Comnet FXA2C1S1B, FXA2C1S1A, FXA2C1M1B, FXA2C1M1A User Manual

INSTALLATION AND OPERATION MANUAL
FTA/FRA2C1(M,S)1 and FXA2C1(M,S)1
2 AUDIO CHANNELS + 1 CONTACT CLOSURE
This manual serves the following ComNet Model Numbers:
FTA 2C1M1 FR A2C1M1 FTA 2C1S1 FR A2C1S1 FXA2C1M1A FXA2C1M1B FXA2C1S1A FXA2C1S1B
The ComNet™ FTA/FRA2C1 Series audio multiplexer provides the transmission of two audio signals and one contact closure over one multimode or single mode optical fiber. A bidirectional model, FXA2C1(M,S)1, is also available. The modules use 24-bit 96kHz sample rate digital encoding for superior transmission of balanced line-level audio. Plug-and-play design ensures ease of installation and no electrical or optical adjustments are required.
These extenders are designed for long-term, reliable operation in harsh industrial environments, and a fault-specific LED indicator is provided for rapidly ascertaining the operating status of the extender and the link. See Figure 9 on Page 5 for an explanation of LED indicators.
Packaged in the exclusive ComNet ComFit housing, these units may be either wall or rack mounted. See Figure A on Page 6 for mounting instructions.
See Figures 1 – 9 for complete installation details.
INS_F(T,R)A2C1(M,S)1_FXA2C1(M,S)1_REV– 04/25/12 PAGE 1
INSTALLATION AND OPERATION MANUAL FTA/FRA2C1(M,S)1 AND FXA2C1(M,S)1
FIGURE 1 – FTA2C1 TRANSMITTER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK BLACK WITH WHITE STRIPE/RED
FIGURE 2 – FTA2C1 TRANSMITTER
REAR PANELFRONT PANEL
Power Supply: 8-15VDC @ 2W
Note: Remove Electrical Connector for Rack Mount Units
INS_F(T,R)A2C1(M,S)1_FXA2C1(M,S)1_REV– 04/25/12 PAGE 2Tech SupporT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL FTA/FRA2C1(M,S)1 AND FXA2C1(M,S)1
FIGURE 3 – FRA2C1 RECEIvER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK BLACK WITH WHITE STRIPE/RED
FIGURE 4 – FRA2C1 RECEIvER
REAR PANELFRONT PANEL
Power Supply: 8-15VDC @ 2W
Note: Remove Electrical Connector for Rack Mount Units
INS_F(T,R)A2C1(M,S)1_FXA2C1(M,S)1_REV– 04/25/12 PAGE 3Tech SupporT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL FTA/FRA2C1(M,S)1 AND FXA2C1(M,S)1
n
n
FIGURE 5 – FXA2C1 TRANSCEIvER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK BLACK WITH WHITE STRIPE/RED
FIGURE 6 – FXA2C1 TRANSCEIvER
REAR PANELFRONT PANEL
Power Supply: 8-15VDC @ 2W
Note: Remove Electrical Connector for Rack Mount Units
n
INS_F(T,R)A2C1(M,S)1_FXA2C1(M,S)1_REV– 04/25/12 PAGE 4Tech SupporT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL FTA/FRA2C1(M,S)1 AND FXA2C1(M,S)1
INSTALLATION AND OPERATION MANUAL FTA/FRA2C1(M,S)1 AND FXA2C1(M,S)1
FIGURE 7 – AUDIO WIRING
Wiring panel terminal block is located on the back panel of each unit.
Channel 2 Signal In from Customer Equipment
Channel 1 Signal In from Customer Equipment
Audio Input (Receiver/Transceiver)
Audio Output (Transmitter/Transceiver)
FIGURE 8 – CONTACT WIRING
Wiring panel terminal block is located on the back panel of each unit.
Channel 2 Signal Out to Customer Equipment
Channel 1 Signal Out to Customer Equipment
Contact Closure Output
Contact Out (Receiver/Transceiver)
FIGURE 9 – LED INDICATORS
LINK AUDIO CONTACT
Communication link has
RED
GRN
OFF Unit powered down
not been established over
fiber
Communication link has
been established over
fiber
_ _
LED intensity varies with
audio signal level of either
channel input
Low or no audio input
level
Contact Closure Input (Dry Contacts Only)
Contact In (Transmitter/Transceiver)
IN OUT IN OUT
LED intensity varies with
audio signal level of either
channel output
Low or no audio outnput
level
Contact closure input is
open
Contact closure input is
closed
Unit powered down
Contact closure output
is open
Contact closure output is
closed
INS_F(T,R)A2C1(M,S)1_FXA2C1(M,S)1_REV– 04/25/12 PAGE 5Tech SupporT: 1.888.678.9427
MECHANICAL INSTALLATION INSTRUCTIONS FTA/FRA2C1(M,S)1 AND FXA2C1(M,S)1
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 power supply.
FIGURE A
Dimensions are for a standard ComNet™ one slot module.
.156 [3.96 mm]
.313 [7.95 mm]
IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should
be such that the amount of air flow required for safe operation of the equipment is not compromised.
3 Corporate Drive | Danbury, Ct 06810 | uSa t: 203.796.5300 | F: 203.796.5303 | teCh Support: 1.888.678.9427 | inFo@Comnet.net