Comnet FVT40SFP User Manual

Page 1
INSTALLATION AND OPERATION MANUAL
FVT/FVR40SFP
4-CHANNEL DIGITALLY ENCODED VIDEO USING SMALL FORM-FACTOR PLUGGABLE (SFP) OPTICAL DEVICES
The FVT/FVR40SFP series optical video link provides transmission of four 10-bit
small form factor pluggable module (SFP). See instructions included with SFP
for installation of selected module.
Bi-color (Red/Green) LED indicators are provided for confirming operating
status. See Figure 4 on Page 3 for LED indication explanations.
These units are interchangeable between stand-alone or card mount
configurations. See Figure A on Page 4 for mounting instructions.
INS_FVT/FVR40SFP_REV–
05/07/10
PAGE 1
Page 2
INSTALLATION AND OPERATION MANUAL FVT/FVR40SFP
FIGURE 1 – FVT/FVR40SFP TRANSMITTER AND RECEIVER
OPTICAL FIBER DETERMINED BY SELECTION OF SFP MODULE
BLACK
BLACK WITH WHITE STRIPE
FIGURE 2 – FVT40SFP TRANSMITTER
REAR PANEL REAR PANELFRONT PANEL FRONT PANEL
NOTE: Remove Electrical Connector for Rack Mount Units
FIGURE 3 – FVR40SFP RECEIVER
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR40SFP_REV–
05/07/10
PAGE 2
Page 3
INSTALLATION AND OPERATION MANUAL FVT/FVR40SFP
FIGURE 4 – LED INDICATORS
LINK VIDEO POWER
GREEN
RED
OFF
Communication link has been established over optical fi ber
Communication link has not
An active video signal is present on the BNC connector.
No Video Signal
Unit powered up
been established.
Not powered up correctly Unit powered down
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR40SFP_REV–
05/07/10
PAGE 3
Page 4
MECHANICAL INSTALLATION INSTRUCTIONS
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
FIGURE A
Dimensions are for a standard ComNet™ one slot module
.156 [3.96 mm]
.313 [7.95 mm]
IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not compromised.