33. Part list ...................................................................................................................................52
34. Specifications and Features ..................................................................................................52
35. RF-ID Model (Optional) .........................................................................................................53
1. Greeting
* Thank you for purchasing a COMMAX product
* This product is a high tech Main Entrance interphone that supports electronic
Please read this manual carefully.
1
Page 3
2. Safety Warning & Caution
www.safemag.ru
www.safemag.ru
Please follow the things described below in order to prevent any
danger or property damage.
Prohibition.
Warning
Caution
It may cause a serious damage or
injury if violated.
It may cause a minor damage or
injury if violated.
No disassembly
No touch
Must follow strictly.
Shows plugging out the power cord
without an exception
Shows the warning and caution for an electric shock.
Shows the warning and caution for a fire.
Warning
Please don’t use several
products at the same time on
one power socket.
·It may cause a fire due to an
ab
normal overheating.
Please don’t install the
product in the place where
there is much oil, smoke or
humidity.
·It may cause an electric
shock or fire.
Power & Installation
Please don’t bend the power
cable excessively or it may
cause an electric shock.
·fire when using a damaged
power cable.
Please don’t install the
product with the lightening
and thunder.
·It may cause an electric
shock or fire.
Please don’t handle the power
cable with a wet hand.
·It may cause an electric
shock.
Please don’t use and connect
this product with other
products with different rated
voltage
·It may cause a disorder or
fire.
Please plug out the power
cable from the socket when
not using it for a long period
of time.
·It may shorten the product
lifespan or cause a fire.
When installing the product
that generates heat, please
install the product away from
the wall (10cm) for the
ventilation.
·It may cause a fire due to
the increased internal
temperature.
2
Page 4
Warning
www.safemag.ru
www.safemag.ru
Please don’t disassemble,
repair or rebuild this product
arbitrarily (please contact the
service center if a repair is
needed.
·It may cause an electric
shock or fire.
Cleaning & UsePower & Installation
Please plug the power cable
firmly into the inner end
·It may cause a fire.
Please be careful when using
an AC circuit breaker since
there is a possibility of an
electric shock.
If an abnormal sound, burning
smell or smoke is coming out
of the product, please plug out
the power cable and contact a
service center.
·It may cause an electric
shock or fire.
Caution
Please hold the plug tightly
when unplugging the power
cable (a part of the copper
wire may be disconnected if
the grabbing is only made on
the cord when pulling out the
cable).
·It may cause an electric
shock or fire
Please check the use voltage
and current for the DC-only
products and use the
appropriate rectifier.
·It may cause a fire.
Please don’t insert any
metallic or burnable materials
into the ventilation hole.
·It may cause an electric
shock or fire.
When connecting the power
cables after cutting the cable,
please install the product with
power off
·It may cause an electric
shock or fire
Please avoid direct rays of the
sun or heating devices at a
time of installation.
·It may cause a fire.
Please use only the designated
batteries for the products of
using DC power.
·It may cause an electric
shock or fire.
When installing the product,
please fix it firmly while using
the wall-mounting unit and
screws.
·It may cause an injury from
the falling object.
Please don’t install the
product on an unstable place
or small support board.
·It may cause an injury if it
falls down while in use.
Cleaning & Use
When cleaning the product,
please rub it with a soft and
dry cloth after plugging out
the power cable. (Please don’t
use any chemical products
such as wax, benzene, alcohol
or cleanser.)
Please don’t drop the product
on the ground and don’t apply
a shock .
·It may cause a failure.
Please use the designated
connection cable within the
maximum calling distance
designated for the product
·It may reduce the product
performance.
3
Page 5
3. Parts
www.safemag.ru
www.safemag.ru
3-1. The name of parts
NO.Function NO.Function
1Speaker
2OLED Display
3RFID card receiver
Name Searching button /
4
Menu Page Button
Up & Down scroll button/
5
Program Button
6Call Button
7Number button
8Cancel Button
9C-MIC
10 Electric Key Button
11 Line connecting button
12 Reset Button
13 Circuit Connect Switch
4
Page 6
3-2. Important function
www.safemag.ru
www.safemag.ru
✽ Starting OLED display (Power ON OLED display)
✽ RF/ID Receiver ③(Optional)
When open door by wireless card key, please tag it to this points.(See bellow
photo).
"Open door" message and Icon will be displayed in OLED.
✽ Call Button ⑧(E : Press)
Call unit (House).
✽ Program button ⑦(P : Program)
Call program menu button.
(Press and hold over 5 sec, then menu will be activated)
5
Page 7
✽ Name searching button ⑥(S : Search)
www.safemag.ru
www.safemag.ru
Tenants name searching button.
✽ Electric key button ⑫(K : Key)
Open door by Password Number.
(Deactivate Password LOCK function only.)
✽ Cancel button ⑩(X : Cancel)
When user wants to cancel function, press it.
✽ Reset button ⑮
Reset security guard password or management office password.
When forgot password, press reset button which is on back side of products 15
(Press & Hold over 3 sec. after power on)
6
Page 8
✽ Call security
www.safemag.ru
www.safemag.ru
1. Press, name search button and call security which is top of the name list.
2. Press "9999" and press call button.
✽ Must know before use.
1) If you hear "beep beep beep..."during any program modes, please restart from
the beginning. The beep sounds for improper process.
2)
If password is forgotten,
2-1) Password for any household :
Use the identifying household password function (6-1) to confirm the password
(methods to confirm password shall be requested to the Management office or
Security cPress).
2-2) Password for any building:
Reset the password by using Management password
2-3) Password for Management
Press "Reset Button"..
The password will be reset to factory default.
3) Deleting All RF Card Keys function in "8-5" shall ONLY be used when the
product is initially installed.
7
Page 9
4. Password type
www.safemag.ru
www.safemag.ru
4-1. Password for the Management Office ("Management Password")
A password for the Manager
Factory default for the Manager Password is 4321.
4-2. Password for any buildings ("Building Password")
A common password for a corresponding building.
Factory default for the Building Password is 1234.
4-3. Password for any household units "Unit Password")
A password for each household unit can be set.
Factory default for the Unit Password is 1234.
8
Page 10
5. How to input Password
www.safemag.ru
www.safemag.ru
5-1. Press management Password
• P - old Password - E - New Password - E
• Password must be 4 digits.
• "0000", "1234", "4321" can't be used as Password
① Press program button (P).
② Press old management default Password (4,3,2,1).
③ Press call button (E).
④ Press "0" (Set up management Password button)
⑤ Press call button (E).
⑥ Press new Password.
⑦ Press call button (E).
⑧ Management Password has been changed.
<Caution>
Please do not keep the factory default password. New password setting
after the installation is strongly recommended.
9
Page 11
5-2. Press building Password
www.safemag.ru
www.safemag.ru
• P - old Password - E - 1 - E - New Password - E
• Password must be 4 digits.
•"0000°", "1234", "4321" can't be used as Password
① Press program button (P).
② Press old building default Password (4,3,2,1).
③ Press call button (E).
④ Press "1" (Set up building Password button)
⑤ Press call button (E).
⑥ Press new Password.
⑦ Press call button (E).
⑧ Building Password has been changed.
10
Page 12
5-3. Press house (Unit) Password
www.safemag.ru
www.safemag.ru
• K - 20 - E- house Number - E- old Password - E - New Password - E
• Password must be 4 digits.
•"0000", "1234", "4321" can't be used as Password
• Unit Password no. may not be changed because of Interphone types.
(Some model of Interphone can change Password in house. Please, check manual of
interphone)
① Press program button (K)
② Press "20" (Set unit Password Number)
③ Press call button (E).
④ Press house Number
⑤ Press call button (E).
⑥ Press old house Password (4,3,2,1).
⑦ Press call button (E).
⑧ Press new house Password.
⑨ Press call button (E).
⑩ House Password has been changed.
11
Page 13
6. Check house Password
www.safemag.ru
www.safemag.ru
6-1. Check house Password
• P - management Password - E - 16 - E - Household Unit Number E
① Press program button (P).
② Press management Password.
③ Press call button (E).
④ Press "16" (Set ID Number function key)
⑤ Press call button (E).
⑥ Press new ID Number
⑦ Press call button (E).
⑧ ID Number has been changed.
12
Page 14
7. Set building Number and ID to Lobby panel
www.safemag.ru
www.safemag.ru
• This setting is mandatory because building Number and ID automatically are set up when
lobby panel call house and security guard.
• Max. 99 lobby panel can be installed for one building.
7-1. Set building Number in Lobby panel interphone.
• P - Management Password - E - 2 - E - Building Number - E
① Press program button (P).
② Press management Password.
③ Press call button (E).
④ Press "2" (Set building Number function key)
⑤ Press call button (E).
⑥ Press new building Number
⑦ Press call button (E).
⑧ Building Number has been changed.
13
Page 15
7-2. Set ID no. in Lobby Panel
www.safemag.ru
www.safemag.ru
• P - Management Password - E - 3 - E - ID - E
① Press program button (P).
② Press management Password.
③ Press call button (E).
④ Press "3" (Set ID Number function key)
⑤ Press call button (E).
⑥ Press new ID Number
⑦ Press call button (E).
⑧ ID Number has been changed.
14
Page 16
8. RF card key appliances
www.safemag.ru
www.safemag.ru
8-1 RF card key test way
• P- Management Password - E - 9 - E - Card Test - X(Cancel)
• This function is only for the test of wireless card key
① Press down the (P) button
② Press Management Passwords
③ Press Call Button "E".
④ Press number "9" for the test of wireless card key
⑤ Press Call Button "E"
⑥ The card registration number will be on OLED when the card key is close to the RF/ID
⑦ Press down the (X) button for finish after test.
receiver.
15
Page 17
8-2. RF card key input way
www.safemag.ru
www.safemag.ru
• P- Management Password - E- 10 - E - Place card close to the RF/ID receiver - X(cancel)
<References>
Up to 2048 cards can be registered(if not to connect with SecuMAX)
16
Page 18
8-3. RF card key separate deletion way
www.safemag.ru
www.safemag.ru
• P - Management Password - E - 12 - E - Delete cards - X(Cancel)
① Press Program Button "P"
② Press Management Password
③ Press Call Button "E"
④ Press number "12"(separate delete number)
⑤ Press Call Button "E"
⑥ Place the card key close to the RF/ID receiver.
⑦ Press down the "X" to finish when separate deletion is completed
17
Page 19
8-4. RF card key registration check way
www.safemag.ru
www.safemag.ru
• P- Management password - E - 13 - E - Check the cards - X(Cancel)
① Press Program Button "P"
② Press Management Password
③ Press Call Button "E"
④ Press number "13"(registration check)
⑤ Press Call Button "E"
⑥ Place the card key close to the RF/ID receiver
⑦ Press down X button to finish when check is completed
18
Page 20
8-5. RF card key all delete way
www.safemag.ru
www.safemag.ru
• P - Management password - E - 11 - E - E
• All deletion way is only useful when initially set up, unless all registered cards are to be
deleted.
① Press down "P" button
② Press Management Password
③ Press down "E" button
④ Press number "11" (all delete number)
⑤ Press Call Button "E"
⑥ Press Call Button "E" one more
⑦ The number on OLED display to be changed
⑧ Press down X button if to cancel.
<References>
All numbers can be deleted only if the mode "1" in the program
number(23) is selected & executed the all delete process within 30
seconds.
19
Page 21
8-6. RF card key capacity change way
www.safemag.ru
www.safemag.ru
• P- Management password - E - 19 - E - 0 - E : Up to 2048 RF Cards can be registered
• P- Management password - E - 19 - E - 1 - E : Unlimited RF Cards can be registered
① Press down "P" button
② Press Management Password
③ Press down "E" button
④ Press number "19" (capacity change number)
⑤ Press Call Button "E"
⑥ Select mode between numbers "0" and "1".
⑦ Press Call Button "E"
(0 : Up to 2048 RF Card Keys can be registered)
(1 : Unlimited RF Card Keys can be registered)
20
Page 22
8-7. RF card key data transmission
www.safemag.ru
www.safemag.ru
• P - Management Passwords - E - 32 - E - Press destination lobby phone number - E
① Press Program Button "P"
② Press Management password
③ Press Call Button "E"
④ Press number "32" for data transmission
⑤ Press Call Button "E"
⑥ Press number "destination lobby phone number"
⑦ Press Call Button "E"
<References>
• Data can be sent only if the mode "99" in the program number(23) is
selected & executed the process within 30 seconds.
• You cannot use any other function before it completes(It takes about 5
minutes). If you want to complete more quickly, use the download
program.
21
Page 23
8-8. RF card key data reception
www.safemag.ru
www.safemag.ru
• P- Management Passwords - E - 33 - E - Press source lobby phone number - E
① Press Program Button "P"
② Press Management password
③ Press Call Button "E"
④ Press number "33" for data reception
⑤ Press Call Button "E"
⑥ Press number "source lobby phone number"
⑦ Press Call Button "E"
<References>
• Data can be received only if the mode "99" in the program
number(23) is selected & executed the process within 30 seconds.
• You cannot use any other function before it completes(It takes about 5
minutes). If you want to complete more quickly, use the download
program.
22
Page 24
9. Set to be forced opening the Main Entrance
www.safemag.ru
www.safemag.ru
door by SecuMAX
• P - Management password - E - 22 - E - 0 - E : Forwarding to SecuMAX disabled
• P - Management password - E - 22 - E - 1 - E : Forwarding to SecuMAX enabled
• This function is to set the door release by internal sensor information forwarding to
SecuMAX.
① Press Program Button "P"
② Press Management Passwords
③ Press Call Button "E" for call
④ Press number "22" for forwarding to SecuMAX
⑤ Press Call Button "E"
⑥ Select the mode
⑦ Press Call Button "E"
(0 : Forwarding to SecuMAX disabled)
(1 : Forwarding to SecuMAX enabled)
23
Page 25
10. Door opening hours setting
www.safemag.ru
www.safemag.ru
• P - Management Passwords - E - 5 - E - Opening hours - E
• This function is to control the common entrance door opening hours
① Press Program Button "P"
② Press Management Passwords
③ Press Call Button "E"
④ Press number "5" for door opening hours setting
⑤ Press Call Button "E"
⑥ Select door opening hours(Opening hours is in the middle of 1~25 seconds)
⑦ Press down any number for setting of door opening hours between 0~25 seconds
⑧ Press Call Button "E"(Changed opening hours is input)
24
Page 26
11. Line-by-line call function Setting
www.safemag.ru
www.safemag.ru
• P - Management password - E - 21 - E - 0 - E: available for entire house call
• P - Management password - E - 21 - E - Line number - E : call only specified line
ex) In case 1 line ~ 2 line, input "0102"
• This function is only for specified line call, not for entire house call
① Press Program Button "P"
② Press Management Passwords
③ Press Call Button "E"
④ Press number "21" for call line-by-line
⑤ Press Call Button "E"
⑥ Select the line for call
ex) If to call only from 1 line to 3 line, Press "0103"
⑦ Press Call Button "E"(Changed setting would be input)
25
Page 27
12. Automatic calling function of guard station
www.safemag.ru
www.safemag.ru
configuration
• P - Management password - E - 27 - E - 0 - E : Automatic call mode
• P - Management password - E - 27 - E - 1 - E : Emergency call mode
• This function is to set the automatic calling to the security station when the failure of
Password occurs more than 3 times.
① Press Program Button "P"
② Press Management Passwords
③ Press Call Button "E" for call
④ Press number "27"
⑤ Press Call Button "E"
⑥ Select the mode
• P - Management password - E - 7 - E - 0 - E : Melody sound
• P - Management password - E - 7 - E - 1 - E : Bell(Ringer sound)
• This function is to set the recall sound of house & guard station at the common entrance
① Press Program Button "P"
② Press Management Passwords
③ Press Call Button "E" for call
④ Press number "7" for selection of call tones
⑤ Press Call Button "E" for cal
⑥ Select the mode
(0 : Melody sound)
(1 : Bell sound)
⑦ Press Call Button "E"(Changed call tones will be set)
27
Page 29
14. Setting the Number of Call Ring Repetitions
www.safemag.ru
www.safemag.ru
• P - Management Password - E - 25 - E - 0 - E : Continuous call ring enabled.
• P - Management Password - E - 25 - E - 1 - E : 1 time Call ring enabled.
• This function sets number of call ring repetition when a call is made to any households
or security office.
① Press Program Button "P".
② Press Management Password.
③ Press Call Button "E".
④ Press "25" (number twenty-five)
⑤ Press Call Button "E".
⑥ Select the mode
(0 : Continuous call ring)
(1 : 1 time call ring)
⑦ Press Call Button “E”
28
Page 30
15. Door release by external information
www.safemag.ru
www.safemag.ru
forwarding to SecuMAX way
• P - Management password - E - 18 - E - 0 - E : Forwarding to SecuMAX disabled
• P - Management password - E - 18 - E - 1 - E : Forwarding to SecuMAX enabled
• This function is to set the door release by internal sensor information forwarding to
SecuMAX.
① Press Program Button "P"
② Press Management Passwords
③ Press Call Button "E" for call
④ Press number "18" for forwarding to SecuMAX
⑤ Press Call Button "E"
⑥ Select the mode
⑦ Press Call Button "E"
(0 : Forwarding to SecuMAX disabled)
(1 : Forwarding to SecuMAX enabled)
29
Page 31
16. Set to be forced opening the Main Entrance
www.safemag.ru
www.safemag.ru
door by SecuMAX
• P - Management password - E - 29 - E - 0 - E : Forced opening by SecuMAX disabled
• P - Management password - E - 29 - E - 1 - E : Forced opening by SecuMAX disabled
• This function is to set the opening the Main Entrance door forced opening by SecuMAX
① Press Program Button "P"
② Press Management Passwords
③ Press Call Button "E" for call
④ Press number "29"
⑤ Press Call Button "E"
⑥ Select the mode
⑦ Press Call Button "E"
(0 : Forced opening by SecuMAX disabled)
(1 : Forced opening by SecuMAX enabled)
30
Page 32
17. Setting the time to trigger the notice to be
www.safemag.ru
www.safemag.ru
forced door forwarding to SecuMAX
• P - Management password - E - 24 - E - 0 - E : This function is disabled
• P - Management password - E - 29 - E - 1 - E : Set the time(second)
• This function is to set the time to trigger the notice to be forced door forwarding to
SecuMAX
• If you use this function, you should set the time more 1 second than the door close time.
• The notice forwarding to SecuMAX after 2 seconds when to be forced opening
① Press Program Button "P"
② Press Management Passwords
③ Press Call Button "E" for call
④ Press number "24"
⑤ Press Call Button "E"
⑥ Select the mode
⑦ Press Call Button "E"
(0 : This function is disabled)
(1 : Set the time(1~25 seconds)
31
Page 33
18. Selecting the Wiring Method
www.safemag.ru
www.safemag.ru
• P - Management Password - E -6 - E - 4 - E : common 4 wire method
• P - Management Password - E - 6 - E - 6 - E : common 6 wire method
• If common 6 wire method selected, there will be no signal sent to all household units.
① Press Program Button "P".
② Press Management Password.
③ Press Call Button "E".
④ Press "6" (number six).
⑤ Press Call Button "E".
⑥ Select the wiring method by Pressing number
(4 : Common 4 Wire Method)
(6 : Common 6 Wire Method)
⑦ Press Call Button "E".
32
Page 34
19. Registration of Household Unit Number
www.safemag.ru
www.safemag.ru
• P - Management Password - E - 15 - E - Call Security from the monitor.- number of
household - E - serial number - E
• This method applies to the case that there is no security station installed. Calling
security from the monitor will direct the call to the lobby phone. Household Unit Number
can be set at the lobby phone.
33
Page 35
① Press Program Button "P".
www.safemag.ru
www.safemag.ru
② Press Management password.
③ Press Call Button "E".
④ Press "15" (number fifteen).
⑤ Press Call Button "E".
⑥ From a household unit, call security. The factory default household unit number appears
on the OLED display of the lobby phone. Please Press the actual unit number.
⑦ Press the actual unit number and press Call Button "E".
⑧ Press "0" (0 is Master lobby phone number. If multiple lobby phones are installed,
please Press the corresponding lobby phone number) and press Call Button "E".
⑨ On the OLED display, the unit number input mode appears.
⑩ By repeating 6, 7, 8, 9 procedures, other unit numbers can be registered.
⑪ As unit number registration is done press Cancel Button "X" to exit.
<References>
• This method applies to the case that it is possible to install Slave-
phones.
• Master-videophone's "Multi Sub Number" is number 0 (zero).
• Sub-videophone's "Multi Sub Number" is given between 1 and 9.
• Up to 10 videophones can be installed in a single household unit and
the "Multi Sub Numbers" shall not be overlapped.
• "Multi Sub Numbers" for sub-videophones shall be registered in
numerical order.
• At least one Master-videophone with "Multi Sub Number 0" must be
installed and if only one videophone is installed, it is considered as
Master-videophone (set as Multi Sub Number 0).
• In case that ADT-481 is installed, it does not register as Master unit.
• If sub-videophone is 485 system, its Master-videophone's Multi Sub
Number is 1 (one) and those of sub-videophones are between 2 and
9.
34
Page 36
20. Checking Status of Household Units
www.safemag.ru
www.safemag.ru
• P - Management password - E - 14 - Unit Number - E - serial number - E
• This function is to check the status of installed in each household unit.
35
Page 37
① Press Program Button "P".
www.safemag.ru
www.safemag.ru
② Press Management Password.
③ Press Call Button "E".
④ Press "14" (number fourteen).
⑤ Press Call Button "E".
⑥ Press the Unit Number and press Call Button "E".
⑦ Press "0" (number zero as Master lobby phone or Press a corresponding lobby phone
number) and press Call Button "E". Status of the household unit appears (Please refer to
below for the status).
⑧ To check another unit status, repeat 6 & 7 procedures.
⑨ As the status check is done press Cancel Button "X" to exit.
Status of household unit indication
• Standby : standby mode
(applies even when the household unit monitor is
communicating with an individual door phone of the unit or
via telephone line.)
• Busy Line : Busy mode
(applies when the household unit monitor is communicating
with another household unit or security station.
• If there is a function to set away mode in household unit, you can
check below.
• Away status : Away mode
• Emergency : in case of emergency
(emergency, fire, gas leak, burglar)
36
Page 38
21. Setting the Keypad LED Option
www.safemag.ru
www.safemag.ru
• P – Management Password – E – 20 – 0 – E : Keypad LED OFF
• P – Management Password – E – 20 – 1 – E : Keypad LED ON
• This function to set keypad LED ON/OFF.
① Press the program button (P).
② Please set up the Management password.
③ Press the call button (E).
④ Press number “20” (setting number of Electronic key)
⑤ Press the call button (E).
⑥ Select mode by numbers “0” or “1”.
(0 : White keypad LED light only work when you used lobby phone)
(1 : White keypad LED light always on)
⑦ Press the call button (E).(It will be changed)
37
Page 39
22. Activation of Electronic Key (Password) Function
www.safemag.ru
www.safemag.ru
• P - Management Password - E - 31 - 1 - E : Electronic Key (Password) enabled.
• P - Management Password - E - 31 - 0 - E : Electronic Key (Password) disabled.
• This function is to enable or disable the password access.
① Press Program Button "P".
② Press Management Password.
③ Press Call Button "E".
④ Press "31" (number thirty-one).
⑤ Press Call Button "E".
⑥ Select mode between numbers "0" and "1".
(1 : Password enabled)
(0 : Password disabled)
⑦ Press Call Button "E".
38
Page 40
23. Setting the Volume of Voice and Beep Sound
www.safemag.ru
www.safemag.ru
• P - Management Password - E - 30 - E - Beep Volume (1~2) - Voice Volume (1~7) - E
• This function enables the adjustment of Beep & Voice volume.
① Press Program Button "P".
② Press Management Password.
③ Press Call Button "E".
④ Press "30" (number thirty).
⑤ Press Call Button "E".
⑥ Press desirable Beep Volume (1~2) and then desirable Voice Volume (1~7).
⑦ Press Call Button "E".
<References>
• Beep sound volume applies to paging tone and button sound tone.
39
Page 41
24. Method of name data sending
www.safemag.ru
www.safemag.ru
• P - Management Password - E - 34 - E - Press destination lobby phone number - E
① Press Program Button "P".
② Press Management Password.
③ Press Call Button "E".
④ Press number "34" (setting number of caller name)
⑤ Press Call Button "E".
⑥ Press number "destination lobby phone number"
⑦ Press Call Button "E".
<References>
• Data can be send only if the mode "99" in the program number(23) is
selected & executed the process within 30 seconds.
• You cannot use any other function before it completes(It takes about 5
minutes). If you want to complete more quickly, use the download
program.
40
Page 42
25. How to receive the name of the data
www.safemag.ru
www.safemag.ru
• P - Management Password - E - 35 - E - Press source lobby phone number - E
① Press Program Button "P".
② Press Management Password.
③ Press Call Button "E".
④ Press number "35" (setting number of name data)
⑤ Press Call Button "E".
⑥ Press number "source lobby phone number".
⑦ Press Call Button "E".
<References>
• Data can be received only if the mode "99" in the program number(23)
is selected & executed the process within 30 seconds.
• You cannot use any other function before it completes(It takes about 5
minutes). If you want to complete more quickly, use the download
program.
41
Page 43
26. Setting the door release by building password
www.safemag.ru
www.safemag.ru
26-1. Setting the Door Release by Building Password
• P – Management Password – E – 28 – 1 – E : Door release by Building Password
enabled.
• P – Management Password – E – 28 – 0 – E : Door release by Building Password
disabled.
• This function enables the door release by Building Password.
• This function provides least security to the access of the entrance since the password is
being shared among number of people. Please keep the security of Building Password
strictly and/or change the Building Password periodically.
① Press Program Button “P”.
② Enter Management Password.
③ Press Call Button “E”.
④ Enter “28” (number twenty-eight).
⑤ Press Call Button “E”.
⑥ Select mode between the numbers “0” and “1”.
(1 : Door release by Building Password enabled)
(0 : Door release by Building Password disabled)
⑦ Press Call Button “E”.
42
Page 44
26-2. Using a door release by Building Password function.
www.safemag.ru
www.safemag.ru
43
Page 45
27. When you want to call a household
www.safemag.ru
www.safemag.ru
1) called to a household
1) called to a household
44
Page 46
28. When you want to call a Guard Station
www.safemag.ru
www.safemag.ru
29. Door Release by Unit Password
45
Page 47
30. Supplement (summary of various programs)
www.safemag.ru
www.safemag.ru
Setting Passwords
1. P–Previous Management Password–E–0–E– New Management Password–E :
Management Password Registration.
P-Previous Building Password-E-1-E-New Building Password-E : Building Password
.
2
Registration
3. K-20-E-Household Unit Number-E-Previous Unit Password-E-New Unit Password-E :
Unit Password Registration
4. P-Management Password-E-16-E-Unit Number-E : Retrieving Unit Password
Retrieving Unit Information
1. P-Management Password-E-14-E : Checking the unit’s interphone status
2. P-Management Password-E-15-E : Unit Number Registration
Building number, Lobby phone number, and Door release function Settings
1. P-Management Password-E-2-E-Building Number-E : Building Number Registration
.
P-Management Password-E-3-E-Lobby Phone Number-E : Lobby Phone Number
2
Registration
3. P-Management Password-E-28-E : Door Release Function enabled/disabled (00:
Installation Flush Mount Type installation
Model DR-2AG/RF1
UTP Cable(ø 0.5)
Wiring
Power Source 12V , 1A
Power Consumption Standby : 135mA, Maximum : 320mA
Call Method Handsfree(one way)
Effective Call Range100m
RF Sensing Range 60mm
Lighting Built-in LED light for night use
Temperature -20°C(tested up to -40°C ) ~ 40°C
Dimensions 130 (W) x 315 (H) x 40 (D) mm
Floor Distributor(common 6 wires),
Security station phone(common 4 wires)
52
Page 54
35. RF-ID Model (Optional)
www.safemag.ru
www.safemag.ru
Communication Device Certification(RF Option)
Model Name DR-2AG/RF1
Frequency 13.56MHz
Antenna power range Under 47.5mV/m within 10 meter radius
Power 12V
Emission Type A1D
Number of Channel 1 Channel
Modulation method ASK
Communication method Simplex Operation Method
Temperature -10°C(tested up to -40°C) ~ +50°C, 95%
53
Page 55
513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea
Int’l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133
Web site : www.commax.com
www.safemag.ru
www.safemag.ru
PM132AGRF110
Printed In Korea / 2013.12.104
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.