Component Hardware K16 - 9000 - M, K16-0100 User Manual

SPECIFIER ITEM NO. ________________
®
CHG PART NO. _______________________
Encore® Deck Mount Electronic Faucet with Temperature Control, AC
K16 - 9000 - M
ENGINEERING SPECIFICATION:
Shall be single-hole deck mount, mixing, automatic, lavatory faucet with chrome plated, solid, all metal construction. Included faucet, sensor assembly, 6V DC slow-closing solenoid valve, plug-in power adapter, armored/vandal resistant faucet input power cable, two (2)
3/8” braided S.S. supply lines, two (2) in-line lters, 0.5 GPM
ADA
vandal resistant aerator and all necessary faucet mounting hardware. Features include: All major faucet components (sensor, control module (PCB) and solenoid valve) are housed in an innovative, vandal resistant, clam-shell designed faucet body for easy, above the deck, access and quick installation. Installation of the furnished, external temperature control lever assembly will allow the user to externally adjust the water temperature and perform manual ON/OFF. If external temperature control lever
is not installed, water temperature may be xed from “above the
deck”. Unique mounting of self-adapting sensor resolves all
potential reectivity issues.
TECHNICAL/PERFORMANCE SPECIFICATIONS:
Commercial Specication Grade
Operating Temperature: 40 - 140°F Operating Pressure: 5 - 125psi 3/8” Compression female inlet Vandal resistant housing hardware
In-line check valve w/cleanable lter included
Black plastic trim ring included Self-Adapting Sensor Distance Adjustment 30 Second time-out feature 1 Second shut-off delay 120VAC 50/60 Hz input-7.5VDC 0.8A/Class 2 UL/CSA transformer 1 1/4” mounting hole required Above the deck Temperature mixing control
1890 Swarthmore Avenue, PO Box 2020, Lakewood, New Jersey 08701 Phone: 800-526-3694, 732-363-4700, Fax: 732-364-8110
www.chgusa.com
®
4 7/8 [124]
1 [25]
MAXIMUM DECK
THICKNESS
4 1/2 [114]
TRANSFORMER
IN LINE FILT ERS
24 [610]
5 1/8 [131]
6 1/4 [159]
Dimensions shown in inches (mm) are for reference only and are subject to change.
OPTIONS:
K16-0100 Multi-unit voltage adapter for multiple units K16-0004 4” Cover plate for vandal resistant three point anchoring K16-0008 8” Cover plate for vandal resistant three point anchoring
Aerators:
KN50-X203-A 0.5 GPM PCA spray vandal proof KN50-X203-F 1.5 GPM max. laminar vandal proof KN50-X121-A 0.5 GPM PCA spray KN50-X121-F 1.5 GPM max. laminar KN50-X121 2.2 GPM max. aerated stream
1890 Swarthmore Avenue, PO Box 2020, Lakewood, New Jersey 08701 Phone: 800-526-3694, 732-363-4700, Fax: 732-364-8110
www.chgusa.com