• ProLiant 4500 Server system processor options are not compatible with the ProLiant
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5000 Server
• ProLiant 4500 Server memory options are not compatible with the ProLiant 5000 Server
• System Configuration, Diagnostics, and Windows NT SSD require updates
• SMART Controller and NetFlex-3/E Controller can be upgraded to PCI for optimum
performance but are compatible
The HAL compatibility is a significant issue; the server cannot initialize without it. Because HAL
compatibility is an issue in all of the migration scenarios in this document, see the section in this
document called “Step-by-Step Instructions” for more information.
(cont.)
OMPAQ PROLIANT
C
NTFS
3.51
1.16 and Compaq Insight
Management Agents Version
2.61
ABLE
T
5000 S
CENARIO
S
2
ERVER MIGRATION
1
500-MB FAT(boot), 5.5-GB NTFS
Windows NT Server Version 3.51
Windows NT SSD 3.5x, Version 1.18
and Compaq Insight Management
Agents Version 3.00
480A/0197
5
Page 6
W
HITE PAPER
(cont.)
480A/0197
6
Page 7
W
HITE PAPER
.
.
.
.
Processor and memory incompatibility are issues addressed during the planning that occurs before
.
.
.
a purchase is made. In most cases, there is a plan for the continued use of the old hardware. The
.
.
.
information is provided here to assist with the planning stage.
.
.
.
.
.
While the SMART Controller and NetFlex-3 Controller in this configuration are compatible, they
.
.
.
cannot take advantage of the advanced architecture of the ProLiant 5000 Server. Newer versions
.
.
.
of these controllers that are designed to take full advantage of the advanced architecture of the
.
.
.
ProLiant 5000 Server are available and should be considered for a future upgrade.
.
.
.
.
As indicated in the check list, driver upgrades are not necessary for the SMART Controller and
.
.
.
NetFlex-3 Controller to function in the new configuration. All of the drivers and HALs to support
.
.
.
the hardware are located on the Windows NT SSD. To achieve HAL compatibility you must
.
.
.
upgrade to the Windows NT SSD, version 1.18 or later. Update all of the drivers and the HAL
.
.
.
automatically by using the Express Setup option on the Windows NT SSD, version 1.18 or later.
.
.
.
.
.
The ProLiant 5000 Server requires updated versions of the System Configuration and Diagnostics
.
.
.
utilities that are located on the system partition of the boot disk. The version of the Compaq
.
.
.
Support Software CD that ships with your new systems includes the correct versions of these
.
.
.
utilities, as well as the Windows NT SSD, version 1.18 or later. Follow the detailed instructions
.
.
.
for updating the system partition utilities in the “Step-by-Step Instructions” section of this
.
.
.
document.
.
.
.
.
.
.
.
Migration Scenario 2
.
.
.
.
The following migration scenario introduces Microsoft Service Pack 3 for Windows NT Server
.
.
.
3.51, 200-MHz Pentium Pro processors, an upgrade to PCI for the drive array controller, and
.
.
.
.
100TX LAN topology. The remaining items are the same as Migration Scenario 1. This
.
.
.
configuration is better optimized for performance than the configuration illustrated in Migration
.
.
.
Scenario 1.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Hardware and SoftwareProLiant 4500 ServerProLiant 5000 Server
.
.
.
.
System Processor(s)2 X 133-MHz Pentium2 X 200-MHz Pentium Pro
.
.
.
.
.
Memory64 MB (SIMM)64 MB (DIMM)
.
.
.
.
Disk ControllerSMART ControllerSMART-2 /P Controller
.
.
.
.
.
Drive Configuration4 X 2.1 GB (RAID 5)4 X 2.1 GB (RAID 5)
Windows NT SSD, version 1.18 and Compaq
Insight Management Agents, version 3.00 or later
480A/0197
7
Page 8
W
HITE PAPER
.
.
.
.
The following items from the check list in the “Getting Started” section were identified for
.
.
.
consideration in this migration scenario:
.
.
.
.
.
• HAL requires upgrade
.
.
.
.
• SMART-2/P driver upgrade required
.
.
.
.
.
• ProLiant 4500 Server system processor options are not compatible with the ProLiant
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5000 Server
• ProLiant 4500 Server memory options are not compatible with the ProLiant 5000 Server
• System Configuration, Diagnostics, and Windows NT SSD require updates
• NetFlex-3/E Controller can be upgraded to PCI for performance improvement
As with all the configurations in this document, you must upgrade the HAL. Failure to upgrade
the HAL results in a blue screen trap during server initialization. Detailed instructions for
upgrading the HAL are included in the “Step-by-Step Instructions” section of this document.
If you are in the planning stage of a migration, note that the processor and memory options from
the ProLiant 4500 Server are not compatible with the ProLiant 5000 Server.
The device driver for the SMART Controller installed in the ProLiant 4500 Server requires an
update to support the SMART-2/P Controller planned for the ProLiant 5000 Server.
CAUTION:
system to initialize.
Fortunately, this is an easy issue to solve because the updated driver is backward compatible with
the SMART Controller. To resolve this, apply the Windows NT SSD, version 1.18 or greater prior
to moving the controller and drive subsystem to the new platform. Detailed instructions for this
process are included in the “Step-by-Step Instructions” section of this document.
The NetFlex-3/E Controller in this configuration is compatible but does not utilize the highperformance PCI architecture in the ProLiant 5000 Server. To take advantage of the PCI
architecture in the ProLiant 5000 Server, you must install the updated version of this controller.
Even though the existing controller device driver is compatible, you should upgrade it at the same
time as the HAL.
Detailed instructions for updating the system partition utilities (System Configuration,
Diagnostics, Drive Array Configuration, and so on) can be found in the “Step-by-Step
Instructions” section of this document.
(cont.)
You must use the correct driver for the SMART-2/P Controller for the
480A/0197
8
Page 9
W
HITE PAPER
.
.
.
.
.
.
Migration Scenario 3
.
.
.
.
.
The additional processors, Service Pack 4, and additional memory in the following migration
.
.
.
scenario will not require changes to the procedures used to migrate scenario 2 stated earlier.
.
.
.
However, by starting with a SMART-2 /E Controller in the ProLiant 4500 Server you can save the
.
.
.
process of updating the driver before migration.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Hardware and SoftwareProLiant 4500 ServerProLiant 5000 Server
.
.
.
.
System Processor(s)4 X 133-MHz Pentium4 X 166-MHz Pentium Pro
.
.
.
.
.
Memory128 MB (SIMM)128 MB (DIMM)
.
.
.
.
Disk ControllerSMART-2/E ControllerSMART-2/P Controller
.
.
.
.
.
Drive Configuration4 X 2.1 GB (RAID 5)4 X 2.1 GB (RAID 5)
The following items from the checklist in the “Getting Started” section were isolated for
.
.
.
consideration in this migration scenario:
.
.
.
.
.
• HAL update required
.
.
.
.
• ProLiant 4500 Server system processor options are not compatible with the ProLiant
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5000 Server
• ProLiant 4500 Server memory options are not compatible with the ProLiant 5000 Server
• NetFlex-3/E Controller can be upgraded to PCI for performance improvement
• System Configuration, Diagnostics, and Windows NT SSD require update
For this migration scenario, as with migration scenarios 1 and 2, the HAL and system partition
utilities (System Configuration, Diagnostics, and so on) require updates. Procedures for
accomplishing these tasks can be found in the “Step-by-Step Instructions” section of this document.
As is the case with all the migration scenarios presented in this document, the memory and
processor options are not compatible. The Compaq Technology Brief, Configuring the CompaqProLiant 5000 for Peak Performance (document number 301A/0696) provides additional
information on this subject.
The NetFlex-3/E Controller in this configuration is compatible but does not utilize the highperformance PCI architecture in the ProLiant 5000 Server. To take advantage of the PCI
architecture in the ProLiant 5000 Server, you must install the updated version of this controller.
Even though the existing controller device driver is compatible, you should upgrade it at the same
time as the HAL.
(cont.)
OMPAQ PROLIANT
C
Compaq Insight Management
Agents, version 2.61
ABLE
T
5000 S
CENARIO
S
4
ERVER MIGRATION
3
Windows NT SSD, version 1.18 and Compaq
Insight Management Agents, version 3.00 or
later
480A/0197
9
Page 10
W
HITE PAPER
.
.
.
.
.
.
Migration Scenario 4
.
.
.
.
.
The migration scenario that follows takes full advantage of the advanced architecture in the
.
.
.
ProLiant 5000 Server. The table below illustrates the hardware and software components used in
.
.
.
this migration scenario.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Hardware and SoftwareProLiant 4500 ServerProLiant 5000 Server
.
.
.
.
System Processor(s)4 X 133-MHz Pentium4 X 200-MHz Pentium Pro
.
.
.
.
.
Memory128 MB (SIMM)128 MB (DIMM)
.
.
.
.
Disk ControllerSMART ControllerSMART-2/P Controller
.
.
.
.
.
Drive Configuration4 X 2.1 GB (RAID 5)4 X 2.1 GB (RAID 5)
• System Configuration, Diagnostics, and Windows NT SSD require updates
.
.
.
.
.
Carefully follow the HAL upgrade procedures in the “Step-by-Step Instructions” section of this
.
.
.
document. Failure to update the HAL correctly can prevent the system from initializing.
.
.
.
.
The SMART Controller driver from the Windows NT SSD version 1.16 installed in the ProLiant
.
.
.
4500 Server is not compatible with the SMART-2/P Controller planned for the upgraded system.
.
.
.
.
.
.
.
.
.
CAUTION:
.
.
system to initialize.
.
.
.
.
.
.
Apply the Windows NT SSD, version 1.18 or later prior to moving the controller and drive
.
.
.
subsystem to the new platform. Detailed instructions for this process are included in the “Step-by-
.
.
.
Step Instructions” section of this document.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
(cont.)
ABLE
T
OMPAQ PROLIANT
C
CENARIO
S
5.5-GB NTFS
and Compaq Insight Management
Agents, version 2.61
You must use the correct driver for the SMART-2/P Controller for the
5000 S
5
ERVER MIGRATION
4
500-MB FAT(boot),
5.5-GB NTFS
Windows NT SSD, version 1.18 and
Compaq Insight Management Agents,
version 3.00 or later
480A/0197
10
Page 11
W
HITE PAPER
.
.
.
.
.
.
.
The NetFlex-3 Controller configuration information stored in the registry from the ProLiant
.
.
.
.
.
.
4500 Server installation requires replacement when the new NetFlex-3 /P Controller is installed
.
.
.
.
.
.
.
in the ProLiant 5000 Server. Deleting and reinstalling the controller instance is a simple
.
.
.
.
.
.
procedure that resolves this issue. Detailed instructions are available for this procedure in the
.
.
.
.
.
.
“Step-by-Step Instructions” section of this document.
.
.
.
.
.
.
.
.
To update the system partition utilities (System Configuration, Diagnostics, and so on), follow
.
.
.
.
.
.
the detailed instructions in the “Step-by-Step Instructions” section of this document.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
S
TEP-BY-STEP
.
.
.
.
.
.
.
.
.
.
This section provides basic step-by-step instructions for migrating the scenarios described earlier
.
.
.
.
.
.
in this document. Detailed instructions for performing many of the tasks listed in previous
.
.
.
.
.
.
sections, such as updating the HAL, using the system partition utilities, and deleting and
.
.
.
.
.
.
reinstalling a NetFlex-3 Controller instance are also included here.
.
.
.
.
.
.
.
.
.
.
.
.
Step 1: Backup the System
.
.
.
.
.
.
.
.
.
.
You must first perform a complete backup of your system and verify it. Follow the instructions
.
.
.
.
.
.
included with your backup software to enable the Verify After Backup option. This ensures that
.
.
.
.
.
.
you can return to the starting point with all of your data if a problem arises.
.
.
.
.
.
.
.
.
.
.
After the backup is complete, update your Emergency Repair Disk or create a new one. You will
.
.
.
.
.
.
need this if you have to restore your complete system. The Repair Disk Utility accomplishes this
.
.
.
.
.
.
task. Follow these steps:
.
.
.
.
.
.
.
.
1. From a command prompt, type
.
.
.
.
.
.
.
.
.
.
RDISK
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
then press the
2. Select Create Repair Disk to create a new repair disk, or select Update Repair Info to update
an existing repair disk.
3. Follow the instructions given to complete the task.
Step 2: Update the System Partition
Your upgraded system requires an updated version of System Configuration and other utilities
stored in the system partition of your hard disk. To ensure that the correct versions are available to
your new system, follow the instructions below to update the utilities with the version provided
with the new server.
1. Shutdown the server and place the Compaq Software Support CD shipped with your new
server in the CD-ROM drive of your existing server and reboot.
2. Select Upgrade System Partition.
3. Check System Configuration, Diagnostics, Drive Array Configuration, and so on.
4. When the update is complete, select Exit from this utility.
5. Reboot the server.
(cont.)
Enter
INSTRUCTIONS
key.
480A/0197
11
Page 12
W
HITE PAPER
.
.
.
.
.
.
Step 3: Update the Windows NT SSD
.
.
.
.
.
Complete this step while the original system is still functional and before the HAL is updated for
.
.
.
the new system. If you are migrating to the SMART-2 /P Controller, you must use the Windows
.
.
.
NT SSD, version 1.18 or later for the SMART-2 Controller to function properly in the new
.
.
.
system.
.
.
.
.
You can build an updated version of the Windows NT SSD from the Software Support CD
.
.
.
shipped with your new server by following these steps:
.
.
.
.
.
1. Insert the Compaq Support Software CD in the CD-ROM drive.
.
.
.
.
2. Select File
.
.
.
.
.
3. Enter:
.
.
.
.
.
<drive>:\WINDOWS\PB.EXE
.
.
.
.
where <drive> is the drive letter of your CD-ROM drive.
.
.
.
.
.
4. Select Toolbox from the Product Builder Main Menu.
.
.
.
.
5. Select the Microsoft Products category from the Select a Product Category screen.
.
.
.
.
.
6. Select Compaq Support Software for Windows NT from the Select a Product screen.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Information on the products version and space requirements can be viewed on the screen.
7. Select a product, then choose the Build button, or double-click on a product in the list box.
From the Destination and Key Entry screen you can specify the destination drive and
directory for the product.
8. Specify a destination path, then select Continue to begin the copy process.
After you create the latest version of the Windows NT SSD, you must upgrade your system with
all the new drivers. Follow these steps:
1. Insert the Windows NT SSD (Diskette # 1) into the diskette drive.
2. Select File
3. Enter the following:
A:\setup
where A: is the letter of the diskette drive.
4. Select the Express button and then the Update button.
5. Follow the instructions to update all drivers.
6. Remove the Windows NT SSD diskette and restart the computer to enable the drivers.
(cont.)
→
Run from the Windows Program Manager.
→
Run from Program Manager.
480A/0197
12
Page 13
W
HITE PAPER
.
.
.
.
.
.
Step 4: Downgrade the HAL
.
.
.
.
.
The ProLiant 4500 Server requires the Compaq Systempro HAL for multiprocessing in a
.
.
.
Windows NT Server environment and the ProLiant 5000 requires the Compaq MPS HAL. Neither
.
.
.
system initializes without the correct HAL. To facilitate the upgrade, you must install the correct
.
.
.
HAL for the ProLiant 5000 Server while the ProLiant 4500 Server is still functional.
.
.
.
.
The Windows NT SSD detects and installs the appropriate HAL during the installation process.
.
.
.
To accomplish the migration safely, you must downgrade the system to a uniprocessor HAL
.
.
.
and kernel, which can be run on both systems, before moving to the ProLiant 5000 Server.
.
.
.
After successfully migrating all options, you must upgrade the system to a multiprocessor HAL
.
.
.
and kernel.
.
.
.
.
.
The Compaq SSD Setup Utility performs downgrades and upgrades for you. You need the
.
.
.
Windows NT Server and Service Pack media to accomplish the procedure that follows.
.
.
.
.
.
.
.
.
.
CAUTION:
.
.
if the incorrect HAL is installed. Therefore, be careful with your selections.
.
.
.
.
.
.
.
.
With Windows NT Server running on the ProLiant 4500 Server, follow these instructions to
.
.
.
downgrade to a uniprocessor HAL:
.
.
.
.
1. Insert the Windows NT SSD (Diskette # 1) into the diskette drive.
.
.
.
.
.
2. Select File
.
.
.
.
3. Enter the following:
.
.
.
.
.
A:\setup
.
.
.
.
where A: is the letter of the diskette drive.
.
.
.
.
.
4. Select Custom from the Setup Installations Options Menu.
.
.
.
.
5. Select the HAL tab from the Setup - Custom Installation Menu.
.
.
.
.
.
6. Select the Convert to uniprocessor HAL check box.
.
.
.
.
.
7. Insert the Windows NT Server CD in the CD-ROM drive. Select the Downgrade button.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Follow the instructions provided.
NOTE:
Windows NT Service Pack file locations. Be prepared by having these
files ready.
8. Remove the Windows NT SSD diskette and restart the server to enable the new HAL.
To verify that the correct HAL was successfully installed, observe the blue server initialization
screen. A brief message displays to indicate that the Windows NT uniprocessor kernel and the
Compaq uniprocessor HAL are initializing.
The initialization message should indicate that only one system
NOTE:
processor is initializing. This is correct for the uniprocessor configuration,
even though there is more than one processor installed in the system.
(cont.)
If the boot partition is formatted as NTFS, there is no easy recovery
→
Run form Program Manager.
Depending on your configuration, you might be prompted for
480A/0197
13
Page 14
W
HITE PAPER
.
.
.
Step 5: Configure the New System
.
.
.
.
.
To configure the new system, follow these steps:
.
.
.
.
1. Turn off the power to both the new and old systems.
.
.
.
.
.
2. Remove the access covers and prepare to move the drive subsystem and other peripherals to
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
the new system. Because the exact task depends on what options are migrated to the new
system, follow the instructions included with each option that you are migrating.
The following suggestions and warnings might save you some time:
• Take precautions against electrostatic discharge.
• Number the front of the drives before you remove them from the cabinet to make sure
• If you are migrating an array controller to the ProLiant 5000 Server for drives installed in
CAUTION:
the array configuration during migration. Failure to due so can result in the
loss of all data.
3. After all the options are installed, power up the system with the Compaq Support Software
CD in the CD-ROM drive to configure the hardware. If you are migrating a SMART
Controller or a SMART-2 Controller, the system cannot access the system partition of the
hard drive until after the array is configured.
4. For systems with SMART-2 Controllers, you must boot from the Compaq Support Software
CD again and select Configure Drive Array. The SMART-2 Controllers recognize the last
known configuration of the array and list it as the default configuration. Accept the
configuration without change and save it.
CAUTION:
previous configuration results in the loss of all data.
5. After completing the above migration, remove the Compaq Software Support CD and restart
the server to enable the configuration.
Step 6: Reinstall the NetFlex-3 Controller
When changing from a NetFlex-3/E to a NetFlex-3/P Controller, you must delete and reinstall the
controller for it to function properly. For more information on configuring the NetFlex-3/P
Controller, see the Compaq White Paper, Compaq Advanced Network Error Correction Supportin a Microsoft Windows NT Server Environment (document number 353A/0696). After the new
system starts, follow these steps:
1. Select Control Panel
dialog box.
2. Highlight each protocol, select Configure, and write down all configuration details.
(cont.)
they remain in the same order during the migration.
the front hot plug bays of the server, relocate the narrow SCSI cable from the top of the hot
plug drive bay to the narrow SCSI connector on the system I/O board. This is located just
above the wide SCSI cable that is connected to the hot plug drive bays from the factory.
This narrow cable feeds the CD-ROM drive and any tape drive you might have installed.
You must reinstall hot plug drives in the exact order to preserve
Any modification to the array configuration that differs from your
→
Network from the Main program group to start the Network Settings
480A/0197
14
Page 15
W
HITE PAPER
(cont.)
CAUTION:
can result in a network communication failure of the new server.
Failure to record and restore all protocol settings accurately
480A/0197
15
Page 16
W
HITE PAPER
.
.
.
.
3. Select the NetFlex-3 Controller from the Installed Adapter Cards window.
.
.
.
.
4. Select the Remove button and confirm the operation.
.
.
.
.
.
5. Select on Close and then Restart.
.
.
.
.
.
6. Return to the Network Settings dialog box after the server restarts.
.
.
.
.
7. Select Add Adapter.
.
.
.
.
.
8. Select COMPAQ NetFlex-3 EISA/PCI.
.
.
.
.
9. Insert the Windows NT SSD (diskette # 1) in drive A when prompted for the path of the
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
distribution files, and type
a:\net\netflx3 <Enter>
10. The Advanced Network Control Utility automatically runs. Highlight the NetFlex-3
Controller and select the Install button.
11. Select Close and fill in the appropriate protocol information recorded in Step 2.
12. Select Restart System. The system should start and be fully operational.
NOTE: For additional information on configuring the advanced fault tolerance features of
the Advanced Network Control Utility, read the Compaq White Paper, Compaq Advanced
Network Error Correction Support in a Microsoft Windows NT Server Environment.
Step 7: Upgrade the HAL
After the ProLiant 5000 Server is fully configured and you verify that it is functioning properly,
you must upgrade the HAL and kernel to the multiprocessing versions. The Compaq SSD Setup
Utility performs the upgrade to the multiprocessor HAL. You need the Windows NT Server and
Service Pack media to accomplish the procedure that follows.
CAUTION:
if the incorrect HAL is installed. Therefore, be careful with your selections.
With Windows NT Server running on the ProLiant 5000 Server, follow these steps:
1. Insert the Windows NT SSD (Diskette # 1) into the diskette drive.
2. Select File
3. Enter the following:
A:\setup
where A: is the letter of the diskette drive.
4. Select Custom from the Setup Installations Options Menu.
5. Select the HAL tab from the Setup - Custom Installation menu.
6. Select the Upgrade to multiprocessor HAL check box.
(cont.)
If the boot partition is formatted as NTFS, there is no easy recovery
→
Run from Program Manager.
480A/0197
16
Page 17
W
HITE PAPER
.
.
.
.
7. Insert the Windows NT Server CD in the CD-ROM drive. Select the Upgrade button. Follow
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
the instructions provided.
NOTE:
Windows NT Service Pack file locations. Be prepared by having these
files ready.
8. Remove the Windows NT SSD diskette from the drive and restart the server.
To verify that the correct HAL was successfully installed, observe the blue server initialization
screen. A brief message displays to indicate that the Windows NT multiprocessor kernel and the
Compaq multiprocessor HAL are initializing.
Summary
After following the steps outlined in this document, your ProLiant 5000 Server should be fully
configured, with an upgraded HAL and kernel. For more information on installing a new server,
obtaining peak performance from you ProLiant 5000 Server, or increasing network availability,
see the section, “Additional Resources” on page 3.
(cont.)
Depending on your configuration, you might be prompted for
480A/0197
17
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.