Comnet FVT10D1E, FVR10D1E, FVR10D1EM, FVR10D1ES, FVT10D1EM Installation And Operation Manual

...
Page 1
INSTALLATION AND OPERATION MANUAL
FVT/FVR10D1E(M,S)[M]
10-BIT DIGITALLY ENCODED VIDEO TRANSMITTER WITH 1 BI-DIRECTIONAL DATA CHANNEL AND 10/100MB ETHERNET
system along with one channel of bi-directional data and one full duplex
10/100 Mbps Fast Ethernet port.
The data channel is configured using a two position switch to operate as RS232,
RS422 or RS485, either two (2) wire or four (4) wire. See Figure 7 for details.
The video channel also supports “up-the-coax” reverse data that is enabled
automatically.
The Ethernet uses a RJ45 data connector. The data input/output also uses
an RJ45 data connector and a “breakout box” to facilitate attachment of the
external wires. The breakout box and connecting cable are supplied with the
FVT/FVR10D1E module.
The FVT/FVR10D1E may be directly plugged into the ComNet Rack (Part #C1)
or operated as a standalone module powered by the PS-9VDC power supply
also provided with the module.
The FVT/FVR10D1E requires one optical fiber and may be supplied in a
multimode (M) or singlemode (S) version.
See Figures 1 – 11 for complete installation details.
INS_FVT/FVR10D1E_REV–
12/28/09
PAGE 1
Page 2
INSTALLATION AND OPERATION MANUAL FVT/FVR10D1E
FIGURE 1 – FVT/FVR10D1E TRANSMITTER AND RECEIVER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK
BLACK WITH WHITE STRIPE
FIGURE 2 – FVT10D1E TRANSMITTER
REAR PANEL REAR PANELFRONT PANEL FRONT PANEL
Power Supply: Surface Mount: 8–15 VDC @ 350mA Rack Mount: From Rack
FIGURE 3 – FVR10D1E RECEIVER
TECH SUPPORT: 1.888.678.9427
NOTE: Remove Electrical Connector for Rack Mount Units
INS_FVT/FVR10D1E_REV–
12/28/09
PAGE 2
Page 3
INSTALLATION AND OPERATION MANUAL FVT/FVR10D1E
FIGURE 4 – FVT10D1EM MINI TRANSMITTER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK
BLACK WITH WHITE STRIPE
Power Supply: Surface Mount: 8–15 VDC @ 350mA
FIGURE 5 – FVT10D1E TRANSMITTER
LEDs: POWER FIBER VIDEO DATA
DIN+ DIN– TERM DOUT+ DOUT– BIAS GND
ETHERNET
REAR PANELFRONT PANEL
OPTICAL
VIDEO IN
GND +Vin
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR10D1E_REV–
12/28/09
PAGE 3
Page 4
INSTALLATION AND OPERATION MANUAL FVT/FVR10D1E
FIGURE 6 – RJ45 BREAK-OUT
Factory Supplied
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR10D1E_REV–
12/28/09
PAGE 4
Page 5
INSTALLATION AND OPERATION MANUAL FVT/FVR10D1E
FIGURE 7 – SWITCH POSITIONS
The mode for each data channel is configured using a set of two switches on the front panel of the unit. The mode for the data on the FVT10D1E(M,S)M small size unit is set by the receiving unit it is connected to.
FIGURE 8 – SWITCH SETTINGS
RS232
1 NC 2 IN (-) 3 Ground 4 NC 5 OUT (-) 6 NC 7 NC 8 NC
RS485 (2W) & SENSORNET
1 IN/OUT (+) A 2 IN/OUT (-) B 3 Ground 4 NC 5 NC 6 NC 7 NC 8 NC
RS422, RS485 (4W), Manchester & Bi-Phase
1 IN (+) 2 IN (-) 3 Ground 4 OUT (+) 5 OUT (-) 6 NC 7 NC 8 NC
NC = No Connection
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR10D1E_REV–
12/28/09
PAGE 5
Page 6
INSTALLATION AND OPERATION MANUAL FVT/FVR10D1E
FIGURE 9 – DATA CONNECTIONS
See Page 5 for Switch Settings
RS-232*
RS-422*
Bi-phase or
Manchester*
2-Wire
RS-485,
Sensornet*
Customer
Equipment
Data Transmit
Data Receive
Signal Ground
Data Out (+)
Data Out (-)
Data In (+)
Data In (-)
Data In (+)
Data In (-)
Data (A)
Data (B)
FVT10D1E
DIN(-)
DOUT(-)
GND
DIN(+)
DIN(-)
DOUT(+)
DOUT(-)
DOUT(+)
DOUT(-)
DIN(+)
DIN(-)
FVR10D1E
DOUT(-)
DIN(-)
GND
DOUT(+)
DOUT(-)
DIN(+)
DIN(-)
DIN(+)
DIN(-)
DIN(+)
DIN(-)
Customer
Equipment
Data Receive
Data Transmit
Signal Ground
Data In (+)
Data In (-)
Data Out (+)
Data Out (-)
Data Out (+)
Data Out (-)
Data (A)
Data (B)
4-Wire
RS-485*
Data Out (A)
Data Out (B)
Data In (A)
Data In (B)
DIN(+)
DIN(-)
DOUT(+)
DOUT(-)
DOUT(+)
DOUT(-)
DIN(+)
DIN(-)
Data In (A)
Data In (B)
Data Out (A)
Data Out (B)
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR10D1E_REV–
12/28/09
PAGE 6
Page 7
FIGURE 10 – ETHERNET CONFIGURATION
Ethernet IEEE 802.3 Network Element determined by user.
Optical Fiber
Ethernet IEEE 802.3
Network Element
RJ45 Connections
FVT10D1E FVR10D1ECAT5E/6 with
CAT5E/6 with
RJ45 Connections
Ethernet IEEE 802.3
Network Element
FIGURE 11 – LED INDICATORS
FIBER VIDEO 10/100 LINK DATA POWER
GREEN Communication link has An active video signal is Ethernet link has been An active data signal is Unit powered up
been established over present on the BNC established at the present on the input pins
optical fiber connector. RJ45 connector. of the data connector.
RED Communication link has No video signal
not been established.
OFF Not powered up correctly No data signal Unit powered down
INS_FVT/FVR10D1E_REV–
12/28/09
PAGE 7
Page 8
MECHANICAL INSTALLATION INSTRUCTIONS
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
FIGURE A
Dimensions are for a standard ComNet™ one slot module
.156 [3.96 mm]
.313 [7.95 mm]
IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not compromised.
FVT/FVR10DIE(M,S)[M] Part Ordering Options:
(M,S): Fiber Type
M: Multimode
S: Singlemode
[M]: Mini Enclosure (optional)
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET
© 2010 Communications Networks Corporation. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC.
INS_FVT/FVR10D1E_REV–
12/28/09
PAGE 8
Loading...