The Command Access MLP-UL-M-KIT is a field installable motorized latch-pullback kit for the
MARKS 8800 & 9900 series devices.
A.B.C.
D.
E.
Kit IncludesTools Required
1- Motor Mount w/ MM4S series module
A.
2- 8/32 X 1/4” Phillips head screws
B.
1- 8’ Lead w/ VD Connector
C.
1- Push & go connector
D.
1- MM4S switch program sticker
E.
1- Dogging Hole Cap
F.
E.F.G.
Cordless Drill
Hammer & Pin Punch(recommend) or 3/16 drill bit
5/16 Nut driver (recommended) or Flat head screwdriver
#2 Phillips head screwdriver
Install VIdeo
Command Access Technologies | 22901 La Palma Ave, Yorba Linda, CA 92887 | Phone:(888) 622-2377
#20094_I
Page 2
mm4s switches
on
off
on
off
onon
off
off
LOW TORQUE
STANDARD TORQUE
HIGH TORQUE
PTS PROGRAMMING LOCKED
Technical Information
SPECIFICATIONS
• Input Voltage: 24VDC +/- 10%
• Wire gauge: Minimum 18 gauge
• Direct wire run - no relays or
access control units in-between
power supply & module
Setting PTS
**Important Info**
Make sure to set PTS before finishing installation
MM4s VIdeo
Low Torque Mode
Average Latch Retraction Current: 600 mA
Average Holding Current: 150 mA
Standard Torque Mode
Average Latch Retraction Current: 900ma
Average Holding Current: 215 mA
High Torque Mode
Average Latch Retraction Current: 2 Amp
Average Holding Current: 250 mA
Step 1-
Select your preferred torque mode (ships in standard torque) Press the device push pad to the
desired setting. (Recommend to fully depress and release 5%, giving the device room for changing door
conditions.)
Step 2-
Step 3-
While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped, release the pad
and now the adjustment is complete. If not to your liking repeat the 3 steps.
Troubleshooting & Diagnostics
BeepsExplanationSolution
2 Beeps
3 Beeps
4 BeepsFailed SensorVerify all 3 sensor wires are installed correctly. Replace sensor if problem persists
5 Beeps
6 Beeps
Over Voltage
Under Voltage
Retraction or dogging failure
PUSH TO SET
> 30V unit will shut down. Check voltage & adjust to 24 V.
< 20V unit will shut down. Check voltage & adjust to 24 V.
by contacting office.
After 1st fail: 5 beeps then immediately attempts to retract again.
After 2nd fail: 5 beeps with pause in-between for 30 seconds then device
attempts to retract again.
After 3rd fail: 5 beeps every 7 minutes, device will not attempt to retract.
To Reset: Depress bar for 5 seconds at any time.
Device is recording it’s new position and power mode after the 6th beep.
US CUSTOMER SUPPORT1-888-622-2377 | WWW.COMMANDACCESS.COM | CA CUSTOMER SUPPORT 1-855-823-3002
Page 3
Ceiling Tile
Electrified Exit Device
Installation Example
CAT
NORMALLY OPEN
DRY CONTACT FROM
ACCESS CONTROL
SYSTEM
NO VOLTAGE
LOCKING
HARDWARE
Module
Legend
Standard Placement
+
-
GREEN
CHANNEL 1
LED
Optional Placement
Retrofit 2-pin Connector
The new 2-pin connector is used when retrofitting a older Command or
Von Duprin installation so you can plug in to the exisiting connector.
New
Exisitng
PUSH N’ GO Connector
STRIPE WIRE 1/8”-3/16” 7 INSERT INTO WIRE ACCESS HOLES OF CONNECTOR.
WIRE ACCESS
WIRE RELEASE
Recommended Power Supplies:
All Command Access exit devices & field installable kits have been thoroughly
cycle tested with Command Access power supplies at our factory.
For more information click here or go to our website
US CUSTOMER SUPPORT1-888-622-2377 | WWW.COMMANDACCESS.COM | CA CUSTOMER SUPPORT 1-855-823-3002
Page 4
Installation Instructions
Remove End Cap & Filler Plate
1.
Partially slide push pad off approx. 2-3”
3.
Remove (4) screws from baserail
B.
2.
Using 5/32” drill bit. Open up the (2) back screw holes #3 & 4.
4.
Continue sliding push pad half way out of the base rail so activating bracket is accessible. Next, remove metal rod
5.
and AB mount can be put aside.
Activating Bracket
BaserailMetal Rod
AB Mount
US CUSTOMER SUPPORT1-888-622-2377 | WWW.COMMANDACCESS.COM | CA CUSTOMER SUPPORT 1-855-823-3002
Page 5
CONTINUED
Attach the link assembly to the end of the activating bracket. Next,
6.
place activating bracket into center of the motor mount.
Link Assembly
Re-install metal rod securing activating bracket to motor mount.
8.
Secure link assembly to activating bracket
7.
with Hex wrench provided.
Slide push pad with motor kit back into the device. Also, the filler plate must be slid in at same time. Make sure
9.
Latch retractor is pressed down so push pad slides over it.
US CUSTOMER SUPPORT1-888-622-2377 | WWW.COMMANDACCESS.COM | CA CUSTOMER SUPPORT 1-855-823-3002
Page 6
CONTINUED
Re-install original screws in holes 1 & 2. Install new screws
10.11.
provided in holes 3 & 4.
Next, plug in the push & go connector into the MM4S. Add
12.
program sticker to back of the device.
13.
Connect your VD 8’ lead (CAT or VD retrofit) or you can
remove the VD connector to hardwire- take stripped wire
end and push into the push & go connector
Add program sticker to back of the device.
E.
Setting PTS
Step 1-
Step 2-
Step 3-
Step 4-
US CUSTOMER SUPPORT1-888-622-2377 | WWW.COMMANDACCESS.COM | CA CUSTOMER SUPPORT 1-855-823-3002
Select your preferred torque mode (ships in standard torque) Press the device push pad to the
desired setting. (Recommend to fully depress and release 5%, giving the device room for
changing door conditions.)
While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped,
release the pad and now the adjustment is complete. If not to your liking repeat the three
steps.
Once you found the correct location, flip the dip switches to off to lock programming.
mm4s switches
off
on
off
LOW TORQUE
STANDARD TORQUE
HIGH TORQUE
PTS PROGRAMMING LOCKED
on
off
on on
off