the result of an action.
The following documents are referenced in this manual, and provide supple­mentary information for the reader:
CDD-564L L-Band Quad Demodulator with IP Module Installation and
Operation Manual (Part Number MN/CDD564L.IOM)
CDM-570/570L Modem Installation and Operation Manual (Part Number
MN/CDM570L.IOM)
Vipersat CDM-570/570L User Guide (Part Number MN/22125)
Vipersat CDM-570/L, CDD-56X Parameter Editor User Guide (Part
Number MN-0000038)
Vipersat Management System User Guide (Part Number MN/22156)
VLoad Utility User Guide (Part Number MN/22117)
Product Description MN/22137, rev 1
1-4 Vipersat CDD-56X Series User Guide
Product Description
Introduction
The Vipersat CDD-56X Satellite Network Demodulator Router is ideal for operators wishing to supply mesh connectivity between sites, while keeping network infrastructure costs down. The CDD-564 and CDD-564L provide four separate demodulators (the CDD-562L provides two) and an integrated router in a compact, cost-effective 1RU package.
The CDD-56X simplifies Hub site installations by reducing rack space and cost with 2/4 independent demodulators in a single chassis. A bank of CDD-56X demodulators is ideal for a star network consisting of a single outbound carrier at the Hub with multiple carriers returned from the remote sites.
The CDD-56X can be used at Hub sites where multiple burst controllers are needed. Demodulator roles are defined via software, configurable either as a burst controller in STDMA (Selective Time Division Multiple Access) mode, or as dedicated SCPC (Single Channel per Carrier) inbounds from remote termi­nals.
At Remote sites, the CDD-56X supports mesh connectivity between multiple sites. Operating in mesh topology with links directly between sites eliminates double-hops through the Hub, conserving bandwidth and reducing latency.
Demodulator Features
50–90 MHz or 100–180 MHz IF Range, each Demodulator (CDD-564)
950–1950 MHz IF Range, each Demodulator (CDD-562L/564L)
QPSK, 8-PSK, and 16-QAM Operation
Data Rate Range from 16 kbps up to 9.98 Mbps, depending on modulation
and FEC used (with FAST feature upgrade)
Turbo Product Coding (TPC) FEC
Fast Acquisition Demodulator
Simultaneous STDMA (burst) and dSCPC modes (configurable on a per
demodulator basis)
LNB Support: 10 MHz Reference and LNB Power
N:M Hub Modem Redundancy Schemes
Router Features
Fully Integrated Network Management using Vipersat Management
System (VMS)
Chapter 1 - General 1-5
MN/22137, rev 1 Product Description
Single Hop On Demand (SHOD) functions
10/100BaseT Ethernet LAN/WAN Interface
Static IP Routing for Unicast or Multicast
Header Decompression
Payload Decompression
3xDES Decryption
Network and Bandwidth Management
A Vipersat-powered network solution integrates this advanced demodulator/ router with the powerful network management tool, the Vipersat Management System (VMS). The VMS provides for traditional monitor and control of the CDM-570/570L modems and the CDD-56X demodulators, but more than just an M&C package, the VMS offers unique bandwidth management that is ideal for IP-switched networks. Short data transfers are typically executed using a shared Selective Time Division Multiple Access (STDMA) channel, and when large amounts of data transfer, voice, and/or video communications are needed, these units can be automatically switched to a dedicated SCPC channel.
Dynamic SCPC (dSCPC)
The VMS provides for dynamic bandwidth allocation while in SCPC mode, automatically altering the bandwidth based on traffic conditions. This effec­tively enables the network to better handle connection-oriented applications and reduce network congestion, jitter, and latency.
In a typical Vipersat application used in conjunction with CDM-570/570L modems, the CDD-56X demodulators are drawn from a pool for assignment to a connection-oriented link.
Traffic inbounds from remotes can be switched manually or automatically, application or load triggered, or scheduled, from shared STDMA (burst) mode to a dedicated SCPC connection. The VMS automatically assigns a free demod­ulator at the Hub to a desired remote inbound, completely eliminating manual intervention. At remote sites, the CDD-56X simplifies Single Hop On Demand (SHOD) applications with direct remote-to-remote connections that do away with double-hops. Once the session is completed, the remote is automatically reverted back to its home state.
The result is an economical and flexible network with bandwidth shared and directed where it is needed for any mix of IP voice, video, and data traffic.
Product Description MN/22137, rev 1
1-6 Vipersat CDD-56X Series User Guide
STDMA
The addition of STDMA capability to a Vipersat network allows multiple termi­nals to share the same satellite resources that would be dedicated to a single terminal in an SCPC configuration. This means that more terminals can be added to the network with minimal additional cost in either satellite bandwidth or Hub Terminal hardware.
Vipersat STDMA thus provides a low cost solution for medium to large sized networks with generally moderate bandwidth requirements, while at the same time providing all the features of the existing Vipersat systems, including the availability of a switched pool of SCPC channels for occasional high bandwidth traffic such as video conferences and large file transfers. Each STDMA upstream channel from the remote terminals to the Hub uses an STDMA frame operating at an aggregate data rate of from 16 kbps to 9.98 Mbps and can support up to hundreds of remote terminals with multiple burst channel inbounds.
Configured as a Hub terminal, the CDD-564/564L provides one demod for receiving an upstream STDMA channel from the remotes, and three demods for receiving three SCPC channels.
Single Hop On Demand
The CDD-56X is ideal for mesh applications such as Vipersat's Single Hop On Demand (SHOD). With the CDD-56X, SHOD (meshed) circuits are easily and economically established between remotes. SHOD provides significant and dynamic connectivity between latency connections without suffering the high costs associated with multiple carriers and/or 1-to-1 multi-receiver links.
Turbo Product Coding
The Comtech Vipersat CDD-56X incorporates a Turbo Product Codec (TPC) error correction, delivering significant performance improvement when compared to Viterbi with concatenated Reed-Solomon. TPC simultaneously offers increased coding gain, lower decoding delay, and significant bandwidth savings.
Header Decompression
Header compression reduces the required Voice over Internet Protocol (VoIP) bandwidth by as much as 60%. Example: a G.729 voice codec operating at 8 kbps will occupy 32 kbps once encapsulated into IP framing on a LAN. Using IP/UDP/RTP Header Compression, the same traffic only needs 10.8 kbps total WAN satellite bandwidth to cross the link. The CDD-56X demods perform header decompression prior to passing the data onto the LAN.
Chapter 1 - General 1-7
MN/22137, rev 1 Product Description
Payload Decompression
Payload compression condenses the size of data frames and reduces the satellite bandwidth required to transmit across the link. Configurable on a per route basis, Payload Compression provides traffic optimization and reduces band­width up to 40%. The CDD-56X demods perform payload decompression prior to passing the data onto the LAN.
Data Decryption
The CDD-56X decrypts 3xDES data that it receives. Data encryption, configu­rable on a per route basis, is used to prevent unauthorized access to data over the satellite link.
New in This Release
The following firmware version incorporates a number of additional features and enhancements.
1.6.11/2.6.11 Release
Dynamic Entry Channel Mode
Dynamic ECM (ECMv2) utilizes a modified slotted Aloha method for Remotes to establish registration in the network and obtain the means for switching into dSCPC mode. Rather than sharing an STDMA burst map, as is the method with STDMA ECM, the Remotes rely on communicating with the Hub channel controller through the use of a multicast Transmission Announcement Protocol (TAP) message. This eliminates the restriction in the number of Remotes in an Entry Channel group that is inherent with the burst map method.
Customer Support MN/22137, rev 1
1-8 Vipersat CDD-56X Series User Guide
Customer Support
Contact Information
Contact Comtech Vipersat Networks Customer Support for information or assistance with product support, service, or training on any Vipersat product.
Mail: 3215 Skyway Court
Fremont, CA 94539 USA
Phone: 1+510-252-1462 ext. 2
Fax: 1+510-252-1695
Email: supportcvni@comtechefdata.com
Web: www.comtechefdata.com
Return Material Authorization
Any equipment returned to Vipersat must have a Return Material Authorization (RMA) issued prior to return. To return a Comtech Vipersat Networks product for repair or replacement:
Obtain an RMA form and number from Vipersat Customer Support.
Be prepared to supply the product model number and serial number of the
unit.
To ensure safe shipping of the product, pack the equipment in the original
shipping carton.
Reader Comments / Corrections
If the reader would like to submit any comments or corrections regarding this manual and its contents, please forward them to a Vipersat Customer Support representative. All input is appreciated.
Chapter 2 - Quick Start Configuration 2-1
C
HAPTER
QUICK START CONFIGURATION
Introduction
This chapter describes the minimum configuration of a Vipersat CDD-56X Series Demodulator Router that is necessary in order for the equipment to func­tion in a Vipersat network.
The Vipersat CDD-56X Demodulator Router stores its configuration in an ASCII file named the PARAM file. Equipment Configuration is typically performed through the use of the Command Line Interface (CLI), particularly the initial configuration. Once the equipment is functioning in the network, additional configuration can be performed via the VMS.
Refer to Chapter 3, “Using the Command Line Interface (CLI)”, for a detailed description on the usage of this feature.
This manual covers the configuration specifics of the CDD-56X when used in a Vipersat network. Refer to the CDD-564L L-band Quad Demodulator Installa- tion and Operation Manual for general instruction on setting up, installing and configuring this equipment.
Note: Before attempting to configure a CDD-56X to be used in a Vipersat
network, make certain it has the Vipersat option installed and enabled.
NOTE
Initial Configuration MN/22137, rev 1
2-2 Vipersat CDD-56X Series User Guide
Initial Configuration
Note: Many of the settings required for equipment configuration are based on
the LAN/WAN and Satellite network design, and should be obtained from the network administrator.
Terminal Connection
These procedures are performed using the CLI from a workstation connected to the CDD-56X either via a direct connection to the Console port (a console cable is shipped with each unit), or via a telnet connection to the Traffic 100 port. Alternatively, HyperTerminal or any of the other connection methods described in the CDD-564L L-band Quad Demodulator Installation and Operation Manual may be used.
Make a terminal connection to the target CDD-56X demodulator/router. If connecting via the Traffic 100 Ethernet port (do not use the M&C port), enter the IP address of the unit. The factory default IP address for a Vipersat enabled unit is 192.168.254.2. Configure the terminal for VT-100 emulation mode. Once a terminal connection has been made, the CDD-56X will respond with a Login prompt. The factory defaults for accessing the Admin level are:
Login: comtech Password: comtech
Once the operator has logged in, the Main Menu shown in figure 2-1 is displayed.
Network Role
The first and most important step prior to configuring the CDD-56X is to define its network role.
The CDD-56X is a flexible network component able to perform different func­tions depending on how it is used in a network. The role that is defined for each CDD-56X will determine what functions are available for each unit to fill its role. Table 2-1 lists the network roles and the corresponding network functions for which the CDD-56X can be configured.
NOTE
Chapter 2 - Quick Start Configuration 2-3
MN/22137, rev 1 Initial Configuration
The procedure for setting the modem configuration to match the defined network role is presented later in this Quick Start (“Set the Vipersat Configura­tion” on page 2-10).
Refer to the section “Unit Role” on page 3-38, and the following section “Expansion Unit”, for additional details on setting a CDD-56X’s network role.
Setting Vipersat CDD-56X Operating Parameters
The following is an example of using the CLI to bring a Vipersat CDD-56X with factory default settings to the configuration which allows the Vipersat functions to be accessible.
Set the Feature Configuration
The operating parameters that will be configured in the target CDD-56X are, in part, determined by the role the CDD-56X is to fill in the network, as shown in table 2-1 and table 2-2.
Use the following procedure to configure a CDD-56X to the network role it is to fill in a Vipersat network.
1. From the Main Menu shown in figure 2-1, select the Administration
command by entering A at the command prompt.
Table 2-1
CDD-56X Network Roles and Functions
Demod
Role / Location Expansion 1 2 3 4
Hub No STDMA SCPC SCPC SCPC
Hub Yes SCPC SCPC SCPC SCPC
Remote Yes SCPC SCPC SCPC SCPC
Initial Configuration MN/22137, rev 1
2-4 Vipersat CDD-56X Series User Guide
Figure 2-1
Main Menu screen
2. From the Administration screen shown in figure 2-2, select the Features Configuration command by entering F at the command prompt.
Figure 2-2
Administration screen
3. From the Feature Configuration menu shown in figure 2-3, verify whether or not the Vipersat Feature Codes are Available (appears as shown in the figure). These codes are entered prior to shipment from the factory; however, if the codes display as Unavailable, they will have to be re-entered.
Chapter 2 - Quick Start Configuration 2-5
MN/22137, rev 1 Initial Configuration
Figure 2-3
Feature Configuration screen
To enter the feature code, enter Y at the command prompt, then enter the 20 digit FAST Feature Code, as shown in figure 2-4.
Figure 2-4
FAST Feature Code dialog
Tip: The network administrator will have the FAST Feature codes. These are
generated and stored by the unit serial number for the target CDD-56X. The target unit’s serial number can be found on the rear of the unit chassis.
4. After entering the FAST Feature code, return to the Administration screen, shown in figure 2-2, and ensure that the Working Mode is set to Router- Vipersat.
If it is not, enter C and change the setting by selecting 4, as shown in figure 2-5. The unit will reboot automatically in order to implement the change for this setting.
Initial Configuration MN/22137, rev 1
2-6 Vipersat CDD-56X Series User Guide
Figure 2-5
Working Mode dialog
5. When the reboot is completed, return to the Feature Configuration menu and configure the settings for Vipersat STDMA and Auto Switching according to the table below.
6. Save the settings to flash by entering S at the command prompt.
Set the IP Address
1. From the Main Menu, enter I to access the Interface Configuration menu
screen, then enter E to access the Ethernet Interface screen (figure 2-6).
2. Enter I at the command prompt, and enter the IP address for this unit.
Table 2-2
Vipersat Feature Configuration
Unit Role Vipersat STDMA Auto Switching
Hub Enabled Enabled (optional) Enabled
Hub Expansion Enabled Disabled Disabled
Remote Expansion Enabled Disabled Disabled
Chapter 2 - Quick Start Configuration 2-7
MN/22137, rev 1 Initial Configuration
Figure 2-6
Ethernet Interface screen
3. Save the settings to flash by entering S at the command prompt.
Configure the Route Table
Routing in a Vipersat Network
CDD-56X Demodulator Routers operating in Vipersat mode do not use the small or large network described in the CDD-564L Installation and Operation Manual. There is no HDLC address in a Vipersat network; instead, the CDD-56X role designation — Hub or Remote, Expansion unit or not — deter­mines routing rules that prevent multicast loops. This simplifies the configura­tion of a Vipersat network.
Because satellite networks are often used as extensions for access to services such as the Internet or the PSTN, they lend themselves quite readily to private addressing. For example, to provide Internet access to the satellite network, only the Hub requires a public IP address in order for the entire satellite network that is controlled by the Hub to have access to the Internet backbone. Utilizing Network Address Translation (NAT), the administrator can effectively address the network using a minimum number of static route statements.
Example:
The IP address 172.16.0.0 is the private address network number for class B networks. If there is a router at the Hub with a connection to the Internet, the operator can define the local network as a class B. If the operator splits the Class B in half and points the upper half toward the satellite there will be over 16000 usable addresses at the Hub as well as at the Remotes. For details on IP address­ing, refer to Appendix A, "Network Addressing".
Initial Configuration MN/22137, rev 1
2-8 Vipersat CDD-56X Series User Guide
By putting the one route statement “Remotes 172.16.128.0/17 Wan to Sat” in the TDM Hub modem, and by using the route statement “GW 0.0.0.0/0 Wan to Sat” at each of the remote modems, the network will successfully route packets. The remotes can then be sub-netted as class C networks or below. Additional routers at the remotes can be added for unusually large sites, allowing an addi­tional layer of NAT without requiring any more explicit routing within the Vipersat Modem/Routers.
Refer to the CDD-564L Installation and Operation Manual for additional infor­mation on entering routes.
Creating the Routes
The following procedure outlines the basic route structure that the target CDD-56X will require for its role in the network. One of the key routes that must be created is a gateway address for routing the data traffic that is received by the unit.
1. From the Main Menu shown in figure 2-1, select Route Table by entering
R at the command prompt.
2. From the Configuring the Route Table screen shown in figure 2-7, enter 1 at the command prompt to set the first route that will define the default
gateway.
In a Hub configuration, the default gateway will typically point to a router on the same LAN as the CDD-56X Hub unit.
In a Remote configuration, the default route will typically point to the satellite modem used for communications back to the Hub.
3. When prompted, enter the Route Name (GW), the IP Address, the Number of Bits in the subnet mask, the Route Interface (Ethernet or Sat-
ellite), and the Next Hop address. The system administrator can supply this information, if necessary.
In a Hub role, for example, enter the name of the route (e.g., GW), enter
0.0.0.0 for the destination IP address and 0 for the mask, enter E for Ethernet interface, then enter the IP address of the appropriate router or modem for the next hop.
Chapter 2 - Quick Start Configuration 2-9
MN/22137, rev 1 Initial Configuration
Figure 2-7
Configuring the Route Table screen
4. Enter S at the command prompt in figure 2-7 to save the settings to flash.
Set the Satellite Demod Configuration
1. Enter M from the Main Menu, then enter C from the Satellite
Demodulator menu to access the Configuration screen.
2. Enter R to access the Rx Configuration screen shown in figure 2-8. Set the Rx parameters for Frequency, Data Rate, FEC, Code Rate, and Modulation as specified by the network administrator.
The Receive parameters must be set for each Demod. Enter Z at the com­mand prompt to select the desired Demod, then set the Receive parameters for that Demod. Repeat for each Demod.
Note: Only Turbo Product Coding is acceptable for FEC when the CDD-56X is
running in Vipersat mode.
NOTE
Initial Configuration MN/22137, rev 1
2-10 Vipersat CDD-56X Series User Guide
Figure 2-8
Rx Configuration screen
3. Save the settings to flash by entering S at the command prompt.
Set the Vipersat Configuration
1. Enter V at the Main Menu command prompt (figure 2-1) to select the
Vipersat Configuration menu shown in figure 2-9.
Figure 2-9
Vipersat Configuration screen (Hub)
Chapter 2 - Quick Start Configuration 2-11
MN/22137, rev 1 Initial Configuration
2. Enter R at the command prompt to toggle the Unit Role to either Hub or Remote.
This parameter will determine the role the target CDD-56X will perform in the network and what type of commands and functions it will receive from the VMS.
3. Enter E to set the Expansion Unit value to either Yes or No. When configured as an Expansion unit, either as a Hub (switched) or as a Remote (mesh), the CDD-56X is set up so that all Demods are in SCPC mode and available as resources for dedicated communications with the other end of the satellite link.
4. Enter B at the command prompt to set the Network ID. The Network ID that is assigned to the unit defines to what network the target CDD-56X will belong. All units used in a network will have the same Network ID. This parameter is used by the VMS to identify units common to a network and allows the VMS to manage multiple networks, each with its own unique network ID number.
5. Enter N at the command prompt to set the Unit Name.
6. Enter V at the command prompt to set the Receive Multicast Address.
This IP address is the multicast address assigned to the VMS and to all units in the network that are managed by the VMS. The Receive Multicast Address of this CDD-56X must match the Transmit Multicast Address that has been assigned to the VMS.
7. Enter I at the command prompt to set the Managing IP Address. The Managing IP Address is the IP address of the VMS server.
8. Management Security (Optional) If this is an encrypted network, enter K at the command prompt to con­figure Vipersat Management Security.
9. Enter H to go to the Home State Configuration menu screen, then enter W to set the current configuration as the Home State.
10. Save the settings to flash by entering S at the command prompt.
This completes the initial configuration of a CDD-56X from the factory default settings to a functioning, Vipersat-enabled unit. Additional configuration parameters must be set depending on the network requirements for a specific application.
Initial Configuration MN/22137, rev 1
2-12 Vipersat CDD-56X Series User Guide
Refer to Chapter 3, “Using the Command Line Interface (CLI)”, for additional details on configuring the target Vipersat CDD-56X.
Chapter 3 - Using the Command Line Interface (CLI) 3-1
C
HAPTER
USING THE COMMAND LINE INTERFACE (CLI)
General
This chapter describes the use of the CLI for configuring and monitoring the CDD-56X Demodulator/Router in a Vipersat network. Each CLI screen related to a CDD-56X operating in Vipersat mode is presented, along with a detailed description of the available commands. For descriptions of all other screens, refer to the CDD-564L L-Band Quad Demodulator Installation and Operation Manual.
Access to the CLI is provided through either the Console port (local, RS-232) or the 10/100BaseT Ethernet Traffic port (Telnet, IP). Access via Telnet requires login with password, Console access does not require login. The screens presented in this document are as they appear when the CDD-56X is accessed using Telnet.
When a Telnet terminal connection is made, the CDD-56X responds with a Login prompt. The factory defaults are:
Login: comtech Password: comtech
Once the operator has logged in, the Main Menu shown in figure 3-1 is displayed.
Ge n era l MN/22137, rev 1
3-2 Vipersat CDD-56X Series User Guide
Common Screen Commands
The following commands appear on each of the menu screens:
Demod Select
Some feature configurations apply to the CDD-56X as a unit, others are set on a per Demod basis. This command (enter Z) allows the selection of one of the two (CDD-562L) or four (CDD-564/564L) Demodulators.
Save Parameters to Permanent Storage
To Save the current parameter settings to permanent storage, enter S at the command prompt. This command saves all data that has been entered from any of the CLI screens since the last save was executed. Exiting a screen without saving after parameters have been changed does not mean that the changes are not applied. However, if these changes are not saved prior to a system reset or power cycle, they will be lost.
Exit
To Exit the current menu screen and return to the previous screen in the menu tree, enter X at the command prompt.
Telnet Logout
Enter L at the command prompt to Logout of the Telnet session. This command appears only when connected via Telnet.
Chapter 3 - Using the Command Line Interface (CLI) 3-3
MN/22137, rev 1 Me nu D e s cr ip t io ns
Menu Descriptions
This section details the CLI menus and associated screens, and briefly discusses the function of each of the commands available on each menu.
Main Menu
The Main Menu, shown in figure 3-1, allows configuring both the Demodula­tor and Router functions of the target CDD-56X.
Note: The menu item Vipersat Configuration shown in figure 3-1 will only be
displayed if the target CDD-56X has had the Vipersat option enabled as described in the section “Setting Vipersat CDD-56X Operating Parame­ters” on page 2-3.
Figure 3-1
Main Menu screen
A Vipersat CDD-56X is normally shipped with the Vipersat option enabled. The CDD-56X configuration can be determined by whether or not the command line Vipersat Configuration is displayed on the menu, as shown in Figure 3-1.
Administration
The Administration menu provides access to the major Vipersat CDD-56X features and commands. Entering an A at the prompt in the Main Menu, shown in figure 3-1, displays the Administration screen shown in figure 3-2.
NOTE
Me n u De s crip ti o ns MN/22137, rev 1
3-4 Vipersat CDD-56X Series User Guide
Figure 3-2
Administration screen
Ensure that the Working Mode is set to Router-Vipersat. If it is not, enter C at the command prompt and change the setting by selecting 4, as shown in figure 3-3. The unit will reboot automatically in order to imple­ment the change for this setting.
Figure 3-3
Working Mode dialog
Note: If the Router-Vipersat option does not appear as a selection, the Vipersat
Feature Code has not yet been entered into this unit. Input the Vipersat code as described in the next section..
From the Administration menu, enter an F at the prompt to display the Feature Configuration screen shown in figure 3-4.
NOTE
Chapter 3 - Using the Command Line Interface (CLI) 3-5
MN/22137, rev 1 Me nu D e s cr ip t io ns
Feature Configuration
Figure 3-4
Feature Configuration screen
The Feature Configuration screen shown in figure 3-4 allows the Enabling and Disabling of the major Vipersat CDD-56X features.
Use this screen to enable and disable Vipersat features such as:
Vipersat STDMA — Burst mode operation
Vipersat Auto Switching — Allows switching to SCPC mode
Vipersat File Streamer — Rapid file transfers over satellite network
Note: These Vipersat features must be Enabled or Disabled using this menu.
They are not accessible from the Vipersat Configuration menu.
Vipersat Feature Codes
From the Feature Configuration menu, verify whether or not the Vipersat Feature Codes are Available (appears as shown in figure 3-4). These codes are entered prior to shipment from the factory; however, if the codes display as Unavailable, they will have to be re-entered. To enter the FAST Feature code, enter Y at the command prompt.
The Vipersat FAST Feature Codes can be entered as 20 hexidecimal digits at the command prompt as shown in figure 3-5.
NOTE
Me n u De s crip ti o ns MN/22137, rev 1
3-6 Vipersat CDD-56X Series User Guide
Figure 3-5
FAST Feature Code dialog
Tip: Contact either the network administrator or Comtech Vipersat Networks
Customer Support to obtain the Feature codes. A convenient option is to use the Vipersat Vload utility to manage Feature codes.
Vipersat Management
This item is an information-only display, and indicates whether Vipersat Management is Enabled or Disabled in the target CDD-56X. Activation of the
Vipersat Feature Code automatically enables the Vipersat Management feature.
Caution: This command must be Enabled in order to utilize any of the Vipersat
capabilities of the CDD-56X.
Vipersat STDMA
In order to utilize the Vipersat STDMA feature (burst mode) in the target Vipersat CDD-56X, this feature must be Enabled. Enter A at the command prompt to toggle On or Off.
Refer to table 2-2 for the relationship between Unit Role and STDMA. This feature should only be enabled for a unit that is used as a Hub with no expansion (i.e., a Burst Controller).
Note: Although the CDD-56X has multiple demods, STDMA is configurable for
only one demod. When this parameter is enabled, Demod 1 is set for STDMA mode and the remaining demods are set for SCPC mode.
Vipersat Auto Switching
The Vipersat Auto Switching feature allows the CDD-56X to automatically adjust to varying bandwidth demands in the Vipersat network by switching between STDMA and SCPC connections. This feature should only be enabled for a unit that is used as a Hub with no expansion, and that will be required to send switching requests to the VMS in response to either traffic type (Applica­tion switching) or network traffic loads (Load switching). Refer to table 2-2 for the relationship between Unit Role and Auto Switching.
NOTE
Chapter 3 - Using the Command Line Interface (CLI) 3-7
MN/22137, rev 1 Me nu D e s cr ip t io ns
To activate the Vipersat Auto Switching capabilities of the target CDD-56X, toggle the Auto Switching command to Enabled by entering W at the command prompt.
See the section “STDMA/SCPC Automatic Switching” on page 3-32 for more details on the use of this feature. For additional information, refer to Appendix B, “Automatic Switching”.
Vipersat File Streamer
Vipersat File Streamer (VFS) is an optional feature that allows rapid file trans­fers over the satellite network between host PCs that are running the client VFS application. To activate the Vipersat File Streaming capabilities of the CDD-56X, toggle this command to Enabled by entering R at the command prompt.
Once the parameters on the Feature Configuration screen have been set as desired, return to the Main Menu and enter the V command to display the Vipersat Configuration screen shown in figure 3-6.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-8 Vipersat CDD-56X Series User Guide
Vipersat Configuration
Entering V at the prompt from the CDD-56X Main Menu shown in figure 3-1 displays the Vipersat Configuration menu shown in figure 3-6.
Figure 3-6
Vipersat Configuration screen (Hub)
This menu lists the available commands for configuring a Vipersat CDD-56X. Note that for the Hub unit only, the command Primary Heart Beat is displayed in the Vipersat Configuration screen. For the Remote unit only, the status of the Home State Revert setting is displayed.
Each of these commands is explained in the following sections.
STDMA Mode
The STDMA Mode parameters for this CDD-56X are accessed by entering T at the Vipersat Configuration screen command prompt.
The items in the STDMA menu will vary depending on the function the target CDD-56X performs in the network (Hub or Remote) and the Hub Type that is designated. The STDMA screen shown in figure 3-7 is from a CDD-56X serv­ing as a Hub with STDMA in the network. The Hub Type is designated as Fixed, in this example.
For comparison, the STDMA screen for a CDD-56X operating in SCPC mode (either as a Hub expansion unit or as a Remote mesh unit) is shown in figure 3-8. Note that some of the command items differ between these two screens, and most of the items on the SCPC menu are information-only display..
Chapter 3 - Using the Command Line Interface (CLI) 3-9
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
Figure 3-7
STDMA screen (Hub, STDMA, Fixed type)
Figure 3-8
STDMA screen (Hub/Remote, SCPC)
STDMA
This menu item is read-only and shows the current state of STDMA in the CDD-56X. In order to change the STDMA state, refer to the section “Feature Configuration” on page 3-5.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-10 Vipersat CDD-56X Series User Guide
STDMA Tx Rate
This menu item shows the STDMA Transmit Rate (in bps) of data that the CDD-56X receives. This item is read-only and cannot be modified in this menu.
Hub Type
This menu item is only displayed if the CDD-56X is being used as a Hub in the network, and provides the functionality for the STDMA Burst Controller. Vipersat STDMA has six modes of operation:
Fixed — all remotes get the same data slot time (slot size) in the cycle,
regardless of activity. Cycle time is fixed also.
Dynamic Slot — data slot time of remotes vary according to activity,
cycle time does not.
Dynamic Cycle — slot time and cycle time vary according to activity of
remotes.
GIR (Guaranteed Information Rate) — each remote always has at least the
minimum data slot size when needed, and cycle time is variable up to a maximum of one second.
Entry Channel — remotes run in SCPC mode, but STDMA is used for
maintenance and control channel.
ECMv2 — utilizes a modified slotted Aloha method for remotes to
establish registration in the network and obtain the means for switching into SCPC mode.
The Hub can be configured to operate as one of the six types by entering a T at the command prompt to display the dialog shown in figure 3-9.
Figure 3-9
Hub Type prompt
This selection determines whether available bandwidth will be a static (fixed) assignment, or whether bandwidth allocation will be dynamic with automatic switching to dynamically optimize bandwidth utilization.
Chapter 3 - Using the Command Line Interface (CLI) 3-11
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
Refer to Appendix B, “Automatic Switching”, for additional information on how each of the bandwidth allocation modes functions and the parameters used to calculate the commands for each mode.
1 – Fixed
In the Fixed mode, all remotes have the same data slot size regardless of type of traffic or load. This mode minimizes the amount of jitter between remote trans­mission times, and is useful for tuning STDMA as well as for troubleshooting purposes.
2 – Dynamic Slot
In the Dynamic Slot mode, slot size is adjusted each cycle depending on the activity during the previous cycle. The slot size for each remote is computed based on the time (at the current data rate) needed to transmit all the bytes in queue. If the result is less than the minimum slot size or more than the maxi­mum slot size, the slot is adjusted accordingly. This mode allows the burst controller to provide additional slot time in the cycle to remotes with higher traffic demands, and helps to alleviate congestion.
3 – Dynamic Cycle
In the Dynamic Cycle mode, available bandwidth is allocated to remotes proportionally based on their current bandwidth needs. The bandwidth require­ments are determined by the number of bytes in queue for each remote divided by the total number of bytes in queue for all remotes, and results in the percent­age of bandwidth to allocate for each remote. This mode provides improved efficiency of STDMA due to faster cycle times during periods of light traffic demands, thus providing minimum latency for the current load.
4 – GIR
In the GIR mode, the initial computed slot size value is the same as in the Dynamic Cycle mode except there is no maximum limit. After all remotes have been assigned slots, the burst map is checked to see if the total cycle length exceeds one second. If not, then all requirements are satisfied and the burst map is complete. However, if the cycle is greater than one second, then the slots are adjusted proportionally so that all remotes receive at least their guaranteed rate plus whatever excess is still available.
GIR mode allows guaranteed information rates to be set for each remote in the group. When the one second restriction is exceeded, remotes without a specified GIR are reduced to the global minimum slot size and the remaining bandwidth is distributed to remotes that have been assigned a GIR rate, thus ensuring addi­tional bandwidth to these units when needed.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-12 Vipersat CDD-56X Series User Guide
Note: GIR allocations are restricted so that assigned GIR totals cannot exceed
the available bandwidth. This ensures proper bandwidth allocation when the network is overloaded.
The GIR setting for each Remote is specified using the STDMA Remote Poli­cies screen (refer to the section “Set Remote Policies” on page 3-24). When combined with Auto switching, GIR allows trigger points to be set where the Remote will jump out into SCPC mode. This is done using the Load Switch setting. Note that, for this function, Auto switching must be Enabled on this Hub unit, and corresponding Remote modems must be configured with Auto switching and Load switching Enabled. Also, the settings for Step Up and Step Down Threshold values should be adjusted as necessary for the application.
5 – Entry Channel
The Entry Channel mode provides remotes in the group with a shared channel in which they can gain initial access to the network. Since very small STDMA data rates are required in this configuration, a larger number of remotes can share the cycle. As soon as the Hub receives an STDMA ACK from the Remote, it initiates an immediate switch to SCPC mode based on the policy set for that Remote. Note that the switch occurs as soon as the Hub receives an ACK even though there may not be traffic at that time. The persistence of the link will be determined by the unit’s flag settings.
When choosing Entry Channel as the Hub type for the STDMA Controller, the Auto switching feature must be Enabled on this Hub unit, and switching policies for the remotes must be configured (refer to the section “Set Remote Policies” on page 3-24). Corresponding Remote modems must be configured with Auto switching and Load switching Enabled. Note that the settings for Step Up and Step Down Threshold values should be adjusted as necessary for the applica­tion.
This mode is designed to accommodate the needs of a Remote that will not be continuously connected to the network, but which has the need to be able to make an on-demand connection when required, such as in a mobile application. In the event of a power outage, Entry Channel provides a bandwidth-efficient method for remotes with low latency requirements to re-enter the network once power is restored.
6 – ECMv2
The ECMv2 (Dynamic Entry Channel) mode is very similar to the regular Entry Channel mode. However, the associated limitation in the number of Remotes is eliminated via the modified slotted Aloha method that is utilized for this mode. No cycle is used, and a Remote List is not necessary.
The Hub broadcasts an anouncement message to all Remotes that are tuned to receive it that provides the available slots and the tuning parameters for trans-
NOTE
Chapter 3 - Using the Command Line Interface (CLI) 3-13
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
mitting back to the Hub. The Remotes transmit on a contention basis and should a collision occur, the Remote will back off for a specified period and try again. Once it obtains one of the available slots, the Remote will hold onto the slot until it registers with the VMS and receives assignment into dSCPC, or until all necessary transactions are completed. The slot is then released for use by another Remote unit that is attempting to enter the channel.
Remotes can be set to one of four operating modes—Disable, Offline, Wait, and Online—from the ECMv2 Mode command in the STDMA menu. In addition, commands for setting parameters to accomodate any mismatches between the Hub LNB and the Remote BUCs are presented: LNB LO Frequency (Hub), BUC LO Frequency (Remote), and Satellite Conversion Frequency.
ECMv2 Mode
This menu item appears for Hub expansion and Remote expansion units operat­ing in ECMv2 only.
Each unit can be set to a designated mode of operation in ECM:
Disable – the ECM function for this unit is disabled.
Offline – the unit will not transmit (muted).
This mode may be chosen for radio silence applications.
Wait – the unit will register with the controller and remain in the ECM
wait queue without assignment for switching into dSCPC mode. This mode may be chosen by operators who wish to manually control (via diagnostic switch) when a unit is to be switched and utilize bandwidth from the pool.
Online – the unit will register with the controller and request dSCPC
bandwidth for switching.
In order for a unit to automatically switch into SCPC mode and pass data traffic, the ECMv2 Mode must be set to Online.
Figure 3-10
ECMv2 Mode prompt
Tip: For purposes of commissioning the terminal with a continuous carrier, the
Entry Channel mode can be set temporarily to Disable. Once this process is completed, set the Remote back to the desired mode for normal operation.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-14 Vipersat CDD-56X Series User Guide
Group ID
The STDMA Group ID number defines a group of equipment (including CDD-56X Hub and Remote units) that will respond to the output of a single STDMA burst controller. This group is addressable within a network which, in turn, is defined by the Network ID number assigned to the CDD-56X.
Allocation of bandwidth is shared among the remotes in an STDMA group. Depending on the number of remotes in a network, a Hub may have multiple burst controllers, each with its own set of remotes. This is accomplished by assigning a unique Group ID number to each controller and its associated remotes.
Note: The STDMA Group ID number and the Network ID number are indepen-
dent. There can be multiple STDMA groups within a single network.
The target CDD-56X Group ID can be modified by entering an I at the command prompt to display the dialog shown in figure 3-11.
Figure 3-11
Group ID prompt
STDMA Max Power Hunt
This menu item appears for Remote modems only.
Should link reception from a Remote be incorrect or impaired (e.g., poor envi­ronmental conditions), the STDMA Max Power Hunt feature is an option on the Remote modem that automatically adjusts the Remote transmit power to ensure that burst map acknowledgements from that unit are received by the Hub burst controller. When enabled, the burst controller sets a flag in the burst map that indicates it is not receiving acknowledgements from an enabled Remote. When the Remote receives the burst map, it will see the flag and automatically increase power up to the maximum value specified with this parameter (3, 6, or 9 dB) above the default or Home State setting. If this closes the link, the burst controller will clear the flag. Note that if the dB increase is more than is neces­sary, DPC will make a down adjustment to the appropriate level and this adjust­ment will be added to the DPC Offset.
NOTE
Chapter 3 - Using the Command Line Interface (CLI) 3-15
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
This feature option is Enabled/Disabled by entering H at the command prompt.
Figure 3-12
STDMA Max Power Hunt prompt
Low Data Rate Fast Acquisition
Configurable on a Hub Burst Controller only.
This menu item is a toggle used to Enable or Disable the Vipersat Burst Fast Acquisition Timing (BFAT) feature that functions at low data rates (64 kbps to 256 kbps). This feature allows for significantly faster acquisition times at these data rates, even with higher noise, resulting in improved efficiency of the shared STDMA channel. Since signal lock is faster at higher data rates, BFAT is not active above 256 kbps.
Entering A at the command prompt will toggle this feature On or Off.
This feature requires Router firmware version 1.5.3 or later. The unit configura­tion must be set for operation at either 3/4 QPSK or .95 QPSK in order to utilize BFAT.
Note: Use of BFAT is NOT recommended with ECMv2.
When this feature is enabled with any other STDMA allocation method, the Preamble parameter becomes fixed (not settable by the user) and this value is automatically determined by the system—appears as display only in the CLI; not displayed in the Parameter Editor.
Burstmap Multicast IP
This menu item is used to define the IP address for the Burstmap Multicast that is sent out by the STDMA burst controller at the Hub to all of the associated remotes in that group. This address must be the same for all members of the goup. The burstmap is a proprietary message sent from the Hub to all remotes, at regular intervals, specifying the relative start time and duration for each terminal to transmit.
To change the current address, enter N at the command prompt to display the dialog shown in figure 3-13.
NOTE
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-16 Vipersat CDD-56X Series User Guide
Figure 3-13
Burstmap Multicast IP prompt
Outbound IP
This menu item, which appears for all Hub configurations, displays the current Outbound IP address. This specifies the Hub device that is supplying the TDM outbound to the satellite (typically a CDM-570L). Specifying this address is necessary for Hub configurations that utilize a burst controller (such as the CDD-56X) that is a separate device from the TDM modem.
This address must also be defined when using the following features:
DPC
SOTM
The Outbound IP address will be the same as the burst controller IP address when the burst controller and the TDM modem are the same device.
To define the TDM outbound address, enter O at the command prompt to display the dialog shown in figure 3-14.
Figure 3-14
Outbound IP prompt
Cycles Per Burst Map
This menu item, which appears for Hub types Fixed, Dynamic Slot, and Entry Channel, displays the number of spin cycles that will occur prior to each broad-
cast of the Burst Map by the burst controller to the remotes. One cycle is the amount of time it takes for all remotes in a group to burst on the common chan­nel. The burst map provides each remote with its allocated bandwidth and posi­tion in the cycle.
Chapter 3 - Using the Command Line Interface (CLI) 3-17
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
For Dynamic Cycle and GIR configurations, the number of cycles is automati­cally set to one in order to ensure optimum performance for these Hub types.
This parameter can be modified by entering a C at the command prompt to display the dialog shown in figure 3-15.
Figure 3-15
Cycles per Burst Map prompt
Slot Guardband
This menu item, which appears for all Hub configurations, displays the current length of the Slot Guardband in milliseconds and in bytes for the remotes in the group. The Slot Guardband is the amount of time between the point when one remote completes transmitting data and the point when the next remote in the cycle begins transmitting. This prevents the remote from overrunning the next terminal in the cycle. The setting for this parameter should be obtained using the Vipersat STDMA calculator.
Tip: For a copy of the latest Viper Calculator, contact a Comtech Vipersat
Networks representative.
This value can be modified by entering a G at the command prompt to display the dialog shown in figure 3-16 and entering a new value.
Figure 3-16
Slot Guardband prompt
Note: The value entered at the command line in figure 3-16 is in milliseconds.
The corresponding value expressed in bytes is calculated by the
NOTE
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-18 Vipersat CDD-56X Series User Guide
CDD-56X based on the STDMA transmit bit rate as shown in the menu in figure 3-7.
Slot Preamble Length
This menu item, which appears in all Hub and Remote configurations, displays the current Slot Preamble size in milliseconds and bytes for the remotes in the group. The Slot Preamble is the period between when the remote begins to transmit (sends an ACK) to the Hub and when the first data packet is sent. This allows time for signal lock to occur before data is sent, thus preventing data loss. Higher data rates allow for a shorter preamble, since it is easier to achieve signal lock. The setting for this parameter should be obtained using the Vipersat STDMA Calculator.
Tip: For a copy of the latest Viper Calculator, contact a Comtech Vipersat
Networks representative.
Note: When either the BFAT feature is enabled or the Hub Type is ECMv2, the
preamble length is set automatically for the unit.
On a Hub unit, entering a P at the command prompt allows changing the pream­ble duration in milliseconds.
Figure 3-17
Slot Preamble Length prompt
Slot Data Length
This menu item, which appears for Fixed, Entry Channel, and ECMv2 Hub types, displays the current Slot Data Length in milliseconds and bytes for the remotes in the group, and represents the amount of data that can be transmitted or received in one spin of the STDMA cycle by each of the remotes belonging to that group. This is the amount of time that the remote is provided to send data in the cycle.
To change this setting, enter B at the command prompt to display the dialog shown in figure 3-18.
NOTE
Chapter 3 - Using the Command Line Interface (CLI) 3-19
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
Figure 3-18
Slot Data Length prompt
Nominal Data Length
This menu item, which appears for Dynamic Slot Hub type, displays the Nomi­nal slot Data Length in milliseconds and bytes for the remotes in the group,
and represents the approximate amount of data that can be transmitted or received in one spin of the STDMA cycle by each of the remotes belonging to that group. This is the amount of time that the remote is provided to send data in the cycle.
Entering a B at the command prompt brings up the dialog shown in figure 3-19 allowing changing the nominal data length, in milliseconds, for the target CDD-56X.
Figure 3-19
Nominal Data Length prompt
Maximum Data Length
This menu item, which appears for Dynamic Cycle Hub type, displays the current Maximum Data Length in milliseconds and bytes for the remotes in the group, and represents the maximum amount of data that can be transmitted or received in one spin of the STDMA cycle by each of the remotes belonging to that group. This is the maximum amount of time that the remote is provided to send data in the cycle.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-20 Vipersat CDD-56X Series User Guide
To change this setting, enter B at the command prompt to display the dialog shown in figure 3-20.
Figure 3-20
Maximum Data Length prompt
Minimum Data Length
This menu item, which appears for Dynamic Slot, Dynamic Cycle, GIR, and Entry Channel Hub types, displays the current Minimum Data Length in milli-
seconds and bytes for the remotes in the group, and represents the minimum amount of data that can be transmitted or received in one spin of the STDMA cycle by each of the remotes belonging to that group. This is the minimum amount of time that the remote is provided to send data in the cycle.
Entering an M at the command prompt brings up the dialog shown in figure 3-21 allowing the minimum data length, in milliseconds, to be changed for the target CDD-56X.
Figure 3-21
Minimum Data Length prompt
Total Slot Count
This menu item appears for Hub units operating in ECMv2 only.
Chapter 3 - Using the Command Line Interface (CLI) 3-21
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
This parameter defines the number of time slots per cycle available for assign­ment to the Remotes in queue that are to be switched from ECM into dSCPC. These are the Remotes that are tagged for Online mode. By design, ECM works on a contention basis, with the number of slots being some fraction of the total number of Remotes. In order for this ratio to be optimized, a Vipersat calculator is available to determine this setting.
Tip: Contact a Comtech Vipersat Networks representative for a copy of the
latest Vipersat ECM Calculator.
Entering R at the command prompt allows changing the slot count. Valid range is 1 to 255.
Figure 3-22
Total Slot Count prompt
Slot Cycle Length
This menu item is for information only and displays the Slot Cycle Length in milliseconds and bytes for the remotes in the group. This value represents the total amount of time—preamble, data length, and guardband—allocated to the Remote terminal during one spin cycle.
Slot Start in Cycle
This menu item appears in the STDMA screen when the Unit Role is Remote; however, it is not relevant since a Remote configuration does not enable STDMA.
Set Remotes
This menu item appears in the STDMA screen when the Unit Role is Hub with No Expansion, except for Hub Type ECMv2.
Entering an R at the command prompt displays the STDMA Remotes Menu as shown in figure 3-23. This screen is used to define and make modifications to the Remotes that belong to the STDMA group for the Hub burst controller, as well as to display the burst map status information for each Remote.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-22 Vipersat CDD-56X Series User Guide
Figure 3-23
STDMA Remotes Menu screen
Adding a Remote to the STDMA Group
Entering the item number for the Remote demodulator/router brings up the dialog shown in figure 3-24. A prompt to enter the Name to assign to the Remote unit appears, followed by a prompt to enter the IP Address for this unit.
Figure 3-24
Remote Name and IP Address prompt
Once a Remote has been added to the group, its Status in the group is displayed by the use of the following letters:
U = Used – This Remote is being used in the burstmap.
Once a remote has been added to the STDMA group, this status will always be displayed.
B = Burstmap – This Remote is currently in the burstmap.
This status will be displayed unless the remote has been removed (R), disabled (D), or switched (S) out of the STDMA burstmap.
Chapter 3 - Using the Command Line Interface (CLI) 3-23
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
R = Removed – This Remote is currently removed from the burstmap.
When displayed, this status indicates that the Hub has removed this remote from the burstmap due to a communications fault.
D = Disabled – This Remote is currently disabled and is not in the
burstmap. This status will be displayed when a remote is manually disabled by the operator or administrator.
S = Switched – This Remote is currently switched into SCPC mode.
When displayed, this status indicates that the VMS has automatically switched the remote out of the burstmap and into SCPC operation.
H = Home State Revert – This Remote is not currently receiving burst
maps. When a remote, stuck in SCPC mode by failure to receive a VMS revert command, sees the burst map with this flag set, it will automatically revert to its home state and STDMA mode.
CF – This Remote has not sent an acknowledgement to the burst controller
since it was enabled.
Most commonly, either a B or an S will be displayed, as a typical Remote will be either Bursting or Switched out to the dSCPC pool.
Base
Entering a B at the command prompt in figure 3-23 allows entering the Remote number to start displaying remotes in this menu screen. Entering the number 1, as shown in figure 3-23, displays nine remotes, 1 through 9. If the number 4 had been entered, the display would show the nine remotes starting with Remote 4 (i.e., remotes 4 through 12).
Figure 3-25
Base Remote Display prompt
Remote Count
The Remote Count menu item in figure 3-23 is an information-only display showing the total number of Remotes that currently belong to the STDMA group for this Hub burst controller.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-24 Vipersat CDD-56X Series User Guide
Set Remote Policies
This menu item, which appears for GIR and Entry Channel Hub types, allows each Remote to be configured for specific data switching conditions.
For Hub STDMA Controllers operating in either GIR or Entry Channel mode, typical load switching is not the mechanism that performs the transition from STDMA to SCPC mode due to traffic load. In GIR mode, the Remote is switched to SCPC as soon as the GIR threshold is reached. In Entry Channel mode, the Remote is switched to SCPC as soon as the Hub receives the first transmission from the Remote.
For both GIR and ECM, the event of switching from STDMA to SCPC can only occur if the SCPC Switch Rate parameter is set to a value greater than 0 (zero). If the switch rate for a Remote is set to 0 kbps, that Remote will remain in STDMA mode and will only switch to SCPC mode due to an application switch or a diagnostic (manual) switch.
Entering P at the STDMA Remotes Menu command prompt displays the Remote Policies screens shown in figure 3-26 (GIR Hub) and figure 3-28 (Entry Channel Hub).
Figure 3-26
STDMA Remote Policies screen (GIR Hub)
Entering the Remote number at the command prompt in figure 3-26 allows the Guaranteed Information Rate and the Automatic Load Switch Rate for that Remote to be set, as shown in figure 3-27. Note that the Available Bandwidth is displayed for reference in this screen to assist with entering the appropriate rates. The cycle length for GIR is limited to a maximum of one second.
Chapter 3 - Using the Command Line Interface (CLI) 3-25
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
Set the Automatic Load Switch Rate to a value greater than the GIR to allow the Remote to be automatically switched out of STDMA and into SCPC mode when traffic exceeds the GIR. A Switch Rate of 0 will prevent the Remote from being switched out of STDMA and into SCPC mode.
Figure 3-27
GIR Remote Policies prompt
The Remote Policies screen for an Entry Channel Hub type allows the SCPC data rates and switch types to be specified for when the Remotes will switch and the desired starting points for communications.
Figure 3-28
Entry Channel Switch Rates screen
Entering the Remote number at the command prompt in figure 3-28 allows the SCPC Data Rate and the Switch Type for that Remote to be set, as shown in figure 3-29. Switch type 0 corresponds to Load Switching; switch types 64 through 255 are user-defined, and must match VMS policies. When choosing Load Switching as the Switch Type, the associated Remote must have the Load
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-26 Vipersat CDD-56X Series User Guide
Switching feature Enabled (see the section “STDMA/SCPC Automatic Switch­ing” on page 3-32).
Figure 3-29
Remote SCPC Data Rate prompt
The Global SCPC Rate command can be used to set the data rate for all or a majority of the Remotes. This allows the rate to be entered just once instead of entering the rate for each Remote individually. Enter G at the command prompt in figure 3-28.
Figure 3-30
Global SCPC Data Rate prompt
Similarly, the Global Switch Type command can be used to set the switch type for all or a majority of the Remotes. Enter H at the command prompt.
Figure 3-31
Global Switch Type prompt
Delete Remote
Entering D at the command prompt shown in figure 3-23 brings up the Delete Remote dialog shown in figure 3-32.
Chapter 3 - Using the Command Line Interface (CLI) 3-27
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
Figure 3-32
Delete Remote prompt
Enter the number of the Remote CDD-56X at the command prompt to delete it from the STDMA group for this Hub burst controller.
Enable/Disable Remote
Enter E at the command prompt in figure 3-23 to display the dialog shown in figure 3-33. The Remotes in the network are displayed, indicating whether each is currently Enabled (E) or Disabled.
Figure 3-33
Enable/Disable Remote prompt
Enter the number of the Remote at the command prompt to toggle the Remote from its current Enable/Disable configuration.
In the example screen shown above, both Remotes 1 and 2 are Enabled.
View Remote(s)
Entering V at the command prompt shown in figure 3-23 will display the listing of Remote(s) that belong to the STDMA group for this Hub burst controller, and their status, as shown in figure 3-34.
Figure 3-34
View Remote(s) screen
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-28 Vipersat CDD-56X Series User Guide
The display is for information only and pressing any key will return the screen to the menu shown in figure 3-23.
Remove Timeout
Entering R at the command prompt shown in figure 3-23 will display the Remove Timeout dialog shown in figure 3-35. Note that this menu item shows
the current setting (in seconds) for this parameter.
Figure 3-35
Remove Timeout prompt
The value entered at the command prompt defines the amount of time (in seconds) with no communication from a Remote to the Hub before that Remote is removed from the Burst Map. If communications are lost for this specified period of time, the Remote is removed from the STDMA group, and the band­width resources it had been allocated are then made available for use by the other remotes remaining in the group.
This feature is useful, for example, in an SNG application where a mobile Remote has finished its assignment and has shut down.
Remove Retry Timeout
Entering T at the command prompt in figure 3-23 will display the Remove Retry Timeout dialog shown in figure 3-36. Note that this menu item shows
the current setting (in seconds) for this parameter.
Figure 3-36
Remove Retry Timeout prompt
Chapter 3 - Using the Command Line Interface (CLI) 3-29
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
When a Remote is removed from the group Burst Map, as described in the section “Remove Timeout” above, entering a value in the Remove Retry Time­out dialog defines the amount of time (in seconds) that is allowed to pass before a retry attempt is made to return the removed Remote to the group. The Remote is re-entered into the burst map cycle; if the Remote does not burst back (ACK) to the Hub burst controller, it is again removed from the Burst Map.
This allows, again using a mobile Remote as an example, shutting down the Remote at one location, moving it to a new location, and then automatically re­establishing a connection to the satellite network.
LNB LO Frequency
This menu item appears for an ECMv2 Hub type only.
This parameter, together with the Satellite Frequency Conversion setting, is crit­ical for determining RF frequency translations between Hub and Remote offsets or data spectral inversions. Take care in setting these correctly.
Enter Z at the command prompt and specify the correct LNB Local Oscillator frequency (MHz) that this Hub unit will be receiving.
Figure 3-37
LNB LO Frequency prompt
Satellite Frequency Conversion
This menu item appears for the ECMv2 Hub type only.
This parameter, together with the LNB LO Frequency setting, is critical for determining RF frequency translations between Hub and Remote offsets or data spectral inversions. Take care in setting these correctly.
Enter F at the command prompt and specify the correct Satellite Frequency Conversion value (MHz) that this Hub unit requires.
Figure 3-38
Satellite Frequency Conversion prompt
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-30 Vipersat CDD-56X Series User Guide
STDMA Statistics
Entering V at the command prompt in the STDMA screen displays the STDMA Statistics screen as shown in either figure 3-39 (Hub) or figure 3-40 (Remote).
Note that statistics will only be accumulated for a CDD-56X that is configured as a Hub with No Expansion, since that is the only configuration that provides STDMA functionality (on Demod 1). Because a Remote unit is SCPC mode only, the STDMA Statistics screen will display all values as 0.
Figure 3-39
STDMA Statistics screen (Hub)
Figure 3-40
STDMA Statistics screen (Remote)
Stats Accumulation Window
Entering W at the command prompt displays the Stats Accumulation Window as shown in figure 3-41. The time period, in seconds, for capturing STDMA statistics can be specified.
Chapter 3 - Using the Command Line Interface (CLI) 3-31
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
Figure 3-41
Stats Accumulation Window prompt
Clear
The STDMA statistics can be Cleared (reset) by entering a C at the command prompt in figure 3-39.
Show Hub Statistics
Entering a W at the command prompt in the STDMA screen displays the current statistics for the target CDD-56X Hub as shown in figure 3-42.
Figure 3-42
Show Hub Statistics screen
Statistics in the received ACK from each Remote are monitored by the Burst Controller. These statistics report the fill status of the burst data slot for each Remote. The Burst Controller builds a table of the group and calculates the rela­tive data byte count for each Remote. It then calculates the length of the Data Slot for each Remote based on the Minimum Slot Length plus a percentage of the Available Bandwidth. Idle Remotes receive a data slot equal to the Mini­mum Slot Length.
In figure 3-42, Remote 1 with IP address 10.1.128.1 had activity during the averaging period. It captured 37.8% of the total slot time and had an average slot length of 283 ms. Remotes 2, 3, and 4 had 41.5%, 18.1% and 7.6% respec­tively. The dynamic range of STDMA is a function of the difference between the Nominal Data Length and the Minimum Data Length parameters. These
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-32 Vipersat CDD-56X Series User Guide
parameters are operator selectable. The speed with which STDMA reacts to changes in dynamic load is a function of the Statistics Accumulation Window parameter and the Cycles per New Burst Map parameter, both of which are also operator selectable.
The Hub statistics are useful for tuning the Burst Controller. Preamble adjust­ments, up or down, are made using the missed ACKs statistic; a preamble and/ or guardband that is too short will result in an accumulation of missed ACKs. The “Cont” column represents continuous—the number of sequential ACKs missed.
An informative indicator in the Hub Statistics screen is the STDMA status of the Remotes that appears in the first column to the right of the IP Address list. The Remote status is displayed in one of three possible modes:
E – Remote is Enabled and active in the STDMA group; the Hub burst
controller is receiving ACKs from this Remote.
ER – Remote is Enabled but has been Removed from the STDMA group
due to missed ACKs at the Hub burst controller.
(Blank) – Remote either has been manually Disabled, such as through the
STDMA Remotes Menu Enable/Disable command, or has been switched out of STDMA to SCPC mode by the VMS.
STDMA/SCPC Automatic Switching
One of the most powerful features of the Vipersat Network system is the capa­bility to perform Automatic switching between STDMA mode and SCPC mode based on bandwidth demand. The configuration options that are available to meet customer-specific requirements are extensive, and include switching based on Load, Application (Voice and Video RTP), ToS, and QoS.
For additional information, refer to Appendix B, “Automatic Switching”, in this document.
Note: Care must be taken when configuring the Auto Switching features of the
Vipersat system to ensure that there is no duplication or overlap of switching functions between Application, ToS, and QoS for a particular traffic flow. Only one of these switching methods should be utilized for any one flow requirement.
Automatic Switching for the CDD-56X is an option that is available only when configured as an STDMA Hub unit (burst controller). Note that Automatic switching does not apply to either a Hub Expansion unit or a Remote Expansion unit; these Vipersat working modes operate in dedicated SCPC mode and all
NOTE
Chapter 3 - Using the Command Line Interface (CLI) 3-33
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
switching control is performed by the VMS. As is shown in table 2-2, Auto Switching should be Disabled for these two modes.
The Auto Switching feature must be Enabled (as described in the section “Feature Configuration” on page 3-5) in order to allow any associated Remote modems to perform STDMA/SCPC switching. In order for a Remote modem in the group to be automatically switched between STDMA and SCPC modes, the Auto Switching feature of that Remote must be Enabled as well.
Selecting Automatic Switching from the Vipersat Configuration menu shown in figure 3-6 (enter A) for a CDD-56X operating as a network Hub will display the menu shown in figure 3-43.
Figure 3-43
Automatic Switching screen
The following sections describe the menu items of the STDMA/SCPC Auto Switching screen shown in figure 3-43.
Auto Switching
The Auto Switching item on the menu shown in figure 3-43 is for information only and shows the current configuration of the Hub CDD-56X. This feature is Enabled and Disabled as described in the section “Feature Configuration” on page 3-5. Auto Switching must be Enabled in order to utilize any of the related features/commands in this menu.
Note that Auto Switching must be Enabled on a Hub STDMA Controller that is configured for either Entry Channel or ECMv2 mode.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-34 Vipersat CDD-56X Series User Guide
Current WAN Transmit Mode
The Current WAN Transmit Mode item on the menu in figure 3-43 is infor­mation only and reflects the current transmit status of a unit. In the case of the CDD-56X, there is no transmit function (no modulator) and this parameter is not applicable.
Load Switching
The Load Switching command on the menu in figure 3-43 is a toggle Enabling and Disabling Load Switching on the target Hub CDD-56X. The system will detect variations in data rate and can be configured to switch from STDMA to SCPC based on bandwidth requirements.
The initial switch for a Remote Vipersat terminal from STDMA mode to SCPC mode is determined by the Hub Burst Controller. Once the Remote is switched into SCPC, any requests to meet additional switching requirements within SCPC (Step Up or Step Down) are made by the Remote modem.
Entering a B at the command prompt will toggle this feature On or Off for the target CDD-56X.
Note: Load switching must be Enabled for any Hub CDD-56X burst controller
that will experience changing load conditions in order for the VMS to dynamically optimize network performance on these circuits.
Application switching by the VMS (Voice and/or Video) is not affected by this setting. However, using Load switching for real-time applications is not recommended.
STDMA Slot Capacity
The STDMA Slot Capacity command, shown in figure 3-43, allows setting the threshold or level of slot capacity at which the Burst Controller sends a switch request to the VMS to switch the Remote from STDMA mode to SCPC mode.
Enter U at the command prompt to display the dialog shown in figure 3-44.
Figure 3-44
STDMA Slot Capacity prompt
NOTE
Chapter 3 - Using the Command Line Interface (CLI) 3-35
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
A default setting (95%) is provided, but there may be unique network configura­tions which require modifying the STDMA Slot Capacity value.
STDMA Switch Delay
In order to minimize unnecessary switching from STDMA to SCPC due to tran­sient conditions, such as a temporary spike in network traffic for example, a switch delay parameter is provided. This setting is used to specify a delay before a switch occurs.
A default value (10 seconds) is provided, but this value can be changed to accommodate a unique network configuration or application. To change this setting, enter W at the command prompt in figure 3-43 to display the screen shown in figure 3-45.
Figure 3-45
STDMA Switch Delay prompt
Percent Allocation
The Percent Allocation menu item, shown in figure 3-43, allows adding a fixed percentage to the channel bandwidth request to accommodate additional band­width requirements which may occur after a switch is made from STDMA to SCPC mode.
To change this setting, enter E at the command prompt to display the screen shown in figure 3-46.
Figure 3-46
Percent Allocation prompt
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-36 Vipersat CDD-56X Series User Guide
Typically the default value will be optimum, but if there may be a larger band­width requirement after the switch, the percent allocation value can be increased. In choosing a value for this allocation, future bandwidth require­ments for the channel must be balanced against efficient bandwidth utilization.
Keep Alive Timer for Carrier Inhibit
This parameter applies to a Hub unit only. Note that, although this menu item also appears for a Remote unit, it does not apply to a switched demod unit at a remote site.
The Keep Alive Timer for Carrier Inhibit parameter provides a fixed setting that can be specified for the keep alive message sent to the Remotes from the Hub. This provides an alternate to the burst map which is variable and may become excessively long in certain applications. An example of this is a burst map containing a large number (up to 100) of remotes running in ECM mode where the burst period exceeds the Remote carrier inhibit timer.
When implemented, this parameter is set at either the TDM outbound unit or a switched demod, not at the STDMA Controller, in order to prevent a problem should the burst controller be rebooted.
Enter C at the command prompt in the Auto Switching screen to display the dialog shown in figure 3-47.
Figure 3-47
Keep Alive Timer for Carrier Inhibit prompt
Note that this timer setting should be at least three times faster (shorter in dura­tion) than the timer setting at the Remote(s) to ensure that network links are maintained.
Hitless Switching Parameters
Unless inherent delays in configuring both ends of a satellite bandwidth link during dynamic switching are accounted for, transmitted data may be lost during the transition. The time for a switch command to be sent across the satel­lite link (~ 250 ms), the command processing time, as well as receiver acquisi­tion time must be considered. The Vipersat Hitless Switching feature provides
Chapter 3 - Using the Command Line Interface (CLI) 3-37
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
a means to coordinate timing and utilize buffering to eliminate these data outages.
To access the Hitless Switching screen, enter H from the STDMA/SCPC Auto Switching screen (see figure 3-43).
Figure 3-48
Hitless Switching screen
This screen will initially display all lock times as -1, indicating that Hitless Switching is currently disabled. To enable the Hitless Switching feature, enter R at the command prompt to restore default lock times.
Delay for Mod
This parameter allows the operator to insert additional delay to buffer more data after modulator transmission is ceased. Enter M to modify this parameter.
Delay for Demod
This parameter allows the operator to insert additional delay to account for the tuning of the demodulator. Enter D to modify this parameter.
LockTimes
LockTime settings for the four data rates displayed can be adjusted either up or down, but default settings based on satellite testing should be used as a starting point. These defaults are stored in each modulator/demodulator unit and are restored by entering R at the command prompt.
Once restored, the lock time for each data rate can be modified by entering the corresponding number.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-38 Vipersat CDD-56X Series User Guide
Figure 3-49
Set LockTime prompt
To disable Hitless Switching, enter -1 for all lock times.
Apply Delay Values
To implement any modifications to the Hitless Switching parameters, enter A at the command prompt to apply these values to the modem.
SOTM Update
This menu item appears for both the Hub unit and the Remote unit. However, this feature is not applicable to the CDD-56X.
Unit Role
The Unit Role configuration determines whether the target CDD-56X is to function as a Remote or as a Hub in the Vipersat satellite network. From the Vipersat Configuration screen (figure 3-6), enter R to display the dialog shown in figure 3-50.
Figure 3-50
Unit Role prompt
The setting for this parameter, together with the setting for the Expansion Unit, will determine the role the target CDD-56X will perform in the network and what type of commands and functions it will receive from the VMS. See table 2-1 and table 2-2 for a breakdown of network roles and related functions and features.
Chapter 3 - Using the Command Line Interface (CLI) 3-39
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
Expansion Unit
The Expansion Unit menu item in the Vipersat Configuration screen (figure 3-6) defines whether the target CDD-56X is to function as an Expansion unit (all demods configured to operate in SCPC mode) or not. Entering E at the command prompt will display the dialog shown in figure 3-51.
Figure 3-51
Expansion Unit prompt
The VMS uses this data when monitoring and controlling the network to deter­mine the target CDD-56X’s function. For example, in a Hub configuration that has STDMA enabled for the first demod, Expansion Unit should be set to No.
When configured as an Expansion unit, either as a Hub (switched) or as a Remote (mesh), the CDD-56X is set up so that all demods are in SCPC mode and available as resources for dedicated communications with the other end of the satellite link.
For a Remote configuration, this parameter must be set to Yes. For a Hub configuration, this parameter can be set to either No or Yes. Refer to table 2-1 and table 2-2 for a breakdown of network roles and related functions and features.
Note: Setting Vipersat STDMA to Disabled alone will not force the demods into
an SCPC role—the Expansion Unit parameter must be set to Yes for this function. Likewise, Expansion Unit must be set to No together with STDMA Enabled for proper STDMA function.
Network ID
The Network ID that is assigned to the unit defines to what network the target CDD-56X will belong. All units used in a network will have the same Network ID. Enter B at the command prompt in the Vipersat Configuration screen (figure 3-6) to display the dialog shown in figure 3-52.
NOTE
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-40 Vipersat CDD-56X Series User Guide
Figure 3-52
Network ID prompt
The Network ID is used by the VMS to identify units that are common to a network and allows the VMS to manage multiple networks, each with its own unique Network ID number.
Unit Name
The Unit Name command in the Vipersat Configuration screen (figure 3-6) is used to assign a name to the target CDD-56X. Enter N at the command prompt to display the dialog shown in figure 3-53 . Any name, up to 16 characters, can be entered for the unit.
Figure 3-53
Unit Name prompt
This name is displayed by the VMS and identifies the unit in Network Manager, the graphical network display.
Receive Multicast Address
The Receive Multicast Address is the multitcast IP address assigned to all CDD-56X units in the Vipersat network that are managed by the VMS server. This address must match the VMS Transmit Multicast Address.
When the CDD-56X receives a multicast from the VMS server, it receives maintenance and control packets, including the server’s IP address. The
Chapter 3 - Using the Command Line Interface (CLI) 3-41
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
CDD-56X responds to the VMS server with a unicast containing its current configuration data, including the CDD-56X’s IP address. When the VMS receives the unicast response, it registers the CDD-56X on the network.
Enter V at the command prompt in the Vipersat Configuration screen (figure 3-6) to display the dialog shown in figure 3-54. Enter the Receive Multi­cast Address as assigned by the network operator/administrator.
Figure 3-54
Receive Multicast IP Address prompt
Managing IP Address
The Managing IP Address command in the Vipersat Configuration screen (figure 3-6) allows the IP address for the server running VMS to be entered. Enter I at the command prompt to display the dialog shown in figure 3-55.
Figure 3-55
Managing IP Address prompt
The Managing IP Address of the VMS is sent out with the multicast to all of the Vipersat units and will be automatically updated during the registration process. The CDD-56X sends a unicast registration request to the managing address every 60 seconds when requesting initial registration on the VMS network. Later the CDD-56X uses this address to send switch requests, network health status messages, etc. to the managing VMS server.
Note: The managing address will be set automatically if the Receive Multicast
Address is configured correctly and the unit is receiving the announce­ment multicast message. However, the unit WILL NOT send its registra­tion request message until this address is set.
NOTE
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-42 Vipersat CDD-56X Series User Guide
Once the unit is registered, the I command is removed from the Vipersat Configuration menu.
This managing address is automatically updated on a periodic basis for units that are newly enabled, incorrectly set, or following VMS changeovers (redun­dancy switching). The status of the registration process is displayed for this parameter as follows:
NOT-DEFINED — unit has booted up, but is unaware of the managing
address.
No STDMA Xmit Grant — operator has entered managing address, but
unit (Remote) is not currently receiving burst maps.
Sending Registration (n) — unit is receiving burst maps and the number
of registration attempts (n) is displayed.
Registered — unit is registered with the VMS. For VMS v3.6.0 and later,
the VMS version number is also displayed (as shown in figure 3-6).
Management Security
Management Security is an optional Vipersat feature that provides encryption on all VMS management messages passed between the VMS and the network modems. When enabled, the VMS and all of the network modems must utilize a common Encryption Key that is manually set on each. The key can be entered either as an ASCII hex string of exactly 64 characters, or as a passphrase consisting of 5 to 63 characters.
For modems that operate with Management Security, Enable this feature and enter the Encryption Key that has been defined for the network.
Note: VMS version 3.7.1 or greater is required for Management Security.
Caution: During the process of network-wide key distribution and enabling of
encryption, communications may be lost as the STDMA control messages will be unreadable until all modems in the network are configured.
It is recommended that each of the Remote units be configured for Management Security first, and then the Hub units be configured. This method will reduce the need for on-site personnel during feature implementation.
If the FAST feature key for Management Security has been purchased for the target modem, then it will appear as a menu item on the Vipersat Configuration screen (figure 3-6).
NOTE
Chapter 3 - Using the Command Line Interface (CLI) 3-43
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
Enter K at the command prompt to configure this feature, as shown in figure 3-56, below.
Figure 3-56
Vipersat Management Security screen
Enter M at the command prompt to toggle between Enabled/Disabled. Note that the feature must be set to Enabled in order to configure the encryption key.
Enter K at the command prompt and Enter the required key (figure 3-57). (Following entry, the characters will be temporarily displayed in the menu for reference pruposes.)
Figure 3-57
Encryption Key Entry prompt
Enter V at the command prompt and re-enter the same key to Verify it. (Following entry, the characters will be temporarily displayed in the menu for reference purposes.)
Enter G at the command prompt to execute the verfication process and Gener- ate the hex key. The Future Key menu item will display Valid to indicate successful verification of the key and that it is ready for activation.
Enter A at the command prompt to Activate the key for current use. The Current Key menu item will display Valid to indicate successful activation.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-44 Vipersat CDD-56X Series User Guide
Primary Heart Beat
This menu item appears for the Hub terminal only.
The Primary Heart Beat feature is a redundancy heart beat message for primary Hub units that provides the option for a periodic communications check message to be sent from the Hub modem to the VMS for backup recovery in N:M redundancy (protected) configurations. The message interval is hard-coded in the demod.
Enter P at the command prompt in the Vipersat Configuration screen (figure 3-6) to toggle this feature between Enabled and Disabled.
Home State Revert
This menu item appears for the Remote terminal only.
The Home State Revert feature allows automatic resource recovery to be performed on SCPC connections when a communications failure occurs between the VMS and a Remote, such as a rain fade condition, a Remote unit power down, or a hardware failure. The period of time (in minutes) for a failure is configured in the VMS for each Remote in the network. Should communica­tions be lost for more than the specified time period, the Remote will automati­cally revert to its Home State settings and the VMS will remove all allocated resources (bandwidth, demod(s)), freeing them for use by any other Remote in the Vipersat network.
Because this feature is configured in the VMS, the status (Disabled, or the time period in minutes) appears as an information-only display in the Vipersat Configuration menu (figure 3-6).
Dynamic Power Control Configuration
Dynamic Power Control (DPC) is a Vipersat feature that acts to regulate the transmit power of the Vipersat satellite modem, such that the specified receive signal level (E
b/No
) is met for the receiving Vipersat units in the group. DPC is driven by the receiver demod, which notifies the transmitting modem of the current E
b/No
value.
Refer to Appendix C, “Dynamic Power Control”, in this document for addi­tional information on the DPC feature.
The Dynamic Power Control Configuration screen (enter C in the Vipersat Configuration menu) allows for setting the parameters for the CDD-56X power
Chapter 3 - Using the Command Line Interface (CLI) 3-45
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
levels. The information and commands in the menu will vary depending on the function the target CDD-56X performs in the network. The screen shown in figure 3-58 is from a unit serving as a Hub with STDMA (burst controller). Note, however, that the only parameter settings that apply to the CDD-56X are DPC Enabled, Speed Up EbNo, and Target DPC Address. Because all of the remaining settings shown in this screen are redundant to those configured in the satellite modem (CDM-570), they do not apply to the CDD-56X and can be disregarded.
For comparison, the DPC Configuration screen for a unit operating as a Hub or Remote with Expansion (SCPC mode) is shown in figure 3-59. Note that only the applicable settings appear in this screen.
Figure 3-58
DPC Configuration screen (Hub, STDMA)
Figure 3-59
DPC Configuration screen (Hub/Remote, SCPC)
Tip: The DPC feature will not function unless the Outbound IP address is
defined in the STDMA screen for the Hub BC modem.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-46 Vipersat CDD-56X Series User Guide
DPC Enabled
The DPC Enabled command (enter E) is a toggle that allows the Dynamic Power Control feature to be either Enabled or Disabled. The CDD-56X is shipped with the DPC Enabled menu item turned off (Disabled) to allow entrance link levels calibration during terminal setup.
Speed Up EbNo
Normally, the DPC message is sent every 60 seconds from each terminal in the network. If the current E
b/No
value of the terminal drops below the Speed Up EbNo set value, the corresponding terminal increases its message send rate to every 15 seconds until the current value becomes greater than the set value. This provides a loop speed up to rapidly regain link quality.
Enter Q at the command prompt in the DPC Configuration screen to access the Speed Up EbNo dialog shown in figure 3-60. The default value for this parame­ter is 5 dB.
Figure 3-60
Speed Up EbNo prompt
Target DPC Address
The Target DPC Address identifies the modem that is transmitting to this CDD-56X Demod, and will be receiving the DPC messages that provide the current E
b/No
value for this Demod. Typically, all Remotes will specify the Hub
modem that is supplying the TDM outbound carrier.
For STDMA Remotes, the Outbound IP address is sent out via the Burst Map, and the DPC Target for these Remotes is automatically mapped to that address.
The Target DPC Address command is used only for units that are Out-of-Band and will be utilizing the DPC feature. For In-Band units, the target addresses are handled automatically by the VMS.
To manually configure the target address for an Out-of-Band unit, enter the number corresponding to the appropriate Demod (1, 2, 3, or 4) at the command prompt to display the Target DPC Address dialog shown in figure 3-61.
Chapter 3 - Using the Command Line Interface (CLI) 3-47
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
Figure 3-61
Target DPC Address prompt
The STDMA Burst Controller (Demod 1 on a CDD-56X configured as Hub with No Expansion) is not permitted to specify a DPC Target because the demodulator is receiving multiple bursts very rapidly from all Remotes in the group and is unable to utilize DPC to control the transmit power of the Remote modems. However, the transmit power of the Burst Controller adjusts to meet the target E
b/No
values for the Remotes in the group. These Remotes and their
status and E
b/No
values are displayed in the Vipersat Summary screen, DPC
details (see “Vipersat Summary” on page 3-51).
Set Home State Parameters
A CDD-56X’s Home State consists of those parameters which provide a known RF configuration that the CDD-56X will return to, either as the result of a command by the VMS, or as it comes back on line from a reset or a power cycle.
Enter H at the command prompt in the Vipersat Configuration screen to display the Home State Configuration screen shown in figure 3-62.
A CDD-56X’s Home State settings are typically selected so that it goes to a configuration which is optimum for its function in the network. These parame­ters are configured on an individual, per demod basis.
Note that each of these Receive parameters are the same as found in the Rx Configuration screen that is in the Satellite Demod Configuration menu.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-48 Vipersat CDD-56X Series User Guide
Figure 3-62
Home State Configuration screen
Set Current Configuration as Home State
This command sets the selected Demod’s current configuration as its Home State settings. Assuming the Demod has been properly configured using the
Satellite Demodulator Configuration menu (Rx parameters) and the Feature Configuration menu (Vipersat STDMA setting), these parameter values will be
copied into the Home State configuration. Rather than entering each of these values individually, this command can be used as a shortcut for establishing the Home State settings.
Enter W at the command prompt in the Home State Configuration screen to execute this command. Once saved, the modem will be configured with the Home State settings at boot time and when manually reset with the Force Modem to Home State command.
Tip: This command is useful when a CDD-56X’s initial set up is completed and
the unit is functioning as desired in a network.
Force Modem to Home State
If at any time it is desired to have a CDD-56X return to its Home State, this command (enter Y) can be executed. A warning message is displayed as shown in figure 3-63, requiring the command to be confirmed before it is executed.
Chapter 3 - Using the Command Line Interface (CLI) 3-49
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
Figure 3-63
Force Modem to Home State warning
This command will force the selected Demod to its Home State configuration, replacing its current configuration.
STDMA State
This command (enter T) toggles the setting of STDMA in the target CDD-56X’s Home State between Enabled and Disabled. This is the same feature that is set from the Feature Configuration menu screen shown in figure 3-4. Setting the STDMA State to Enabled is only applicable for a CDD-56X that is configured as a Hub burst controller.
Note: Only one demod can be set with STDMA enabled. Vipersat recommends
that Demod 1 be utilized for applications calling for STDMA.
Receive Frequency
Enter M to use the dialog shown in figure 3-64 to set the Receive Frequency for the selected Demod’s Home State.
Figure 3-64
Receive Frequency prompt
Note that this screen dialog example displays the frequency range for a CDD­562L/564L L-Band Demodulator/Router. For a CDD-564, the range displayed will be either 50 to 90 MHz or 100 to 180 MHz.
Receive Data Rate
Enter N to use the dialog shown in figure 3-65 to set the Receive Data Rate for the selected Demod’s Home State.
NOTE
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-50 Vipersat CDD-56X Series User Guide
Figure 3-65
Receive Data Rate prompt
Note that the valid range for this parameter will vary depending on the Demod­ulation Type, Coding Rate, and FAST feature Data Rate.
Receive FEC Type
Enter O to use the dialog shown in figure 3-66 to set the Receive FEC Type for the selected Demod’s Home State. Turbo must be selected when operating in Vipersat mode.
Figure 3-66
Receive FEC Type prompt
Receive Coding Rate
Enter P to use the dialog shown in figure 3-67 to set the Receive Coding Rate for the selected Demod’s Home State.
Figure 3-67
Receive Coding Rate prompt
Chapter 3 - Using the Command Line Interface (CLI) 3-51
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
Note that Coding Rate 6 (1/1) is not a valid selection when operating in Vipersat mode with Turbo Product Coding.
Receive Modulation Type
Enter Q to use the dialog shown in figure 3-68 to set the Receive Modulation Type for the selected Demod’s Home State.
Figure 3-68
Receive Modulation Type prompt
Vipersat Summary
The Vipersat Summary screen can be viewed by entering D at the command prompt in the Vipersat Configuration screen (figure 3-6).
Figure 3-69
Vipersat Summary screen
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-52 Vipersat CDD-56X Series User Guide
The Node ID number that appears in this screen verifies that the unit is regis­tered with the VMS and is active in the network. This number is automatically assigned by the VMS.
Note that the four Demods of the CDD-56X are designated as 0 through 3 on this screen. The IF values represent the Intermediate Frequency (Hz) that this unit is currently using. The AF values represent Adjusted Frequency (Hz), a translation of the IF that is used by the VMS for internal tracking of switching commands.
The DPC target entries are the IP addresses of the modulators that are to receive the Dynamic Power Control messages from the Demods for this unit.
The Primary Heart Beat Interval represents the time period between the communication check message that is sent from the primary Hub CDD-56X to the VMS in an N:M redundancy configuration. This interval is specified in the VMS.
Data for the Current Switch Cache reflects either the Home Satae information immediately after the unit boots, or the last switch command from the VMS (the last command sent to the base modem).
DPC details provide the status and E
b/No
values for active Remotes in the
group.
Vipersat Migration
The Vipersat Migration command is used to set the compatibility mode for the Hub Burst Controller when conducting a firmware upgrade on the associated Remotes. Although this command appears in the menu for both the Hub modem and the Remote modem, it only applies to STDMA Controllers and TDM Outbound modems at the Hub.
Enter M at the command prompt in the Vipersat Configuration screen to display the Vipersat Migration dialog shown in figure 3-70.
Refer to the specific upgrade procedure that is to be implemented for instruc­tions on whether/how to utilize this feature.
Chapter 3 - Using the Command Line Interface (CLI) 3-53
MN/22137, rev 1 Vi pe r sa t C o nf ig u ra ti o n
Figure 3-70
Vipersat Migration prompt
UDP Port Base Address
Should a particular network application require a specific UDP port base address be used, the default address can be changed by entering U at the command prompt in the Vipersat Configuration screen (figure 3-6).
Figure 3-71
UDP Port Base Address prompt
Caution: This command affects all communications for the VMS and STDMA.
If the base address is changed, it must be changed in the VMS as well as in all modems in all networks controlled by the VMS. The base address must also be changed when using VLOAD with this network.
Alerts
The Alerts menu item in the Vipersat Configuration screen is for information only and serves to display alert messages to the operator.
Vi pe r sa t Con f igu r at i on MN/22137, rev 1
3-54 Vipersat CDD-56X Series User Guide
Example: “Critical error: should not be in map
This alert typically occurs when there are multiple STDMA burst controllers at the Hub incorrectly configured with the same Group ID, thus causing Remotes to appear in more than one bursmap. A Remote may already be switched out into dSCPC mode, yet continue to appear in a burstmap that is received from another controller.
Appendix A - Network Addressing A-1
A
PPENDIX
NETWORK ADDRESSING
Introduction
This Appendix is an overview of network addressing and how it applies to configuring the CDD-562L/564/564L for use in Vipersat Networks. The subjects covered are:
OSI Model
Binary Math
IP Addressing
Network Address Translation
Subnets
Network Segments
Default Gateways
MAC Addresses
Th e O S I R ef e re nc e M o de l MN/22137, rev 1
A-2 Vipersat CDD-56X Series User Guide
The OSI Reference Model
OSI is an acronym for Open Systems Interconnection. This is a network model created by ISO (the International Standardization Organization.) The OSI model is the basic standard which forms the basis for all networking protocols.
Figure A-1
The Seven OSI Protocol Layers
The OSI model defines the building blocks used to construct a working network protocol as shown in Figure A-1. The blocks on the right show the individual layers which make up the OSI model and the blocks on the left show the layer’s functional grouping.
Each layer, as defined by the OSI model, is only aware of the layers directly above and below it.
Layers 1 – 3
Layer 1 / Physical Layer 1 defines the physical means by which actual bits are sent and received. This layer, for example, is where connectors, cable lengths, and signaling specifications are defined.
Layer 2 / Data Link – Layer 2 consist of two sub-layers:
Logical Link Control (LLC) – The LLC packages bytes received from the
MAC into a format readable by the Network Layer above it.
Media Access Control (MAC) – The MAC is concerned with obtaining
access to the network at an appropriate time; i.e., when no other machines are communicating or when permission has been granted.
Appendix A - Network Addressing A-3
MN/22137, rev 1 Th e O S I R ef e r e nc e M o de l
Together, these two sub-layer protocols are responsible for moving packets on and off the network.
Layer 3 / Network Layer – Layer 3 is responsible for routing packets through multiple networks. The Layer 3 protocol operates without regard to the underly­ing protocols in use. For example, routers operate at Layer 3.
Bi na r y Mat h MN/22137, rev 1
A-4 Vipersat CDD-56X Series User Guide
Binary Math
Network devices communicate using BITS, where a bit is a single digit repre­sented by a 1 or a 0, or by using BYTEs, where a byte is made up of eight bits in any combination of 1’s or 0’s. A byte is also referred to as an octet.
Figure A-2
Bits and Bytes
An octet can be converted to or from binary using the technique shown in the decimal conversion chart in Figure A-3. The conversion chart also shows the decimal equivalent of the binary number.
Figure A-3
Binary to Decimal Conversion
Bits containing a 1 in Figure A-3 determine which decimal values should be added. These decimal values, when added together, determine the decimal equivalent for the binary number.
This is an example of changing a number expressed in binary (base 2) to its decimal equivalent (base 10). The numeric value is the same, you have only
128 64 32 16 8 4 2 1
1
101 100 01 = 165
11 10 0 0 0 0 = 194
1111 11 11=255
128 32
4 1
_____
165
Appendix A - Network Addressing A-5
MN/22137, rev 1 Bi na r y M at h
changed the numbering base (radix.) All digital processes are done in binary. The conversion to decimal is done whenever binary values need to be read or entered by humans as their decimal equivalents.
IP Ad dr e ssin g MN/22137, rev 1
A-6 Vipersat CDD-56X Series User Guide
IP Addressing
An IP (Internet Protocol) address is a unique set of numbers assigned to a device on a network to uniquely identify that device (by its IP address).
An IP address is a unique number composed of four octets, with each octet separated by a dot. This notation style is called dotted decimal notation.
Each IP address can be broken down into two parts, as shown in the example below:
Example:
128.121.188.201
The first two octets are the network ID:
128.121
The second two octets are the host ID:
188.201
Network ID - In this example, the 128.121 portion of the IP address
defines the network that a host belongs to, and is equivalent to a street name in a mailing address.
Host ID - The 188.201 portion of the IP address specifies a unique number
assigned to the host on the network, and is equivalent to a house number in a mailing address.
IP Address Classes
IP addresses are assigned to classes according the schedule shown in Figure A-4. IP address classes are assigned as follows:
Class A
1.x.x.x to 126.x.x.x (0 and 127 are reserved)
126 Class As exist
Can have 16,777,214 hosts on each Class A
8-bit network number
24-bit node number
Class B
128.0.x.x to 191.254.x.x
16,384 Class Bs exist
Can have 65,354 hosts on each Class B
Appendix A - Network Addressing A-7
MN/22137, rev 1 IP A d d re ss i ng
16-bit network number
16-bit node number
Figure A-4
IP Address Classes A, B, C
Class C
192.0.1.x to 223.255.254.x
2,097,152 Class Cs exist
Can have 254 hosts on each Class C
24-bit network number
8-bit node number
Class D
224.0.0.0 to 239.255.255.255
Reserved for Multicast (messages sent to many hosts).
CLASS A
CLASS B
CLASS C
2,097,152
16,384
126
Networks Available
192-223.x.y.z
128-191.x.y.z
1-126.x.y.z
1
st
Octet
Decimal Range
254110 Class C
65,53410Class B
16,777,2140Class A
Hosts Available
High­Order-Bits
Address Class
2,097,152
16,384
126
Networks Available
192-223.x.y.z
128-191.x.y.z
1-126.x.y.z
1
st
Octet
Decimal Range
254110 Class C
65,53410Class B
16,777,2140Class A
Hosts Available
High­Order-Bits
Address Class
IP Ad dr e ssin g MN/22137, rev 1
A-8 Vipersat CDD-56X Series User Guide
Class E
240.0.0.0 to 255.255.255.255
Reserved for experimental use and limited broadcast
Private Network IP Addresses
RFC 1918 defines blocks of addresses for use on private networks:
10.0.0.0 – 10.255.255.255
172.16.0.0 – 172.31.255.255
192.168.0.0 – 192.168.255.255
Network Address Translation (NAT)
Private networks can only connect to the public Internet by using a Network Address Translation (NAT) device (a router, for example) or a proxy server which has been assigned a public IP address. These network devices use a public IP address to request information from the Internet on behalf of the private IP addressed devices on the associated private network.
Figure A-5
NAT Router Example
This use of private addresses helps to conserve public IP addresses.
Subnets
Subnets can be defined as the further segmentation of the InterNIC assigned Network ID IP address. The amount and type of subnetting performed by the organization is determined by the network layout.
Ethernet
Host 1
Host 2
NAT Router
Internet
192.168.0.2
192.168.0.3
192.168.0.1 Public IP
Appendix A - Network Addressing A-9
MN/22137, rev 1 IP A d d re ss i ng
In the process of subnetting, bits are borrowed from the host ID portion of an IP address and are then given to the network ID. Then a “Subnet Mask” gets assigned to the host along with the IP address.
Subnetting is required if the network is segmented.
Subnet Mask
The Subnet Mask is used by the host to determine if a destination IP address is on the local or on a remote network segment. The table in Figure A-6 shows the default subnet mask used for each class of IP address.
Figure A-6
Default Subnet Masks for IP Classes
The IP address and subnet mask work with each other to identify a network element or device. The subnet mask, like an IP address, contains 4 octets sepa­rated by a dot (.) and looks similar to an IP address.
The subnet mask determines what bits in the IP address are being used to deter­mine the network ID by using the Boolean math operator and in a process called anding. Anding compares each bit value in the IP address with the bit value in the subnet mask. The result of the anding process determines which subnet the IP address is on. The Boolean and operator works as follows:
0 and 0 = 0 1 and 0 = 0 1 and 1 = 1
The table shown in Figure A-7 shows the anding of two binary values and the corresponding decimal equivalents for each of the values.
11111111.11111111.11111111.00000000255.255.255.0Class C
11111111.11111111.00000000.00000000255.255.0.0Class B
11111111.00000000.00000000.00000000255.0.0.0Class A
Mask Binary ValueMask Decimal ValueAddress Class
11111111.11111111.11111111.00000000255.255.255.0Class C
11111111.11111111.00000000.00000000255.255.0.0Class B
11111111.00000000.00000000.00000000255.0.0.0Class A
Mask Binary ValueMask Decimal ValueAddress Class
CLASS A
CLASS B
CLASS C
IP Ad dr e ssin g MN/22137, rev 1
A-10 Vipersat CDD-56X Series User Guide
Figure A-7
ANDing an IP address and a subnet mask
A calculator, available from SolarWinds, performs these IP and subnet mask calculations and can be found at:
http://www.solarwinds.com/products/freetools/index.aspx
Network Segments
A “Network Segment” is a portion of a network that is bordered by two router interfaces as shown in Figure A-8.
Figure A-8
Network Segments
Each network segment must either be on a different network or a different subnet. For example, if you have a single IP address available, you can change the default mask from 255.255.255.0 to 255.255.255.192. The resulting calcula­tion yields four subnets:
192.168.100.0
192.168.100.64
192.168.100.128
192.168.100.192
ANDing Result
Subnet Mask
IP Address
11000000.10101000.00000010.00000000192.168.2.0
11111111.11111111.11111111.00000000255.255.255.0
11000000.10101000.00000010.01000010192.168.2.66
Binary Values
Dotted Decimal Address
ANDing Result
Subnet Mask
IP Address
11000000.10101000.00000010.00000000192.168.2.0
11111111.11111111.11111111.00000000255.255.255.0
11000000.10101000.00000010.01000010192.168.2.66
Binary Values
Dotted Decimal Address
Appendix A - Network Addressing A-11
MN/22137, rev 1 IP A d d re ss i ng
Each of the four subnets can, in turn, support 64 members.
The example subnet used above yielded 4 subnets, but you can use a different mask to meet the specific requirements of your network.
Default Gateways
A default gateway is a network device, usually a router, that is responsible for routing data packets out of the local network segment.
The address of the gateway is entered into the devices on the local network, providing them with a location to send data that is destined for another segment.
Figure A-9
Router as Default Gateway
MAC Addresses
A MAC address is a physical hardware address that gets assigned to the inter­face of a networking device. This address is typically created and burned into a device’s ROM during the manufacturing process. MAC addresses are unique to the device and are not typically user-assignable.
The MAC address is used for Layer 2 (Data Link) communications between networking devices, and consists of 12 alpha-numeric characters as shown in the example below:
Example: 00-3f-bf-00-01-45
IP Ad dr e ssin g MN/22137, rev 1
A-12 Vipersat CDD-56X Series User Guide
The first six characters are issued to the organization.
The second six characters are assigned to the hardware interface by
manufacturing.
Figure A-10
Network Node MAC Addresses
Loading...