Commercial Electric 5623-WH User Manual

ETL LISTED
AN/CSA STD. C22.2#42.1:200-1
Model #5623-WH
Installation Guide
Flat Panel TV Cable Organizer Kit
PACKAGE CONTENTS
A - Pre-Assembled Top Plate w/ 15 A/125 V duplex receptacle, 8 ft 14/2 with ground pre-stripped electrical building wire and attached mounting wings
B - Bottom Plate with easy push-in connectors and attached mounting wings
C - 6 ft. extension cord w/ 360˚ rotating at head
D - Electrical box
TOOLS NEEDED
Drywall saw Tape measure Phillips head screwdriver Pencil Level Stud Finder
Tape
CAUTION
Intended for use on 15 amp branch circuits
Not intended for use in drywall with re walls
On outside exterior walls with insulation push away insulation to allow proper mounting
For video information visit homedepot.com and search SKU 1001863164 or model number 5623-WH
Installation
1
PREPARING THE WALL FOR INSTALLATION
Determine the top and bottom plate location*
Use the stud nder to center between the wall framing studs.
Be sure to frame your plate both vertically and horizontally
2
Using the template supplied, trace the opening for both the top and
bottom plate on the wall. Remember, the plates are designed to be mounted centered between the studs.
Scan Me
Up to 7’
Outlet Height or 18”
*This kit is designed for standard 2x4 framed walls. If your wall does not have the standard 3.5” spacing between the drywall you will need to use a kit that mounts on the front of the wall.
Up to 6’
TEMPLATE
TIP: Loop a piece of tape with the sticky side outward to form a circle and apply it to the back of the template to secure it to the wall.
CUT DRYWALL FOR TOP AND BOTTOM PLATES
3
With your template secured to the wall with the tape, using a drywall saw, cut a hole in the drywall the size of each template
3026001
Both top and bottom plates are installed between the same two studs.
Page 1 of 4
CONFORMS TO
UL STD. 498
CERTIFIED TO
C
RoHS Compliant This product is patent protected by U.S. Patent number: 7390964B2, 7399920B2,
D553475S, D554475S and D568719S
Installation
ETL LISTED
AN/CSA STD. C22.2#42.1:200-1
4
RUN CABLES THROUGH WALL
Run your low voltage cables and the included 14/2 with ground UL approved electrical building wire from the top opening in the wall through the bottom opening in the wall. TIP: Straighten out the cable from the top plate BEFORE running the cable through the wall. You will need to sh the cables from the top opening to the bottom opening. (For exterior walls as you may need to use the Commercial Electricft Mini Cable Snake) BEFORE installing the top power plate into the top template opening, make sure to pull your low voltage cables through the low voltage cable opening at the back of the plate.
Model #5623-WH
Installation Guide
Flat Panel TV Cable Organizer Kit
5
INSTALLING THE TOP PLATE
After inserting your low voltage cables and the electrical building wire
through the opening for the top plate (A), insert the top plate (A) into the wall by inserting the electrical work box into the wall rst. Slowly slide the top power plate (A) into the opening. Swing the top of the plate into position until the entire plate is ush against the wall. Using a Phillips head screwdriver, tighten the screws with wings. These wings fasten tightly against the back of the drywall. Do not overtighten screws.
A
Installation of Electrical Connectors
6
Now that you have pulled the top power outlet plate’s electrical building wire through the bottom hole on the wall, bend the wire straight. Break the tab on the back of the white old work box (D) and push the stripped end of the wire through the opening. Insert the stripped end of the wires into the push-in connectors. First, insert the stripped black wire into the open side of the push-in connector with the black wire – be sure to push the stripped black wire completely into the connector. Insert the stripped white wire into the open side of the push-in connector with the white wire. Next, insert the bare copper ground wire into the open side of the push-in connector with the green ground wire. Push all of the wires and the push-in connectors into the white old work box. Screw the white old work box to the back of the bottom plate (B).
A
Wall Opening
Connect Here
Electrical Wire
B
D
3026001
Do not plug in the supplied 6ft. extension cord until the installation of the wallplates are completed.
Page 2 of 4
CONFORMS TO
UL STD. 498
CERTIFIED TO
C
RoHS Compliant This product is patent protected by U.S. Patent number: 7390964B2, 7399920B2,
D553475S, D554475S and D568719S