Comnet FVR20D2I1C4E, FVT20D2I1C4E User Manual

INSTALLATION AND OPERATION MANUAL
FVT/FVR20D2I1C4E
2-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO + 2 BI-DIRECTIONAL DATA + AIPHONE™ INTERCOM + 4 CONTACT CLOSURE + 100MB ETHERNET + REDUNDANT POINT-TO-POINT DUAL SFP OPTICAL PORTS
The FVT/FVR20D2I1C4E series utilize 10-bit digital video encoding and decoding for high-quality video transmission that meets the requirements of EIA RS-250C for short-haul video transmission. These environmentally hardened units provide transmission of two independent video channels and two bi-directional data channels. They also provide transmission of one Aiphone™ intercom channel and four contact closure channels with tamper supervision in addition to one 10/100Mb Ethernet channel.
The ComNet™ FVT/FVR20D2I1C4E has dual optical (SFP) ports to provide a redundant point-to-point fail safe topology in the event of loss of one fiber or one optical module.
Operational status can be monitored by using the web management interface through the addition of the ComNet network managed chassis and network management interface module.
Bi-color (red/green) LED indicators are provided for confirming operating status in addition to alarm contacts for fault monitoring. See Figure 15 on Page 9 for LED explanations.
Packaged in the exclusive ComNet ComFit housing, these units may be either wall or rack-mounted (using ComNet C2 network-managed rack), or may be DIN-rail mounted by the addition of ComNet model DINBKT1 adaptor plate. See Figure A on Page 10 for mounting instructions.
INS_FVT/FVR20D2I1C4E_REV- 06/22/12 PAGE 1
INSTALLATION AND OPERATION MANUAL FVT/FVR20D2I1C4E
FIGURE 1 – FVT/FVR20D2I1C4E TRANSMITTER AND RECEIVER
Optical fiber determined by Selection of Small Form-factor Pluggable (SFP) modules*.
(–) BLACK
(+) BLACK W/ WHITE STRIPE
(–) BLACK
(+) BLACK W/ WHITE STRIPE
* One SFP required for point-to-point operation. Two SFPs required for redundant operation.
Consult factory for compatible SFP Modules.
FIGURE 2 – FVT20D2I1C4E TRANSMITTER
REAR PANEL REAR PANELFRONT PANEL FRONT PANEL
FIGURE 3 – FVR20D2I1C4E RECEIVER
Power Supply: Dual 8-24VDC @ 4W Rack Mount: C2 Network-Managed
NOTE: Remove PWR1 Electrical Connector for Rack Mount Units
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR20D2I1C4E_REV- 06/22/12 PAGE 2
INSTALLATION AND OPERATION MANUAL FVT/FVR20D2I1C4E
FIGURE 4 – RJ45 BREAK-OUT – FVT20D2I1C4E TRANSMITTER
4 pc. Factory Supplied
RJ-45 PORTS
Located on Rear Panel
CADD
VIEW INSIDE RJ-45 PORT
RJ-45 BREAK-OUT KIT
Screw Number Corresponds to RJ-45 Port Pin Number
D (DATA PORTS)
PIN # Wire Color Data Connections
1 Blue DATA OUT –
2 Orange DATA OUT +
3 Black DATA IN +
4 Red RELAY OUT
5 Green RELAY OUT
6 Yellow DATA IN –
7 Brown GND
8 White +5V (BIAS)
C (CONTACT PORT)
PIN # Wire Color TX Connections
1 Blue IN 1+
2 Orange IN 1–
3 Black IN 2+
4 Red IN 3+
5 Green IN 3 –
6 Yellow IN 2–
7 Brown IN 4+
8 White IN 4–
TECH SUPPORT: 1.888.678.9427
A (AIPHONE™ PORT)
PIN # Wire Color Aiphone Connections
1 Blue LE-D ‘-’ TERMINAL
2 Orange LE-D ‘1’ TERMINAL
3 Black LE-D ‘E’ TERMINAL
4 Red RELAY OUTPUT COM
5 Green RELAY OUTPUT N.C.
6 Yellow RELAY OUTPUT N.O.
7 Brown GND
8 White GND
INS_FVT/FVR20D2I1C4E_REV- 06/22/12 PAGE 3
INSTALLATION AND OPERATION MANUAL FVT/FVR20D2I1C4E
FIGURE 5 – RJ45 BREAK-OUT – FVR20D2I1C4E RECEIVER
4 pc. Factory Supplied
RJ-45 PORTS
Located on Rear Panel
CADD
VIEW INSIDE RJ-45 PORT
RJ-45 BREAK-OUT KIT
Screw Number Corresponds to RJ-45 Port Pin Number
D (DATA PORTS)
PIN # Wire Color Data Connections
1 Blue DATA OUT –
2 Orange DATA OUT +
3 Black DATA IN +
4 Red RELAY OUT
5 Green RELAY OUT
6 Yellow DATA IN –
7 Brown GND
8 White +5V (BIAS)
C (CONTACT PORT)
PIN # Wire Color RX Connections
1 Blue OUT1 +
2 Orange OUT1 –
3 Black OUT2 +
4 Red OUT3 +
5 Green OUT3 –
6 Yellow OUT2 –
7 Brown OUT4 +
8 White OUT4 –
TECH SUPPORT: 1.888.678.9427
A (AIPHONE™ PORT)
PIN # Wire Color Aiphone Connections
1 Blue LEF ‘E’ TERMINAL
2 Orange LEF ‘1’ TERMINAL
3 Black LEF ‘–’ TERMINAL
4 Red NC
5 Green CONTACT INPUT +
6 Yellow NC
7 Brown GND
8 White GND
NC = No Connection
INS_FVT/FVR20D2I1C4E_REV- 06/22/12 PAGE 4
INSTALLATION AND OPERATION MANUAL FVT/FVR20D2I1C4E
FIGURE 6 – DATA SWITCH POSITIONS
The mode for each data channel is configured using a set of two switches labeled DATA1 (S3) and DATA2 (S4), located on the front panel of the unit.
DATA1 (S3) DATA2 (S4)
Resulting Mode1 2 1 2
ON ON ON ON RS232
ON OFF
OFF ON OFF ON RS485 2-Wire, Sensornet
OFF OFF OFF OFF RS485 4-Wire
FIGURE 7 – RJ-45 PIN OUT
OFF RS422, Bi-Phase or Manchester
ON
PIN # Wire Color Data Connections
1 Blue DATA OUT –
2 Orange DATA OUT +
3 Black DATA IN +
4 Red RELAY OUT
5 Green RELAY OUT
6 Yellow DATA IN –
7 Brown GND
8 White +5V (BIAS)
PIN # RS232 RS422 RS485 2-Wire RS485 4-Wire
1 NC RS422 OUTPUT – NC RS485 OUTPUT –
2 RS232 – OUTPUT RS422 OUTPUT + NC RS485 OUTPUT +
3 NC RS422 INPUT + RS485 INPUT + RS485 INPUT +
4 RELAY OUT RELAY OUT RELAY OUT RELAY OUT
5 RELAY OUT RELAY OUT RELAY OUT RELAY OUT
6 RS232 – INPUT RS422 INPUT – RS485 INPUT – RS485 INPUT –
7 GND GND GND GND
8 +5V (BIAS) +5V (BIAS) +5V (BIAS) +5V (BIAS)
NC = No Connection
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR20D2I1C4E_REV- 06/22/12 PAGE 5
INSTALLATION AND OPERATION MANUAL FVT/FVR20D2I1C4E
FIGURE 8 – DATA CONNECTIONS
See Page 5 for Switch Settings
Customer
Equipment
FVT20D2I1C4E
FVR20D2I1C4E
Customer
Equipment
RS232
RS422
Bi-phase or
Manchester
2-Wire
RS485,
Sensornet
Data Transmit
Data Receive
Signal Ground
Data Out (+)
Data Out (-)
Data In (+)
Data In (-)
Data In (+)
Data In (-)
Data (A)
Data (B)
DIN(-)
DOUT(+)
GND
DIN(+)
DIN(-)
DOUT(+)
DOUT(-)
DOUT(+)
DOUT(-)
DIN(+)
DIN(-)
DOUT(+)
DIN(-)
GND
DOUT(+)
DOUT(-)
DIN(+)
DIN(-)
DIN(+)
DIN(-)
DIN(+)
DIN(-)
Data Receive
Data Transmit
Signal Ground
Data In (+)
Data In (-)
Data Out (+)
Data Out (-)
Data Out (+)
Data Out (-)
Data (A)
Data (B)
4-Wire
RS485
Data Out (A)
Data Out (B)
Data In (A)
Data In (B)
DIN(+)
DIN(-)
DOUT(+)
DOUT(-)
FIGURE 9 – POSSIBLE ETHERNET CONFIGURATION
Ethernet IEEE 802.3 Network Element determined by user.
CAT5e/6 with
RJ45 Connections
Ethernet IEEE 802.3
Network Element
FVT20D2I1C4E FVR20D2I1C4E
Optical Fiber
SC or LC
Connectors
SINGLE FIBER SFP MODULE
DOUT(+)
DOUT(-)
DIN(+)
DIN(-)
Data In (A)
Data In (B)
Data Out (A)
Data Out (B)
CAT5e/6 with
RJ45 Connections
Ethernet IEEE 802.3
Network Element
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR20D2I1C4E_REV- 06/22/12 PAGE 6
INSTALLATION AND OPERATION MANUAL FVT/FVR20D2I1C4E
FIGURE 10 – SFP CONNECTIONS
Number of fibers and type of fiber connectors will be determined by selected SFP modules and if point-to-point or redundant modes are required.
FIGURE 11 – AIPHONE™ INTERCOM CONNECTIONS
The units are designed to operate with the Aiphone™ LE-D and LEF intercom system.
FVT20D2I1C4E
PIN # Wire Color Aiphone Connections
1 Blue LE-D ‘-’ TERMINAL
2 Orange LE-D ‘1’ TERMINAL
3 Black LE-D ‘E’ TERMINAL
4 Red RELAY OUTPUT COM
5 Green RELAY OUTPUT N.C.
6 Yellow RELAY OUTPUT N.O.
7 Brown GND
8 White GND
LE-D FVR20D2I1C4E
FVT20D2I1C4E
3 3E
2 121
1 E
FVR20D2I1C4E
PIN # Wire Color Aiphone Connections
1 Blue LEF ‘E’ TERMINAL
2 Orange LEF ‘1’ TERMINAL
3 Black LEF ‘–’ TERMINAL
4 Red NC
5 Green CONTACT INPUT +
6 Yellow NC
7 Brown GND
8 White GND
LEF
1
TECH SUPPORT: 1.888.678.9427
5 54 76
Form ‘C’ Relay Output
Door/Barrier
Contact Input
INS_FVT/FVR20D2I1C4E_REV- 06/22/12 PAGE 7
INSTALLATION AND OPERATION MANUAL FVT/FVR20D2I1C4E
FIGURE 12 – CONTACT SWITCH POSITIONS
The mode for contact closure operation is configured using a set of two switches labeled CONTACT (S1) located on the front panel of the unit. There are four supervised contacts in the forward (video) direction.
CONTACT (S1)
Resulting Mode1 2
ON ON Full Supervision – When a 1K resistor is connected in series with
the contact closure input, and a 1K resistor is connected in parallel across the contact closure input. Both open circuits and short circuits can be detected as well as normal opens and closes.
OFF Series Supervision – When a 1K resister is connected in series with
the contact closure input. In this mode, shorts across the contact inputs can be detected but open circuits cannot be detected.
across the contact closure input. In this mode, open circuits can be detected but short circuits cannot be detected.
no Supervision.
NOTE: These switch settings refer to the trans-
mitter (FVT20D2I1C4E). On the receiver (FVR20D2I1C4E), S1 SWITCH 1 inverts the contact outputs. S1 SWITCH 2 is not used.
ON
OFF ON Parallel Supervision – When a 1K resistor is connected in parallel
OFF OFF No Supervision – The contacts will behave as normal contacts with
FIGURE 13 – CONTACT CLOSURE SUPERVISED INPUT CIRCUIT
INTERNAL
5V
1K Series*
1K
Parallel*
1K
1K
* Optional external resistors
(provided) are required for supervision. Place close to the switch for optimal results.
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR20D2I1C4E_REV- 06/22/12 PAGE 8
INSTALLATION AND OPERATION MANUAL FVT/FVR20D2I1C4E
FIGURE 14 – ALARM SWITCH POSITIONS
The mode for alarm operation is configured using a set of two switches labeled ALARM (S2) located on the front panel of the unit. There are two alarm out­puts on each unit. One on each RJ45 data connector. See Figures 4 & 5 on Pages 3 & 4.
ALARM (S2)
Resulting Mode1 2
Alarm 1 – SFP 1 Failure Alarm 2 – SFP 2 Failure
Alarm 1 – SFP 1 or SFP 2 Failure Alarm 2 – Video Loss
Alarm 1 – SFP 1 Failure or Video Loss Alarm 2 – SFP 2 Failure or Video Loss
Alarm 1 – SFP 1 or SFP 2 Failure or Video Loss Alarm 2 – SFP 1 or SFP 2 Failure or Video Loss
NOTE: The ALARM will also open when Fiber Link
on either SFP port is lost or if Power is lost on either unit.
ON ON
ON OFF
OFF ON
OFF OFF
FIGURE 15 – LED INDICATORS
OFF RED GREEN FLASHING
SFP SFP not installed No optical link Link is good and is in use
VIDEO – No video signal
10/100 LINK – No Ethernet signal Ethernet signal linked
CONTACT (C)
CONTACT (S) –
DATA IN Tri-state Low state High state Data activity
DATA OUT Tri-state Low state High state Data activity
POWER Unit powered down Unit powered up
One or more contacts are open
LE-D – Quiet / No Audio Audio Present Call button active
LE-F – Quiet / No Audio Audio Present
Fiber link failed
Supervised contact alarm or fiber link failed
An active video signal is present
All four contacts are closed
No supervised contacts in alarm state
Link is good but is not in use
GREEN Solid: Link (no activity)
TECH SUPPORT: 1.888.678.9427
YELLOW Solid: Highest data rate (100Mbs) Blinking: Activity Off: No link
INS_FVT/FVR20D2I1C4E_REV- 06/22/12 PAGE 9
MECHANICAL INSTALLATION INSTRUCTIONS
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity.
C2 NETWORK MANAGED RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 power supply.
FIGURE A
Dimensions are for a standard ComNet™ two slot module
.156 [3.96 mm]
.313 [7.95 mm]
IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not compromised.
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET
© 2013 Communications Ne tworks Cor poration. All Rights Reser ved. “ComNet ” and the “ComNet Logo” are regis tered trademarks of Communic ation Networ ks, LLC.
INS_FVT/FVR20D2I1C4E_REV- 06/22/12 PAGE 10
Loading...