Comnet FVTR1D1A2C1M1, FVTR1D1A2C1 1 Series, FVTR1D1A2C1S1 Installation And Operation Manual

Page 1
INSTALLATION AND OPERATION MANUAL
FVTR1D1A2C1(M)(S)1
10-BIT DIGITALLY ENCODED BI-DIRECTIONAL VIDEO WITH 1 BI-DIRECTIONAL DATA CHANNEL, 2 BI-DIRECTIONAL 24-BIT AUDIO CHANNELS AND 1 BI-DIRECTIONAL CONTACT CLOSURE
The FVTR1D1A2C1 is a bi-directional 10-bit video transmission system along
with one channel of bi-directional data, two channels of bi-directional audio
and one bidirectional contact.
The data channel is configured using a two position switch to operate as RS232,
RS422 or RS485, either two (2) wire or four (4) wire. See Figure 4 on Page 3
for details.
The FVTR1D1A2C1 may be directly plugged into the ComNet Rack (Part #C1) or
operated as a standalone module powered by the PS-9VDC power supply also
provided with the module. See Page 5 for mounting instructions.
The FVTR1D1A2C1 requires one optical fiber and may be supplied in a
multimode (M) or single mode (S) version.
See Figures 1 – 7 for complete installation details.
INS_FVTR1D1A2C1_REV–
6/16/10
PAGE 1
Page 2
INSTALLATION AND OPERATION MANUAL FVTR1D1A2C1
FIGURE 1 – FVTR1D1A2C1 TRANSCEIVER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK
BLACK WITH WHITE STRIPE
Power Supply:
Surface Mount: 8–15 VDC @ 2W
Rack Mount: From Rack
FIGURE 2 – FVTR1D1A2C1 TRANSCEIVER
REAR PANELFRONT PANEL
Video termination Switch
Set switch to TERM (Terminate) when video is not looping to other video devices or is the last device in a looping configuration.
NOTE: Remove Electrical Connector for Rack Mount Units
TECH SUPPORT: 1.888.678.9427
INS_FVTR1D1A2C1_REV–
6/16/10
PAGE 2
Page 3
INSTALLATION AND OPERATION MANUAL FVTR1D1A2C1
FIGURE 3 – SWITCH POSITIONS
The mode for each data channel is configured using a set of two switches on the front panel of the unit.
FIGURE 4 – DATA CONNECTIONS
Customer
FVTR1D1A2C1A
RS232
RS422
Bi-phase or Manchester
2-Wire
RS485,
Sensornet
Equipment
Data Transmit
Data Receive
Signal Ground
Data Out (+)
Data Out (-)
Data In (+)
Data In (-)
Data In (+)
Data In (-)
Data (A)
Data (B)
DIN(-)
DOUT(-)
GND
DIN(+)
DIN(-)
DOUT(+)
DOUT(-)
DOUT(+)
DOUT(-)
DIN(+)
DIN(-)
FVTR1D1A2C1B
DOUT(-)
DIN(-)
GND
DOUT(+)
DOUT(-)
DIN(+)
DIN(-)
DIN(+)
DIN(-)
DIN(+)
DIN(-)
Customer
Equipment
Data Receive
Data Transmit
Signal Ground
Data In (+)
Data In (-)
Data Out (+)
Data Out (-)
Data Out (+)
Data Out (-)
Data (A)
Data (B)
Data Out (A)
4-Wire RS485
TECH SUPPORT: 1.888.678.9427
Data Out (B)
Data In (A)
Data In (B)
DIN(+)
DIN(-)
DOUT(+)
DOUT(-)
DOUT(+)
DOUT(-)
DIN(+)
DIN(-)
Data In (A)
Data In (B)
Data Out (A)
Data Out (B)
INS_FVTR1D1A2C1_REV–
6/16/10
PAGE 3
Page 4
INSTALLATION AND OPERATION MANUAL FVTR1D1A2C1
FIGURE 5 – AUDIO AND CONTACT CONNECTORS
AUDIO
CONTACT CLOSURE
FIGURE 6 – DATA CONNECTIONS
See Page 3 for Switch Settings
Rear Panel
1) RS232
1 DIN (–) 2 DOUT (–) 3 Ground
FIGURE 7 – LED INDICATORS
FIBER VIDEO IN VIDEO OUT DATA AUDIO CONTACT POWER
GREEN
RED
OFF
Communication link has
been established over
optical fiber
Communication link has
not been established
Not powered up correctly – No data signal No audio signal Open Unit powered down
An active video signal is present on the BNC connector.
No video input signal
An active video signal is present on the BNC connector.
No video output signal
2) RS422, Manchester & Bi-Phase
1 DIN (+) 2 DIN (–) 3 DOUT (+)
3) RS485 2-wire, Sensornet
1 DIN (+) 2 DIN (–) 3 Ground
4) RS485 4-wire
1 DIN (+) 2 DIN (–) 3 DOUT (+) 4 DOUT (–)
5 Ground 4 DOUT (–) 5 Ground
An active data
signal is present
on the input pins of
the data connector.
–––
(Solid or Blinking)
An active audio
signal is present
Closed Unit powered up
TECH SUPPORT: 1.888.678.9427
INS_FVTR1D1A2C1_REV–
6/16/10
PAGE 4
Page 5
MECHANICAL INSTALLATION INSTRUCTIONS
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
FIGURE A
Dimensions are for a standard ComNet™ two slot module
.156 [3.96 mm]
.313 [7.95 mm]
IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not compromised.
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET
INS_FVTR1D1A2C1_REV–
© 2010 Communications Networks Corporation. All Rights Reser ved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC.
6/16/10
PAGE 5