INSTALLATION AND OPERATION MANUAL
FVR1C1B(M,S)1
8-BIT DIGITALLY ENCODED VIDEO RECEIVER
WITH CONTACT CLOSURE
The FVR1C1B receives one channel of video and contact closure over optical
fiber utilizing state-of-the-art 8-bit digital decoding for high-quality video
transmission. These units are completely transparent to and universally
compatible with any NTSC, PAL, or SECAM CCTV camera systems. Plug-and-
play design ensures ease of installation and no electrical or optical adjustments
are ever required.
Bi-color (Red/Green) LED indicators are provided for rapidly ascertaining
equipment operating status. See Figure 4 on Page 3 for an explanation of LED
indicators.
These units may be either wall or rack-mounted, or may be DIN-rail mounted by
the addition of ComNet model DINBKT1 adaptor plate. See Figure A on Page 4
mounting instructions.
See Figures 1 – 3 for complete installation details.
INS_FVR1C1B_REV–
12/06/10
PAGE 1

INSTALLATION AND OPERATION MANUAL FVR1C1B(M,S)1
FIGURE 1 – FVR1C1B1 RECEIVER
MULTIMODE
OR SINGLE MODE
OPTICAL FIBERS
BLACK (GND)
BLACK WITH WHITE STRIPE (8 – 15VDC)
FIGURE 3 – FVR1C1B1 RECEIVER
REAR PANELFRONT PANEL
NOTE: Remove Electrical
Connector for Rack Mount Units
TECH SUPPORT: 1.888.678.9427
INS_FVR1C1B_REV–
12/06/10
PAGE 2

INSTALLATION AND OPERATION MANUAL FVR1C1B(M,S)1
FIGURE 3 – LED INDICATORS
VIDEO CONTACT
GREEN
RED
OFF
Video signal is present Contact Closed
No video signal is
present
– Contact Open
–
FIGURE 4 – CONTACT SETTINGS
Open Circuit ≤ 30 VDC
Closed Current ≤ 500 mA
CONTACT
GROUND
TECH SUPPORT: 1.888.678.9427
INS_FVR1C1B_REV–
12/06/10
PAGE 3

MECHANICAL INSTALLATION INSTRUCTIONS
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units
should be installed in dry locations protected from extremes of
temperature and humidity.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that
the power supply be turned off and that the rack power supply
is disconnected from any power source. Note: Remove electrical
connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into
the card guides in the rack until the edge connector at the back
of the card seats in the corresponding slot in the rack’s connector
panel. Seating may require thumb pressure on the top and bottom
of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of
the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated
9-12 VDC @ 1A.
FIGURE A
Dimensions are for a standard ComNet one slot module
.156 [3.96 mm]
.313 [7.95 mm]
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may
be greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA
T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE
T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET
© 2011 Communications Networks Corporation. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC.
INS_FVR1C1B_REV–
12/06/10
PAGE 4