Comnet FVT110M1-BO, FVR110S1-BO, FVT110S1-BO, FVR110M1-BO Operation Manual

Page 1
INSTALLATION AND OPERATION MANUAL
FVT/FVR110(M,S)1[/M]
10-BIT DIGITAL VIDEO WITH ONE BI-DIRECTIONAL DATA CHANNEL
The ComNet FVT/FVR110 series is a video transmitter/receiver and data transceiver that supports the simultaneous transmission of short haul quality 10-bit EIA RS-250C digitally encoded video and bi-directional data over one multimode or single mode optical fiber. The FVT110 also transmits a single bi-directional contact closure signal.
The module is universally compatible with major CCTV camera manufacturers. Figures 6 and 7 starting on Page 4 illustrate the specific data connections for RS232, RS422, 2 or 4-wire RS485 data transmission.
The FVT/FVR110 also supports “up-the-coax” data transmission from all major manufacturers, utilizing time-base correction these units can achieve distances of 48km. The FVT/FVR110 supports Panasonic Proteus™, Pelco Coaxitron™ and Bosch Bilinx™ Up-the-Coax systems.
Bi-color (Red/Green) LED indicators are provided for rapidly ascertaining equipment operating status. Figure 10 on Page 6 describes the LED indicators for each light on the unit.
The FVT110 and FVR110 units are interchangeable between stand-alone or card mount configurations, or may be DIN-rail mounted by the addition of ComNet model DINBKT1 adaptor plate. The FVT110M is stand-alone only. See Figure A on Page 8 for mounting instructions.
INS_FVT/FVR110_REV–
10/27/11
PAGE 1
Page 2
INSTALLATION AND OPERATION MANUAL FVT/FVR110(M,S)1[/M]
FIGURE 1 – FVT/FVR110 TRANSMITTER AND RECEIVER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK
BLACK WITH WHITE STRIPES
FIGURE 2 – FVT110 TRANSMITTER
REAR PANEL REAR PANELFRONT PANEL FRONT PANEL
Operating Voltage Range: 8–15 VDC Power Consumption: 6W Max NOTE: Remove Electrical Connector for Rack Mount Units
FIGURE 3 – FVR110 RECEIVER
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR110_REV–
10/27/11
PAGE 2
Page 3
INSTALLATION AND OPERATION MANUAL FVT/FVR110(M,S)1[/M]
FIGURE 4 – FVT110/M TRANSMITTER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK
BLACK WITH WHITE STRIPES
Operating Voltage Range: 8–15 VDC Power Consumption: 6W Max
FIGURE 5 – FVT110M TRANSMITTER
REAR PANELFRONT PANEL
OPTICALVIDEO IN
DATA FORMAT
LEDs: LINK VIDEO DATA
GND +Vin
INS_FVT/FVR110_REV–
10/27/11
PAGE 3
Page 4
INSTALLATION AND OPERATION MANUAL FVT/FVR110(M,S)1[/M]
FIGURE 6 – DATA SWITCH POSITIONS
The mode for each data channel is configured using a pair of switches on the front panel of the unit.
Switch 1 Switch 2 Resulting Mode
ON ON RS232
Switch
FVT110
FVT110/M
FVR110
ON OFF
OFF ON
RS422, Bi-Phase or Manchester
RS485 2W, Sensornet
OFF OFF RS485 4W
GND DIN– DIN+ DOUT– DOUT+
RS232
RS422, Bi-Phase,
Manchester
RS485 2W, Sensornet
TECH SUPPORT: 1.888.678.9427
RS485 4W
INS_FVT/FVR110_REV–
10/27/11
PAGE 4
Page 5
INSTALLATION AND OPERATION MANUAL FVT/FVR110(M,S)1[/M]
FIGURE 7 – DATA CONNECTIONS
UTC Control
RS232
RS422
Bi-phase or
Manchester
Customer
Equipment
Up-the-Coax
Control Receiver
Data Transmit
Data Receive
Signal Ground
Data Out (+)
Data Out (–)
Data In (+)
Data In (–)
Data In (+)
Data In (–)
FVT110
VIDEO IN
DIN(–)
DOUT(–)
GND
DIN(+)
DIN(–)
DOUT(+)
DOUT(–)
DOUT(+)
DOUT(–)
FVR110
VIDEO OUT
DOUT(–)
DIN(–)
GND
DOUT(+)
DOUT(–)
DIN(+)
DIN(–)
DIN(+)
DIN(–)
Customer
Equipment
Up-the-Coax
Control Transmitter
Data Receive
Data Transmit
Signal Ground
Data In (+)
Data In (–)
Data Out (+)
Data Out (–)
Data Out (+)
Data Out (–)
2-Wire
RS485
4-Wire
RS485
Data (A)
Data (B)
Data Out (A)
Data Out (B)
Data In (A)
Data In (B)
DIN(+)
DIN(–)
DIN(+)
DIN(–)
DOUT(+)
DOUT(–)
DIN(+)
DIN(–)
DOUT(+)
DOUT(–)
DIN(+)
DIN(–)
Data (A)
Data (B)
Data In (A)
Data In (B)
Data Out (A)
Data Out (B)
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR110_REV–
10/27/11
PAGE 5
Page 6
INSTALLATION AND OPERATION MANUAL FVT/FVR110(M,S)1[/M]
FIGURE 8 – CONTACT CHANNEL
Small SizeFull Size
Dry contact closure input. Applying a voltage to these pins may damage the unit.
Dry contact closure input. Applying a voltage to these pins may damage the unit.
FIGURE 9 – CONTACT CHANNEL SWITCH SETTINGS
The switch is located on the front of the standard size units. The FVT110M small-size unit only supports the CIN mode.
The contact channel in the full-size (ComFit) units can operate in one of four modes as determined by the two DIP switches located at the front of each FVT and FVR unit as described below. The contact channel in the compact-size units only operates in the IBCC Mode as described below so there are no DIP switches on the unit to set contact channel mode.
Contact Channel
Switch Settings
Switch 1 Switch 2 Contact Channel Mode
ON ON IBCC - Independent Bi-directional Contact Closure Mode OFF ON VSS - Video Signal Status Mode ON OFF OLS - Optical Link Status Mode OFF OFF NOLS - Negative Optical Link Status Mode
IBCC – Independent Bi-directional Contact Closure Mode
· In this mode, the FV T and FVR must be properly powered and there must be a good optical link between the FVT and the FVR.
· A dry closure across the CIN pair at one unit will result in a non-latching relay contact closure across COUT of the unit at the opposite end of the fiber path. Otherwise, the relay contacts across COUT are normally open. The channel can support closure status in both directions simultaneously.
VSS – Video Signal Status Mode
· In this mode, the FV T and FVR must be properly powered and there must be a good optical link between the FVT and the FVR.
· The presence of a good composite analog video signal at the BNC input of the FVT unit will cause the relay contacts across COUT of the FVR to close. Lack of a good composite analog video signal at the BNC input of the FVT unit will cause the relay contacts across COUT of the FVR to open.
· The status – open or shor ted – across the CIN pair of the FVT is not passed to the FVR in this mode.
· A dry closure across the CIN pair of the FVR will cause the relay contacts across COUT of the FVT to open. Lack of a dry closure across the CIN pair of the FVR will cause the relay contacts across COUT of the FVT to close.
OLS – Optical Link Status Mode
· In this mode, the FV T and FVR must be properly powered.
· The presence of a good optical link between the FVT and the FVR units will cause the relay contacts across COUT of the FVT and the FVR to close. Loss of optical link between the FVT and the FVR units will cause the relay contacts across COUT of the FVT and the FVR to open.
· The status – open or shor ted – across the CIN pair of the FVT or the FVR is not passed in this mode.
NOLS – Negative Optical Link Status Mode
· In this mode, the FV T and FVR must be properly powered.
· The presence of a good optical link between the FVT and the FVR units will cause the relay contacts across COUT of the FVT and the FVR to open. Loss of optical link between the FVT and the FVR units will cause the relay contacts across COUT of the FVT and the FVR to close.
· The status – open or shor ted – across the CIN pair of the FVT or the FVR is not passed in this mode.
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR110_REV–
10/27/11
PAGE 6
Page 7
INSTALLATION AND OPERATION MANUAL FVT/FVR110(M,S)1[/M]
FIGURE 10 – LED INDICATORS on Transmitter (FVT) and Receiver (FVR)
Indicator
Device
LED Status POWER LED LINK LED VIDEO LED DATA LED CIN LED COUT LED
OFF device is not
powered or is not powered properly
SOLID RED N/A optical link
FVT
SOLID GREEN device is powered
properly
OFF device is not
powered or is not powered properly
SOLID RED N/A optical link
FVR
SOLID GREEN device is powered
properly
N/A N/A active data
signal not present on the pins of the data connector
video signal not
not detected
optical link detected
N/A N/A active data
not detected
optical link detected
present on the BNC connector
video signal present on the BNC connector
video signal not present on the BNC connector
video signal present on the BNC connector
N/A N/A N/A
active data signal present on the pins of the data connector
signal not present on the pins of the data connector
N/A N/A N/A
active data signal present on the pins of the data con­nector
no closure detected across CIN pair
closure detected across CIN pair
no closure detected across CIN pair
closure detected across CIN pair
relay contacts open
IBCC mode - no closure detected across CIN pair at FVR
VSS mode - closure detected across CIN pair at FVR
OLS mode - optical link not detected
NOLS mode - optical link detected
relay contacts closed
IBCC mode - closure detected across CIN pair at FVR
VSS mode - no closure detected across CIN pair at FVR
OLS mode - optical link detected
NOLS mode - optical link not detected
relay contacts open
IBCC mode - no closure detected across CIN pair at FVT
VSS mode - video signal not detected at BNC input at FVT
OLS mode - optical link not detected
NOLS mode - optical link detected
relay contacts closed
IBCC mode - closure detected across CIN pair at FVT
VSS mode - video signal detected at BNC input at FVT
OLS mode - optical link detected
NOLS mode - optical link not detected
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR110_REV–
10/27/11
PAGE 7
Page 8
MECHANICAL INSTALLATION INSTRUCTIONS
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the
card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the
card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 power supply.
FIGURE A
Dimensions are for a standard ComNet™ one slot module
.156 [3.96 mm]
.313 [7.95 mm]
IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not compromised.
FVT/FVR110(M,S)[/M] Part Ordering Options:
(M,S): Fiber Type
M: Multimode
S: Singlemode
[/M]: Mini Long Tall Enclosure (optional)
FIGURE B
Dimensions are for a ComNet™ mini long tall module
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET
© 2017 Communications Networ ks Corporation. All Rights Reser ved. “ComNet ” and the “ComNet Logo” are regis tered trademarks of Communic ation Networks, L LC.
INS_FVT/FVR110_REV–