Substation-Rated RS-232, RS-422, RS-485 2/4 Wire, & TTL Logic Data
Link/Repeater for Replacement of Garrettcom/Dymec 5800-Series
RLFDX(485,232)(M,S)2/(24DC,48DC,HV) Series
EXCLUSIVE
The ComNet RLFDX series of serial data link/repeaters are substation-rated and industrially
hardened form, fit, function and completely backwards-compatible replacements for the popular
Garrettcom/Dymec 5843, 5844, 5845, and 5846-series of serial data link/repeaters. They are
designed for deployment in environments where high levels of electromagnetic noise and
interference (EMI) and severe voltage transients and surges are routinely encountered, such as
electrical utility substations and switchyards, heavy manufacturing facilities, trackside and roadside
electronic equipment, and other difficult out-of-plant applications. Optical connectivity provides
significantly extended transmission distances compared to copper media; high levels of electrical
isolation; enhanced reliability and protection for peripheral IEDs, RTUs, and other equipment; and
operational safety.
The RLFDX series of serial data link/repeaters are easily field-configurable for point-to-point, pointto-multipoint/master-slave, loop, or bus topologies. They may be also used for electrical data
protocol conversion: an RLFDX232 RS-232 modem and IED/RTU can communicate directly with an
RLFDX485 RS-422/RS-485 modem and IED/RTU.
The extremely versatile and simple-to-install RLFDX series is ideal for any mission-critical application
where very high levels of reliability and network availability are of the utmost importance.
FEATURES
› Fully electrically, mechanically, and optically identical to and
backward-compatible with the Garrettcom/Dymec 5843, 5844,
5845, and 5846 Series. A ComNet RLFDX may directly replace a
Dymec unit anywhere within the network.
› Full-duplex, half-duplex, or simplex transmission of RS-232,
RS-422, RS-485 2/4-wire data, or TTL logic
› Tested and certified to meet or exceed the requirements of
IEEE 1613 Class 2 for electrical utility substations
› RS-232 Version: DTE/DCE switching
› Diagnostic test mode feature tests the copper and optical
connections before the connected IED or RTU is active within
the network.
› Extended ambient operating temperature range of -40º to +85º C,
with no fan/forced air cooling, for use in virtually any environment
› Optical transmission distances of up to 5 km over multimode
fiber; 30 km over single-mode fiber
› +9 to 36 VDC, +/-36 to 59 VDC, or HV AC/DC (+/-88 to 300
VDC/85-264 VAC) operating power options. HV DC input
permits operation directly from station battery bus power.
48 VDC and HV models’ DC inputs are isolated from ground,
allowing operation from positive or negative DC sources.
› Internal/self-contained high-reliability power supply – a screw
terminal block connects directly to the power source for
permanent, reliable, and maintenance-free operation
› LED status indicators confirm operating status
› Rugged galvannealed and powder-coated panel-mount enclosure
CLA SS 1 DIV 2
› IP-30 rated for ingress protection (2.5 mm objects)
› Conformal coating of the circuit boards is optionally available,
for use in humidity with condensation conditions (extra charge,
see ordering information).
Substation-Rated RS-232, RS-422, RS-485 2/4 Wire, & TTL Logic Data
Link/Repeater for Replacement of Garrettcom/Dymec 5800-Series
SPECIFICATIONS (RS232 Models)
Data
Data Rate DC to 250 kbps
Data Transmission Asynchronous, simplex OR Full Duplex
Bit Error Rate 10-E9 Max.
Point to Point Latency 4 μS
Repeat Latency 400 nsec Max.
Fiber Optical Parameters
(At Maximum Operating Temperature)
Optical Budget Typical Multimode: 19.5dB
(62.5 μ/125 Cable @ 3 dB/km)
Single Mode: Up to 30 km
(9 μ/125 Cable @ 0.5 dB/km)
Compatible Fiber Type Multimode: 50-200 μm
Single Mode: 9 to 13 μm
Configuration Switches
DTE/DCE
AC/DC Coupled
Link/Repeat
Pin 8 Drive Current
Pin 6 +5 VDC (DSR or CTS pull up)
Diagnostic Mode
Connectors
Optical ST
Data DB-9 (9 Pin D-Type Female)
Power Removable, 3-pin Screw Terminal Block
Electrical Parameters
Inputs
I/O Data Format EIA RS232; CCITT v.24
Input Impedance >3000 Ω
Input Voltage +/-30 Volts Max.
Outputs
Output Impedance >300 Ω
Driver Output +/- Volts into 3000 Ω
Pin 8 Output 0 to 5 V
67 or 207 Ω Source Impedance
Power Required
24 VDC Multimode: +9 to 36 VDC @ 250 mA (3W)
Single Mode: +9 to 36 VDC @ 340 mA (4.1 W)
48 VDC Multimode: +/-36 to 59 VDC @ 250 mA (4W)
Single Mode: +/-36 to 59 VDC @ 340 mA (5.5 W)
HV Multimode: +/-88 to 300 VDC @ 35 mA (4 W)
or 85 to 264 VAC @ 35 mA (4 W)
Single Mode: +/-88 to 300 VDC @ 50 mA (5.5 W)
or 85 to 264 VAC @ 50mA (5.5 W)
Power Dissipation BTU/H
24 VDC Multimode: 8.2 BTU/hr
Single Mode: 10.2 BTU/hr
HV & 48 VDC Multimode: 10.9 BTU/hr
Single Mode: 12.3 BTU/hr
Mechanical
Indicating LEDs Power Transmit Fiber
Transmit Electrical Receive Fiber
Receive Electrical
Circuit Board Meets IPC Standard
Actual Weight HV & 48 VDC: 1.06 lb / 0.48 kg
24 VDC: 0.56 lb / 0.26 kg
Dimensions (W × L × H)
HV & 48 VDC: 4.1 × 5.1 × 1.3 in (10.41 × 12.95 × 3.3 cm)
24 VDC: 2.0 × 5.1 × 1.3 in (5.08 × 12.95 × 3.3 cm)
Environmental
MTBF >250,000 hours
Operating Temperature Multimode: -40˚C to +85˚C
Single Mode: -40˚C to +70˚C
Storage Temperature -40˚C to 85˚C
Relative Humidity 0% to 95% (non-condensing)¹
ORDERING INFORMATION (RS-232/TTL Models)
ModelData FormatFiber TypeInput PowerEquivalent Dymec Model
RLF DX232M2/24DCRS-232/ TTLMultimode9 to 36 VDC5843HRT
RLFDX232M2/HVRS-232/ TTLMultimode88 to 300 VDC / 85 to 264 VAC5844HRT-H
RLFDX232M2/48DCR S-232/TT LMultimode36 to 59 VDC5844HRT-L
RLFDX232S2/24DCRS-232 /TTLSingle Mode9 to 36 VDC5843SHRT
RLFDX232S2/HVRS-232/ TTLSingle Mode88 to 300 VDC / 85 to 264 VAC5844SHRT-H
RLFDX232S2/48DCRS-232 /TTLSingle Mode36 to 59 VDC5844SHRT-L
Options[1] Add suffix ‘/C’ for Conformally Coated Circuit Boards to extend to condensation conditions (Extra charge, consult f actory)
NOTE: This product requires a fiber installation with a minimum 30 dB connector return loss. The use of Super Polish Connectors is
recommended. Complies with FDA Performance Standard for Laser Products, Title 21, Code of Federal Regulations, Subchapter J
In a continuing effort to improve and advance technology, product specifications are subject to change without notice.
Substation-Rated RS-232, RS-422, RS-485 2/4 Wire, & TTL Logic Data
Link/Repeater for Replacement of Garrettcom/Dymec 5800-Series
SPECIFICATIONS (RS422/485 Models)
Data
Data Rate DC to 2 Mbps
Data Transmission Asynchronous, simplex OR Full Duplex
Bit Error Rate 10-E9 Max.
Point to Point Latency 500 nsec Max.
Repeat Latency 400 nsec Max.
Fiber Optical Parameters
(At Maximum Operating Temperature)
Optical Budget Typical Multimode: 19.5 dB
Optical ST
Data DB-9 (9 Pin D-Type Female)
Power Removable, 3-pin Screw Terminal Block
Electrical Parameters
Inputs
I/O Data Format EIA 422/485
Input Impedance 750 Ω
Input Voltage +12 to -7 Volts Max referenced to signal common
+/-6 Volts differential Max
Outputs
Output Impedance >250 Ω
Driver Output 50 mA
Power Required
24 VDC Multimode: +9 to 36 VDC @ 250 mA (3 W)
Single Mode: +9 to 36 VDC @ 340 mA (4.1 W)
48 VDC Multimode: +/-36 to 59 VDC @ 250 mA (4 W)
Single Mode: +/-36 to 59 VDC @ 340 mA (5.5 W)
HV Multimode: +/-88 to 300 VDC @ 35 mA (4 W)
Indicating LEDs Power Transmit Fiber Transmit Electrical
Receive Fiber Receive Electrical
Circuit Board Meets IPC Standard
Actual Weight HV & 48 VDC: 1.06 lb / 0.48 kg
24 VDC: 0.56 lb / 0.26 kg
Dimensions (W × L × H)
HV & 48 VDC: 4.1 × 5.1 × 1.3 in (10.41 × 12.95 × 3.3 cm)
24 VDC: 2.0 × 5.1 × 1.3 in (5.08 × 12.95 × 3.3 cm)
Environmental
MTBF >250,000 hours
Operating Temperature Multimode: -40˚C to +85˚C
Single Mode: -40˚C to +70˚C
Storage Temperature -40˚C to 85˚C
Relative Humidity 0% to 95% (non-condensing)¹
ORDERING INFORMATION (RS-422/RS-485 Models)
ModelData FormatFiber TypeInput PowerEquivalent Dymec Model
RLFDX485M2/24DCRS- 422/485Multimode9 to 36 VDC5845HRT
RLFDX485M2/HVRS- 422/485Multimode88 to 300 VDC / 85 to 264 VAC5846HRT-H
RLFDX485M2/48DCRS-422/485Multimode36 to 59 VDC5846HRT-L
RLFDX485S2/24DCRS-422/485Single Mode9 to 36 VDC5845SHRT
RLFDX485S2/HVRS- 422/485Single Mode88 to 300 VDC / 85 to 264 VAC5846SHRT-H
RLFDX485S2/48DCRS-422/485Single Mode36 to 59 VDC5846SHRT-L
Options[1] Add suffix ‘/C’ for Conformally Coated Circuit Boards to ex tend to condensation conditions (Extra charge, consult fac tory)
NOTE: This product requires a fiber installation with a minimum 30 dB connector return loss. The use of Super Polish Connectors is
recommended. Complies with FDA Performance Standard for Laser Products, Title 21, Code of Federal Regulations, Subchapter J
In a continuing effort to improve and advance technology, product specifications are subject to change without notice.