Comnet FVR41S1 User Manual

INSTALLATION AND OPERATION MANUAL
Value Line FVT/FVR41
4-CHANNEL DIGITAL VIDEO MULTIPLEXER
The FVT/FVR41 is a four (4) channel video transmission system. It combines
this over one optical fiber.
These units may be directly plugged into the ComNet Rack (Part C1) or they
can operate as standalone modules. See Figure A on Page 4 for mounting
instructions.
See Figures 1 – 4 for complete installation details.
INS_FVT/FVR41_REV–
01/27/10
PAGE 1
INSTALLATION AND OPERATION MANUAL FVT/FVR41
FIGURE 1 – FVT/FVR41 TRANSMITTER AND RECEIVER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK
BLACK WITH WHITE STRIPE
FIGURE 2 – FVT41 TRANSMITTER
REAR PANEL REAR PANELFRONT PANEL FRONT PANEL
FIGURE 3 – FVR41 RECEIVER
TECH SUPPORT: 1.888.678.9427
NOTE: Remove Electrical Connector for Rack Mount Units
INS_FVT/FVR41_REV–
01/27/10
PAGE 2
INSTALLATION AND OPERATION MANUAL FVT/FVR41
FIGURE 4 – LED INDICATORS
LINK VIDEO (1 – 4) POWER
GREEN Communication link has An active video signal is Unit powered up
been established over present on the BNC
optical fiber connector.
RED Communication link has No video signal
not been established.
OFF Not powered up correctly – Unit powered down
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR41_REV–
01/27/10
PAGE 3
MECHANICAL INSTALLATION INSTRUCTIONS
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
FIGURE A
Dimensions are for a standard ComNet™ one slot module
.156 [3.96 mm]
.313 [7.95 mm]
IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not compromised.
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET
© 2010 Communications Networks Corporation. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC.
INS_FVT/FVR41_REV–
01/27/10
PAGE 4