COMPANION COMP755D - 55L, COMP875D - 75L, DualZone COMP755D, DualZone COMP875D Instruction Manual

Page 1
Part No. COMP755D - 55L COMP875D - 75L
DUALZONE Freezer/Refrigerator
Instruction Manual
IMPORTANT
Read these instructions for use carefully. Familiarise yourself with the appliance before connecting to either 12/24V DC or 240V AC power. Keep these instructions for future reference.
companionleisure.com.au
MAX
MIN
MAX
MIN
FREEZER
NORMAL SPEED
FAST FREEZE
FRIDGE
3
4
5
1
2
Powered by
Page 2
Installation & operation of your DualZone Freezer/Refrigerator
It is important that your appliance is installed and operated in accordance with the manufacturer’s instructions to guarantee the performance, efciency and operation.
• Position the appliance in a safe & secure location. Limit exposure to heat sources or direct sunlight which can affect the unit’s performance and efciency.
• The normal operation of the appliance requires heat to be radiated away from the condensers located in the end of the cabinet. Adequate airow is required to be available around the compressor at all times.
• The cooling system has been designed to operate correctly when the appliance is positioned on angles up to 35 degrees. It is recommended that the time the unit is exposed to angles over 30 degrees is limited to a maximum of four (4) hours continuous operation.
Important
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• This appliance is suitable for camping use.
• The appliance shall not be exposed to rain.
Power requirements
The DualZone Freezer/Refrigerator is designed to operate on AC & DC voltage inputs.
AC Input – Voltage is required to be 220-240V AC at 50Hz
DC Input – Voltage is required to be 12 or 24V DC +/-10%
The power system is tted with an Automatic Voltage change over program; this will allow for both the AC & DC power cords to be connected to the appliance at the same time. The AC power input has priority and the unit will select this input over DC if both are being provided.
Once the AC power is shut off the appliance will then switch over to DC power. The compressor will not start immediately as the controller will program itself for the change in supply and within 3 minutes the unit will restart using the DC input. This same process will be taken if AC power is resupplied to the appliance.
Defrosting the cabinet
If your appliance is being used solely as a freezer, it is possible that a build up of ice on the interior may occur. This build up can affect the performance & efciency of the cooling system and must be removed.
Do not use solid or sharp utensils such as knives to remove the ice as this may result in damage to the unit. Turn the appliance off and remove the content from the cabinet, allow the ice to melt, then drain the water from the cabinet. Use a soft clean cloth to wipe down all surfaces and allow to dry.
Page 3
Freezer/Refrigerator features
The DualZone Freezer/Refrigerator features two (2) separate compartments, one can be utilised as a freezer or refrigerator and the other section is a refrigerator only. Both compartments are tted with their own thermostat control.
Wire storage baskets are included as standard and each compartment is equipped with plastic covers allowing individual compartments to be accessed without the need to open the other, minimising temperature loss and power consumption.
The refrigerator compartment is cooled by the transfer of cold air from the freezer section via a fan that is tted in the dividing wall. It is important that the wire storage baskets are used at all times in both sections to allow the ow of air into the compartment without obstruction.
Temperature setting
Freezer Section: the temperature range is adjustable
from +8 to -18**. Refrigerator Section: the temperature range is
adjustable from +2 to -5**.
The following temperatures are to be used as a guide only and will be affected by the ambient temperature, contents of the compartments and the number of times that the cabinet is opened.
* At maximum setting the fan will run continuously.
** The temperatures quoted are to be used as a guide
only and are subject to change based on the factors such as ambient temperature, goods being stored, power supply, and access to compartments etc. Temperatures quoted are based on an ambient +32 degrees and an input voltage of 12.7V DC.
The temperature controls are set with a tolerance of +/-3 degrees.
companionleisure.com.au
Freezer Section Fridge Section
Setting Min: +8º Setting Min: +2º
Setting 2: -0º Setting Max*: -5º
Setting 3: -12º
Setting 4: -15º
Setting Max*: -18º
COMPRESSOR ON
Compressor Status: when the LED is illuminated the compressor is running.
Page 4
Battery Cut-out 12/24V DC operation only
The built in battery cut-out system is designed to protect your 12 volt battery source once the available voltage falls to 10.5V DC (12 volt input) and 21.0V DC (24 volt input). Once your battery is recharged and above these cut-out levels the DualZone Freezer/ Refrigerator will operate normally.
Low voltage supply to the appliance can result in poor cooling performance and cause damage to the supply battery.
AC Power Connection
The DualZone Freezer/Refrigerator is supplied with an approved 3 pin AC Power Lead and this must not be modied or lengthened.
When connecting to AC power ensure that the power socket is switched “off”. Plug the AC Power Lead into the AC socket on the appliance and then plug the other end of the AC Power Lead into the AC supply and switch on.
The temperature is adjusted by turning the required control in a clockwise direction for cooler & anti­clockwise for warmer settings. The temperature in each compartment is then displayed on the LCD digital readouts located on the control panel.
The LCD read on the left is for the freezer compartment with the refrigerator compartment read out on the right.
The tolerance for the LCD display is +/- 3 degree.
Normal Speed – Fast Freeze Function
The Fast Freeze function can be used when the cabinet temperature needs to be lowered quickly. By selecting the Fast Freeze function, the speed of the compressor will be increased resulting in quicker pull down times.
Note: When the Freeze function is selected the power draw from the compressor will also increase and therefore increase the power consumption. It is recommended that the Fast Freeze function only be operated for a maximum of 60 minutes per at any one time.
COMPRESSOR ON
Page 5
DC Power Connection
The DualZone Freezer/Refrigerator is supplied with a power cord tted with a cigarette lighter tting. It is recommended that this lead is not lengthened as this may result in a voltage drop and reduced performance.
When connecting the appliance to DC power ensure
that the power socket is switched “off”. Plug the power cord into the DC socket on the appliance and then plug the other end of the power cord into the DC supply and switch on.
For optimum performance & efciency, it is important that the appliance has a reliable 10amp fuse protected DC supply in good condition. Direct connection to the battery is recommended and reduces the risk of voltage dropping to the appliance.
It is recommended that the correct sized Automotive Electrical Cable is used for the direct connection and that this includes a 10amp fuse; do not use resetable circuit breakers. It is important that the correct cable size is used for the installation of the DC supply as over distance the voltage can decrease if the incorrect sized wire is being used.
Distance Wire Gauge
4.5m or less 2.1mm2 (AWG14)
4.6m & over 3.3mm2 (AWG12)
Using Solar Panels
The power consumption & efciency of your DualZone Freezer/Refrigerator makes it ideal to be used in conjunction with solar panels to provide recharging of the DC supply. Solar panels will provide charge into the battery during the daylight hours even while the appliance is operating.
As the output from solar panels change depending on the level of sunlight & intensity, your DualZone Freezer/Refrigerator cannot be connected directly to the solar panels. The appliance must be connected to a suitable DC battery and then the solar panels connected to the battery.
We recommend the use of the Primus range of Portable Solar Panel Kits from 40 to 120 watts for use with your DualZone Freezer/Refrigerator.
companionleisure.com.au
Page 6
Using your DualZone Freezer/Refrigerator – tips & suggestions
• Fresh & frozen foods should not be stored together. The coldness from the frozen goods can be transferred to the other produce causing the goods to spoil. It is best to put an insulating layer between these goods.
• When the appliance is being set at 0 or lower temperatures, do not store glass bottles or liquids such as beer, milk, juices or soft drinks in the unit as these may freeze and shatter.
• Items such as fruit & vegetables should be stored closer to the top of the cabinet as this area is normally slightly warmer. This will reduce the risk of spoiling and ensures that damage is not caused by being crushed by heavier items.
• To improve the efciency of your DualZone Freezer/Refrigerator it is better to have the cabinet as full as possible at all times. A full cabinet will provide lower power consumption over 24 hours than a half empty one. When the cabinet is full there is little air space between the goods so the cold air is trapped, when there is lots of air the coldness cannot be captured and held. On a trip it is a good idea to replace products with bottles of water or similar. This will ll the empty spaces and allow the coldness to remain within the cabinet.
• Make your selection of what you wish to remove from the cabinet before you open the door. This will reduce the time that the cabinet is open and the level of warm air that will enter the cabinet while the door is open.
• When located in the rear of a car or trailer, it is recommended that the appliance be kept away from direct sunlight to reduce the risk of increased heat. It should also be provided with suitable ventilation to guarantee efcient power consumption & performance. You must remember that when a vehicle is parked in the sun that on a day where the ambient temperature is +30º, the interior of the vehicle can reach +55º.
Using Portable Generators
It is important that the correct generator is used with your DualZone Freezer/Refrigerator. An incorrect generator or output may result in reduced performance or damage to your appliance which may void your appliances warranty.
If connecting directly to an AC generator ensure that only a digital or inverter type generator is used. These provide a more reliable & constant 240V AC output and are specically designed to power to electronic and other power sensitive appliances.
We recommend the use of Kipor Digital Inverter generators to provide AC power to your DualZone Freezer/Refrigerator when in remote locations.
Most generators are tted with a DC output - DO NOT connect directly to the DC output of the generator as this will result in damage to your appliance and void any warranty claim.
It is recommended that the appliance remains connected to the DC power source. Then using the DC output of the generator connect this to the battery to recharge it. It is important that you monitor the battery being charged, ensuring that an over supply of charge is not being provided to it causing damage.
Page 7
IDENTIFICATION
1. LCD control panel
2. Carry handle
3. AC socket
4. DC socket
5. Ventilation grill
6. Freezer Compartment
7. Fridge Compartment
8. Compartment lids
companionleisure.com.au
1
8
8
2
6
7
3
4
3
4
5
5
1
COMPRESSOR ON
Page 8
Trouble Shooting
Distributed by
PRIMUS AUSTRALIA Pty Ltd
Bundoora Victoria 3083
www.primusaustralia.com.au
WARRANTY
This appliance is covered against faulty workmanship and materials for a period of 3 years from the date of original purchase.
Customer Service: 1300 555 197
Problem Cause Remedy
The Compressor runs for 1- 5 minutes and stops.
The voltage is insufcient or interrupted.
Switch off power and check connections & fuses then restart.
The compressor runs but inner liner does not get cold.
The voltage is insufcient or interrupted.
Switch off power and check connections & fuses then restart.
Contact your Authorised Service Centre.
The refrigeration system has a fault or is blocked.
The inner liner is very cold and the compressor runs continuously.
The ice layer on the evaporator is too thick.
Defrost.
The door is being opened and closed too frequently.
The door should be opened as little as possible.
The freezer is overloaded. Remove some product.
There is insufcient air ow to the condensor.
Select a well-ventilated place.
The compressor does not run.
“+” and “-” are switched.
Switch off power and check then restart.
The voltage is insufcient or interrupted.
Switch off power and check connections & fuses then restart.
Part No.
COMP755D
Description
55 Litre DualZone Freezer/Refrigerator
Size
690 x 490 x 535mm
Weight
23kg
Part No.
COMP875D
Description
75 Litre DualZone Freezer/Refrigerator
Size
690 x 490 x 625mm
Weight
25kg
COM462
Loading...