Product
Quantity
Main Board(FULL PRODUCT)
1
*If C4 needs to be assembled, the product consists of 1 main board, 12 screws and 6 supporters
C4
CAMS-C(SOFTWARE)
SMART & EFFICIENT NETWORK ACCESS
CONTROLLER
ACCESS CONTROL MANAGEMENT SYSTEM
FLEXIBILITY AND COMPATIBILITY IN SYSTEM
INTEGRATION
Flexibility in System Integration
Organic expansion
Easy management
Modular based architecture
Compatibility with 3
rd
party systems
Integrated central monitoring
4 reader control
Unlimited controller integration
12 inputs & 8 outputs (up to 28 & 24)
Fast Ethernet & Weigand
Global Anti-passback
AES/3DES encrypted communication
Web server embedded
Auto detects card formats
Supports HID products
Unlimited Clients
Unlimited access rights
100,000 users
256/256 Time schedules/holidays
Supports FP/Iris biometric readers
AES/3DES encrypted communication
Time-attendance & Meal management
Reporting tool
Supports Multiple languages
NO.
Use
Recommended Cable
Distance
Limit
1
Power supply IDentry-C4
Belden #9409, 18 AWG
2 conductor, unshielded
5m
2
Reader IDentry-C4
Belden #9512, 22 AWG
4 conductor, unshielded
100m
3
Input Device IDentry-C4
Belden #9512, 22 AWG
4 conductor, unshielded
100m
4
Output Device(Lock/alarm) IDentry-
C4
Belden #9409, 18 AWG
2 conductor, unshielded
100m
5
Network  IDentry-C4
UTP Cable CAT5(Category5)
No.
Name
Description
Screw hole
4 screw holes to fix the ACU board to its case
Power input Port
DC +12V max 2A (excluded reader and lock/alarm device power
source)
Reply output Port
Output port for lock or alarm devices Form-C Type (NO, COM,
NC)
RJ45
Ethernet port for communication with PC and among controllers
Reader port
Wiegand format reader port
2 state input ports
Input ports with 2 state of ON/OFF
4 state supervised
input ports
8 inputs monitoring Open loop, Shorted loop, Grounded loop an
d Line fault
LED output port
Output port for LED displaying power/ACU status/communicatio
n status (output current : 50mA)
Initialization switc
h
Switch to initialize ID/EVENT/network configuration/ other config
uration
Recommended Wire and Cables
IDentry-C4
Quick Manual
December 2015 Ver. 2
For the full version of this manual, please visit COMMAX online
www.commax.com > Customer > Manual and download full manuals for installation and users.
Access Control IDentry-C4 Installation Manual
http://www.commax.co.kr/boardnew/lib/downfile.php?db=TB_ENGLISH_manual&fnum=128
http://www.commax.co.kr/boardnew/lib/downfile.php?db=TB_ENGLISH_manual&fnum=131
*CAMS-C Free version covers up to 8 controllers, please feel free to contact us
identry@commax.com if you would like to purchase full version CAMS-C for more than
8 controllers.
Cable Connection
System Overview Diagram
Cable-Connection
1. Power Connection: Use +12V Power supply (TB21)
2. Reader port connection: It allows to use separated power source for readers (important!
Use common ground among of controller board power and of reader power)
3. Relay port connection (Form-C): In case of Power Fail SECURE Lock(left) and in case of
Power Fail SAFE Lock(right). It is recommended to connect diode on the side of output devices as shown in the above configuration to protect the control device from possible damage by reversed power current from Lock or alarm devices.
4. Two state input port connection: 2 stated input ports to monitor controller box status
of AC FAIL, LOW BATTERY, TAMPER ALARM and more NO/NC option.