Commax DRC-GAC, DRC-GAB User Manual

Page 1
Thank you for purchasing COMMAX products.
Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow
instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.
Thank you for purchasing COMMAX products.
Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow
instructions to use a product exactly.
Lobby camera phone DRC-GAC/GAB
User Manual
- Feature -
Covers all building with UPT cable.
RF/ID (function optional)
Page 2
- 1-
the Main Entrance Interphone
(RF/ID) - Optional
9. Electronic key setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
10. Door Release Time Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
11. Line call Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
12. Paging Signal Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
13. The number of emitting chime setup . . . . . . . . . . . . . . . . . . . . . . . . .24
14. Video Out Impedance Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . .25
15. Input Household number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
16. Household Number Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
17. Paging the Household . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
18. Door Release Using the Household PIN . . . . . . . . . . . . . . . . . . . . . .29
19. Door Release Using the Building (Management) PIN . . . . . . . . . . . .29
20. Appendix (Various Program Summaries) . . . . . . . . . . . . . . . . . . . . . .30
21. How to use lobby phone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
22. Wiring Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
22. Mscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
23. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Table of Contents
Thank you for purchasing a Commax product.
This product is a high tech Main Entrance interphone that supports electronic and remote (Optional) keys features. Please read this manual carefully and familiarize yourself with it before use.
1. Greetings
7. Configuring Serial Numbers in . . . . . .13 .
1.Greeting
2.Warning for safety
3.Overview
4. PIN Types
5. Setting PIN
6. Household PIN Confirmation
8. Using Remote Cardkeys
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 . . .
Page 3
Please follow the things described below in order to prevent any danger or property damage.
Warning
Caution
P
rohibition.
No disassembly
N
o touch
M
ust follow strictly.
Shows plugging out the power cord without an exception
Shows the warning and caution for an electric shock.
Shows the warning and caution for a fire.
It may cause a serious damage or i
njury if violated.
It may cause a minor damage or i
njury if violated.
Power & Installation
Warning
Please don’t use several products at the same time on one power socket.
·
It may cause a fire due to an abnormal overheating.
Please don
t bend the power cable excessively or it may cause an electric shock.
·
fire when using a damaged power cable.
Please don
t handle the power
cable with a wet hand.
·
It may cause an electric shock.
Please plug out the power cable from the socket when not using it for a long period of time.
·
It may shorten the product lifespan or cause a fire.
Please don
t install the product in the place where there is much oil, smoke or humidity.
·
It may cause an electric shock or fire.
Please don
t install the product with the lightening and thunder.
·
It may cause an electric shock or fire.
Please don
t use and connect this product with other products with different rated voltage
·
It may cause a disorder or fire.
When installing the product that generates heat, please install the product away from the wall (10cm) for the ventilation.
·
It may cause a fire due to the increased internal temperature.
2. Warning for safety
- 2-
Page 4
- 3-
Cleaning & Use
P
lease dontdisassemble,
r
epair or rebuild this product
a
rbitrarily (please contact the service center if a repair is needed.
·
It may cause an electric s
hock or fire.
P
lease plug the power cable f
irmly into the inner end
·
It may cause a fire.
P
lease hold the plug tightly
w
hen unplugging the power cable (a part of the copper wire may be disconnected if the grabbing is only made on the cord when pulling out the cable).
·
It may cause an electric shock or fire
W
hen connecting the power
c
ables after cutting the cable, please install the product with power off
·
It may cause an electric shock or fire
W
hen installing the product,
p
lease fix it firmly while using the wall-mounting unit and screws.
·It may cause an injury from
the falling object.
Please be careful when using an AC circuit breaker since there is a possibility of an electric shock.
When cleaning the product, please rub it with a soft and dry cloth after plugging out the power cable. (Please don
t use any chemical products such as wax, benzene, alcohol or cleanser.)
Please don
t drop the product
on the ground and don
t apply
a shock .
·
It may cause a failure.
Please use the designated connection cable within the maximum calling distance designated for the product
·
It may reduce the product performance.
Please check the use voltage and current for the DC-only products and use the appropriate rectifier.
·
It may cause a fire.
Please avoid direct rays of the sun or heating devices at a time of installation.
·
It may cause a fire.
Please don
t install the product on an unstable place or small support board.
·
It may cause an injury if it falls down while in use.
If an abnormal sound, burning smell or smoke is coming out o
f the product, please plug out
t
he power cable and contact a
s
ervice center.
·
It may cause an electric shock or fire.
P
lease don
t
insert any
m
etallic or burnable materials
i
nto the ventilation hole.
·
It may cause an electric shock or fire.
Please use only the designated batteries for the products of using DC power.
·
I
t may cause an electric
s
hock or fire.
Cleaning & UsePower & Installation
Warning
Caution
Page 5
- 4 -
3-1. Part name
① ②
③ ④ ⑤
⑬ ⑭
3. Overview
No FUN No FUN
1. C-MIC
2. CAMERA
3. SPEAKER
4. FND DISPLAY
5. RF-ID
6. PROGRAM BUTTON
7. GUARD BUTTON
8. INPUT BUTTON
9. ELETRONIC KEY BUTTON
10.
CANCEL BUTTON
11. CAMERA ANGLE
12. AJUSTMENT BUTTON
13.
TALK VOLUME CONTROLLER
14. RESET SWITCH
Page 6
- 5-
3-2 Essentials
RF/ID Receiver (Optional)
To open the door using a Remote Cardkey, place the key here. The word ‘oPEn’will display and the door will be released.
Call Button (E: Enter)
This button is used to page households.
Program Button (P: Program )
This button is used to Program.
Electronic Key Button (K: Key)
This button is used to release the door by using PIN. (Available only when the Electronic Key option has been set as OFF. When it is set as
ON, Finger Print Recognition is enabled)
Guard callt button (G: Guard)
This function is to call the guard house
Press the Page button after entering the Household Number.
Please the Card Here
OPEN DOOR
Program Enter
Page 7
- 6-
Cancel Button ⑪ (X: Cancel)
This button is used to cancel the current operation.
Talk volume controller
Talk volume is adjustable by switching the controller to Low or High
Reset Button
This button is used to reset the Building PIN or the Management PIN
Change the message on FND
To change the message on FND, press the Program button (P) for 5 seconds.
1) Displaying system version
0101-9901 SLI DRC-GAC Ver.01
2) Displaying general message
hELLo hAPPy dAy
If the Management PIN can not be remembered, press the Reset button
To Lower the Volume To Raise the Volume
Page 8
- 7-
Must Know Before Use!
1) Accessing All Features with the Program Button
-When an error has been made as indicated by continuous beeps, please cancel and start again from the beginning.
2) Forgotten PIN
2-1. Household PIN
Use the Household PIN verification feature of 6-1 to retrieve the PIN. (Please inquire to the Guardhouse or the Management Office)
2-2. Building PIN
Reenter using the Management PIN.
2-3. Management PIN
Press the Reset button. Both the Building and the Management Building PINs are reset to default.
3) All Remote Cardkey Deletion of 8-3 is to be used only when the unit is being initially installed.
4) Configuration Mode Indications
Configured features are displayed on the Display Window when the Main Entrance interphone is not in use.
Beep-Beep-Beep
(Error)
Start again from the beginning
Series
Door status
Version No.
Camera Impedance
Serial Number
Building Number
0101-990 S-LI DRC-GAC Ver01 Open
Page 9
- 8-
4. PIN Types
4-1. Management PIN
- This PIN is for use by the person in charge of the Management Office.
- By default, this PIN is set as 4321.
- Management PIN shall be stated as “Management PIN” here below
4-2. Building PIN
- This is the common PIN for each main entrance.
- By default, this PIN is set as 1234.
- Management PIN shall be stated as “Building PIN” here below
4-2. Household PIN
- Each household has its own PIN.
- By default, this PIN is set as 1234.
- For convenience, hereafter household PIN.
<Reference>
Old PIN
Default Management PIN: 4321
Default Building PIN: 1234
Default Household PIN: 1234
New PIN
New PIN to be set by the user.
P : Program K : Electronic Key E : Call
Page 10
- 9-
5. Setting PIN
5-1. Management PIN Setup
P - Old Management PIN - E - 0 - E - New PIN -EManagement PIN must be 4-digits long.0000 will not be recognized as a valid PIN.
Press the Program button (P). (‘Progwill appear)Enter the old PIN 4321.Press the Call button (E).Press the Program Number 0.Press the Call button (E). (‘PASSwill blink)Enter the new PIN.Press the Call button (E).Management PIN has been updated.
Press the Program button (P).
Enter the old PIN 4321.
Press the
Call button (E).
Press the Program Number 0.
Press the
Call button (E).
Press the Call button (E).
Management PIN has been updated.
Enter the new PIN. ex)1470
<Note>
Be sure to change managing password ahead of use
Page 11
- 10 -
5-2. Building PIN Setup
P - Old Management PIN - E - 1 - E - New PIN - EBuilding PIN must be 4-digits long.
0000 will not be recognized as a valid PIN.
Press the Program button (P). (‘Progwill appear)Enter the old PIN 4321.Press the Call button (E).Press the Program Number 1..Press the Call button (E). (‘PASSwill blink)Enter the new PIN.
Press the Call button (E).
Building PIN has been updated
Press the Program button (P).
Enter the old PIN 1234.
Press the
Call button (E).
Press the Program Number (1).
Press the
Call button (E).
Press the Call button (E).
Building PIN has been updated.
Enter the new PIN. ex)2580
Page 12
- 11 -
5-3. Household PIN Setup
K - Program Number - E - Household Number - E - Old Household PIN - E - New PIN - P
Household PIN must be 4-digits long.0000 will not be recognized as a valid PIN.
This method of Household PIN change may vary depending on household interphone types.
(Types that support PIN changing from the household interphone)
Press the Electronic Key button (K).
Press the Program Number 20.
Press the Call button (E). (honowill blink)Enter the Household Number.Press the Call button (E). (‘PASSwill blink)
Enter the old Household PIN.
Press the Call button (E). (PASSwill blink)Enter the new Household PIN
Press the Program button (P).
Household PIN has been updated.
Press the Program button (P).
Press the
Call button (E).
Electronic Key button (K).
Press the Program Number (20).
Enter the old PIN. ex)1234
Enter the new Household PIN.
ex)3690
Household Number. ex) 101
Press the
Call button (E).
Press the
Call button (E).
Page 13
- 12 -
6.Household PIN Confirmation
6-1. Household PIN Confirmation
P - Management PIN - E - Program Number - E - Household Number - E
Press the Program button. (‘Progwill appear)Enter the Management PIN.Press the Call button (E).Press the Program Number (16).Press the Call button (E). (‘honowill blink)Enter the Household Number. (The Household Number will be indicated)Press the Call button (E). (The Household PIN will be indicated)
Press the Program button (P).
Enter the Management PIN.
Press the
Call button (E).
Press the
Program Number (16).
Press the
Call button (E).
Press the Call button (E).
ex)1 2 3 4 for household 101
Household Number. ex) 101
Page 14
- 13-
Press the Program button (P). (‘Progwill appear)Enter the Management PIN.Press the Call button (E).Press the Program Number (3) .Press the Call button (E). (The Serial Number previously entered will be indicated)Enter the new Serial Number.Press the Call button
Serial Number has been updated.
P
ress the Program button (P).
Enter the Management PIN.
P
ress the
C
all button (E).
Press the
Program Number (3).
Press the
Call button (E).
The Serial Number previously
entered will be indicated
Press the Call button (E).
Serial Number has been updated.
Enter the New Serial Number ex) No. 2
7.
Configuring Serial Numbers in the Main Entrance Interphone
P - Management PIN - E - 3 - E - Serial Number - E
Page 15
- 14-
8. Using Remote Cardkeys (RF/ID) - Optional
8-1. Testing Remote Cardkeys
P - Management PIN - E - 9 - E - Card Test - X (Cancel)This feature is used to test Remote Cardkeys.
Press the Program button (P). (‘Progwill appear)Enter the Management PIN.Press the Call button (E).
Press number 9 (Remote Cardkey Test).
Press the Call button. (Cdttwill blink)
Place the Remote Cardkey to the RF/ID Receptor, and the Card Number will appear on
the Display Window (FND).
Press the Cancel button (X) to end Remote Cardkey testing.
Press the Program button (P).
Enter the Management PIN.
Press the
Call button (E).
Press the
Program Number (9).
Press the
Call button (E).
Press the Cancel button (X) to end Remote Cardkey testing
Press the Card Here
ex) Card Number 3579
Place the Remote Cardkey to the RF/ID Receptor, and the Card Number will appear on the Display Window (FND).
To confirm others cardkey, place continuedly the Remote Cardkey to the RF/ID Recepter
Page 16
- 15-
8-2. Remote Cardkey Registration
P - Management PIN - E - 10 - E - Card Registration - X (Cancel)
<Note>
CdSv: Newly Registered Card (Successful registration is indicated by a beep)
CdAl: Previously Registered Card (Rejected registration is indicated by two beeps)
Up to 2048 Remote Cardkeys can be registered. (Without a computer connected)
Please record registered Remote Cardkey’s serial number for future reference.
CdFu : Exceeding card storage limit (If you didn't register a card, please delete all
saved card referring to 8-5 chapter)
<Caution>
Do not turn off the products within ten seconds after registering RF cards. It might
cause a problem in saving RF cards information.
Press the Program button (P).
Enter the Management PIN.
P
ress the
Call button (E).
Press the
Program Number (10).
Press the
Call button (E).
Press the Cancel button (X) to end Remote Cardkey testing
To confirm others cardkey, place continuedly the Remote Cardkey to the RF/ID Recepter
Newly
Registered Card
Previously
Registered Card
Press the Card Here
Place the Remote Cardkey to the RF/ID Receptor, and ‘Cdsv’ or ‘CdAL’ will appear
4 3 2
1
Page 17
- 16-
8-3. Individual Deletion of Remote Cardkeys
P - Management PIN - E - 12 - E - Card Deletion - X (Cancel)
Press the Program button (P). (‘Progwill appear)
Enter the Management PIN.
Press the Call button (E).
Press number 12 (Individual Remote Cardkey Deletion).
Press the Call button (E). (CddEwill blink)
Enter the 5-digit Card Number and press the Call button (E). (Check on the right side of the RF/ID Card) Or place the Card on top of the RF/ID Receiver.
Press the Cancel button (X) to terminate the feature
Press the Program button (P).
Enter Management PIN.
P
ress the
Call button (E).
Press the
Program Number (12).
Press the
Call button (E).
Press the Cancel button (X) to terminate the feature
Press the Card Here
1. Place the Card on top of the RF/ID Receiver, and will delete Card Number
2. Enter Card Number and press Call button, and will delete Card Number
ex) Card Number
19919
ex) For Card Number 19919 delete
4 3 2
1
Page 18
- 17-
8-4. Confirming Remote Cardkey Registration
P - Management PIN - E - 13 - E - Card Confirmation - X (Cancel)
Press the Program button (P). (‘Progwill appear)Enter the Management PIN.Press the Call button (E).Enter number 13 (Remote Cardkey Confirmation).
Press the Call button (E). (CddEwill blink)
Enter the 5-digit Card Number and press the Call button (E). (Check the right side of the RF/ID Card) Or place the Card on top of the RF/ID Receiver.
Press the Cancel button (X) to terminate the feature.
P
ress the Program button (P).
Enter the Management PIN.
P
ress the
C
all button (E).
Press the
Call button (E).
Press the
Program Number (13).
Press the Cancel button (X) to terminate the feature
Press the Card Here
1. Place the Card on top of the RF/ID Receiver, and will confirm.
2. Enter Card Number and press Call button, and will confirm Remote Cardkey Registration.
ex) Card Number
19919
Confirm Card
No Confirm Card
ex) For Card Number 19919 Confirm
4
3
2
1
Page 19
- 18-
8-5. All Remote Cardkey deletion
P - Management PIN - E - 11 - E - ERefrain from deleting all Remote Cardkeys, except for during installation.
Press the Program button (P). (‘Progwill appear)Enter the Management PIN.Press the Call button (E).Enter number 11 (All Remote Cardkey Delete Number).Press the Call button (E). (‘dELwill blink)
Press the Call button (E) again.
The number displayed on screen will change.
Press the Cancel button (X) to terminate the feature.
Press the Program button (P).
Enter the Management PIN.
Press the
Call button (E).
Press the
Call button (E).
All Remote Cardkey mode All Remote Cardkey mode
Press the
Call button (E).
Press the
Program Number (11).
<Note>
In order to delete all registered RF cards, Move to "Program 23" "Mode 1"
and execute "Delete all registered RF cards" with in 30 seconds.
4 3 2
1
Page 20
- 19-
9. Electronic key setting
P - Management PIN - E - 8 - E - 0 – E : Deactivate usage of electronic keys (
Available PIN number access)
P - Management PIN - E - 8 - E - E - : Deactivate usage of electronic keys Door ( Not available PIN access)
This feature is for deactivating or activating the use of electronic keys in door access .
Press the Program button (P). (‘Prog’ will appear)
Enter the Management PIN.
Press the Call button (E). Enter number 8 ( Monitor setting number for surveillance). Press the Call button (E). (Displaying previous setting on the screen)
Select a mode. (0 : Activate electronic key use) (1 : Deactivate electronic key use)
Press the Call button (E) again. (Modification updated)
Press the Program button (P).
Enter the Management PIN.
Press the
Call button (E).
Press the
Call button (E).
Call button (E).
Press the Program Number (4).
Deactivate electronic key
Activate electronic key
Completion of activating electronic key
Previous selection is displayed
Page 21
- 20-
10. Door Release Time Setup
P - Management PIN - E - 4 - E - Door Release Time - E
This feature adjusts the door release time.
Press the Program button (P). (‘Progwill appear)Enter the Management PINPress the Call button (E).Press number 4 (Door Release Time Setup).Press the Call button (E). (Previous selection is displayed)Choose a time. (From 1 to 25 seconds)
Use numbers from 1 to 25.
Press the Call button (E). (Modification updated)
Press the Program button (P).
Enter the Management PIN.
Press the
Call button (E).
The current capacity is displayed.
Press the
Call button (E).
Press the
Call button (E).
Press the Program Number (5).
Choose a time.
Use numbers from 1 to 25.
Modification updated
ex) Door Release time
Selected 10 seconds
4
3
2
1
Page 22
11. Line Call Setup
P - Management PIN - E - 21 - E - 0 - E : All calls
P - Management PIN - E - 21 - E – 0103 - E : Line call ex) This function is for calling
to specified line like from 1sthouse line to 3rdhouse line. .
Modification updated
Press the Call button (E).
Ex ) Call the 1ST Line to 3 Line
Enter the Line.st
Press the Program Number (21).
Press the Call button (E).
Previous selection is displayed
Press the Call button (E).
Enter the Management) PIN.
Press the Program button (P).
Press the Program button (P). (‘Progwill appear)
Enter the Management PIN.
Press the Call button (E).
Press number 21
Press the Call button (E). (Previous selection is displayed)
Choose a line you want to call
ex) In case of calling to 1sthouse to 3
rd
house line, input “0103”
Press the Call button (E). (Modification updated)
- 21-
Page 23
- 22-
P - Management PIN - E - 5 - E - 0 - E: Melody Tone
P - Management PIN - E - 5 - E - 1 - E: Bell (Ringer)
This feature sets the Recall tone heard when Households or the Guardhouse is paged from the Main Entrance.
Press the Program button (P). (‘Progwill appear)
Enter the Building (Management) PIN.
Press the Call button (E).
Press number 5 (Page Signal Selection).
Press the Call button (E). (Previous selection is displayed)
Select a page signal.
0 : Melody Tone1 : Bell (Ringer)
Press the Call button (E). (Page signal updated)
12. Page Signal Selection
Press the Program button (P).
Enter the Building (Management) PIN.
ex) Building PIN
Press the
Call button (E).
The current capacity is displayed.
Press the
Call button (E).
Press the
Call button (E).
Press the Program Number (7).
Input line
0: Melody Tone 1: BELL Tone(RINGER)
4
3
2
1
Page 24
- 23-
P - Management PIN - E - 7 - E - 0 - E: Constant call
P - Management PIN - E - 7 - E - 1 - E: Call once
This function is to set the call sound when make a call to household or guard station from the lobby.
Press the Program button (P). (‘Progwill appear)
Enter the Management PIN.
Press the Call button (E).
Press number 7 (Wiring Method Selection).
Press the Call button (E). (Previous selection is displayed)
Select a wiring method.
0 : 0 : Melody
1: Bell (Ringer)
Press the Call button (E). (Save new setting)
13. The number of emitting chime setup
Press the Program button (P).
Enter the Building (Management) PIN.
ex) Building PIN
Press the
Call button (E).
The current capacity is displayed.
Press the
Call button (E).
Press the
Call button (E).
Press the Program Number (6).
Choose a mode
0: Constant call 1: Call once
Completion of setup
ex) Setting for calling once
4
3
2
1
1
Page 25
- 24-
Press the Program button (P).
Enter the Management PIN.
Press the
Call button (E).
The current capacity is displayed.
Press the
Call button (E).
Press the
Call button (E).
Press the Program Number (8).
Select the Impedance
0: Short Distance 1: Long Distance
Impedance selection updated
ex) Impedance Adjusted
short distance
P - Building (Management) PIN - E - 6 - E - 0 - E: Short Distance
P - Building (Management) PIN - E - 6 - E - 1 - E: Long Distance
By default, the unit is set for short distance. Do not change if possible.
Press the Program button (P). (‘Progwill appear)
Enter the Building (Management) PIN.
Press the Call button (E).
Press number 7 (Wiring Method Selection).
Press the Call button (E). (Previous selection is displayed)
Select a wiring method.
0 : 0 : Melody
1: Bell (Ringer)
Press the Call button (E). (Save new setting)
14. Video Out Impedance Adjustment
4
3
2
1
Page 26
- 25-
15. Input Household number
P - Management PIN - E - 15 - E - Household Number - E-Multi Sub number - E This function is for inputting household number with lobby phone in case of a guard
station unit is not installed
Press the Program button (P).
Enter the Management PIN.
Press the
Call button (E).
Household PIN Entry Mode
Press the
Call button (E).
Press the
Call button (E).
Press the
Call button (E).
Press the Program Number (15).
Lift up the receiver from the Household and press the Guard button to page the Main Entrance Interphone, where the Household Number will be displayed. (Then, the displayed number must be changed for it is the default number from the factory.)
Enter the Household number and press the Page button (E).
ex) Entering as first
1234
ex) Entering as Unit 101
Enter the Multi Sub number and press the Page button (E).
Follow the same procedure to enter other Households. Press the Cancel button (X) to end.
ex) Entering as Master
4
3
2
1
Page 27
- 26-
<Multi sub number>
What is Multi sub number?
In case that one household have more than one unit, assigned number to identify
every unit for proper communication.
Master
assigned as “O”
Sub Serial Numbers are from 1 to 9.
Maximum 10 videophones can be installed in a household, and their serial
numbers must not overlap.
Assign sub number from 1 to 9 order.
A Master must exist among numerous videophones. If only one videophone
exists, that unit shall be registered as the Master.
Press the Program button (P). (‘Prog’ will appear) Enter the Management PIN. Press the Page button (E). Enter number 15 (Household Interphone Diagnosis). ⑤ ⑥ Call to guard station from household The Household’s status is shown on the display window (FND). Household Number, then press the Page button (E).
(‘sub’ will appear)
Input Multi sub number, then press the Call button (E). To check other Households, repeat steps 6 ~ 9.
Press the Cancel button (X) to terminate the feature.
Press the Page button (E). (‘idCh’ will appear)
Page 28
- 27-
Enter theHousehold Number.
Press the Guard button. Press the Page button.
A paging tone will sound.
Wait for a reply
Wait for a reply
Press the page button. A paging tone will sound.
Press the
Call button (E).
Press the
Call button (E).
ex) unit 101
16. Paging the Household
17. Paging the Guardhouse
Page 29
- 28-
Household Number - K - Household PIN - E
O - K - Building (Management) PIN - E
Enter the Household Number.
Press the Guard button.
Enter the Household PIN. Press the Page button.
Press the Page button.
Enter the Building or the
Management PIN.
Press the Electronic key button.
Press the Electronic key button.
Press the Call button (E).
Press the Call button (E).
ex) To open the door of unit 101
18. Door Release Using the Household PIN
19. Door Release Using the Building (Management) PIN
Page 30
- 29-
Various PIN Programs
1. P - Old Management PIN - E - 0 - E - New PIN- E: Management PIN Change
2. P- Old Management PIN -E -1 - E - New PIN - E: Building PIN Change
3. K - 20 - E - Household Number - E - Old Household PIN - E - New PIN - P: Household PIN Change
4. P - Management PIN - E - 16 - E - Household Number - E: Household PIN Confirmation
Configuring Building and Serial Numbers from the Main Entrance Interphone
1. P - Management PIN - E - 2 - E - Building Number - E: Building Number Setup
2. P - Management PIN - E - 3 - E - Serial Number - E: Serial Number Setup
Remote Cardkey Programs
1. P - Management PIN - E - 9 - E: Remote Cardkey Test
2. P - Management PIN - E - 10 - E: Remote Cardkey Registration
3. P - Management PIN - E - 11 - E: All Remote Cardkey Delete (Household PIN Delete)
4. P - Management PIN - E - 12 - E: Individual Cardkey Delete
5. P - Management PIN - E - 13 - E: Remote Cardkey Confirmation
Door Release Using Various PINs
1.GP - KP - Building (Management) PINP - E: Door release using Building (Management) PIN
2.Household NumberP - KP - Household PINP - E: Door release using Household PIN
Other Feature Setup Methods
1.P - Management PIN - E - 4 - E: Surveillance Monitor Setup
2.P - Management PIN - E - 5 - E: Door Release Time Setup
3.P - Management PIN - E - 6 - E: Wiring Method Selection
4.P - Management PIN - E - 15 - E: Household Number Registration
20. Appendix (Various Program Summaries)
Page 31
- 30-
Calling to household from lobby phone
Household number – E
Press the household number Press the Call button.
ex)In case of household 101 Emit call sounds
Opening door with household PIN
Household number – K – household PIN – E
Press the household number
Press the Household PIN Press the Call button
Press the Key button
ex) In case of household 101
21. How to use lobby phone.
Page 32
22. Wiring Method
1) Lobby camera phone(DRC-GAC/GAB)
- 31-
Page 33
2) System Schematic
- 32-
Page 34
3) Terminal Board Wiring Diagram
- 33-
Page 35
3) DRC-GAC Expansion
- 34-
Page 36
Please carefully read this User’s Guide before calling service man After checking the entire check list, please contact customer service center. We will do our best to make you satisfy with our services.
Installation Method Flush mounted type Model Name DRC-GAC / DRC-GAB Transmission System Household (8 wires), Guard (4 wires) Power source DC 12V/0.5A Power consumption Standby: 200mA, Max: 500mA Conversation Hands-free Lens B/W C.C.D 1/3", Color CCD 1/4" Frequency 15.735KHz, 60Hz / 15.625KHz, 50Hz Camera angle Horizon: 68℃, Vertical: 55℃ Minimum Illumination 0.1Lux ( within 300mm from the camera) Distance UPT cable: 300meter Built-in light LED Temperature, Humidity -10℃ ~ +50℃, 95% Dimension 124.6(W) X 317.2(H) X 59.7(D)mm
Model DRC-GAC/RF Frequency 13.56Mhz
Less than47.544mV/m at 10M Frequency type A1D Modulation system ASK Communication system One-way Operating distance 30mm
RF-ID wireless module (optional)
23. Miscellaneous
24. Specifications
- 35-
Page 37
513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int’l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com
Printed In Korea / 2010.09.103
Loading...