Com-Power CDN-M125E User Manual

Features
Frequency Range 150 MHz to 230 MHz
Designed for IEC / EN 61000-4-6
Single conductor power cable
Individual Calibration Included
Three Year Warranty
Coupling Decoupling Network
CDN-M125E
Description
Com-Power CDN-M125E is a part of the series of
Coupling/Decoupling Networks designed specically
for testing product for conducted immunity per IEC/EN 61000-4-6.
The CDN-M125E is designed for testing products that uses a single conductor power cable. It has one 4 mm shrouded banana socket for both EUT and AE power connections. The CDN-M125E can handle up to 25 Amps AC and 17 Amps DC of current.
The RF disturbance signal coupling port is female BNC. It can handle up to 40V of RF input Voltage. The bottom surface of the CDN is not painted for
easy and eective grounding.
All Com-Power CDNs are individually calibrated. The Com-Power CDN-M125E fully complies with the requirement contained in the IEC 61000-4-6 and CISPR 16-1-2.
Application
Before you begin testing with the CDN-M125E you will need to establish calibrated drive levels corresponding to your desired test levels. During drive level calibration, the RF signal level being injected to the CDN is adjusted incrementally until
the voltage level measured at the 150Ω to 50Ω
adapter (ADA-515-2) connected to the EUT port is approximately equal to the Umr value given in the table below. The ADA-515-2 and accessories needed for this test are available from Com-Power.
All Com-Power CDNs can be purchased separately or as part of the CIS series conducted immunity test system. This is a pre-packaged solution that includes
an ACS series power amplier and all accessories
required for the test.
Umr= Voltage level measured at the output of the 150Ω to 50Ω
adapter (ADA-515-2)
Com-Power Corporation 19121 El Toro Road, Silverado, California 92676 (949) 459 - 9600 www.com-power.com
Test Levels
Open Circuit Voltage
1 0.167
3 0.5
10 1.67
Umr
Rev. D01.14
Coupling Decoupling Network
Specications
Product Name Coupling Decoupling Network (CDN) Compliant Test Standards IEC / EN 61000-4-6 Application Single conductor power cable Frequency Range 150 kHz to 230 MHz RF Input Voltage 40V (Max) RF Input Connector 50Ω BNC (Female) Voltage Rating 250 VAC / 350 VDC (Line to Ground) Current Rating 25 Amps AC / 17 Amps DC (Max) AE and EUT Connections 4 mm shrouded banana sockets Common Mode Impedance 150 kHz - 26 MHz: 150Ω ± 20Ω
26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω
Voltage Division Factor 9.5 dB +4 / -1
CDN-M125E
Shorting Adapter Set ADA-M125E
Decoupling of Common
≥ 40 dB (EUT/AE)
Mode Disturbance Dimensions 6 x 6 x 13 inches
15.2 x 15.2 x 33 cm
Weight 5 lbs.
2.3 kg
Accessories Available from Com-Power for setting test levels and running the test
ADA-M125E shorting adapters
ADA-515-2 150Ω to 50Ω adapters TEP-050 50Ω Terminator 1, 3, 6, 10, 20, 30 dB Power Attenuators
Directional Coupler
ACS series Power Ampliers
All values are typical values unless otherwise specied. Specications are subject to change without notice.
Typical data
Impedance
230
210
190
170
150
130
Impedance (Ω)
110
90
70
50
0 1 10 100 1000
Frequency (MHz)
ADA-515-2 Adapter Set
TEP-050 Terminator
Phase
25
20
15
10
5
0
-5
Angle (degrees)
-10
-15
-20
-25 0 1 10 100
Frequency (MHz)
Rev. D01.14
Com-Power Corporation 19121 El Toro Road, Silverado, California 92676 (949) 459 - 9600 www.com-power.com