Compex Technologies 400 User Manual

HIGHFLOW 400 ELECTRONIC
SERIES
USER INSTRUCTIONS &
CUSTOMER CARE GUIDE
G.C. NUMBERS
APPLIANCE NATURAL GAS L.P.G.
Fanned Flue (RSF) 47 311 61 47 311 64
Open Flue (OF) 47 311 63
EXCELLENCE COMES AS STANDARD
Thank you for purchasing a Highflow 400 Electronic
gas-fired combination appliance.
Highflow 400 Electronic Series appliances are made by Worcester Heat Systems and the strictest quality control stan­dards are demanded throughout every stage of production.
Indeed, Worcester Heat Systems have led the field in inno-
vative appliance design and performance for more than 30
years.
The result is that your new Highflow 400 Electronic appliance offers you the very best of every­thing - quality, efficiency, economical running costs, proven reliability and value for money.
What’s more, you also have the assur­ance of our no-nonsense 1 year parts and labour guar­antee.
And it’s backed up by Worcester Care Call - a complete maintenance scheme to keep your boiler operating at peak condition and efficiency.
No wonder that more and more people are agreeing that when it is gas, it has to be Worcester Highflow 400 Electronic Series.
Page No.
Operating Instructions
.................................... 3-11
Fault and Breakdowns 12
Maintenance and Extended Warranty
Information ............ 13-14
Guarantee Details .. 15-16
CONTENTS
2
GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1998
It is the law that all gas appliances must be installed by a compe­tent person in accordance with the above regulations. Failure to install appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure compliance with the law. The manufacturers notes must not be taken, in any way, as over-riding statutory obligations.
WARNING: This appliance must be earthed and protected by a 3 amp fuse.
ELECTRICITY SUPPLY: 230V ~ 50Hz
IMPORTANT: To get the best from your Highflow please read
these instructions carefully.
NOTE: In the event of a fault the appliance should not be used until the fault has been corrected by a competent person.
GENERAL DESCRIPTION
(See Fig.1.)
The HIGHFLOW 400 ELECTRONIC MODELS are combined domestic hot water and central heating appliances. They consist of a gas fired boiler having a varying output of between 8.8/11 kW and 24 kW, a heatbank containing stored primary water, a heat-exchanger to provide domestic hot water via the boiler, a circulating pump, water diverting valve and all necessary controls to provide central heating and mains fed domestic hot water and central heating.
The hot water delivery rate is limited to 18 l/m. The specific rate, declared as part of the relevant standard, is 20 l/m. To achieve this a tank temperature of 75°C is required.
The appliances can operate in one of three modes. Hot water only or hot water and central heating or heating only.
Hot Water Mode:
When a demand is made for hot water by opening a tap or show­er hot water will be delivered almost immediately. The flow turbine will energise the pump and circulate primary hot water around the boiler and water to water heat exchanger. The burner will light to maintain the temperature of the heatbank.
When hot water is no longer required the appliance will contin­ue to operate, the burner will cycle a number of times, until the heat­bank has returned to temperature. The pump will continue to run for a few minutes to dissipate the residual heat around the appliance.
If no hot water demand is made then the boiler will only use enough energy to maintain the temperature of the heatbank.
The maximum temperature of the water drawn off from the heatbank is governed by the setting of the Hot Water Temperature Control. (See Fig.2.)
A flow restrictor is fitted within the appliance which limits a hot water delivery rate to a maximum of 18 (±15%) litres/minute.
The restrictor is removed by the installer if a cistern feed hot water system is installed.
GENERAL INFORMATION
3
Hot Water and Central Heating Mode:
The appliance will supply heat to the central heating system as required. A demand for hot water at a tap or shower will override the central heating function for the period of the domestic hot water demand.
When domestic hot water is no longer required the burner and pump will continue to operate until the heatbank is back to the required temperature.
The appliance will then return to the central heating state and its normal mode of operation.
Similarly the hot water is occasionally diverted from the central heating system into the heatbank to maintain the stored primary hot water temperature.
NOTE: If in doubt about the use of the controls ask your installer to assist you.
Central Heating Mode:
When a demand is made for heating by the system controls (i.e. a programmer or room thermostat).
The water diverter valve will open, the pump will energise circu­lating primary water around the heating system and the burner will light. The appliance will operate as necessary to maintain the temper­ature of the radiators at the level set by the adjustment of the Heating Temperature Control. (See Fig. 2.)
If the system no longer requires heat to maintain the desired room temperature, the burner will extinguish. The pump will contin-
ue to run for a short period to dissipate the residual heat from the appliance and then switch off.
4
Fig. 1. System Diagram of Highflow 400 Electronic Series.
Primary Water circulation
Water diverter valve
From radiators
Mains cold in
Flow tur-
bine
Domestic hot water out
Expansion vessel
Slot in front cover. (O.F. only)
Pilot obser­vation win­dow.
To radiators
Circulating
pump
Heat
exchanger
Heatbank
Burner
Boiler
5
CENTRAL HEATING SYSTEM
During the first few hours of operation of the central heating system, check that all radiators are being heated at an even rate. Should the upper area of a radiator be at a lower temperature than the base of the radiator, it should be vented by releasing air through the venting screw at the top of each radiator. Make sure your installer shows you how to carry out the operation. Repeated venting will reduce the quantity of water in the system and this must be replen­ished for safe and satisfactory operation of the appliance. Should water leaks be found in the system or excessive venting be required from any radiator, a service engineer should be contacted and the sys­tem corrected.
SEALED HEATING SYSTEM
The appliance can be fitted to a sealed heating system which is pre-pressurised. In this case your installer will advise you on the min­imum and maximum pressure that should be indicated on the pres­sure gauge. See Fig. 3. Check regularly that this pressure is main­tained and contact your installer or maintenance engineer if there is a permanent significant drop in pressure indicated on the gauge. If the system loses pressure it should be re-pressurised as instructed by the installer.
NOTE: Some sealed systems do not require pre-pressurisation. If this type of system has been used by your installer he will advise you of any special maintenance that is required to ensure that the system is always full of water.
Should any water leaks be found in the system or excessive venting be required from any radiator, a service engineer should be contacted and the system corrected.
OPEN VENTED HEATING SYSTEM
The appliance may be fitted to an open vented heating system your installer will advise you. There is no need to check the pressure gauge.
CLEARANCES
Your installer will have provided adequate space around the appliance for safety and servicing. Do not restrict this space by the addition of cupboards, shelves etc. close to the appliance.
Minimum clearances in millimetres.
GENERAL NOTES
BF Models OF Models RSF Models
Left-hand side 5 5 5 Right-hand side 5 70 5 In Front 600 600 600 Above 10 10 10