Comstar B638215 User Manual

Safety Data Sheet
POWER CLEAN
SDS Revision Date:
Page 1 of 9
1. Identification
1.1. Product identifier
Product Identity
POWER CLEAN
Alternate Names
55-032, 55-033, Blended Formula, POWER CLEAN
1.2. Relevant identified uses of the substance or mixture and uses advised against
Intended use
See Technical Data Sheet.
Application Method
See Technical Data Sheet.
1.3. Details of the supplier of the safety data sheet
Company Name
ComStar International Inc.
20-45 128th Street,
College Point, NY 11356
Telephone No.
718-445-7900 800-328-0142 Fax: 718-353-5998
2. Hazard(s) identification
2.1. Classification of the substance or mixture
Skin Irrit. 2; H315
Cause skin irritation
2.2. Label elements
Using the Toxicity Data listed in section 11 and 12 the product is labeled as follows.
Warning
[Prevention]:
P261 Avoid breathing dust / fume / gas / mist / vapors / spray.
P271 Use only outdoors or in a well-ventilated area.
[Response]:
P312: Call a POISON CENTER or doctor / physician if you feel unwell.
P340 Remove victim to fresh air and keep at rest in a position comfortable for breathing.
[Storage]:
No GHS storage statements
[Disposal]:
Safety Data Sheet
POWER CLEAN
SDS Revision Date:
Page 2 of 9
No GHS disposal statements
3. Composition/information on ingredients
This product contains the following substances that present a hazard within the meaning of the relevant State and Federal Hazardous Substances regulations.
Ingredient/Chemical Designations
Weight %
GHS Classification
Notes
DIPROPYLENE GLYCOL MONOMETHYL ETHER CAS#: 34590-94-8
>15
Eye Irrit. 2B
[1][2]
SURFACTANT CAS#: 68648-81-7
<15
Not Classified
[1]
DEFOAMER CAS#: Not Est
<5
Not Classified
[1]
SODIUM GLUCONATE CAS#: 527-07-01
>10
Not Classified
[1]
Water & Other Non-hazardous compounds CAS#: N/A
Balance
Not Classified
[1]
In accordance with paragraph (i) of §1910.1200, the specific chemical identity and/or exact percentage (concentration) of composition has been withheld as a trade secret. [1] Substance classified with a health or environmental hazard. [2] Substance with a workplace exposure limit. [3] PBT-substance or vPvB-substance. *The full texts of the phrases are shown in Section 16.
4. First aid measures
4.1. Description of first aid measures
General
In all cases of doubt, or when symptoms persist, seek medical attention. Never give anything by mouth to an unconscious person.
Inhalation
Remove to fresh air, keep patient warm and at rest. If breathing is irregular or stopped, give artificial respiration. If unconscious place in the recovery position and obtain immediate medical attention. Give nothing by mouth.
Eyes
Irrigate copiously with clean water for at least 15 minutes, holding the eyelids apart and seek medical attention.
Skin
Remove contaminated clothing. Wash skin thoroughly with soap and water or use a recognized skin cleanser.
Ingestion
If swallowed obtain immediate medical attention. Keep at rest. Do NOT induce vomiting.
4.2. Most important symptoms and effects, both acute and delayed
Overview
No specific symptom data available. See section 2 for further details.
Inhalation
Harmful if inhaled.
Safety Data Sheet
POWER CLEAN
SDS Revision Date:
Page 3 of 9
5.1. Extinguishing media
Water fog, C02, dry chemical, universal foams
5.2. Special hazards arising from the substance or mixture
Hazardous decomposition: No hazardous decomposition data available.
Avoid breathing dust / fume / gas / mist / vapors / spray.
5.3. Advice for fire-fighters
Wear self-contained breathing apparatus and protective clothing.
ERG Guide No. ---
6.1. Personal precautions, protective equipment and emergency procedures
Put on appropriate personal protective equipment (see section 8).
6.2. Environmental precautions
Do not allow spills to enter drains or waterways.
Use good personal hygiene practices. Wash hands before eating, drinking, smoking or using toilet. Promptly remove soiled clothing and wash thoroughly before reuse.
6.3. Methods and material for containment and cleaning up
Absorb spill with vermiculite or other inert material, then place in a container for chemical waste. For Large Spills: Flush spill area with water spray. Prevent run-off from entering drains, sewers, or streams, collect run-off.
7.1. Precautions for safe handling
Avoid contact with eyes and skin. Wash thoroughly after handling. Do not breathe vapors or fumes.
Prevention of Fire and Explosion: Keep from contact with oxidizing materials, alkalis and acids. Store away from heat, sunlight and moisture.
See section 2 for further details. - [Prevention]:
7.2. Conditions for safe storage, including any incompatibilities
Handle containers carefully to prevent damage and spillage.
Incompatible materials: Oxidizing agents, alkali metals
See section 2 for further details. - [Storage]:
7.3. Specific end use(s)
No data available.
5. Fire-fighting measures
6. Accidental release measures
7. Handling and storage
Safety Data Sheet
POWER CLEAN
SDS Revision Date:
Page 4 of 9
8. Exposure controls and personal protection
8.1. Control parameters
Exposure
CAS No.
Ingredient
Source
Value
34590-94-8
DIPROPYLENE GLYCOL MONOMETHYL ETHER
OSHA
100 ppm
ACGIH
100 ppm
NIOSH
TWA 100 ppm (600 mg/m3) ST 150 ppm (900 mg/m3) [skin]
Supplier
No Established Limit
68648-81-7
SURFACTANT
OSHA
No Established Limit
ACGIH
No Established Limit
NIOSH
No Established Limit
Supplier
No Established Limit
Not Est
DEFOAMER
OSHA
No Established Limit
ACGIH
No Established Limit
NIOSH
No Established Limit
Supplier
No Established Limit
527-07-01
SODIUM GLUCONATE
OSHA
No Established Limit
ACGIH
No Established Limit
NIOSH
No Established Limit
Supplier
No Established Limit
N/A
Water & Other Non-hazardous compounds
OSHA
No Established Limit
ACGIH
No Established Limit
NIOSH
No Established Limit
Supplier
No Established Limit
Carcinogen Data
CAS No.
Ingredient
Source
Value
34590-94-8
DIPROPYLENE GLYCOL MONOMETHYL ETHER OSHA
Select Carcinogen: No
NTP
Known: No; Suspected: No
IARC
Group 1: No; Group 2a: No; Group 2b: No; Group 3: No; Group 4: No;
68648-81-7
SURFACTANT
OSHA
Select Carcinogen: No
NTP
Known: No; Suspected: No
IARC
Group 1: No; Group 2a: No; Group 2b: No; Group 3: No; Group 4: No;
Not Est
DEFOAMER
OSHA
Select Carcinogen: No
NTP
Known: No; Suspected: No
IARC
Group 1: No; Group 2a: No; Group 2b: No; Group 3: No; Group 4: No;
527-07-01
SODIUM GLUCONATE
OSHA
Select Carcinogen: No
NTP
Known: No; Suspected: No
IARC
Group 1: No; Group 2a: No; Group 2b: No; Group 3: No; Group 4: No;
Safety Data Sheet
POWER CLEAN
SDS Revision Date:
Page 5 of 9
N/A
Water & Other Non­hazardous compounds
OSHA
Select Carcinogen: No
NTP
Known: No; Suspected: No
IARC
Group 1: No; Group 2a: No; Group 2b: No; Group 3: No; Group 4: No;
8.2. Exposure controls
Respiratory
If engineering controls do not maintain airborne concentrations to an acceptable level, a
NIOSH approved respirator must be worn. Respirator Type: Organic vapor. If respirators are used, a program should be instituted to
assure Compliance with OSHA Standard 29 CFR 1910.134.
Eyes
Safety glasses with side shields, goggles or face shield are recommended.
Skin
Wear overalls to keep skin contact to a minimum.
Engineering Controls
Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. Supplementary local exhaust ventilation, closed systems, or respiratory protection may be needed in special circumstances such as poorly ventilated spaces, evaporation from large surfaces, spraying, heating, etc. Recommended Decontamination Facilities: Eye bath, washing facilities.
Other Work Practices
Use good personal hygiene practices. Wash hands before eating, drinking, smoking or using toilet. Promptly remove soiled clothing and wash thoroughly before reuse.
See section 2 for further details. - [Prevention]:
9. Physical and chemical properties
Appearance
Green Liquid
Odor
Slight
Odor threshold
Not Measured
pH
12 pH
Melting point / freezing point
Not Measured
Initial boiling point and boiling range
< 200 F
Flash Point
None
Evaporation rate (Ether = 1)
Not Measured
Flammability (solid, gas)
Not Applicable
Upper/lower flammability or explosive limits
Lower Explosive Limit: 135C(275F): NA
Upper Explosive Limit: 199C(390F): NA
Vapor pressure (Pa)
6 mmHg (at 70 F)
Vapor Density
Not Measured
Specific Gravity
< 2 (H20 = 1)
Solubility in Water
Complete
Partition coefficient n-octanol/water (Log Kow)
Not Measured
Auto-ignition temperature
(ASTM D 2155): NA
Decomposition temperature
Not Measured
Safety Data Sheet
POWER CLEAN
SDS Revision Date:
Page 6 of 9
Viscosity (cSt)
25C/77F: NA
Volatiles (% by weight)
NA Octanol/Water Partition Coefficient
NA 9.2. Other information
No other relevant information.
10. Stability and reactivity
10.1. Reactivity
Hazardous Polymerization will not occur.
10.2. Chemical stability
Stable under normal circumstances.
10.3. Possibility of hazardous reactions
No data available.
10.4. Conditions to avoid
No data available.
10.5. Incompatible materials
Strong Oxidizers
10.6. Hazardous decomposition products
No hazardous decomposition data available.
11. Toxicological information
Acute toxicity
Ingredient
Oral LD50,
mg/kg
Skin LD50,
mg/kg
Inhalation
Vapor LC50,
mg/L/4hr
Inhalation
Dust/Mist LC50,
mg/L/4hr
Inhalation
Gas LC50,
ppm
DIPROPYLENE GLYCOL MONOMETHYL ETHER (34590-94-8)
5230 mg/kg
Rat
>13,000 mg/kg
500 ppm
No data
available
No data
available
SURFACTANT (68648-81-7)
No data
available
No data
available
No data
available
No data
available
No data
available
DEFOAMER (Not Est)
No data
available
No data
available
No data
available
No data
available
No data
available
SODIUM GLUCONATE (527-07-01)
No data
available
No data
available
No data
available
No data
available
No data
available
Water & Other Non-hazardous compounds (N/A)
No data
available
No data
available
No data
available
No data
available
No data
available
Note: When no route specific LD50 data is available for an acute toxin, the converted acute toxicity point estimate was used in the calculation of the product's ATE (Acute Toxicity Estimate).
Classification
Category
Hazard Description
Acute toxicity (oral)
---
Not Applicable
Acute toxicity (dermal)
---
Not Applicable
Acute toxicity (inhalation)
---
Not Applicable
Safety Data Sheet
POWER CLEAN
SDS Revision Date:
Page 7 of 9
Skin corrosion/irritation
---
Not Applicable
Serious eye damage/irritation
---
Not Applicable
Respiratory sensitization
---
Not Applicable
Skin sensitization
---
Not Applicable
Germ cell mutagenicity
---
Not Applicable
Carcinogenicity
---
Not Applicable
Reproductive toxicity
---
Not Applicable
STOT-single exposure
---
Not Applicable
STOT-repeated exposure
---
Not Applicable
Aspiration hazard
---
Not Applicable
12. Ecological information
12.1. Toxicity
No additional information provided for this product. See Section 3 for chemical specific data.
Aquatic Ecotoxicity
Ingredient
96 hr. LC50 fish,
mg/l
48 hr. EC50 crustacea,
mg/l
ErC50 algae,
mg/l
DIPROPYLENE GLYCOL MONOMETHYL ETHER (34590-94-8)
>10,000, Pimephales
promelas
1919, Daphnia
Not Available
SURFACTANT (68648-81-7)
Not Available
Not Available
Not Available
DEFOAMER (Not Est)
Not Available
Not Available
Not Available
SODIUM GLUCONATE (527-07-01)
Not Available
Not Available
Not Available
Water & Other Non-hazardous compounds (N/A)
Not Available
Not Available
Not Available
12.2. Persistence and degradability
There is no data available on the preparation itself.
12.3. Bioaccumulative potential
Not Measured
12.4. Mobility in soil
No data available.
12.5. Results of PBT and vPvB assessment
This product contains no PBT/vPvB chemicals.
12.6. Other adverse effects
No data available.
Safety Data Sheet
POWER CLEAN
SDS Revision Date:
Page 8 of 9
13. Disposal considerations
13.1. Waste treatment methods
Observe all federal, state and local regulations when disposing of this substance.
14. Transport information
DOT (Domestic Surface Transportation)
IMO / IMDG (Ocean Transportation)
ICAO/IATA
14.1. UN number
Not Applicable
Not Regulated
Not Regulated
14.2. UN proper shipping name
Not Regulated
Not Regulated
Not Regulated
14.3. Transport hazard class(es)
DOT Hazard Class: Not
Applicable
IMDG: Not Applicable Sub Class: Not Applicable
Air Class: Not Applicable
14.4. Packing group
Not Applicable
Not Applicable
Not Applicable
14.5. Environmental hazards
IMDG
Marine Pollutant: No
14.6. Special precautions for user
No further information
15. Regulatory information
Regulatory Overview
The regulatory data in Section 15 is not intended to be all-inclusive, only selected regulations are represented.
Toxic Substance Control Act (TSCA)
All components of this material are either listed or exempt from listing on the TSCA Inventory.
WHMIS Classification
Not Regulated
US EPA Tier II Hazards
Fire:
No Sudden Release of Pressure:
No
Reactive:
No
Immediate (Acute):
No
Delayed (Chronic):
No
EPCRA 311/312 Chemicals and RQs:
To the best of our knowledge, there are no chemicals at levels which require reporting under this statute.
EPCRA 302 Extremely Hazardous:
To the best of our knowledge, there are no chemicals at levels which require reporting under this statute.
EPCRA 313 Extremely Hazardous:
To the best of our knowledge, there are no chemicals at levels which require reporting under this statute.
Proposition 65 - Carcinogens (>0.0%):
To the best of our knowledge, there are no chemicals at levels which require reporting under this statute.
Safety Data Sheet
POWER CLEAN
SDS Revision Date:
Page 9 of 9
Proposition 65 - Developmental Toxins (>0.0%): To the best of our knowledge, there are no chemicals at levels which require reporting under this statute.
Proposition 65 - Female Repro Toxins (>0.0%): To the best of our knowledge, there are no chemicals at levels which require reporting under this statute.
Proposition 65 - Male Repro Toxins (>0.0%):
To the best of our knowledge, there are no chemicals at levels which require reporting under this statute.
New Jersey RTK Substances (>1%):
DIPROPYLENE GLYCOL MONOMETHYL ETHER
Pennsylvania RTK Substances (>1%):
16. Other information
The information and recommendations contained herein are based upon data believed to be correct. However, no guarantee or warranty of any kind, expressed or implied, is made with respect to the information contained herein. We accept no responsibility and disclaim all liability for any harmful effects which may be caused by exposure to our products. Customers/users of this product must comply with all applicable health and safety laws, regulations, and orders.
This is the first version in the GHS SDS format. Listings of changes from previous versions in other formats are not applicable.
The opinions expressed are those of qualified experts within ComStar International Inc. We believe that the information contained is current as of the date of the Safety Data Sheet. Since the use of this information and of these opinions and the conditions of the use of the product are not within the control of ComStar International Inc., it is the user’s obligation to determine the conditions of safe use of the product.
End of Document
Loading...