To the InstallerR
Thank you for choosing CommBox Room Movement Sensor (RMS)
The RMS uses passive infra-red technology to detect movement in a room. It is intended to be used with the CommBox range of control systems to automatically shut down equipment in the room after a period of time when no movement is detected, so saving energy and maximising projector lamp life.
Before commencing installation, please read these instructions carefully to get the best results from your RMS.
For your safety
Please ensure that any wiring used to connect RMS to other equipment is kept clear of mains wiring and follows applicable local wiring codes. Under no circumstances may an RMS be connected directly to power mains wiring.
Make sure that the power supply you are using meets your local safety regulations and that its voltage does not exceed 15 volts DC. Unregulated power supplies can output voltages that are well above what is shown on their label.
The RMS is intended for indoor use only.
Mounting
Choose a location on a wall that is preferably 3 to 4 metres from the floor, not adjacent to heating or air conditioning outlets or opposite windows and where people moving in the room can be “seen” by the RMS.
Remove the cover by placing a small flat­bladed screwdriver in the bottom of the case and gently prise the cover off.
DO NOT TOUCH THE PYRO SENSOR INSIDE WITH YOUR FINGERS!
You may remove the circuit board to facilitate mounting the base to the wall. To do this, lift the white plastic tab at the lower side and push the board up until it clears the keyhole slot at the top. At this point the board may be lifted out of the base.
When replacing the board, to achieve optimum coverage, adjust the position of the board in the base to match the height of the RMS above the floor. Moving the board higher will lower the beam angle. Please refer to the Mounting Height scale on the right-hand side of the board.
After wiring, refit the cover with its lens. The cover must be in place in order to test the RMS.
Keyhole slot
Cable access knockout
Mounting height pointer
Mounting hole knockout
Pyro sensor
White plastic tab
This product conforms to the EMC directive 89/336 CCE
Wiring
Connect the terminals as shown in the diagram to the control panel or access port.
You do not need to connect the tamper switch terminals.
Option links
Tamper switch
Alarm + ­ N/C 12v
Blue-Wh GND
Orange +12v
Blue Sensor
PCB0241C
DC In
PIR
RS232 Port 2 RS232 Port 1
IR Otput 1
IR Output 2
Progm Port
IRBus
+12V
GND
Data
RS232 Port Pin 4 - TxD Pin 5 - GND Pin 6 - CTS
PIR Port
Pin 5 - GND
Pin 4 - Sense
Pin 6 - +12V
Command
Systems P/L
Joey Panel
SK9
SK8
SK7
SK6
SK5
SK1
SK2SK4
SK3
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT
PLATE
CUT PLATE
CUT PLATE
Joey
Option Links
For the purpose of detecting room occupancy, we are not as concerned about false alarms as we would be if this were a security system. In fact, not detecting room movement (when people are in the room) would be more of a problem.
For this reason, Long Range and Short Pulse Count links should be fitted. Similarly, having the LED activate is a benefit.
So for our application, fit all 3 links.
Testing
With the cover fitted, apply power and wait at least 30 seconds. After this time, if there is no movement, the LED should go out. Once this has happened, any movement should cause a couple of rapid flickers and the LED should lock on for about 5 seconds.
Walk around the room and check that your movement can be reliably detected. If range seems to be inadequate, check the position of the PCB in the base. A higher position lowers the angle of the detection beam.
Programming your control panel to recognise the RMS and perform actions
In CommBox Control System editor, select Device Options under the Handset menu.
The Inactivity Timeout option allows you to choose the number of minutes after either the last key is pressed or the RMS sensor detects movement. When that time expires with no movement detected or key pressed, the actions you choose under Edit Actions will occur.
After you have selected the time, click Edit Actions. You can treat this just like the programming of any other key.
For more information