Com-Power LIN-115A User Manual

Line Impedance Stabilization Network
LINE
LINE
EQUIPMENT
UNDER
TEST
POWER
SOURCE
EARTH GROUND
LISN
NEUTRAL
NEUTRAL
GROUND
GROUND
LINE 1
NEUTRAL
LINE 1
NEUTRAL
EQUIPMENT
UNDER
TEST
POWER
SOURCE
EARTH GROUND
LISN
LISN
LINE 2
LINE 3
LINE 2
LINE 3
GROUND
GROUND
GROUND
GROUND
Features
Frequency range of 150 kHz to 30 MHz
Fully compliant with CISPR 16-1-2 / ANSI C63.4
“Air-core” inductors to prevent saturation
Built-in Transient Limiter
Individual Calibration Included
Description
The LIN-115A Line Impedance Stabilization Network (LISN) provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LIN-115A is compliant with both CISPR 16-1-2 and ANSI C63.4.
The LISN provides dened stable impedance and isolates the EUT from power source inuences,
thereby providing accurate and repeatable results.
LIN-115A
impedance matching, reduction of out-of-band
emissions and transient protection for your measurement instrument.
All Com-Power LISNs are individually calibrated in compliance with the relevant requirements of
CISPR 16-1-2 and ANSI C63.4. Impedance, Phase, Isolation, and Insertion Loss data is supplied with each unit, along with the calibration certicate.
Typical Connection Diagrams
The LIN-115A includes one pair of single-conductor
Single Phase connection with one set of LISN
networks, housed together, to be installed in series
with each current-carrying conductor in a single-
phase, dual-phase or DC power system. A second
LIN-115A pair can be used to accommodate 3-phase
power systems (Wye or Delta congurations).
The LIN-115A is equipped with IEC connector at the mains (power input) and NEMA 5-15R at EUT (power output) ports.
Three Phase connection with two sets of LISNs
This LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plate of the LIN-115A is left unpainted in order to facilitate connection to earth ground in its
installation, which is essential due to high leakage
current.
The LIN-115A has a built in transient limiter for
Com-Power Corporation 19121 El Toro Rd., Silverado, California 92676 (949) 459 - 9600 www.com-power.com
Rev. D04.14
Line Impedance Stabilization Network
LIN-115A
Application
Product Name Line Impedance Stabilization Network (LISN)
Specication CISPR 16-1-2 / ANSI C63.4
Application Frequency Range RF Connector Current Rating Voltage Rating
Inductors
Mains & EUT Connections
Dimensions (each network)
Power line conducted emissions tests
150 kHz to 30 MHz
50Ω N-type (female)
15 Amperes
270 VAC (Line to Ground), 380 VDC
50 µH (air-core)
IEC 60320 @Mains and NEMA 5-15R @EUT
15 x 14 x 7 inches / 38 x 35.5 x 17.8 cm
Weight (each network) 21 lbs / 9.5 kg
Insertion Loss
Isolation
All specications are subject to change without notice. All values are typical, unless specied.
70
60
50
40
Impedance (ohm)
30
20
0.1 1 10 100
< 0.5 dB (150 kHz to 30 MHz)
> 40 dB (150 kHz to 30 MHz)
Frequency (MHz)
, 10 Amperes
(AC)
(DC)
LISN Model No. LIN-115A
CISPR 16-1-2, Ed.1.2, Tbl 4 (50uH) Impedance Limits (±20%)
ANSI C63.4-2009, Tbl B.2 (50uH) Impedance Limits (±20%)
ANSI C63.4-2003, Fig.1 (50uH) Impedance Limits (±20%)
70
60
50
40
30
20
10
Phase Angle (degree)
0
-10
-20
0.1 1 10 100
Com-Power Corporation 19121 El Toro Rd., Silverado, California 92676 (949) 459 - 9600 www.com-power.com
Frequency (MHz)
LISN Model No. LIN-115A
CISPR 16-1-2, Ed.1.2, Tbl 4 (50uH) Phase Limits (±11.5°)
Rev. D04.14
Loading...