ComfortStar CCH009CA-410, CCH012CA-410, CCH009CD-410, CCH012CD-410 Owner's Manual

OWNER'S MANUAL
Air Conditioner
Models:
CCH009CA-410
CCH012CA-410
CCH mini-splits -
13 SEER
CCH009CD-410 CCH012CD-410
■ ................................1
....................................4
■ . ......................5
■ .....................6
■ ...................................1
■ ...................................1
■ .........................
■ ..................................2
■ .................................2
■ .................2
■ ...............................1
CONTENTS
Operation and maintenance
Notices for operation
Notices for use
Names and functions of each part
Operation of wireless remote control
Clean and care
Troubleshooting
Installation service
Notices for installation
Installation dimension diagram
Install indoor unit
Install outdoor unit
Check after installation and test operation
.......................2
Wiring diagram outdoor unit ...
...
Wiring diagram indoor unit
.......................20
...
...
This symbol stands for the items
should be forbidden.
This symbol stands for the items
should be followed.
..............2
Installation and Maintenance of Healthy Filter
The products in this manual may be different with the real one, according to different models, some models have displayer and some models without displayer, the position and shape of the displayer please refer to the real one.
Some description about heating function in this Instruction Manual is only valid for the
cooling and heating unit.
19
.....................
11
Emergency Operation
.... ....
The air conditioner should be
operated with the voltage range
when the voltage is very low, the compressor vibrates terribly and that will damage the refrigerant system; When the voltage is very high, the electrical component
would be easily damaged.
that is the rated voltage 10%,
Operation and maintenance-Notices for operation
Please read the following carefully before operating.
WARNING
When having a burning smell
or smoke, please turn off the power supply and contact with the service
may be damaged, and may cause
center.
If the abnormity still exists, the unit
electric shock or fire.
Don't operate the air conditioner
with wet hands.
Otherwise, it can cause an electric shock or fire.
Never cut off or damage power cables and control wires. If the power cable and signal control wire were
damaged, change them by professional
Power must adopts the special
circuit to prevent fire.
Otherwise, it can cause an electric shock or fire.
Be sure to cut off power supply as the air conditioner not in use for
a long time.
Otherwise, the accumulated dusts that may cause overheating or fire.
Never damage the electric wire
or use the electric wire, which is not
appointed.
Otherwise, it will cause overheating
or fire.
When cleaning, it is necessary to stop driving and turn off the power supply.
Cut off power supply
Otherwise, it may cause electric
shock or damage.
The power supply must adopt
the special circuit that with air switch
protection and assure it has enough capacity. The unit will be turned on or off according to your requirement
automatically, please do not turn on
or turn off the unit frequently, othe-
rwise disadvantage effect may be caused to the unit.
5℃
Earth:The ground
be connected!
If not, please ask the qualified person­nel to install. Furthermore, don't conn­ect each wire to the gas pipe, water
pipe, drainage pipe or any other impr-
oper places.
Select the most appropriate tem-
perature.
It can preclude the electricity wasted.
Keep room coo-
er than outside
about
Don't leave windows and
doors open for a long time
while operating the air conditi­oner.
Don't block the air intake or outlet
vents of both the outdoor and indoor
units.
Keep combustible spray away
from the units more than 1m.
It can cause afire or explosion.
It can decrease the air conditioning
capacity or cause a malfunction.
It can decrease the air conditioning capacity.
Please note whether the install-
ed stand is firm enough or not.
If it is damaged, it may lead to the fall of the unit and cause the injury.
As falling off the outdoor unit can be dangerous.
Don't step on the top of the
outdoor unit or place something
on it.
Don't attempt to repair
the air conditioner by yourself.
The wrong repair will lead to
an electric shock or fire, so
you should contact the service
centerto repair.
Notices for operation
Be sure to pull out the power plug when not using the air co­nditioner for a long time.
Otherwise, the accumulated dust
may cause fire or electric shock.
Don't blow the wind to animals and plants
directly. It can cause a bad influence to them.
Don't insert your hands or stick into the air
intake or outlet vents.
Splashing water on the air conditioner can
cause an electric shock and malfunction.
Don't place a space heater near the air
conditioner.
Or CO toxicosis may occur for imcomplete burning.
Don't apply the cold wind to the body for a
long time.
It can cause the health problems.
Don't use the air conditioner for other purposes,
such as drying clothes, preserving foods, etc.
The power cords of this air conditioner adopt
Y-type connection, please don't cut off or damage the power cords and control cords. If they are
damaged, please ask the qualified personnel to change them.
To adjust the airflow and direction appropriately.
At operating the louvers of air conditioner could be
adjusted by pressing the SWING button on wireless
remote control to change the airflow direction.
Notices for operation
Guide louver
109.4
69.8
64.4
Working principle and special functions for cooling
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature.
Anti-freezing function
If the unit is running in COOL mode and in low termperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0, the indoor unit microcomputer will stop compressor running and protect the unit.
The conditions of unit can't normally run
The following temperature range protection device may act, that may cause stop running.
Under the relative humidity above 80%( doors and windows opened) when cooling or dihu­midifying for a long time, there will be dew drip off near the air vent.
"COOL"
running
"DRY"
running
Outdoor temp above
Indoor temp. below
Indoor temp. below
Notices for use
F
F
F
Air in
Air out
Indoor Unit
Outdoor Unit
(1) Front Panel (2) Guide louver (3) (4) (5)
Wall Pipe
(6)
Wrapping Tape Indoor & outdoor
cable
Drainage pipe
Wireless remote control
Names and functions of each part
Air in
Air out
CoolDryFan
Heat
S
et temp.
Run
T
he pattern in displayer
CCH009CA-410 CCH009CD-410
CCH012CA-410 CCH012CD-410
遥控器各按键的名称及作用
Names and functions of wireless remote control
ON/OFF button
ON/OFF
Remote control
Signal transmitter
AUTO COOL
DRY FAN HEAT
(only for cooling and heating unit)
Don't drop or throw the remote control; Don't let any liquid in the remote control and
Note: Be sure that there are no obstructions between receiver and remote controller;
Middle fan
put the remote control directly under the sunlight or any place where is very hot.
Press this button, Auto, Cool,Dry, Fan,
Heat mode can be selected circularly.
MODE button
MODE
Auto mode is default while power on. Under Auto mode,the temperature will not be displayed; Under Heat mode, the initial value is 28
;Under other
modes,
the initial value is 25
Press this button, Sleep On and Sleep Off can be selected. After powered on,Sleep
SLEEP button
SLEEP
Off is defaulted. After the unit is turned off, the Sleep function is canceled. After Sleep function set up, the signal of Sleep will display. In this mode, the time of timer can be adjusted. Under Fan and Auto modes, this function is not available.
Press this button, Auto, Low, Middle, High
speed can be circularly selected. After
FAN button
FAN
powered on,Auto fan speed is default. Under Dehumidify mode, Low fan speed only can be set up.
Low fan
High fan
Press this button, the clock can be set up,
signal blink and display.Within 5
CLOCK button
CLOCK
seconds, the value can be adjusted by pressing + or - button, if continuously press this button for 2 seconds above, in every 0.5 seconds, the value on ten place of Minute will be increased 1. During blinking, repress the Clock button, signal will be constantly displayed and it denotes the setting succeeded. After powered on, 12:00 is defaulted to display and signal will be displayed. If there is signal be
value is Clock value, otherwise is Timer value.
displayed that denotes the current time
TEMP button
TEMP
Operation of wireless remote control
F)
82
F)
77
Press this button, the unit will be turned on, press it once more, the unit will be turned
off. When turning on or turning off the unit,
the Timer, Sleep function will be canceled, but the presetting time is still remained.
Press this button, can set up temperature: presetting temperature (to display room),
indoor ambient temperature (to display indoor temperature), outdoor ambient temperature (to display outdoor temperature), and that will go around. It is defaulted that
there is no signal displaying. Remark:when operating this button,the wireless remote
control displays the presetting temperature all along.
Remote control
X-FAN button
X
TURBO button
TURBO
Press this button at unit On or Off status,
Light On and Light Off can be set up.
LIGHT button
LIGHT
After powered on, Light On is defaulted.
+ button
+
Presetting temperature can be decreased.
Press this button, the temperature can be
- button
-
set up, continuously press this button
and hold for two seconds, the relative contents can quickly change, until unhold this button and send the order that the (oF)signal will be displayed all the time. The temperature adjustment is unav­ailable under the Auto mode, but the order can be sent by if pressing this button.
Names and functions of wireless remote control
Operation of wireless remote control
Press this button, can turn on or turn off
the drying.In Cool and Dehumidifying mode,
this button," " will be concealed, at this time the X-FAN function is turned off. After powered on, X-FAN OFF is defaulted.
When operating the ON/OFF button, or switching mode to Cool or Dehumidifying mode,the X-FAN function will keep the original status. If unit is turned off, X-FAN OFF only can be set up and send the signal. In Auto, Fan as well as Heat mode, X-FAN function can not be set up and there is no " " displaying.
press this button and will display " ", at this time the X-FAN is turned on. If repress
In Cool or Heat mode, press this button
can turn on or turn off the Turbo function.
After turned on the Turbo function, its signal will be displayed. When switching the mode or changing fan speed, this function will be canceled automatically.
For presetting temperature increasing.
Press this button,can set up the temperature, when unit is on . Continuously
press and hold this button for more than 2 seconds, the corresponding contents will be
changed
rapidly, until unpress the button
℃(℉)
laying all along. In Auto mode, the temp­erature can not be set up, but operate this button can send the signal. Centigrade setting range :16-30; Fahrenheit scale setting range 61-86.
then send the information, is disp-
with multifunction; For some function, which the model dosen't have, if press the
corresponding button on the remote controller that the unit will keep the original
running
status.
Notice: This is a general use remote controller, it could be used for the air conditioners
X-FAN
SWING UP AND DOWN BUTTON
TIMER ON
TIMER ON BUTTON
Timer On setting: Signal “ON” will blink and display, signal will conceal, the numerical section will become the timer on setting status. During 5 seconds blink, by pressing or button to adjust the time value of numerical section, every press of that button, the value will be increased or decreased 1 minute. Hold pressing or button, 2 seconds later, it quickly change, the way of change is: During the initial 2.5 seconds, ten numbers change in the one place of minute, then the one place is constant, ten numbers change in the tens place of minute at 2.5 seconds speed and carry. During 5s blink, press the Timer button, the timer setting succeeds. The Timer On has been set up, repress the timer On button, the Timer On will be canceled. Before setting the Timer, please adjust the Clock to the current actual time.
TIMER OFF BUTTON
Once press this key to enter into
TIMER OFF setup, in which case the TIMER OFF icon will blink. The method of setting is the same
TIMER OFF
as for TIMER ON.
Remote control
Names and functions of wireless remote control
Operation of wireless remote control
OFF
This is an universal use remote controller. If remote controller sends the following three kinds of status that the swing status of main
unit will be:
When the guide louver start to swing up and down, if turn off the Swing, the air guide louver will stop at current position.
which indicates the guide louver swings up
and down between that all five positions.
with multifunction; For some function, which the model dosen't have, if press the corresponding button on the remote controller that the unit will keep the original
running status.
Notice: This is a general use remote controller, it could be used for the air conditioners
Press this button, to set up swing angle, which circularly changes as below:
Loading...