Command access ML01, ML04, ML03, ML05 Installation Instructions Manual

Page 1
Installation Instructions
Bridge Rectifier
Bridge Rectifier
Mortise Lock Pocket
Mortise Lock Pocket
Mortise Lock Pocket
3/8 Wire Raceway
ETH Hinge Pocket
Bridge Rectifier
Bridge Rectifier
Plug
Mortise Lock Pocket
Mortise Lock Pocket
Mortise Lock Pocket
3/8 Wire Raceway
ETH Hinge Pocket
Bridge Rectifier
Wire Transfer Hinge
Bridge Rectifier
Plug
3/8 Wire Raceway
Mortise Lock Pocket
Mortise Lock Pocket
Mortise Lock Pocket
Bridge Rectifier
Mortise Lock Pocket
ML01/ML03/ML04/ML05
Corbin Russwin Lock modied by Command Access Technologies
STEP 1: The door must be machined with a 3/8” wire raceway,
mortise lock pocket & prepped for a energy transfer hinge. Make sure the mortise pocket is free of debris.
Mortise Lock Pocket
3/8 Wire Raceway
: Run the wires from the ETH hinge through the 3/8”
raceway starting at the ETH hinge & exiting into the mortise pocket.
: Screw the ETH hinge to the door. At this time DO NOT
Mortise Lock Pocket
3/8 Wire Raceway
ETH Hinge Pocket
Wire Transfer Hinge
connect the hinge wires on the jamb side to the wires coming from the power supply.
STEP 4: Connect the wires exiting the mortise pocket to the
Bridge Rectier (included).
Mortise
Lock Bridge Rectifier
: Connect the Bridge Rectier to the plug exiting the
Pocket
mortise chassis.
Mortise Lock Pocket
Bridge Rectifier
Plug
: Carefully slip the connected mortise lock chassis into the
mortise pocket paying close attention not to pinch any wires.
: Mount the chassis per manufacturer’s instructions.
STEP 8: Connect the wires from the power supply at the ETH
hinge on the jamb side. Connect the hinge to the jamb.
LEGEND OF TERMS
EU
: (Fail Secure) When power is applied, the outside trim will unlock. When
power is removed, the outside trim is locked.
: (Fail Safe) When power is applied, the outside trim will lock. When
EL
power is removed, the outside trim is unlocked.
REX
: (Request to Exit Switch) Monitors the inside handle.
or
Power Supply
or
Power Supply
DPS: (Door Position Switch) Monitors the door position via the anti pick
(Deadlatch).
LBM
: (Latchbolt Monitor Switch) Monitors the position of latchbolt.
Bridge Rectifier
Bridge Rectifier
Energy Transfer Hinge
Energy Transfer Hinge
Switch
EU (Fail Secure)
Switch
EL (Fail Safe)
12VAC/DC
24VAC/DC
12VAC/DC
24VAC/DC
EU (Fail Secure)
EL (Fail Safe)
Command Access Technologies | 22901 La Palma Ave. Yorba Linda, CA 92831 | Phone: (888) 622-2377 | www.CommandAccess.com
Command Access Technologies is not a licencee, aliated, associated or connected with Corbin Russwin or any of their subsidiaries or aliates.
ELECTRICAL SPECIFICATIONS
SOLENOIDS:
VOLTS
24VAC/DC 12VAC/DC
CURRENT
350mA 700mA
SWITCHES: 5A 124VAC/DC
: Green - Common (C)
REX
Blue - Normally Open (NO) Gray - Normally Closed (NC)
LBM
: Green/Black - Common (C)
: Green/Red - Common (C)
DPS
Blue/Black - Normally Open (NO) Gray/Black - Normally Closed (NC)
Blue/Red - Normally Open (NO) Gray/Red - Normally Closed (NC)
COIL RESISTANCE
69 Ohms +/- 10% 18 Ohms +/- 10%
Page 2
Handing Instructions for ML01/ML03/ML04/ML05 Mortise Locks
STEP 1: Move the RED Locking Screw to side of lock-body being
locked.
: Push in latch then depress catch plate with screw driver.
STEP 3: Pull latch out of lock-body and rotate 180°.
MAKE SURE CATCH PLATE IS
EVEN WITH TOP SURFACE
GOOD BAD
RED Locking Screw
STEP 4: Push in latch while holding screw driver behind latch
tail. Note: Push in latch until catch plate is no longer depressed.
: Rotate lock front to match bevel of door.
Rotate 180 Deg.
2.75”
Template for ML01/ML03/ML04/ML05 Mortise Locks
1-5/16” diameter
cylinder hole for exterior
through hole
3/8” diameter
through hole
7/8” diameter
3/8” diameter
through hole
1.5”
.75”
2.125”
side only
2.25”