Commax CM-810M User Manual

Thank you for purchasing COMMAX products.
Please carefully read this User’s Guide (in particular, precautions for safety)
before using a product and follow instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.
Model No. CM-810M
Open V oice Intercom System
513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int’l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com
Printed In Korea / 2008. 12
1
Contents
1. Greetings
1. Greeting ⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 1
2. Warnings and Caution ⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 2
3. Names and function of each part ⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 4
4.
Operational functions
⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 5
5.
Wiring
⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 6
6. Power Specifications ⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 6
7. Specifications and features ⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯ 8
Instructions for users
The product is registered for electromagnetic compatibility for household use and can be used in all areas including residential areas.
Level-B product
󱄿Thank you very much for purchasing of COMMAX products. 󱄿Please read carefully this user manual and follow its rules. 󱄿This intercom can be used in offices, and shopping outlets, and provide
convenience to use communication on long distances.
2. Warnings and caution
2
3
Please follow the things described below in order to prevent any danger or property damage.
Cleaning & Use
Warning
Caution
Power & Installation
Cleaning & UsePower & Installation
Warning
Warning
Caution
Prohibition.
No disassembly
No touch
Must follow strictly.
Shows plugging out the power cord without an exception
Shows the warning and caution for an electric shock.
Shows the warning and caution for a fire.
It may cause a minor damage or injury if violated.
It may cause a serious damage or injury if violated.
4
5
3. Names and function of each part
4. Operational functions
NO Description
Speaker
FND display unit
Ten key
PRIVACY function
LOCK(Hands-free communication)
TALK(Conversation)
Receiver Volume Control
Call Sound Volume Control Dial
MIC
-1 Name of eac part of CM-810M
4-1 Setting methods before usage and precautions
1) Setting of Melody ID
- If you press for 2 seconds button “ * ”, beep voice will sound and bell sound will enter setting mode.
- Word “Sd (SOUND)”will be shown in Display window, and current number of melody (initial number: 01) will flicker.
- At this moment, if you press 1 or 2, appropriate melody will be in effect.
- After melody is selected, push button “ # ”and finish melody selection.
- By pressing melody selection and button “ # ”, device will be
automatically enter to ID setting mode
- ID in display window, and current ID (initial number: 01) will be
sequentially flickered.
- After setting of ID is done, press “ # ”and setting for use will be over.
2
) Precautions
- Setting of ID should be done from 1 to 10 according to wiring state.
- In order to go over among Melody and ID setting, press “ * ”. (Example): For setting only ID : pressing about 2 seconds button “ * ”+ button “ * ”+ set ID number + button “ # ” For setting only melody: pressing about 2 seconds “ * ”+ Number of setting melody + button “ * ”
- After entering into setting mode, if you do not press any button for 10 seconds, it will automatically go to initial state.
5-2 Master Station_CM-810M How to use, guidelines for CM-810M
*
* When you want to call and begin to talk
1) Press ID number of device to be called and then press button “ # ”.
2) If bell lasts over 1.5 seconds, conversation mode automatically opens.
Example: Calling to ID number 1: press “ 1 + # (Bell sound will occur) ”
- When you press wrong number, error beep sound will occur. (It is possible to call from 1 to 10, and impossible to call into its ID number).
- When you enter wrong number, press “ * ”and it will be annulated.
3) When calling, press Talk button and speak, release Talk Button, when
listening.
When talking is over, press again button「#」and finish conversation.
*
* When you are called from other unit and want to speak
1) If there is a call coming from another unit, you will see in display
window “A(call)”words appear, after 1.5 seconds it get automatically in to speaking mode with appearing of “N”in display.
2) During of transmission it is possible to talk without handling any button.
3) If you press privacy button, it will be impossible to make eavesdropping
over master unit.
Receiver Volume Control: Regulating of voice of opponent, coming from
outside.
Calling Out Volume Control: it regulates volume of calling sound.
PRIVACY Button: when this button is pushed, even under communication, voice of this person will not be transmitted to the other party. (preventing of eavesdropping is possible)
As CM-810M does not have a handset, you should press “Talk”button, during conversation, and press again one more time “Talk”button in order to finish conversation.
6
7
5. Wiring
6. Power Specifications
6. Power Specifications
5-1 Wiring method
-
This product use LINE CORD terminal for wiring.
1) Terminal 10P: It connects with LINE CORD 10P CONNECTOR. Number of this unit will be connected to terminal “L”.
2) Terminal 4P : It connects with LINE CORD 4P CONNECTOR. ( + , - , L1 , L )
** It is recommended to use Adaptor 12V Trans Type.
This product’s composition schema is different by distance of power supply units and quantity of installing intercom units.
6
-1 When we use only one RF-1A(DC12V/1A) (distance 50M)
- In case of usage of 12V/1A as it is in picture, maximum 4 units will be connected.
- It is needed to wire adaptor and first CM-810M at maximum closest way within 1 meter.
- It will possible to wire in parallel way by every 50 meters.
- It is needed to wire adaptor and first CM-810M at maximum closest way within 1 meter.
- A distance between first and second units of CM-810M will be about 100 meters.
6. Power Specifications
6-2 When we use only one RF-1A(DC12V/1A) (Distance 100M)
- It is needed to wire as closest as possible first CM-810M with power within 1 meter.
- Second and third CM-810M should be connected to each other in
parallel way and installed in every 50 meters.
- After installing first CM-810M unit in 100 meters distance from fourth CM-810M unit, turn on second power supply.
- Place fourth unit of CM-810M maximum close to the power supply unit, within 1 meter.
- Place fifth and sixth CM-810M units by 50 meters distance from each other in parallel way.
- Place first CM-810M and power supply unit within 1 meter in wiring.
- Please place first CM-810M and second CM-810M within 200M distance and turn on the power.
- Please install second CM-810M Unit and power supply unit within 1 meter.
When we use two RF-1A (DC12V/1A). (Distance 50M / 100M)
When we use two RF-1A (DC12V/1A). (Distance 50M / 100M)
6-3 When we use two RF-1A (DC12V/1A). (Distance 50M / 100M)
6-4 When we use 2 pieces RF-1A(DC12V/1A) (distance 200M at maximum)
8
- Make wiring distance between first unit of CM-810M and power supply unit within 1 meter.
- Place every CM-810M from first unit to tenth unit, putting them by 20 meters respectively between every unit.
- Turn on second power supply unit, connecting it to fifth CM-810M Unit, which is placed in middle of this structure.
- Wire fifth CM-810M unit by placing it from power unit within 1 meter.
- Turn on third power unit connecting it to the last CM-810M.
- Wire power unit with the last CM-810M within 1 meter.
1) Master between master communication.
2) Nice voice quality.
3) Hands-free communication.
4) High degree of sensitivity.
5)
Privacy function prevents eavesdropping from others in the intercom system.
6) Offered with 3-call, 5-call channels(supporting up 6, or 10 stations).
7) Notify you of incoming calls with an electronic tone and an LED that indicates calling station.
8)
Build your system with one or more master stations up to 10stations.
6-5 When we use 3 pieces of RF-1A(DC12V/1A) (distance 20M)
7-1 Technical Specifications
7-2 Features
7. Specifications and features
Item Description
Wir e CM-810M : 14 wires (Talking 10 wires, Power 2 wires, L & L1)
Power Source DC12V 1A / RF-1A
Transmission way Half duplex communication
Display Unit FND Power Consumption Stand by : 50mA
Maximum : 100mA
Communication Maximum 200m (Ø0.65mm)
Distance