Compaq StorageWorks 3000 - RAID Array, StorageWorks 3000 Release Note

Page 1
Compaq
Compaq Storageworks
Compaq Compaq
Storageworks
StorageworksStorageworks
RAID Array 3000 for Microsoft Windows
January, 2001
This document summarizes features and characteristics of the RAID Array 3000 operating software Version 1.3 for Windows NT and Windows 2000 systems that are not covered elsewhere in the documentation.
** NOTICE **
Read this entire document before
installing
or upgrading the software.
** NOTICE **
AA–RAD0D-TE Page 1
Page 2
Compaq StorageWorks RAID Array 3000 for Microsoft Windows
© 2001 Compaq Computer Corporation.
COMPAQ, the Compaq logo and StorageWorks Registered with the U.S. Patent and Trademark Office.
Microsoft, MS-DOS, Windows, and Windows NT are trademarks of Microsoft Corporation.
All other product names mentioned herein may be trademarks of their respective companies.
Confidential computer software. Valid license from Compaq required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license.
Compaq shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is subject to change without notice.
THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND. THE ENTIRE RISK ARISING OUT OF THE USE OF THIS INFORMATION REMAINS WITH RECIPIENT. IN NO EVENT SHALL COMPAQ BE LIABLE FOR ANY DIRECT, CONSEQUENTIAL, INCIDENTAL, SPECIAL, PUNITIVE OR OTHER DAMAGES WHATSOEVER (INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION OR LOSS OF BUSINESS INFORMATION), EVEN IF COMPAQ HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND WHETHER IN AN ACTION OF CONTRACT OR TORT, INCLUDING NEGLIGENCE.
The limited warranties for Compaq products are exclusively set forth in the documentation accompanying such products. Nothing herein should be construed as constituting a further or additional warranty.
Compaq StorageWorks RAID Array 3000 for Microsoft Windows Release Notes Part Number AA-RAD0D-TE
Page 2 AA–RAD0D–TE
Page 3
Release Notes
Visit out Web Site for the latest Information
Check our web site for the latest drivers, technical tips and documentation for the RAID Array 3000. We can be found in the technical area of our web page:
http://www.compaq.com/storage
Supported Operating Systems for the RAID Array 3000
You have purchased support for the Windows NT operating system version 4.0 with Service pack 6a and Windows 2000 operating system. The supported host adapter is the SWXA3-BD differential PCI host adapter.
Supported Configurations
Your RAID Array 3000 contains a single dual-ported controller. This allows support for eight SCSI logical units (LUNs) per port, or a total of 16 LUNs per controller. A second controller (DS-HSZ22-AA) can be added for redundancy and performance. The minimum version of controller firmware for both controllers is D11U. The controller firmware contained on the CD-ROM is D11X (in the \firmware directory) that is part of this kit. If the controller is running an earlier revision of firmware (D10I, D11O, D11U, or D11V), you will need to upgrade the firmware prior to making the RAID Array 3000 operational.
You can create a Windows NT boot partition on the RAID Array 3000 storage subsystem. The Windows NT boot partition can be at most 4 GB in size. Ensure that the host adapter is configured to default parameters (BIOS enable, wide negotiation, >1 GB translation).
AA–RAD0D–TE Page 3
Page 4
Compaq StorageWorks RAID Array 3000 for Microsoft Windows
Table 1 lists the minimum system requirements need for the RAID Array 3000.
Table 1 Minimum System Requirements
Host Feature Requirements
Platform X-86 P200 System. 64MB RAM, 10 MB Disk Space Operating System Windows NT 4.0 SP4 ,Windows 2000 for SWCC client; Windows
NT 4.0 SP6a ,Windows 2000 SP1 for SWCC Agent Controller Compatibility The HSZ22 controller running operating firmware, version D11X. Adapter Compatibility DG-SWXA3-BD
The StorageWorks Command Console (SWCC) version 2.2 is the only configuration utility that will work with your RAID Array 3000. Command Console version 2.2 sometimes referred to as Client, runs on Windows NT 4.0 SP4, and Windows 2000.
Required Driver Revisions
HSZDISK
HSZDISK.SYS is a class driver required for all RAID Array 3000 Windows NT configurations. It is designed to enhance the error recovery features built into your Compaq RAID system, and to provide more robust operation than the native Windows NT SCSI disk class driver. HSZDISK.SYS only affects DIGITAL RAID devices. Other SCSI disk drives in your system continue to be serviced by the native SCSIDISK.SYS class driver. The drivers included in the CD-ROM labeled Compaq StorageWorks
RA3000 Solution Software version 1.3 for Windows NT.
automatically determine if you are working in Windows NT 4.0 or Windows 2000.
The install process will
Page 4 AA–RAD0D–TE
Page 5
Release Notes
SCSI Host Adapter Description
The host adapters qualified for use with your StorageWorks RAID Array 3000 for Windows NT is the SWXA3-BD Ultra-Wide Differential SCSI Host Adapter. Table 2 lists the specifications of the qualified host adapter.
Table 2 RAID Array 3000 Qualified Adapter
PCI Adapter BIOS Revision Windows NT version 4.0
Driver
SWXA3-BD 2.11 4.0
Windows 2000
Driver
SWXA3-BD 2.11 5.0.2144.1
Order Information
Table 3 lists the order numbers for the RAID Array 3000 upgrade options and replacement parts.
Table 3 RAID Array 3000 Upgrades and Replacement Parts
Part Number Option Description
DS-HSZ22-AA, AB Second controller option DS-SWXRA-GD Expansion pedestal option 54-23170-BA SIMM Pack for cache memory DS-SWXRA-GR Replacement UPS
Supported Devices
Firmware version D11w or higher supports the devices listed in Table 4 at the indicated hardware and Microcode levels or higher.
AA–RAD0D–TE Page 5
Page 6
Compaq StorageWorks RAID Array 3000 for Microsoft Windows
Table 4 Supported Disk Drives
Part Number Description Minimum Firmware Level
DS–RZ1CF–VW (380691-B21) DS–RZ1DF–VW (380595-B21) DS–RZ1EF–VW (380694-B21) DS–RZ1CD–VW 4.3GB, 10000RPM disk in 3.5” SBB 0306
4.3GB, 7200RPM disk in 3.5” SBB 0371/N1H1/1614
9.1GB, 7200RPM disk in 3.5” SBB 0371/N1H1/1614
18.2GB, 7200RPM disk in 3.5” SBB 0371/N1H1
DS–RZ1DD–VW (380588-B21) DS–RZ1ED–VW (380589-B21) DS–RZ1FC–VW (159138-001) DS–RZ1BB–VW (380695-B21) DS–RZ1CB–VW 4.3 GB, 7200RPM disk in 3.5” SBB LYJ0/0658
DS–RZ1DB–VW (380693—B21) DS–RZ1DA–VW (147597-001) DS–RZ1EA–VW (147598-001) DS–RZ1FB–VW (147599-001)
9.1GB, 10000RPM disk in 3.5” SBB 0306/3B07/3B012/BDC4
18.2GB, 10000RPM disk in 3.5” SBB 0306/3B07/B012/BDC4/3B05
36.4GB, 10000RPM disk in 3.5” SBB 38FA
2.1 GB, 7200RPM disk in 3.5” SBB LYJ0/0658
9.1 GB, 7200RPM disk in 3.5” SBB LYJ0/0658
9.1GB, 7200RPM disk in 3.5” SBB 3B05/B012
18.2GB, 7200RPM disk in 3.5” SBB 3B05
36.4GB, 7200RPM disk in 3.5” SBB 3B05
On-line Documentation
Your RAID Array 3000 reference manuals are part of the RAID Array 3000 version 1.3 for Windows NT CD-ROM. They can be viewed and printed using Adobe Acrobat Reader when installed on an X-86-based Windows platform. A copy of the reader is included in the CD-ROM for your convenience.
Page 6 AA–RAD0D–TE
Page 7
Release Notes
RAID Array 3000 Operating Constraints
Controller
Always operate Your RAID Array 3000 with the UPS-to-Pedestal Serial Cable connected.
The UPS serial cable must be connected at all times. This cable is used to communicate a power failure to the controller. When the controller senses a power failure, it automatically saves your data to disk. The purpose of the UPS is to keep your system running until the controller accomplishes its task of saving cache data to disk.
Wait until the Disk Drive Fault Indicator Clears before using the Disk.
Disk drive fault LED clearing takes approximately two minutes. Do not attempt to use a disk drive until its fault indicator turns off.
AA–RAD0D–TE Page 7
Page 8
Compaq StorageWorks RAID Array 3000 for Microsoft Windows
EMU Warning Conditions
Tables 5 and 6 list the warning conditions presented by SWCC environmental properties page and the RAID Array 3000 controller shelf fault LED, respectively.
Table 5 SWCC/Caution Icon Warning Conditions
Pedestal UPS Temperature Fan Power Supply
Pedestal SWCC/Caution Icon Pedestal Expansion SWCC/Caution Icon Controller Shelf SWCC/Caution Icon Expander Shelf SWCC/Caution Icon
ON ON ON ON
ON ON ON ON
ON ON No Caution Icon ON
N/A No Caution
Icon
ON (Expansion cabinet is abnormal)
ON (Expansion cabinet is abnormal)
Page 8 AA–RAD0D–TE
Page 9
Release Notes
Table 6 Fault LED Warning Conditions
Pedestal UPS Temperature Fan Power Supply
Pedestal Fault LED ON ON ON ON Pedestal Expansion Fault LED ON ON ON ON Controller Shelf Controller Shelf LED ON ON No Fault Indication ON Expander Shelf Controller Shelf LED N/A ON No Fault Indication ON
AA–RAD0D–TE Page 9
Page 10
Compaq StorageWorks RAID Array 3000 for Microsoft Windows
Changing the RAID Array Configuration
Note
To safe guard critical data backup your system using normal backup procedures before altering device partitions. Do not alter partitions that contain important data.
When making changes to an existing RAID Array configuration, any existing disk partitions to be changed (or removed) must first be deleted using the Windows NT Administrator. After they have been deleted, you may use the StorageWorks RAID Array 3000 Storage Subsystem Command Console Client to create new virtual disks. (Refer to the Command Console User’s Guide and on-line help to make changes).
Page 10 AA–RAD0D–TE
Page 11
Removing Disk Partitions
1. From the Disk Administrator, click the partition you wish to delete.
Release Notes
2. Access the Partition menu and choose
Delete
.
3. Continue selecting and deleting the partitions until you have deleted all the partitions you wish. When finished, click
Commit Changes Now
. You may now reconfigure the StorageWorks RAID Array 3000 Storage Subsystem Array using Command Console Client.
4. Reboot your system so Windows NT will recognize the changes.
Shutdown Procedure
You must issue
shutdown
shutdown
is issued. (When
the cache to the disk drive, then stops blinking).
If a controller requires a rebind, the SCSI bus must be quiesced before performing
this operation. All I/O must be stopped before replacing the failed controller.
Reconnecting the SWCC client may be necessary if any of the following conditions
occur:
1. Controller failover.
2. Lost connection to the subsystem.
3. SWCC does not reflect the correct state of the controllers after a FAILBACK (rebind).
from SWCC. Do
shutdown
is issued from SWCC, the controller first flushes
turn off the system power before
not
4. Deletion of virtual disks and/or RAIDsets.
AA–RAD0D–TE Page 11
Page 12
Compaq StorageWorks RAID Array 3000 for Microsoft Windows
StorageWorks Command Console SWCC
This version of SWCC software is for use with the StorageWorks HSZ22 controllers only. This product CANNOT be used for configuring any other StorageWorks controllers. The following is a list of known issues and limitations of the SWCC Client software:
Initial Configuration – The SWCC Client requires one serial connection for each controller in the RA3000 subsystem for initial configuration. The initial configuration of a dual controller system requires a PC with two serial ports. You must connect each controller to a different communications port on the PC on which the SWCC Client software is running. Check the
for Microsoft Windows Installation Guide
equipped with a single serial port, refer to the
Controller Option Guide
Firmware Download – If you must upgrade the controller firmware, you must
(EK-SM3KC-IG.E01).
connect via the SCSI bus or network. If the boot device is located on the RA3000, refer to the
Read Me File
on the CD-ROM, which explains how to download
firmware using a serial connection.
, AA-RACZD-TE) for details. If the PC is
RAID Array 3000 Subsystem Second
Getting Started RAID Array 3000
Page 12 AA–RAD0D–TE
Loading...