15. Household Number Registration ⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 30
16. Paging the Household ⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 32
17. Paging the Guardhouse ⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 32
18. Door Release Using the Household PIN⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 33
19. Door Release Using the Building (Management) PIN⋯⋯⋯⋯ 33
20. Appendix (Various Program Summaries) ⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 34
21. Wiring Method ⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 36
22. Specifications ⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 51
⋯⋯ 15
Class-B
Product
Instructions for Users
This Product, which has been registered for the home
service, can be used in all the areas including the
household area.
- 1-
Page 3
Safety Warning & Caution
Please follow the things described below in order to prevent any
danger or property damage.
Prohibition.
Warning
Caution
It may cause a serious damage or
injury if violated.
It may cause a minor damage or
injury if violated.
No disassembly
No touch
Must follow strictly.
Shows plugging out the power cord
without an exception
Shows the warning and caution for an electric shock.
Shows the warning and caution for a fire.
Warning
Please don’t use several
products at the same time on
one power socket.
·It may cause a fire due to an
abnormal overheating.
Please don’t install the
product in the place where
there is much oil, smoke or
humidity.
·It may cause an electric
shock or fire.
Power&Installation
Please don’t bend the power
cable excessively or it may
cause an electric shock.
·fire when using a damaged
power cable.
Please don’t install the
product with the lightening
and thunder.
·It may cause an electric
shock or fire.
Please don’t handle the power
cable with a wet hand.
·It may cause an electric
shock.
Please don’t use and connect
this product with other
products with different rated
voltage
·It may cause a disorder or
fire.
Please plug out the power
cable from the socket when
not using it for a long period
of time.
·It may shorten the product
lifespan or cause a fire.
When installing the product
that generates heat, please
install the product away from
the wall (10cm) for the
ventilation.
·It may cause a fire due to
the increased internal
temperature.
- 2-
Page 4
Warning
Please don’t disassemble,
repair or rebuild this product
arbitrarily (please contact the
service center if a repair is
needed.
·It may cause an electric
shock or fire.
Cleaning & UsePower&Installation
Please plug the power cable
firmly into the inner end
·It may cause a fire.
Please be careful when using
an AC circuit breaker since
there is a possibility of an
electric shock.
If an abnormal sound, burning
smell or smoke is coming out
of the product, please plug out
the power cable and contact a
service center.
·It may cause an electric
shock or fire.
Caution
Please hold the plug tightly
when unplugging the power
cable (a part of the copper
wire may be disconnected if
the grabbing is only made on
the cord when pulling out the
cable).
·It may cause an electric
shock or fire
Please check the use voltage
and current for the DC-only
products and use the
appropriate rectifier.
·It may cause a fire.
Please don’ t insert any
metallic or burnable materials
into the ventilation hole.
·It may cause an electric
shock or fire.
When connecting the power
cables after cutting the cable,
please install the product with
power off
·It may cause an electric
shock or fire
Please avoid direct rays of the
sun or heating devices at a
time of installation.
·It may cause a fire.
Please use only the designated
batteries for the products of
using DC power.
·It may cause an electric
shock or fire.
When installing the product,
please fix it firmly while using
the wall-mounting unit and
screws.
·It may cause an injury from
the falling object.
Please don’t install the
product on an unstable place
or small support board.
·It may cause an injury if it
falls down while in use.
When cleaning the product,
please rub it with a soft and
dry cloth after plugging out
the power cable. (Please don’t
use any chemical products
such as wax, benzene, alcohol
or cleanser.)
Cleaning & Use
Please don’t drop the product
on the ground and don’t apply
a shock .
·It may cause a failure.
Please use the designated
connection cable within the
maximum calling distance
designated for the product
·It may reduce the product
performance.
- 3-
Page 5
1. Greetings
Thank you for purchasing a Commax product.
This product is a high tech Main Entrance interphone that supports
electronic and remote (Optional) keys and finger print recognition
(Optional) features. Please read this manual carefully.
2. Before Getting Started
Using 8-wire common wiring method between the Main Entrance interphone and
the Guardhouse interphone, this system supports 3 communication circuits, and
each communication circuit is a Balance Type that supports 2 wires.
Using 4-wire common wiring method between the Main Entrance interphone and
the Household interphone, this system supports telephone and video
connections. Only use coaxial cables for video connection.
The short and cut of wiring can cause a malfunction. Be sure to check wiring
before installation.
It is recommended that each Main Entrance interphone is installed and its
connection be checked from the Guardhouse and the Household(s).
Maximum of 2048 Remote Cardkeys are supported. (When not connected to a
computer)
Three consecutive entries of wrong Management PIN, Building PIN, or
Household PIN will automatically page the Guardhouse.
Three consecutive attempts at unlocking doors with an unregistered Remote
Cardkey will also automatically page the Guardhouse.
※ Remarks
- 4-
Page 6
3. Overview
3-1. Feature
DRC-481L
No
1
2
3
4
5
6
7
8
9
Description
Display Window (FND)
RF/ID Receiver (Optional)
Speaker
Mic
Key Pad
Call Button
CCD Camera
Program Button
Electronic Key Button
To open the door using a Remote Cardkey, place the key here. The word ‘oPEn’will
display and the door will be released.
Audio Guide
“Door Opened”
Please the Card Here
✽ Call Button (E: Enter)
This button is used to page households.
OPEN DOOR
Press the Page button after entering
the Household Number.
✽ Program Button (P: Program )
This button is used to Program.
Program Enter
✽ Electronic Key Button (K: Key)
This button is used to release the door by using PIN.
(Available only when the Electronic Key option has been set as OFF. When it is set as
ON, Finger Print Recognition is enabled)
✽ Guardhouse Page Button (G: Guard)
This button is used to page the Guardhouse if the Guardhouse interphone has been
installed.
- 7-
Page 9
✽ Cancel Button (X: Cancel)
This button is used to cancel the current operation.
Audio Guide
“Cancelled”
✽ Selection Switches
No. 1: Computer Connection Switch (Used for connection with a computer)
Connects a computer using network exclusive to DRC-481L.
OFF : To connect to a computer via the RS-485 Port with Finger Print Recognition in use.
ON : To connect to a computer via an internal network without Finger Print Recognition in
✽ P - Old Management PIN - E - 0 - E - New PIN -E
✽ Management PIN must be 4-digits long.
✽ 0000 will not be recognized as a valid PIN.
Press the Program button (P).
Press the Program Number 0.
Enter the old PIN 4321.
Press the
Call button (E).
Enter the new PIN. ex)1470
Management PIN has been updated.
Press the Call button (E).
① Press the Program button (P). (‘Prog’will appear)
② Enter the old PIN 4321.
③ Press the Call button (E).
④ Press the Program Number 0.
⑤ Press the Call button (E). (‘PASS’will blink)
⑥ Enter the new PIN.
⑦ Press the Call button (E).
⑧ Management PIN has been updated.
Press the
Call button (E).
- 11-
Page 13
5-2. Building PIN Setup
✽ P - Old Building PIN - E - 1 - E - New PIN - E
✽ Building PIN must be 4-digits long.
✽ 0000 will not be recognized as a valid PIN.
Press the Program button (P).
Press the Program Number (1).
Enter the old PIN 1234.
Press the
Call button (E).
Building PIN has been updated.
Press the Call button (E).
① Press the Program button (P). (‘Prog’will appear)
② Enter the old PIN 1234.
③ Press the Call button (E).
④ Press the Program Number 1..
⑤ Press the Call button (E). (‘PASS’will blink)
⑥ Enter the new PIN.
⑦ Press the Call button (E).
⑧ Building PIN has been updated
Press the
Call button (E).
Enter the new PIN. ex)2580
- 12-
Page 14
5-3. Household PIN Setup
✽
K - Program Number - E - Household Number - E - Old Household PIN - E - New PIN - P
✽ Household PIN must be 4-digits long.
✽ 0000 will not be recognized as a valid PIN.
✽
This method of Household PIN change may vary depending on household interphone types.
(Types that support PIN changing from the household interphone)
Electronic Key button (K).
Household Number. ex) 101
Press the
Call button (E).
Press the Program Number (20).
Press the
Call button (E).
Enter the new Household PIN.
ex)3690
① Press the Electronic Key button (K).
② Press the Program Number 20.
③ Press the Call button (E). (‘hono’will blink)
④ Enter the Household Number.
⑤ Press the Call button (E). (‘PASS’will blink)
⑥ Enter the old Household PIN.
⑦ Press the Call button (E). (‘PASS’will blink)
⑧ Enter the new Household PIN
⑨ Press the Program button (P).
Household PIN has been updated.
Press the
Call button (E).
Enter the old PIN. ex)1234
Press the Program button (P).
- 13-
Page 15
6.Household PIN Confirmation
6-1. Household PIN Confirmation
✽ P - Building (Management) PIN - E - Program Number - E - Household Number - E
Press the Program button (P).
Press the
Program Number (16).
Enter the Building (Management) PIN.
Press the
Call button (E).
Household Number. ex) 101
Press the
Call button (E).
ex)1 2 3 4 for household 101
Press the Call button (E).
① Press the Program button. (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Press the Program Number (16).
⑤ Press the Call button (E). (‘hono’will blink)
⑥ Enter the Household Number. (The Household Number will be indicated)
⑦ Press the Call button (E). (The Household PIN will be indicated)
- 14-
Page 16
7.
Configuring Building and Serial Numbers in the Main Entrance Interphone
✽ This feature must be performed for it automatically configures Building and Serial
numbers when Households or the Guardhouse is paged from the Main Entrance.
✽ Up to 99 Main Entrance interphones can be installed per each building.
7-1. Configuring Building Number from the Main Entrance Interphone
✽ P - Building (Management) PIN - E - 2 - E - Building Number - E
Press the Program button (P).
Press the
Program Number (2).
Enter the Building (Management) PIN.
Press the
Call button (E).
The Building Number previously
entered will be indicated
ex) 1234 Building
Enter the New Building Number
Press the
Call button (E).
Building Number has been
updated.
Press the Call button (E).
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Press the Program Number (2).
⑤ Press the Call button (E). (The Building Number previously entered will be indicated)
⑥ Enter the new Building Number.
⑦ Press the Call button.
Building Number has been updated.
- 15-
Page 17
7-2. Configuring Serial Number from the Main Entrance Interphone
✽ P - Building (Management) PIN - E - 3 - E - Serial Number - E
Press the Program button (P).
Press the
Program Number (3).
Enter the Building (Management) PIN.
Press the
Call button (E).
The Serial Number previously
entered will be indicated
Enter the New Serial Number ex) No. 2
Press the
Call button (E).
Serial Number has been
updated.
Press the Call button (E).
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Press the Program Number (3) .
⑤ Press the Call button (E). (The Serial Number previously entered will be indicated)
⑥ Enter the new Serial Number.
⑦ Press the Call button
Serial Number has been updated.
- 16-
Page 18
8. Using Remote Cardkeys (RF/ID) - Optional
8-1. Testing Remote Cardkeys
✽ P - Building (Management) PIN - E - 9 - E - Card Test - X (Cancel)
✽ This feature is used to test Remote Cardkeys.
Press the Program button (P).
Press the
Program Number (9).
Press the Cancel button
(X) to end Remote
Cardkey testing
Enter the Building (Management) PIN.
Press the
Call button (E).
Press the Card Here
ex) Card Number 3579
Place the Remote Cardkey to the RF/ID
Receptor, and the Card Number will appear on
the Display Window (FND).
✽
To confirm others cardkey, place continuedly the
Remote Cardkey to the RF/ID Recepter
Press the
Call button (E).
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Press number 9 (Remote Cardkey Test).
⑤ Press the Call button. (‘Cdtt’will blink)
⑥ Place the Remote Cardkey to the RF/ID Receptor, and the Card Number will appear on
the Display Window (FND).
⑦ Press the Cancel button (X) to end Remote Cardkey testing.
- 17-
Page 19
8-2. Remote Cardkey Registration
✽ P - Building (Management) PIN - E - 10 - E - Card Registration - X (Cancel)
Press the Program button (P).
Press the
Program Number (10).
Enter the Building (Management) PIN.
Press the
Call button (E).
Press the Cancel button
(X) to end Remote
Cardkey testing
ex) Building PIN
Press the
Call button (E).
Press the Card Here
Place the Remote Cardkey to the RF/ID
Receptor, and ‘Cdsv’ or ‘CdAL’ will appear
Newly
Registered Card
Previously
Registered Card
✽
To confirm others cardkey, place continuedly the
Remote Cardkey to the RF/ID Recepter
<Note>
CdSv: Newly Registered Card (Successful registration is indicated by a beep)
CdAl: Previously Registered Card (Rejected registration is indicated by two beeps)
✽ Up to 2048 Remote Cardkeys can be registered. (Without a computer connected)
✽ Please record registered Remote Cardkey’s serial number for future reference.
- 18-
Page 20
8-3. Individual Deletion of Remote Cardkeys
✽ P - Building (Management) PIN - E - 12 - E - Card Deletion - X (Cancel)
Press the Program button (P).
Press the
Program Number (12).
Enter the Building (Management) PIN.
Press the
Call button (E).
Press the Cancel button
(X) to terminate the
feature
ex) Building PIN
1. Place the Card on top of the RF/ID Receiver, and
2. Enter Card Number and press Call button, and will
Press the Card Here
will delete Card Number
delete Card Number
ex) Card Number
ex) For Card Number 19919 delete
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Press number 12 (Individual Remote Cardkey Deletion).
⑤ Press the Call button (E). (‘CddE’will blink)
⑥ Enter the 5-digit Card Number and press the Call button (E).
(Check on the right side of the RF/ID Card)
Or place the Card on top of the RF/ID Receiver.
⑦ Press the Cancel button (X) to terminate the feature
Press the
Call button (E).
19919
- 19-
Page 21
8-4. Confirming Remote Cardkey Registration
✽ P - Building (Management) PIN - E - 13 - E - Card Confirmation - X (Cancel)
Press the Program button (P).
Press the
Program Number (13).
Press the
Call button (E).
Enter the Building (Management) PIN.
Press the Card Here
1. Place the Card on top of the RF/ID Receiver,
and will confirm.
2. Enter Card Number and press Call button,
and will confirm Remote Cardkey Registration.
ex) For Card Number 19919 Confirm
ex) Building PIN
ex) Card Number
19919
Press the Cancel button (X) to terminate
the feature
Press the
Call button (E).
Confirm Card
No
Confirm Card
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Enter number 13 (Remote Cardkey Confirmation).
⑤ Press the Call button (E). (‘CddE’will blink)
⑥ Enter the 5-digit Card Number and press the Call button (E).
(Check the right side of the RF/ID Card)
Or place the Card on top of the RF/ID Receiver.
⑥ Press the Cancel button (X) to terminate the feature.
- 20-
Page 22
8-5. All Remote Cardkey deletion
✽ P - Building (Management) PIN - E - 11 - E - E
✽ Refrain from deleting all Remote Cardkeys, except for during installation.
Press the Program button (P).
Press the
Program Number (11).
Enter the Building (Management) PIN.
All Remote Cardkey modeAll Remote Cardkey mode
ex) Building PIN
Press the
Call button (E).
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Enter number 11 (All Remote Cardkey Delete Number).
⑤ Press the Call button (E). (‘dEL’will blink)
⑥ Press the Call button (E) again.
The number displayed on screen will change.
⑦ Press the Cancel button (X) to terminate the feature.
Press the
Call button (E).
Press the
Call button (E).
- 21-
Page 23
8-6. Remote Cardkey Capacity Expansion
✽ P - Building (Management) PIN - E - 19 - E - 0 - E: Maximum 2048 Cards can be
registered.
✽ P - Building (Management) PIN - E - 10 - E - 1 - E: Unlimited number of Cards can be
registered. (This feature is only available when connected to a computer)
Press the Program button (P).
Press the Program Number (19).
Select the Card capacity.
ex) Unlimited
Enter the Building (Management) PIN.
ex) Building PIN
Call button (E).
Maximum 2048
Unlimited
Press the
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Enter number 19 (Remote Cardkey Capacity Change).
⑤ Press the Call button (E). (The current capacity is displayed)
⑥ Select the Card capacity.
(0: Maximum 2048)
(1: Unlimited)
⑦ Press the Call button (E). (Updated)
Press the
Call button (E).
The current capacity
is displayed.
Press the
Call button (E).
Updated
- 22-
Page 24
9. Surveillance Monitor Configuration
✽ P - Building (Management) PIN - E - 4 - E - 0 - E: Surveillance disabled.
✽ P - Building (Management) PIN - E - 4 - E - 1 - E: Surveillance enabled.
✽ This feature provides entrance surveillance of the Main Entrance to a separate
monitor by using the Camera from the Main Entrance Interphone.
Press the Program button (P).
Press the Program Number (4).
Choose a mode
ex) Surveillance Configurated
Enter the Building (Management) PIN.
ex) Building PIN
Press the
Call button (E).
Surveillance
monitor cannot
be installed
Surveillance
monitor can be
installed
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Press number 4 (Surveillance Monitor Configuration).
⑤ Press the Call button (E). (Previous selection is displayed)
⑥ Choose a mode.
(0: Surveillance monitor cannot be installed)
(1: Surveillance monitor can be installed)
⑦ Press the Call button (E). (Modification updated)
Press the
Call button (E).
Previous selection
is displayed
Press the
Call button (E).
Modification updated
- 23-
Page 25
10. Door Release Time Setup
✽ P - Building (Management) PIN - E - 5 - E - Door Release Time - E
✽ This feature adjusts the door release time.
Press the Program button (P).
Press the Program Number (5).
Choose a time.
Use numbers from 1 to 25.
ex) Door Release time
Selected 10 seconds
Enter the Building (Management) PIN.
ex) Building PIN
Call button (E).
Press the
Press the
Call button (E).
Modification updated
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Press number 5 (Door Release Time Setup).
⑤ Press the Call button (E). (Previous selection is displayed)
⑥ Choose a time. (From 1 to 25 seconds)
Use numbers from 1 to 25.
⑦ Press the Call button (E). (Modification updated)
Press the
Call button (E).
The current capacity
is displayed.
- 24-
Page 26
11. Page Tone Selection
✽ P - Building (Management) PIN - E - 7 - E - 0 - E: Melody Tone
✽ P - Building (Management) PIN - E - 7 - E - 1 - E: Bell (Ringer)
✽ This feature sets the Recall tone heard when Households or the Guardhouse is
paged from the Main Entrance.
Press the Program button (P).
Press the Program Number (7).
Selection a Page Signal
0: Melody Tone
1: BELL Tone(RINGER)
ex) Selection a Page Signal selected melody tone
Enter the Building (Management) PIN.
ex) Building PIN
Call button (E).
Press the
Press the
Call button (E).
Page signal updated
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Press number 7 (Page Signal Selection).
⑤ Press the Call button (E). (Previous selection is displayed)
⑥ Select a page signal.
✽ 0: Melody Tone
✽ 1: Bell (Ringer)
⑦ Press the Call button (E). (Page signal updated)
Press the
Call button (E).
The current capacity
is displayed.
- 25-
Page 27
12. Wiring Method Selection
✽
P - Building (Management) PIN - E - 6 - E - 4 - E: 4-wire Common Method (12-wire common)
✽ P - Building (Management) PIN - E - 6 - E - 8 - E: 8-wire Common Method
✽ Video images from the Main Entrance cannot be viewed in the Household when the
8-wire Common Method has been selected.
Press the Program button (P).
Press the Program Number (6).
Select a wiring method
4: 4-wire Common Method
(12-wire common)
8: 8-wire Common Method
ex) Wiring method selected 4- wire commom method
Enter the Building (Management) PIN.
ex) Building PIN
Call button (E).
Press the
Press the
Call button (E).
Wiring method updated
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Press number 6 (Wiring Method Selection).
⑤ Press the Call button (E). (Previous selection is displayed)
⑥ Select a wiring method.
✽ 4: 4-wire Common Method (12-wire common)
✽ 8: 8-wire Common Method
⑦ Press the Call button (E). (Wiring method updated)
Press the
Call button (E).
The current capacity
is displayed.
- 26-
Page 28
13. Video Out Impedance Adjustment
✽ P - Building (Management) PIN - E - 8 - E - 0 - E: Short Distance
✽ P - Building (Management) PIN - E - 8 - E - 1 - E: Long Distance
✽ By default, the unit is set for short distance.
Do not change if possible.
Press the Program button (P).
Press the Program Number (8).
Select the Impedance
0: Short Distance
1: Long Distance
ex) Impedance Adjusted
Enter the Building (Management) PIN.
short distance
ex) Building PIN
Press the
Call button (E).
Press the
Call button (E).
Impedance selection updated
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Call button (E).
④ Press number 8 (Impedance Setup).
⑤ Press the Call button. (The previous selection is displayed)
⑥ Select the impedance.
✽ 0 : Short Distance
✽ 1 : Long Distance
⑦ Press the Call button (E). (Impedance selection updated)
Press the
Call button (E).
The current capacity
is displayed.
- 27-
Page 29
14. Household Interphone Diagnosis
✽ P - Building (Management) PIN - E - 14 - E - Household Number - E
✽ This feature checks for the Household Interphone’s operating conditions.
Press the Program button (P).
Press the Program Number (14).
Enter the Household Number, then press the Program button.
ex) check for 101
Enter the Multi Sub Number, then press the Page button (E).
ex) check for master status
Enter the Building (Management) PIN.
ex) Building PIN
Press the
Call button (E).
The Household’s status is shown on the display window (FND).
Press the
Call button (E).
Check feature the
Household Videophone
Normal status
Busy status
Away status
Press the
Call button (E).
✽After checking the currently displayed household, it will show automatically a next household.
Push the call button to check a next household.
You can check the whole households in the same way.
After checkup, push the cancel button.
Emergency status
- 28-
Page 30
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Page button (E).
④ Enter number 14 (Household Interphone Diagnosis).
⑤ Press the Page button (E). (‘Subt’will appear)
⑥ Enter the Household Number, then press the Program button.
⑦ Enter the Multi Sub Number, then press the Page button (E).
The Household’s status is shown on the display window (FND).
(Please refer to the following indications)
⑧ To check other Households, repeat steps 6 and 7.
Press the Cancel button (X) to terminate the feature.
✽ Household Status
Normal Status - The Household is in standby.
(Normal will also be indicated if the Household is in conversation
with the Entrance or on the phone)
Busy Status - The Household is on the phone.
(Busy status is only shown when in conversation with the
Guardhouse)
Away Status - Residents are currently away from their Household.
Emergency Status - There is an emergency situation in the
Household.
(Emergency, Warning 1 (Fire), Warning 2 (Gas), Burglary, and etc
are indicated as emergency situations)
Error Status - Connection could not be established with the
Household. (Please check the Household Videophone)
- 29-
Page 31
15. Household Number Registration
✽ P - Building (Management) PIN - E - 15 - E - Guardhouse page from the Household -
Household Number - P - Serial Numbe - E
✽ This feature is used to register Household Numbers through the Main Entrance
Interphone when the Guardhouse Interphone has not been installed. If the
Guardhouse Interphone is available, please use it to register.
Press the Program button (P).
Press the Program Number (15).
Lift up the receiver from the Household and press the Guard button to page the Main Entrance
Interphone, where the Household Number will be displayed.
(Then, the displayed number must be changed for it is the default number from the factory.)
Enter the Household number and press the Program button.
ex) Entering as Unit 101
Enter the Multi Sub number and press the Page button (E).
ex) Entering as Master
Enter the Building (Management) PIN.
ex) Building PIN
Call button (E).
ex) Entering as first
1234
Press the
Press the
Call button (E).
Household PIN
Entry Mode
Press the
Call button (E).
Follow the same procedure to enter other Households.
Press the Cancel button (X) to end.
- 30-
Page 32
<Note>
✽ What is Multi Sub Number?
Refers to individual numbers for each videophone in the Household when there is
more than one.
✽ The Master’s Serial Number is 0.
✽ Sub Serial Numbers are from 1 to 9.
✽ Maximum 10 videophones can be installed in a household, and their serial
numbers must not overlap.
✽ A Master must exist among numerous videophones. If only one videophone
exists, that unit shall be registered as the Master.
✽ When ADT-481 is installed in the Household, that unit will not be registered as the
Master.
① Press the Program button (P). (‘Prog’will appear)
② Enter the Building (Management) PIN.
③ Press the Page button (E).
④ Enter number 15 (Household Number Registration).
⑤ Press the Page button (E). (‘SUbA’will appear)
⑥ Lift up the receiver from the Household and press the Guard button to page the Main
Entrance Interphone, where the Household Number will be displayed. Then, the
displayed number must be changed for it is the default number from the factory.
⑦ Enter the Household number and press the Program button.
⑧ Enter the Multi Sub number and press the Page button (E).
⑨ The Main Entrance Interphone’s Display Window will convert to the (5) status.
⑩ To enter different Households, repeat steps 6 and 7.
⑪ Press the Cancel button (X) to end.
- 31-
Page 33
16. Paging the Household
Enter theHousehold Number.
ex) unit 101
Call button (E).
Wait for a reply
17. Paging the Guardhouse
Press the Guard button.Press the Page button.
A paging tone will sound.
Press the page button.
A paging tone will sound.
Press the
Wait for a reply
Press the
Call button (E).
- 32-
Page 34
18. Door Release Using the Household PIN
✽ Household Number - K - Household PIN - E
Enter the Household Number.
ex) To open the door of unit 101
Enter the Household PIN.Press the Page button.
Press the Call button (E).
19.
Door Release Using the Building (Management) PIN
Press the Electronic key button.
✽ G - K - Building (Management) PIN - E
Press the Guard button.
Press the Electronic key button.
Enter the Building or the
Management PIN.
Press the Page button.
Press the Call button (E).
- 33-
Page 35
20. Appendix (V arious Program Summaries)
✽ Various PIN Programs
1. P - Old Management PIN - E - 0 - E - New PIN- E: Management PIN Change
2. P- Old Building PIN - E -1 - E - New PIN - E: Building PIN Change
3. K - 20 - E - Household Number - E - Old Household PIN - E - New PIN - P: Household PIN
Change
4. P - Building (Management) PIN - E - 16 - E - Household Number - E: Household PIN
Confirmation
✽ Configuring Building and Serial Numbers from the Main Entrance Interphone
1. P - Building (Management) PIN - E - 2 - E - Building Number - E: Building Number Setup
2. P - Building (Management) PIN - E - 3 - E - Serial Number - E: Serial Number Setup
✽ Remote Cardkey Programs
1. P - Building (Management) PIN - E - 9 - E: Remote Cardkey Test
2. P - Building (Management) PIN - E - 10 - E: Remote Cardkey Registration
3. P - Building (Management) PIN - E - 11 - E: All Remote Cardkey Delete (Household PIN
Delete)
4. P - Building (Management) PIN - E - 12 - E: Individual Cardkey Delete
5. P - Building (Management) PIN - E - 13 - E: Remote Cardkey Confirmation
6. P - Building (Management) PIN - E - 19 - E: Expanding Remote Cardkey Capacity
✽ Door Release Using Various PINs
1.GP - KP - Building (Management) PINP - E: Door release using Building (Management) PIN
2.Household NumberP - KP - Household PINP - E: Door release using Household PIN
✽ Other Feature Setup Methods
1.P - Building (Management) PIN - E - 4 - E: Surveillance Monitor Setup
2.P - Building (Management) PIN - E - 5 - E: Door Release Time Setup
3.P - Building (Management) PIN - E - 6 - E: Wiring Method Selection
4.P - Building (Management) PIN - E - 7 - E: Paging Tone Selection
5.P - Building (Management) PIN - E - 8 - E: Video Out Impedance Selection
6.P - Building (Management) PIN - E - 14 - E: Household Interphone Diagnosis
7.P - Building (Management) PIN - E - 15 - E: Household Number Registration
8. P - Building (Management) PIN - E - 17 -
- 34-
- 34-
Page 36
21. Wiring Method
1) Guardhouse Interphone (CDS-481L)
Bk: Black
Br: Brown
R: Red
Or: Orange
Y: Yellow
G: Green
B: Blue
Pu: Purple
G: Gray
Rear Code Terminal
Talk 1~8, Data
Terminal for connection
with external Phone lines.
Rear Code Terminal
Bk Br ROrYGBPu G
Connection to a
Computer
For Computer
Connection
(Optional)
Bk Br ROrYGBPu G
Talk 1
Talk 2
1-2 :Call 1 (TIV 0.65mm×2C Non Polar)
3-4 :Call 2 (TIV 0.65mm×2C Non Polar)
5-6 :Call 3 (TIV 0.65mm×2C Non Polar)
7-8 :Call 4 (TIV 0.65mm×2C Non Polar)
9-10 :Call 5 (TIV 0.65mm×2C Non Polar)
11-12 : Call 6(TIV 0.65mm×2C Non Polar)
13-14 : Call 7(TIV 0.65mm×2C Non Polar)
15-16 : Call 8(TIV 0.65mm×2C Non Polar)
1-2 : Call 1(TIV 0.65mm×2C Non Polar)
3-4 : Call 2(TIV 0.65mm×2C Non Polar)
5-6 : Call 3(TIV 0.65mm×2C Non Polar)
7-8 : Call 4(TIV 0.65mm×2C Non Polar)
9-10 : Call 5(TIV 0.65mm×2C Non Polar)
11-12 : Call 6(TIV 0.65mm×2C Non Polar)
13-14 : Call 7(TIV 0.65mm×2C Non Polar)
15-16 : Call 8(TIV 0.65mm×2C Non Polar)
Talk 3
For Internal
Phone Line
DATA
GND
Talk 9~16, Data
- 35-
Page 37
2) Main Entrance Interphone (DRC-481L)
Bk
Br
R
Or
Y
G
Bk
Br
R
Or
Y
G
Infrared Sensor
Guardhouse
(Household
Videophone)
(Household
Videophone)
R
B
Y
Bk
Br
R
Or
Y
G
B
Pu
Bk
Br
R
Or
Y
Bk
Br
R
Or
Y
Bk: Black
Br: Brown
R: Red
Or: Orange
Y: Yellow
G: Green
B: Blue
Pu: Purple
G: Gray
W: White
R
Security
Door Release
Mechanism
B
Y
W
R
B
R
Y
Monitor
Security
① DC 12V used.
② Designed to be used by connecting to the lead switch. When not in use, please connect two wires.
③ When the Main Entrance is opened by force, the Guardhouse and the computer are notified.
- 36-
Page 38
(DRC-500L)
Guardhouse
(Household
Videophone)
(Household
Videophone)
Monitor
Infrared Sensor
Bk
Br
R
Or
Y
G
Bk
Br
R
Or
Y
G
Bk
Br
R
Or
Y
G
B
Pu
Bk
Br
R
Or
Y
Bk
Br
R
Or
Y
R
B
Y
W
R
B
Y
R
B
R
Y
Bk: Black
Br: Brown
R: Red
Or: Orange
Y: Yellow
G: Green
B: Blue
Pu: Purple
G: Gray
W: White
Door Release
Terminal
Security
① Use DC 15V.
② It is designed to use a reed switch. When it is not used, connect two lines.
③ When the main entrance door is forced to open, it will be notified to the guardhouse and a
computer.
- 37-
Page 39
3) Household Videophone(CH-481SL)
4) Household Videophone(APV-481FT)
R
Telephone
B
R
B
Y
W
Bk
Talk
Br
R
Or
Y
Bk
Talk 1
Br
R
Talk 2
Or
Y
Talk 3
G
B
Pu
R
Emergency
B
Bk
Br
R
Or
Main Entrance Call
Y
G
B
R
Telephone
B
R
B
Y
W
Bk
Talk
Br
R
Or
Y
Bk
Talk 1
Br
R
Talk 2
Or
Y
Talk 3
G
B
Pu
Bk
Br
R
Or
Sensor
Y
G
B
Pu
G
Bk
Br
R
Or
Main Entrance Call
Y
G
B
Household Camera
Guardhouse
Household Camera
Main Entrance
Guardhouse
Warring1
Warring2
Burglar
Emergency
Main Entrance
Extention
Bk: Black
Br: Brown
R: Red
Or: Orange
Y: Yellow
G: Green
B: Blue
Pu: Purple
G: Gray
W: White
Sensor
Extention
- 38-
Page 40
5) Household Videophone(CAV-50FSD)
6) Household Videophone(CAV-50FD)
R
Telephone
B
R
B
Y
W
Bk
Talk
Br
R
Or
Y
Bk
Talk 1
Br
R
Talk 2
Or
Y
Talk 3
G
B
Pu
Bk
Br
R
Or
Sensor
Y
G
B
Pu
G
Bk
Br
R
Or
Main Entrance Call
Y
G
B
Household Camera
Main Entrance
Guardhouse
Warring1
Warring2
Burglar
Emergency
Extention
Bk: Black
Br: Brown
R: Red
Or: Orange
Y: Yellow
G: Green
B: Blue
Pu: Purple
G: Gray
W: White
Sensor
- 39-
R
Telephone
B
R
B
Y
W
Bk
Talk
Br
R
Or
Y
Bk
Talk 1
Br
R
Talk 2
Or
Y
Talk 3
G
B
Pu
Bk
Br
R
Or
Main Entrance Call
Y
G
B
Household Camera
Main Entrance
Guardhouse
Extention
Page 41
7) Household Videophone(CAV-501D)
R
B
Telephone
Bk: Black
Br: Brown
R: Red
Or: Orange
Y: Yellow
G: Green
B: Blue
Pu: Purple
G: Gray
W: White
R
B
Y
W
Bk
Talk
Br
R
Or
Y
Bk
Talk 1
Br
R
Talk 2
Or
Y
Talk 3
G
B
Pu
Bk
Br
R
Sensor
Or
Y
G
B
Pu
G
Bk
Br
R
Or
Main Entrance Call
Y
G
B
Household Camera
Main Entrance
Guardhouse
Warring1
Warring2
Burglar
Emergency
Extention
- 40-
Page 42
8) Household Videophone(CAV-482S)
Bk: Black
Br: Brown
R: Red
Or: Orange
Y: Yellow
G: Green
B: Blue
Pu: Purple
G: Gray
W: White
R
Telephone
B
R
B
Y
W
Bk
Talk
Br
R
Or
Y
Bk
Talk 1
Br
R
Talk 2
Or
Y
Talk 3
G
B
Pu
Bk
Br
R
Sensor
Or
Y
G
B
Pu
G
Bk
Br
R
Sensor
Or
Y
Bk
Br
R
R
Y
Bk
Br
R
Or
Main Entrance Call
Y
G
B
Household Camera
Main Entrance
Guardhouse
Warring1
Warring2
Sensor
Burglar
Emergency
Burglar 1
Sensor
Burglar 2
Communication
Power
Extention
- 41-
Page 43
9) TV-Phone Interface Adaptor(ADT-481)
R
B
Bk
Br
R
Or
Y
G
B
Pu
Bk
Br
R
Or
Y
G
B
Bk
Br
R
Or
Y
G
B
Pu
Extention
Unit DC
Guardhouse
Main Entrance Call
Guardhouse(CKV-60T)
Door Release(CKV-60T)
Camera
Talk 1
Talk 2
Talk 3
10) Security Interface Adaptor(ADT -482)
(Supply of CAV-482S)
Power
Burglar 1
Sensor
Burglar 2
Sensor
R
B
R
B
Bk
Br
R
Or
Y
Bk: Black
Br: Brown
R: Red
Or: Orange
Y: Yellow
G: Green
B: Blue
Pu: Purple
G: Gray
W: White
Sensor
Burglar 1
Burglar 2
Communication
Sensor
Telephone
Bk
Br
R
Or
Y
Bk
Br
R
R
B
- 42-
Page 44
11) System Map
Household
VideophoneCzmera
Czmera
Common 4
Lobby 2Lobby 1
Lobby
Phone
Lobby
Phone
Monitor
Lobby
Phone
※ Note
Ⓐ : Guardhouse Line (Common 8-wire)
Ⓑ : Main Entrance Line (Common 4-wire)
Ⓒ : External Call Line (Common 18-wire)
Ⓓ : Enternal Extension Line (Common 16-wire) → Optional
Lobby 2Lobby 1
GuardhouseGuardhouse
Household
Videophone
Common 4
- 43-
Lobby
Phone
Monitor
Page 45
12) Wiring Method for Communications with the Guardhouse
Bk: Black
Br: Brown
R: Red
Or: Orange
Y: Yellow
G: Green
B: Blue
Pu: Purple
G: Gray
W: White
Bk
Br
R
Or
Y
G
B
Pu
Bk
Br
R
Or
Y
G
B
Pu
Bk
Br
R
Or
Y
G
B
Pu
Bk
Br
R
Or
Y
G
B
Pu
Bk
Br
R
Or
Y
G
B
Pu
Bk Br ROrYGBPu
- 44-
Page 46
13) Main Entrance Interphone Wiring
※ NOTE
1. Main Entrance System
•Bk
•Br
•R
•Or
•Y
CALL
GND
VD/IN
VD/OUT
2. Household Videophone
•Bk
•Br
•R
•Or
•Y
CALL
GND
VD/IN
VD/OUT
Bk
Br
R
Or
Y
Bk
Br
R
Or
Y
Bk
Br
R
Or
Y
Bk
Br
R
Or
Y
Bk
Br
R
Or
Y
Bk
Br
R
Or
Y
Camera 1
Bk
Br
R
Or
Y
Camera 2
Bk
Br
R
Or
Y
Bk: Black
Br: Brown
R: Red
Or: Orange
Y: Yellow
G: Green
B: Blue
Pu: Purple
G: Gray
W: White
3. If the Guardhouse Interphone (CDS-481L) has been installed, Number 7 (Data) and 8 (GND)
connected to it must be connected to the Household Interphone.
4. Use coaxial cables (3C2V or 5C2V) for Video Out.
- 45-
Page 47
14) Wiring ADT-481 and CKV-60T
Bk: Black
Br: Brown
R: Red
Or: Orange
Y: Yellow
G: Green
B: Blue
Pu: Purple
G: Gray
W: White
15) Wiring ADT-482 and C AV-482S
Telephone
Household Camera
Main Entrance
Guardhouse
Sensor
Sensor
Extention
Communication
R
B
Bk
Br
R
Or
Y
Bk
Br
R
R
B
Guardhouse
Guardhouse
OPEN/CLOSE
OPEN/CLOSE
Telephone
Burglar 1
Burglar 2
IN
GND
B+
VD
Bk
Br
R
Or
Y
G
B
Pu
Sensor
R
B
R
B
Bk
Br
R
Or
Y
Bk
Br
R
Or
Y
R
B
Y
R
B
- 46-
Page 48
16) Installing Numerous Videophones in a Household
Household
Camera
Multysub Number
Bk
Br
R
Or
G
Multysub NumberMultysub NumberMultysub Number
Loby Talk
Y
B
Multysub NumberMultysub NumberMultysub NumberMultysub Number
Household
Camera
Bk
Br
R
Or
Loby TalkLoby TalkLoby Talk
Y
G
B
※NOTE
1. Ⓐ : Guardhouse Line (8-wire Common)
Ⓑ : Main Entrance Line (4-wire Common)
Ⓒ : Sub Extension (6-wire Common)
Bk
Br
R
Or
Loby TalkLoby Talk
Y
G
B
Bk
Br
R
Or
Y
G
B
Bk
Br
R
Or
Y
G
B
Bk
Br
R
Or
Y
G
B
2. When registering the Multi Sub number, ADT-481 will not be recognized as the Master and should be
installed last as shown above.
3. Various types of sensors should be connected to the Master, and sensors of the remaining Subs should be
connected with the + wire and the sensor line: if the two lines are not connected, the Away mode will not
function.
- 47-
Page 49
17) CCTV and Sensor Wiring
Monitor 1
R
B
Y
R
B
Y
W
R: Red
Y: Yellow
B: Blue
W: White
CAMERA 1
CAMERA 2
Monitor 2
R
B
Y
W
※ NOTE
1. Monitor 1: To view only when being used by the Main Entrance Interphone (DRC-481L).
2. Monitor 2: Continuous surveillance of the Main Entrance.
- 48-
Page 50
18) Wiring DRC-481L and CDS-481PC
Y
R
G
Br
Or
Bk
Y
R
G
Br
Or
Bk
Y
R
G
Br
Or
Bk
①Or(Line)
②Or
③G(Line)④B⑤B(Line)⑥G⑦Br(Line)
- 49-
Y
R
G
Br
Or
Bk
⑧Br
Page 51
19) Wiring CDS-481PC and Multi Port
- 50-
Page 52
22. Specifications
Installation Method
Specfications
Transmission System
Rated Voltage
Power Consumption
Communication Method
Imaging Device
Scanning Frequency
Camera Angle
Minimum Illumination
Communication Distance
Detection Range
Lighting
Ambient Temperature
Dimensions