Compaq Netelligent 1108 User Manual

Page 1
Netelligent 1108
100Base-TX Repeater
User Guide
Page 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
iii
The information in this publication is subject to change without notice. COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL OR
EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN, NOR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIAL.
This publication contains information protected by copyright. No part of this publication may be photocopied or reproduced in any form without prior written consent from Compaq Computer Corporation.
The software described in this guide is furnished under a license agreement or non disclosure agreement.
The software may be used or copied only in accordance with the terms of the agreement. Product names mentioned herein may be trademarks and/or registered trademarks of their respective
companies.
1996 Compaq Computer Corporation.
All rights reserved. Printed in the U.S.A.
Compaq
Registered United States Patent and Trademark Office.
Netelligent is a trademark of Compaq Computer Corporation.
Compaq Netelligent 1108 100Base-TX Repeater
User Guide
Second Edition (April 1996)
Part Number 185813-002
Page 3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Federal Communications Commission Notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this manual, may cause interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Class A devices bear a label indicating the interference potential of the device as well as additional operating instructions for the user, such as the following: This device complies with Part 15 of the Federal Communications Commission (FCC) Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
v
Canadian Department of Communications
Radio Frequency Statement
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numriques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministères des Communications du Canada.
Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Compaq Computer Corporation may void the user’s authority to operate the equipment.
Emissions
This equipment complies with EMC directive 89/336/EEC (ITE), which includes EN50081-1 CLASS 1: 1992 (EN55022/CISPR 22 for Class A ITE). It also complies with FCC Class A.
Page 4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vi
European Union Notice
Products with the CE (Community European) Marking comply with both the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community.
Compliance with these directives implies conformity to the following European Norms:
EN55022 (CISPR 22) - Electromagnetic Interference
EN50082-1 (IEC801-2, IEC801-3, IEC801-4) - Electromagnetic Immunity
EN60950 (IEC950) - Product Safety
Safety
This equipment complies with UL 1950, Second Edition; CAN/CSA C22.2 No. 950-93, 73/23/EEC Low Voltage Directive; TUV Rheinland EN60950, 1988; A1/1990, 1993; and A2/1992, 1992, 1993.
Immunity
This equipment complies with EMC directive 89/336/EEC (ITE), which includes EN 50082-1:
IEC 801-2 (Electrostatic Discharge)
IEC 801-3 (Radiated Immunity)
IEC 801-4 (Electrical Fast Transient/Burst)
EN55101-4 (Conducted Immunity) (not currently required)
Netelligent 1108 100Base-T Repeater User Guide
Page 5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vii
Contents
Preface
Intended Reader........................................................................................................ix
Organization of Contents ..........................................................................................ix
Chapter 1
Introduction
Features..................................................................................................................1-1
Hub Components ....................................................................................................1-2
LED Indicators.................................................................................................1-2
RJ-45 Ports.......................................................................................................1-3
Uplink Switch..................................................................................................1-4
Chapter 2
Planning Hub Installation
Before You Begin...................................................................................................2-1
Installation Requirements........................................................................................2-1
Environmental Requirements...........................................................................2-1
Electrical Requirements...................................................................................2-1
Spatial Requirements .......................................................................................2-2
Twisted-Pair (UTP/STP) Wire Requirements...................................................2-3
System Planning Charts ..........................................................................................2-5
Hub Setup and Cabling Chart...........................................................................2-5
Rack Inventory Chart.......................................................................................2-6
Chapter 3
Installing the Hub
Mounting the Hub...................................................................................................3-1
Attaching the Rubber Feet................................................................................3-1
Netelligent 1108 100Base-TX Repeater User Guide
Page 6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
viii
Rack-Mounting the Hub...................................................................................3-1
Connecting Twisted-Pair Cable............................................................................... 3-2
Setting the Uplink Switch .......................................................................................3-3
Interconnecting Hubs..............................................................................................3-4
Connecting Power...................................................................................................3-4
Appendix A
Specifications
Electrical Specifications.........................................................................................A-1
Ports and Connectors.......................................................................................A-1
LED Indicators................................................................................................A-1
Controls ..........................................................................................................A-1
Power Requirements .......................................................................................A-1
Power Consumption........................................................................................A-1
Power Cord (USA)..........................................................................................A-1
Physical Specifications ..........................................................................................A-2
Dimensions.....................................................................................................A-2
Weight............................................................................................................A-2
Environmental Specifications.................................................................................A-2
Operating Environment...................................................................................A-2
Storage Environment.......................................................................................A-2
Glossary Index
Page 7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ix
Preface
This guide includes information about how to install and operate the 100Base­TX Fast Ethernet repeater. We recommend that you read all chapters in this guide to become familiar with all of the repeater's features and to ensure a successful installation.
Intended Reader
This guide is written for network administrators and technicians responsible for hardware instalation.
Organization of Contents
The contents of this guide are organized as follows: Chapter 1 Provides an overview of the 100Base-TX repeater and describes
the repeater's features.
Chapter 2 Helps you plan the installation of the repeater. Chapter 3 Provides instructions for installing and powering up the repeater
and for interconnecting repeaters. Appendix A Includes the repeater's electrical, physical, and environmental
specifications. Glossary Provides terms used throughout this guide, as well as general
networking terms.
Netelligent 1108 100Base-TX Repeater User Guide
Page 8
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 1
Introduction
The Compaq Netelligent 1108 100Base-TX Repeater (Part No. 267022-001) provides a high-speed solution to increasingly heavy network traffic and slow data throughput. The repeater uses the IEEE 802.3u, 100Base-TX standard to increase the speed of network transmissions by a factor of about 10. This enhanced performance greatly improves your network's efficiency.
The repeater has an uplinkable port that lets you connect the repeater to another repeater, providing a maximum of 14 ports on the same collision domain. The repeater also has several LEDs that help you monitor the its status at the repeater and port levels. The repeater provides active management by autopartitioning ports and monitoring error conditions.
1-1
Features
The repeater includes these features:
Eight shielded RJ-45 ports to support UTP (Category 5) or STP cable
Front-panel uplink switch that lets you connect the repeater to another
repeater, providing a maximum of 14 ports on the same collision domain
LEDs that indicate power, repeater activity, and collisions for the
repeater, and link, activity, and partition status for each port.
Transparent active management that autopartitions jabbering ports
Full compatibility with the IEEE 802.3u 100Base-TX repeater
specification
Chassis that can stand alone or be mounted in a standard 19-inch rack
Surface-mount technology
Built-in power supply that operates on a 100 to 240 VAC, 50 to 60 Hz
power source
Netelligent 1108 100Base-TX Repeater User Guide
Page 9
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2 Introduction
Kit Contents
Before you start to install the repeater, verify that this package contains the following items:
1108 100Base-TX Repeater (Part No. 267022-001)
Shielded AC power cord
Compaq Netelligent 1108 100Base-TX Repeater User Guide
Hub Components
This section provides an overview of the repeater's components including the LED indicators, RJ-45 ports, and uplink switch. Figure 1-1 shows the repeater front panel and back panel.
Power/Segmentation/
Activity LED Indicators
RJ-45 Ports and LEDs
12 3 456 7 8
PWR
ACT COL
XXXXXXX
Figure 1-1. Repeater Front Panel
Power Cord Connector
Figure 1-2. Repeater Back Panel
UPLINK
MDIMDI-X
UPLINK Switch (for converting
uplinkable port)
Port 8 to
Page 10
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
LED Indicators
The repeater features several LED indicators that help you monitor the repeater. The LEDs on the left side of the front panel provide the power , activity, and collision status of the repeater. The LEDs above the RJ-45 ports indicate the link, activity, and partition status for each of the ports. Figure 1-2 shows the LED arrangement for the repeater.
RJ45 Port
LED Indicators
12 34 5 6 7 8
PWR
ACT COL
XXXXXXX
Power/Activity/Collision
LED Indicators
UPLINK
MDIMDI-X
1-3
Figure 1-3. LED Indicators
The following information lists the possible conditions, colors, and statuses of each LED and describes the meaning of each condition.
PWR LED Steady green indicates that power is supplied to the
repeater. OFF indicates that no power is supplied to the repeater.
ACT LED Flashing green indicates that there is activity at one or
more of the repeater's ports.
COL LED Flashing yellow indicates that the repeater detects a
collision. OFF indicates that no collisions are occurring.
RJ-45 LEDs Steady green indicates that a link condition is present.
Steady yellow indicates that the port is disabled (autopartitioned). Flashing green indicates that there is activity at the port. Alternately flashing yellow and green indicates that a link condition is present but an error condition, such as a jabber, is being detected. OFF indicates that no link condition is present at the port or there is no connection at the port.
NOTE: LEDs listed as yellow might appear orange on the repeater's front panel.
Netelligent 1108 100Base-TX Repeater User Guide
Page 11
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4 Introduction
RJ-45 Ports
The repeater has eight RJ-45 ports that let you connect UTP or STP cabling to workstations and servers in an Ethernet network.
Uplink Switch
The uplink switch enables the 8th port on the repeater to function as either a standard IN RJ-45 port or an uplinkable OUT” RJ-45 port.
IN ports use an internal crossover of the receive and transmit lines, enabling the port to connect to a network interface card using standard 8-wire UTP cable. OUT” ports use a straight-through (uncrossed) connection, enabling the port to connect to any IN port of a second repeater. This allows two repeaters to be on the same segment.
Standard
"IN" Repeater Port
(Default)
X X
Figure 1-4. Uplink Switch
UPLINK
MDIMDI-X
76
8
UPLINK
MDIMDI-X
Uplinkable
"OUT" Port
Page 12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1
Chapter 2
Planning Hub Installation
This chapter contains information to help you prepare for installing the 100BASE-TX repeater.
Installation Requirements
To help ensure a correct installation, read this section to determine the environmental, electrical, spatial, and cable requirements.
Environmental Requirements
Be sure the operating environment for the repeater is within the following ranges:
Temperature: 32° to 120° F (0° to 49° C)
Humidity: 5% to 95% (non-condensing)
Altitude: 0 to 10,000 feet
Netelligent 1108 100Base-TX Repeater User Guide
Page 13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
-2 Planning Hub Installation
Electrical Requirements
The electrical requirements for a repeater are as follows:
Voltage: 100 to 240 VAC
Frequency: 50 to 60 Hz
Power: 0.25 to 0.5 Amps maximum
CAUTION: The power outlet must be a non-switched, three-pronged, grounded outlet. Do not use a three-to-two pronged adapter at the outlet. Doing so may result in electrical shock and/or damage to the repeater.
NOTE: If the supplied shielded power cord is lost or damaged, replace it with an identical shielded power cord set to ensure emissions compliance.
Spatial Requirements
The repeater's dimensions are 1.75 x 17.00 x 8.5 inches, 4.44 x 43.18 x 21.59 centimeters (HxWxD).
You can interconnect two repeaters. If there is not enough space to mount the repeaters in a single rack or stack them on a single shelf, or if you want to place the repeaters in different locations, you can place them on separate shelves or in separate racks. If this is necessary, you will need longer repeater expansion port cables to connect the repeaters. See the “Twisted-Pair (UTP/STP) Wire Requirements” section in this chapter for more information.
Be sure to allow at least 2 inches (5.1 centimeters) on each side of the repeater for proper air circulation and cable connections.
Twisted-Pair (UTP/STP) Wire Requirements
The twisted-pair wiring you use to connect the repeater's RJ-45 ports must meet the following minimum specifications and requirements to ensure long­term LAN reliability.
Page 14
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3
The wiring must be shielded or unshielded twisted-pair (STP/UTP),
Category 5.
Two pairs of wiring are required.
Depending on building codes, different insulation materials may be
required. Plenum-rated or TEFLON-coated wiring may be required in some areas.
The wire gauge should be between 18 and 26 AWG. (Most telephone
installations use 24-gauge wiring.)
UTP wire should meet the following requirements: Solid copper Nominal capacitance: less than 16 pF/ft Nominal impedance: 100 Ohms Nominal attenuation: less than 11.5 db
CAUTION: Never use gray satin station cable for connecting a repeater. This flat cable, typically used for connecting telephones to wall jacks, is incompatible with 100BASE-TX systems.
Straight-through twisted-pair cable is typically used to connect a repeater to a server or workstation. In a straight-through connection, Pin 1 at the repeater connects to Pin 1 at the server, Pin 2 at the repeater connects to Pin 2 at the server, and so on. Figure 2-1 shows the locations of pins on a standard RJ-45 plug on a twisted-pair cable.
Netelligent 1108 100Base-TX Repeater User Guide
Page 15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
Signal
Description
Signal
Description
-4 Planning Hub Installation
Twisted-Pair Cable
1
2
3
6
RJ-45 Plug
Pins
Figure 2-1. RJ-45 Plug Pin Locations
Table 2-1 shows the wiring in a straight-through and crossover twisted-pair cable. (Pins 4, 5, 7, and 8 are not used.)
Table 2-1
Straight-Through Twisted-Pair Wiring
Twisted Pair Number Pin
Number
11
2
23
6
TD+
TD-
RD+
RD-
To Pin Number Signal
Description
➔ ➔ ➔ ➔
1 2 3 6
TD+
TD-
RD+
RD-
Twisted Pair Number Pin
Crossover Twisted-Pair Wiring
Number
11
2
23
6
TD+
TD-
RD+
RD-
To Pin Number Signal
Description
➔ ➔ ➔ ➔
3 6 1 2
RD+
RD-
TD+
TD-
Page 16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5
System Planning Charts
The charts in Figures 2-2 and 2-3 provide a convenient way of planning the connections for your repeater.
100Base-TX Repeater Setup and Cabling Chart
Date
Unit Number Building Location
Rack Mount Table Mount
Uplink Switch Setting
MDI-X (default) MDI (uplinkable)
Figure 2-2. Hub Setup and Cabling Chart
Port Connects To
8
7 6
4 5
1 2 3
Netelligent 1108 100Base-TX Repeater User Guide
Page 17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
-6 Planning Hub Installation
Rack Inventory Chart
Use this chart to record the components installed in a particular rack.
Wiring Closet Number Rack Number Installer
Date
Figure 2-3. Rack Inventory Chart
Example
100Base-TX Repeater 100Base-TX Repeater
Page 18
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1
Chapter 3
Installing the Repeater
This chapter explains how to mount the 100Base-TX repeater, attach cables, and interconnect the repeater to a second 100Base-TX repeater.
Mounting the Repeater
You can place the repeater on a level surface (table top or shelf, for example) or mount it in a standard EIA 19-inch rack.
Attaching the Rubber Feet
If you will place the repeater on a table top or shelf, attach the supplied adhesive-backed rubber feet as described in the following steps.
1. Turn the repeater over so that its bottom side faces up.
2. Remove the four rubber feet from their packaging.
3. Peel the protective paper backing off the rubber feet.
4. Then position the feet near the corners of the repeater and press the feet into place.
5. Turn the repeater to its upright position and place it on the mounting surface.
NOTE: Be sure you allow at least 2 inches (5.1 centimeters) on each side of the repeater for proper air flow.
Rack-Mounting the Repeater
To mount the repeater in a rack, you must use the RKIT02 installation kit (not supplied). This kit includes two side mounting brackets and eight screws to secure the brackets. To attach the brackets, position them as shown in Figure 3-1. Then secure the brackets with the screws supplied with the mounting kit.
Netelligent 1108 100Base-TX Repeater User Guide
Page 19
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2 Installing the Hub
Figure 3-1. Attaching the Mounting Brackets
After you attach both mounting brackets, position the bracket slots over the desired holes on the rack (Figure 3-2). Then insert and tighten the mounting screws (not supplied).
12 34 5 6 78
PWR
ACT COL
XXXXXXX
Figure 3-2. Positioning the Repeater in a Rack
Connecting Twisted-Pair Cable
Each RJ-45 port on the repeater can accept a standard 4-wire twisted-pair (UTP or STP) cable that ends with an RJ-45 connector. These ports can support cable lengths up to 100 meters (328 feet).
To attach twisted-pair cable, plug one of the RJ-45 connectors into the selected port on the repeater. Connect the other RJ-45 connector into a 100Base-TX-equipped workstation.
UPLINK
MDIMDI-X
Page 20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3
100Base-TX Repeater
1 2 3 4 5 6 7 8
PWR
ACT COL
XXXXXXX
UPLINK
MDIMDI-X
100Base-TX-Equipped
Workstation
Figure 3-3. Connecting Twisted-Pair Cable
Netelligent 1108 100Base-TX Repeater User Guide
Page 21
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4 Installing the Hub
Setting the Uplink Switch
The uplink switch lets you convert the repeater's 8th RJ-45 port to an uplinkable port so that you can interconnect two repeaters without the need for special crossover cables. The default setting for the switch is MDI-X (Media Dependent Interface-Reversed that is, standard repeater port). To convert Port 8 to an uplinkable port, use a small, slotted screwdriver, or a similar tool, to set the switch to the MDI position.
Standard
"IN" Repeater Port
(Default)
76
X X
Figure 3-4. Uplink Switch (Default Setting)
Interconnecting Repeaters
You can interconnect two repeaters, providing up to 14 ports in the same collision domain (Segment).
To interconnect two repeaters, set the uplink switch as described in “Setting the Uplink Switch” in the previous section and connect the repeaters as shown in Figure 3-5.
UPLINK
8
UPLINK
MDIMDI-X
MDIMDI-X
Uplinkable
"OUT" Port
NOTE: The maximum recommended cable distance between two repeaters is 25 meters (82 feet). Exceeding this limit provides unreliable results.
Page 22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5
12 34 5 6 7 8
PWR
ACT COL
XXXXXXX
12 34 5 6 7 8
PWR
ACT COL
XXXXXXX
UPLINK
MDIMDI-X
UPLINK
MDIMDI-X
UPLINK
UPLINK Switch
Set to MDI Position
MDIMDI-X
Figure 3-5. Interconnecting 100Base-TX Repeaters (Set to MDI Position)
Connecting Power
Follow these steps to connect the repeater to power:
WARNING: The repeater has no power switch. Plugging in the power cord powers up the repeater.
1. Plug the power cord into the power connector on the back of the repeater.
2. Insert the three-pronged plug on the power cord into a non-switched, grounded power outlet on a wall, a power strip, or a grounded extension cord.
NOTE: The power outlet should be near the repeater and easily accessible.
Netelligent 1108 100Base-TX Repeater User Guide
Page 23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-6 Installing the Hub
Power Cord Connector
Figure 3-6. Connecting the Power Cord
When you plug in the power cable, the PWR LED lights steady green.
Disconnecting Power
To power down the repeater, disconnect the power cord from the outlet. Do not power down the repeater by disconnecting the power cord from the repeater.
Page 24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A-1
Appendix A
Specifications
Electrical Specifications
Ports and Connectors
Eight RJ-45 ports
LED Indicators
Power (PWR), Activity (ACT), and Collision (COL) status
Eight RJ-45 port to indicate link, activity, and partition status
Controls
Two-position (MDI/MDI-X) uplink switch
Power Requirements
Voltage: 100 to 240 VAC
Frequency: 60 to 50 Hz
Power: 0.25 to 0.5 Amps maximum
Power Consumption
Maximum: 16.2 W
Power Cord (USA)
Shielded 1.8 meters (6 feet), 10 Amps
Netelligent 1108 100Base-TX Repeater User Guide
Page 25
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A
-2 Specifications
Physical Specifications
Dimensions
1.75 x 17 x 8.5 inches, 4.44 x 43.18 x 21.59 cm (HxWxD)
Weight
4 pounds (1.81 kg)
Environmental Specifications
Operating Environment
32° to 120° F (0° to 49° C)
5% to 95% humidity (non-condensing)
Storage Environment
32° to 151° F (0° to 66° C)
5% to 95% humidity (non-condensing)
0 to 30,000 feet altitude (0 to 9 kilometers)
Page 26
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G-1
Glossary
10Base-T
An IEEE standard (802.3) for unshielded twisted-pair (UTP) wiring. Stations are connected using a star topology. The maximum segment length is 100 meters.
100BASE-TX
An IEEE standard (802.3u) for high-speed Ethernet.
802.2
An IEEE standard that governs Logical Link Control (LLC). The LLC layer can provide either connections-oriented services, connectionless services, or a combination of both.
802.3
An IEEE standard that governs Carrier Sense Multiple Access/Collision Detect (CSMA/CD) networks. 802.3, referred to as Ethernet, operates on different cable types (for example, UTP, coax, fiber).
adapter
See NIC.
AUI (attachment unit interface)
See transceiver cable.
backplane
The data bus connections used to interconnect different communication modules inside a networking concentrator.
Netelligent 1108 100Base-TX Repeater User Guide
Page 27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G-2
bridge
A program running on a computer connecting two LANs that allows traffic from one network to be exchanged with the other network. The networks can be the same or different (for example, Ethernet and Token Ring).
carrier sense
The monitoring of a local area network by a node to determine if another node is transmitting.
Class 1 LED
See LED.
coax, coaxial cable
A type of shielded cable used in communication networks. Different types of coaxial cable include Ethernet and RG-6.
collision
Simultaneous transmission on the communication media.
concentrator
A device that houses other repeaters and modules, to provide connectivity between data terminals in a network.
configuration
The layout of nodes and components in the network.
Page 28
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G-3
cross connect
A panel on which the leads of station cable are mounted so that a technician, other wiring craftsperson, or the system administrator can make electrical connections between the communications devices wired to the cables.
dielectric
A substance that does not conduct electrical current.
Electronic Industry Association (EIA)
Ethernet II
Ethernet II or DIX was defined by Digital, Intel, and Xerox. The frame format for Ethernet II differs from that of 802.3 in that the header specifies a packet type instead of the packet length.
Fiber Distributed Data Interface (FDDI)
A high-speed networking standard. The underlying medium is fiber optics, and the topology is a dual-attached, counter-rotating token ring.
hot-swappable
Refers to the ability of a module, switch, or repeater to be added or removed from a stack without removing power from the switch or repeater.
jabbering
Continuous transmission from a node, generally as a result of a hardware or firmware failure.
Netelligent 1108 100Base-TX Repeater User Guide
Page 29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G-4
Local Area Network (LAN)
A communication system which covers a limited geographical area, as distinguished from a Wide Area Network which spans a wide geographical area.
Light Emitting Diode (LED)
A device that emits light at a power level well within guidelines for eye safety. LEDs are typically used to indicate the operating status of a repeater or module.
Link Test
A test that is performed by the hardware to ensure the integrity of the cable. The link test can be disabled to allow old style NICs incapable of performing a link test to connect to the repeater.
modular cord
A cord containing four twisted pairs of wires, with a modular plug on one or both ends.
module
The component that provides connectivity ports for the LAN. Modules are installed in larger systems, called concentrators.
Network Interface Card (NIC)
A card which plugs into a device and allows it to be connected to a network.
node
A device that is attached to a network and communicates by means of the network. Any network station
Page 30
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G-5
partition
The electrical disconnecting of a node from a LAN at its point of connection to a repeater. The node remains physically attached.
Protocol Data Unit (PDU)
A packet that contains control information and optional data.
plenum cord
Communications cord with fire-retardant insulation, generally used in suspended ceilings and other places where air circulates back to the building's air-conditioning system.
Port
An external connector used to connect PCs and other node devices to the network.
repeater
A device that provides connectivity between data terminal equipment. Localizes the connections for multiple network nodes. A repeater is sometimes called a concentrator.
RS-232
Recommended standard 232 defines a standard way of transferring serial information by wire using single-ended line drivers and receivers. RS-232 lines generally include transmit, receive, ground, and various control lines.
RS-485
Recommended standard 485 defines a standard way of transferring serial information by wire using differential line drivers and receivers.
Netelligent 1108 100Base-TX Repeater User Guide
Page 31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G-6
RJ-45
A connector used for 10Base-T wiring (unshielded twisted-pair Ethernet).
router
A device used to connect two or more networks at the Network layer of the ISO-OSI reference model. The router must understand the communication protocols being used because it uses information provided by the protocols in each packet to determine how to route the packets.
segmentation
Segmentation is the process of dividing a network into multiple collision domains.
stack
A stack is a group of interconnected repeaters.
10Base-T
IEEE 802.3 standard for twisted-pair Ethernet. 10 Mb/s over baseband using unshielded, twisted-pair cable.
Telco
A 25-pair polarized connector that is used to consolidate multiple voice or data lines.
Page 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G-7
twisted pair wire
Two insulated copper wires twisted together. The twists vary in length to reduce the potential for signal interference between pairs. In cables greater than 25 pairs, the twisted pairs are grouped and bound together in a common cable sheath. Twisted pair cable is the most common of transmission media.
Unshielded Twisted Pair (UTP)
Cable usually connected using RJ-45 connectors
wiring environment
Any building communications wiring system. See also 66-type wiring environment.
wiring closet
A room, closet, or cabinet where station cable is terminated on crossconnect blocks and where the building communications system can be administered.
Netelligent 1108 100Base-TX Repeater User Guide
Page 33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I-1
Index
1
100Base-TX 1-1, 1-2, 2-1, 2-3, 3-2
A
Activity LED 1-3 Air circulation 2-2 Altitude ranges 2-1
B
Back panel 1-2
C
Cable, crossover 2-4 Chart, rack inventory 2-6 Collision domain 3-4 Collision status LED 1-3 Components 1-2 Crossover 1-4
D
Dimensions 2-2
F
Features 1-1 Frequency 2-2 Front panel 1-2
H
Humidity ranges 2-1
I
IEEE 802.3u 1-1 IN ports
definition 1-4
Installation 3-1
planning 2-1
Interconnecting repeaters 3-4
L
LEDs 1-1, 1-2
ACT 1-3 COL 1-3 PWR 1-3, 3-6 RJ-45 1-3
M
MDI 3-4 MDI-X 3-4 Mounting 3-1 Mounting brackets, attaching 3-2
N
Network interface card 1-4
O
OUT 1-4
P
Planning charts 2-5 Ports
RJ-45 1-1
Power 1-3, 2-2
connecting 3-5 cord 2-2, 3-5 disconnecting 3-6 outlet 2-2, 3-5
Netelligent 1108 100Base-TX Repeater User Guide
Page 34
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-2 Index
requirements 2-2
Power LED 1-3
R
Rack-mounting repeater 3-1 Requirements
electrical 2-1 environmental 2-1
spatial 2-2 RJ-45 1-1 RJ-45 ports 1-2–1-4, 1-2 RKIT02 3-1 Rubber feet, attaching 3-1
S
Segment 1-4, 3-4 STP 1-1, 1-4, 2-3, 3-2 Straight-through (uncrossed)
connection 1-4
W
Wiring
crossover 2-4 guage 2-3 straight-through 2-4
T
Temperature ranges 2-1 Twisted-pair
connecting 3-2
specifications 2-3
U
Uplink switch 1-4
setting 3-4 UTP 1-1, 1-4, 2-3, 3-2
V
Voltage 2-2