•Refer to Service Manual RS6200004 for installation, operation, and troubleshooting information.
•All safety information must be followed as provided in the Service Manual.
•Refer to the appropriate Parts Catalog for part number information.
•Models listed on page 3.
®
C
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures performed by an unqualified person.
The model and manufacturing number are used for positive identification of component parts used in manufacturing.
Please use these numbers when requesting service or parts information.
GMVC80704CXAA
PRODUCT
TYPE:
G: Goodman®
A: A m ana®
Brand Gas
SUPPLY TYPE:
C: Counterflow/
Horizontal
D: Dedicate
Down flow
M: Upflow/
Horizontal
arising from improper service or service procedures. If
you install or perform service on this unit, you assume
responsibility for any personal injury or property damage
which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.
Disconnect ALL power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury or death.
Goodman will not be responsible
for any injury or property damage
2
HIGH VOLTAGE!
WARNING
WARNING
viduals meeting the requirements of an "entry level technician", at a minimum, as specified by the Air-Conditioning,
Heating, and Refrigeration Institute (AHRI). Attempting to
install or repair this unit without such background may
result in product damage, personal injury or death.
Installation and repair of this unit
should be performed
ONLY by indi-
Page 3
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please
use these numbers when requesting service or parts information.
AMVC80704BXAA
AMVC80905CXAA
AMVC81155CXAA
AMVC80704BXAB
AMVC80905CXAB
AMVC81155CXAB
ADVC80703BXAA
ADVC80905CXAA
ADVC81155CXAA
GMVC80704BXAA
GMVC80905CXAA
GMVC81155CXAA
GMVC80704BXAB
GMVC80905CXAB
GMVC81155CXAB
WARNING
WARNING
WARNING
WARNING
Serious property damage, personal injury, reduced unit
performance and/or hazardous conditions may result
from the use of such non-approved devices.
The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow
these regulations may harm the environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
Do not connect or use any device
that is not design certified by
Goodman for use with this unit.
WARNING
WARNING
do not store combustible materials or use gasoline or
other flammable liquids or vapors in the vicinity of this
appliance.
To prevent the risk of property
damage, personal injury, or death,
3
Page 4
PRODUCT DESIGN
General Operation
Models covered by this manual come with a new 4-wire communicating PCB. When paired with a compatible communicating indoor unit and a CTK01AA communicating thermostat, these models can support 4-wire communication protocol and provide more troubleshooting information. These
models are also backward compatible with the legacy thermostat wiring.
The ADVC8, AMVC8, and GMVC8 furnaces are equipped
with an electronic ignition device to light the burners and an
induced draft blower to exhaust combustion products.
An interlock switch prevents furnace operation if the blower
door is not in place. Keep the blower access doors in place
except for inspection and maintenance.
These furnaces are also equipped with a self-diagnosing electronic control module. In the event a furnace component is
not operating properly, the control module's dual 7-segment
LED's will display an alpha-numeric code, depending upon
the problem encountered. These LED's may be viewed
through the observation window in the blower access door.
Refer to the Troubleshooting Chart for further explanation of
the LED codes and Abnormal Operation - Integrated Igni-tion Control section in the Service Instructions for an explanation of the possible problem.
The rated heating capacity of the furnace should be greater
than or equal to the total heat loss of the area to be heated.
The total heat loss should be calculated by an approved
method or in accordance with “ASHRAE Guide” or “Manual
J-Load Calculations” published by the Air Conditioning Contractors of America.
*Obtain from: American National Standards Institute 1430
Broadway New York, NY 10018
Location Considerations
•The furnace should be as centralized as is practical
with respect to the air distribution system.
•Do not install the furnace directly on carpeting, tile, or
combustible material other than wood flooring.
•When suspending the furnace from rafters or joists,
use 3/8" threaded rod and 2” x 2” x 1/8” angle as
shown in the Installation and Service Instructions. The
length of the rod will depend on the application and
clearance necessary.
•When installed in a residential garage, the furnace
must be positioned so the burners and ignition source
are located not less than 18 inches (457 mm) above
the floor and protected from physical damage by vehicles.
WARNING
O PREVENT POSSI BL E PE RSONAL I NJ URY OR DEAT H D UE TO ASPHYXIATI ON,
T
THI S FURNACE MUST BE
CATEGORY III VENTI N G.
Notes:
1. Category I Venting is venting at a non-positive pressure.
A furnace vented as Category I is considered a fan-assisted appliance and the vent system does not have to
be “gas tight.”
NOTE: Gas furnaces with induced draft blowers draw
products of combustion through a heat exchanger allowing,
in some instances, common venting with natural draft
appliances (i.e. water heaters).
All installations must be vented in accordance with National
Fuel Gas Code NFPA 54/ANSI Z223.1 - latest edition. In
Canada, the furnaces must be vented in accordance with
the National Standard of Canada, CAN/CSA B149.1 and
CAN/CSA B149.2 - latest editions and amendments.
NOTE: The vertical height of the Category I venting system
must be at least as great as the horizontal length of the
venting system.
2. Line voltage wiring can enter through the right or left side
of the furnace. Low voltage wiring can enter through the
right or left side of furnace.
3. Conversion kits for propane gas and high altitude natural
and propane gas operation are available. See High Altitude Derate chart for details.
Accessibility Clearances (Minimum)
Unobstructed front clearance of 24" for servicing is recommended.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS - INCHES
SidesTopRearFront*
1036 11
* 24" clearance for serviceability recommended.
** Single Wall Vent (SW) to be used only as a conncetor.
Refer to the venting tables outlined in the Installation Manual for
additional venting requirements.
Note: In all cases accessibility clearance shall take precedence over clearances from the enclosure where accessibility clearances are greater. All dimensions are given in inches.
ATEGORY I VENTED. DO NOT VENT USING
C
Vent
SWB
4
Page 5
PRODUCT DESIGN
A
D
Alcove Illustration
REAR
S
I
E
D
I
S
LCOVE
24" at front is required for servicing or cleaning.
Note: In all cases accessibility clearance shall take
precedence over clearances from the enclosure where
accessibility clearances are greater. All dimensions are
given in inches.
High Altitude Derate
When this furnace is installed at high altitude, the appropriate High Altitude orifice kit must be installed. This is required due to the natural reduction in the density of both the
gas fuel and combustion air as altitude increases. The kit
will provide the proper design certified input rate within the
specified altitude range.
High altitude kits are purchased according to the installation altitude and usage of either natural or propane gas. Refer
to the chart above for a tabular listing of appropriate altitude
ranges and corresponding manufacturer’s high altitude Natural Gas and Propane Gas kits. For a tabular listing of appropriate altitude ranges and corresponding manufacturer's High
Altitude Pressure Switch kits, refer to either the Pressure
Switch Trip Points & Usage Chart in this manual or the Accessory Charts in Service Instructions.
D
E
Single Stage Thermostat
A single-stage thermostat with only one heating stage may
be used to control this furnace. The application of a singlestage thermostat does not offer “true” thermostat-driven twostage operation, but provides a timed transition from low to
high fire. The furnace will run on low stage for a fixed period
of time before stepping up to high stage to satisfy the
thermostat’s call for heat. The delay period prior to stepping
up can be set at either a fixed 5 minute time delay or a load
based variable time between 1 and 12 minutes (AUTO mode).
If the AUTOmode is selected, the control averages the cycle
times of the previous three cycles and uses the average to
determine the time to transition from low stage to high stage.
To use a single-stage thermostat, turn off power to the furnace, move the thermostat selection DIP switch to the OFF
position. Set the desired transition time by setting the transition delay DIP switch to the desired ON/OFF position. Turn
power back on. Refer to the following figure.
Heat OFF Delay
DIP Switches
ON OFF
3
4
Thermostat
Stage Delay
S1
Move to the ON position
to select two-stage
thermostat or OFF to
select single stage
thermostat
Move to the ON position
to select A u to transition
delay or OFF for 5 minute
transition delay
INPUT PER BURNER - 22, 500 BTUH NATURAL GAS / 20,000 BTUH L.P.
ELEVATION ABOVE SEA-LEVEL (FEET)
20003000400045005000600070008000
US BUR NER
O RIF IC E
CANADA BURNER
O RIF IC E
HA-02 HIGH ALTITUDE CONVERSION KIT REQUIRE
Tabled data is based upon the furnace input being reduced for altitudes above sea level. U.S. 4% per 1,000 feet.
Canada 10% derate for 2,000-4,000 feet.
10 Gas Manifold
11 Inshot Burner
12 Transformer
13 Integrated Control Module
14 Blower Door Interlock Swtich
15 Circulator Blower
16 Gas Line Entrance (Alternate)
17 Inductor
7
Page 8
PRODUCT DIMENSIONS
Alt. Gas Inlet
AMVC8/GMVC8_____X*
Alt. Gas Inlet
High Voltage Inlet
Low Voltage
MODELSAB
AMVC80704BX **
GMVC80704BX**
17-1/216
Alt. High Voltage
Alt. LowVoltage
All dimensions ar e in inches.
8
AMVC80905CX**
AMVC81155CX**
GMVC80905CX **
GMVC81155CX **
2119-1/2
Page 9
PRODUCT DIMENSIONS
A
28”
High Voltage
Electrical
Low Voltage
Electrical
ADVC8_____X*
B
Gas Inlet
33-3/8”
MODELAB
ADV C80703 B X**17 1/216S B T17
NON-COMBUSTIBLE
FLOOR BASE
ADVC80905CX**
ADVC81155CX**
2119 1/2S B T21
All dim ens ions are in inc hes .
9
Page 10
PRODUCT DESIGN
PRESSURE SWITCH TRIP POINT S
AND USAGE CHART
SQUARE NOSE
MODEL
AMVC800704BX**
GMVC8070 4BX**
AMVC80905CX**
GMVC80905CX**
AMVC81155CX**
GMVC81155CX**
ADVC80703BX**
ADVC80905CX**
ADVC81155CX**
TRIP POINT
ID BLOWER
PRESSURE SW ITCH -
LOW STAGE
-0.30-0.650130F00049
-0.30-0.600130F00050
-0.30-0.600130F00050
-0.30-0.55B1370210
-0.30-0.55B1370210
-0.30-0.55B1370210
TRIP POINT
ID BLOWER
PRESSURE SWITCH -
HIGH STAGE
ID BLOWER
PRESSURE
SW ITCH
PART #
PRI M ARY LIM IT
Part Num b e r0130M 0006320162904201629030130F 000670130F 00071
Op en Settin g (°F )
AMVC80704BX**
GMVC80704BX**
AMVC80905CX**
GMVC80905CX**
AMVC81155CX**
GMVC81155CX**
140150160190200
------1------
1------------
---1---------
ADVC80703BX**
ADVC80905CX**
ADVC81155CX**
RO LLO UT L IM IT S W ITC HES
Part Num ber10123529
O p e n S e t t in g ( ° F )
AMVC80704BX**
GMVC80704BX**
AMVC80905CX**
GMVC80905CX**
AMVC81155CX**
GMVC81155CX**
ADVC80703BX**
ADVC80905CX**
ADVC81155CX**
---------1---
---------1---
------------1
10
300
2
2
2
1
1
1
AUXILIARY LIMIT SW ITCHES
Part Num ber0130F00038
O p e n S e tting (° F)
AMVC80704BX**
GMVC80704BX**
AMVC80905CX**
GMVC80905CX**
AMVC81155CX**
GMVC81155CX**
ADVC80703BX**
ADVC80905CX**
ADVC81155CX**
120
1
1
1
1
1
1
Page 11
PRODUCT DESIGN
Coil Matches:
A large array of Amana® brand coils are available for use with the ADVC8 furnaces, in downflow applications, and with
AMVC8 and GMVC8 furnaces, in either upflow or horizontal applications. These coils are available in both cased and
uncased models (with the option of a field installed TXV expansion device). These 80%+ furnaces match up with the
existing Amana® brand coils as shown in the chart below.
Coil Matches (for Goodman® and Amana® Brand units using R22 and R-410A):
CAPF1824A6A
PRODUCT
TYPE:
C: Indoor Coil
APPLICATION
A: Up fl ow/D ownflow Coil
H: Hor izont al A C oil
S: Ho r izont al Slab Co il
EXPANSION
DEV ICE:
F: Flowrater
CAB INET F INIS H:
U: Unpainted
P: Pai nted
N: Unpai nted Ca se
N OMI NAL CAP ACI TY RA NGE
@ 13 SEER
18 24: 1 1/2 t o 2 Tons
30 30: 2 1/2 To ns
36 36: 3 Tons
36 42: 3 to 3 1/ 2 Tons
37 43: 3 to 3 1/ 2 Tons
48 60: 4 & 5 Tons
49 61: 4 & 5 Tons
REVISION
A: Revisio n
REFRIGERANT
CHARGE:
6 : R- 410A or R - 2 2
2: R- 22
4: R- 410a
NOMINAL WI DT H FO R GAS FURNACE
A: Fits 14 " F ur nace Cabine t
B: Fits 17 1/2" Fu r nace Cabi n et
C: Fits 21" Furnace Cabinet
D: Fits 24 1/2" Furnace Cabinet
N : Do es Not Apply (Horizonta l Slab Coils)
• All CAPF coils in B, C, & D widths have insulated blank off plates for use with one size smaller furnaces.
• All CAPF coils have a CAUF equivalent.
• All CHPF coils in B, C & D heights have an insulated Z bracket for use with one size smaller furnace.
• All proper coil combinations are subject to being ARI rated with a matched outdoor unit.
11
Page 12
PRODUCT DESIGN
Thermostats:
ComfortNet™ CTK01A* Thermostat Kit
Filters:
Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or
CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty
Upflow Filters
Return air filters may be installated at the furnace side and/or bottom return openings. The furnace bottom return opening
and side openings will accommodate the following filter sizes depending on cabinet size:
Side Re turn Open ing(s)Bottom Re turn Opening
Cabinet
Width
(in.)
Nominal
Filter Size
(in.)
Approx.
Flow A rea
2
(in
)
Cabinet
Width
(in.)
Nominal
Filter S iz e
(in.)
All16 x 25 x 14001412 x 25 x 1300
17-1/214 x 25 x 1350
2116 x 25 x 1400
24-1/220 x 25 x 1500
Approx.
Flow Area
(in2)
Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere in
the duct system such as a central return.
MINIMUM FILTER SIZES
FURNACE INPUTFILTER SIZETYPE
45M
70M
90M
115M
140M
45M
70M
90M
115M
140M
PERMANENT NOMINAL 600 F.M. FACE VELOCITY
DISPOSABLE NOMINAL 300 F.M. FACE VELOCITY
160 in
241 in
320 in
400 in
370 in
320 in
483 in
640 in
800 in
738 in
Return air filters may be installated at the at the downflow top return. A field supplied center filter support must be provided
by the installer in order to use the top return. The furnace will accommodate the following downflow top return filter sizes
depending on cabinet size:
Cou nte r flow Top Retu rn
Optional
Access
Door
Return Air
"A"
Min
Cabinet Width
17 1/214.2
2113.0
24 1/211.3
17 1/219.7
2118.8
24 1/217.7
17 1/225.0
2124.3
24 1/223.4
Filter Area
2
(in
)
600215 X 20 X 1
800220 X 20 X 1
1 000225 X 20 X 1
Qty
Filter Size
(in)
Dimension "A"
(in)
Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere
in the duct system such as a central return.
13
Page 14
FURNACE SPECIFICATIONS
AMVC8
MODEL
Bt uh Input (US) High Fire70,00090,000115,000
Out put (US) High F ire5 7,00074,00093,000
Bt uh Input (US) Low Fire49,00063,00080,000
Out put (US) Low F ire39,20050,40064,000
A. F.U .E .80%80%80%
Rated Ex ternal S tatic (" w.c.).10 - .50.10 - .50.10 - .50
Temperature Rise (°F)20 - 5020 - 5025 - 55
High S tage P ress ure Sw itch Trip Point (" w.c .)-0.65-0.60-0.60
Low S tage P ress ure S witch Trip P oint (" w.c .)-0.30-0.30-0.30
Blowe r W heel (D" x W")10 x 810 x 1010 x 10
Blowe r Horsepower3/43/43/4
Blowe r Speeds
Max CFM @ 0.5 E.S.P.
Pow er Supply115-60-1115-60-1115-60-1
M inimum C ircuit A m pac ity (M CA )12.112.112.1
M ax imu m Overc urrent Device151515
Trans former (VA)404040
Heat Anticipator (A m ps)0.70.70.7
Prim ary Lim it S etting (°F)160140150
A ux iliary Limit S et ting (°F)120120120
Rollout Lim it Set ting (°F)300300300
Fan Delay On Heating 30 secs.30 secs.30 secs.
Off Heating *150 secs .150 s ecs .150 s ecs .
Fan Delay On Cooling 5 secs.5 secs.5 secs.
Off Cooling 45 secs.45 secs.45 secs.
Fan Delay On - Fan Only 5 secs.5 secs.5 secs.
Gas S upply P ress ure (Natural/Propane) (" w.c .)7 / 117 / 117 / 11
M anifold P ress ure (Natural/Propane) High St age (" w.c .)3.5 / 103.5 / 103.5 /10
M anifold P ress ure (Natural/Propane) Low S tage ("w.c .)1. 9 / 6.01.9 / 6. 01.9 / 6.0
Orific e S ize (Natural/Propane)#43 / #55#43 / #5 5#43 / #55
Number of B urners345
Vent Connect or Diameter (inches)444
Shipping W eight (lbs.)138156156
AM V C80070 4BX ** AMV C80905C X **AM V C8 1155CX **
Refer t o airflow ch arts in this m anual.
* Off Heating - This fan delay timing is adjustable (90, 120, 150 or 180 seconds), 150 seconds as shipped.
1. These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation.
2. For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice
changes should only be made if necessary for altitude.
3. The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the
"A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total
heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times
output.
Btuh Input (US) High Fire70,00090,000115,000
Output (US ) High Fire57,00074,00093,0 00
Btuh Input (US) Low Fire49,00063,00080,000
Output (US ) Low Fire39,20050,40064,000
A.F .U.E .80%80%80%
Rated E x ternal Static (" w.c.).10 - .50.10 - .50.10 - .50
Temperature Rise (°F)20 - 5020 - 5025 - 55
High S tage P ressure S witch Trip P oint (" w.c.)-0.65-0.60-0.60
Low Stage Pressure Switch Trip Point (" w.c.)-0.30-0.30-0.30
B lower W heel (D" x W ")10 x 810 x 1010 x 10
Blower Hors epower3/43/43/4
B lower Speeds
Max CFM @ 0.5 E.S.P.
P ower Supply115-60-1115-60-1115-60-1
M inimum Circuit A m pacity (M C A )12.112.112.1
M axim um O vercurrent Device151515
Trans form er (VA )404040
Heat A nticipator (A m ps )0.70.70.7
P rim ary Lim it Setting (°F)160140150
A uxiliary Limit S etting (°F )120120120
Rollout Limit S etting (°F)300300300
Fan Delay On Heating 30 secs.30 secs.30 secs.
Off Heating *150 sec s .150 s ecs .150 se cs .
Fan Delay On Cooling 5 secs.5 secs.5 secs.
Off Cooling 45 sec s .45 sec s.4 5 sec s.
Fan Delay On - Fan Only 5 secs.5 secs.5 secs.
Gas S upply P ress ure (Natural/P ropane) (" w.c .)7 / 117 / 117 / 11
M anifold P ressure (Natural/P ropane) High Stage (" w.c.)3.5 / 103.5 / 103.5 /10
M anifold P ressure (Natural/P ropane) Low Stage ("w.c.)1.9 / 6.01.9 / 6.01.9 / 6.0
Orifice Size (Natural/Propane)#43 / #55#43 / #55#43 / #55
Num ber of Burners345
V ent Connec tor Diameter (inches)444
Shipping W eight (lbs.)138156156
GMVC 80704BX ** GM V C 80905CX ** GM V C1155 CX **
Refer to airflow charts in this m anua l.
* Off Heating - This fan delay timing is adjustable (90, 120, 150 or 180 seconds ), 150 seconds as shipped.
1. These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation.
2. For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice
changes should only be made if necessary for altitude.
3. The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the
"A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total
heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times
output.
Bt uh Input (US ) Hig h F i re70,00090,000115, 000
Output (US ) High Fire56,00072,00092,000
Bt uh Input (US) Low Fi re51,00063,00080,500
Output (US ) Low Fire40,80050,40064,400
A.F . U.E .80%80%80 %
Rated E x t ernal S t at ic (" w. c . ).10 - .50.10 - .50. 10 - . 50
Temperature Ris e (°F)30 - 6035 - 6535 - 65
High St age P res sure S wit c h Trip Poi nt (" w. c . )-0.55-0.55-0. 55
Low St age P res s ure S wit c h Trip Point (" w. c . )-0.30-0.30-0. 30
Blower Wheel (D" x W" )10 x 810 x 1010 x 10
Blower Hors epower3/ 43/43/4
Blower S peeds
Max CFM @ 0.5 E.S.P.
Power S upply115-60-1115-60-1115 -60-1
Minimum Circuit Ampacity (MCA)12.112.112.1
Max im um O vercurrent Device151515
Transformer (VA)404040
Heat A ntic i pat or (Amp s )0.70.70.7
Prim ary Lim i t S e t ti ng (°F)1901 90200
Aux il iary Li m it S et t ing (°F)120120120
Rollout Li m it S et t ing (°F)300300300
Fan Delay On Heating 30 secs.30 secs.30 secs.
Off Heating *150 secs .150 secs.150 secs.
Fan Delay On Cooling 5 secs.5 secs.5 secs.
Off Cooling 45 secs.45 secs.45 secs.
Fan Delay On - Fan Only 5 secs.5 secs.5 secs.
Gas Supply Pres s ure (Natural / P ropane) (" w. c . )7 / 117 / 117 / 11
Manifold P res s ure (Nat ural/ P ropane) High St age (" w. c . )3.5 / 103.5 /103.5 /1 0
Manifold P res s ure (Natu ral/ P ropane) Low S t age ("w. c . )1. 9 / 6. 01.9 / 6. 01. 9 / 6. 0
Orifice S i z e (Natu ral/Propane)#43 / #55#43 / #55#43 / #55
Number of Burners345
Vent Connec t or Diam et er (inc hes )444
Shipping Weight (lbs. )112124130
ADVC80703BX**ADVC80905CX**ADVC81155CX**
Refer to airflow charts in this manual.
* Of f Heating - This fan delay timing is adjustable (90, 120, 150 or 180 seconds), 150 seconds as shipped.
1. These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation.
2. For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice
changes should only be made if necessary for altitude.
3. The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the
"A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total
heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times
output.
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed
as needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM maximum.
17
Page 18
BLOWER PERFORMANCE SPECIFICATIONS
AMVC8/GMVC8
AMVC80704 BX**
GMVC80704BX**
Cooling
Speed Tap
High (Single) Stage Cooling Speed Charts
AMVC80905CX**
GMVC80905CX**
Adj ust
Tap
CFM
Cooling
1
Spe e d Tap
Adj ust
Tap
CFM
Minus (-)540Minus (-)720Minus (-)720
A
Normal600Normal800Normal800
A
Plus (+ )660Plus (+ )880Plus (+ )880
Minus (-)720Minus (-)990Minus (-)990
B
Normal800Normal1100Normal1100
B
Pl us (+ )880P lus (+ )1210Pl us (+ )1210
Mi nus (-)990M inus (-)1260Mi nus (-)1260
C
Normal1100Normal1400Normal1400
C
Pl us (+ )1210Pl us (+ )1540Pl us (+ )1540
Mi nus (-)1260Minu s (-)1620Minus (-)16 20
D
Normal140 0Normal1 800Norm al18 00
D
Pl us (+ )1540Pl us (+ )1980Pl us (+ )2,000 *
AMVC8/GMVC8 Low Stage Cooling Speed Charts
Cooling
1
Speed Tap
A
B
C
D
AMVC81155CX**
GMVC81155CX**
Adjust
Tap
CFM
1
AM VC80704 BX**
GMV C807 04 BX**
Cooling
Speed Tap
Adj u st
Tap
CFM
1
Minus (-)351Minus (-)468Minus (-)468
A
Normal390Normal520Normal520
Pl us (+ )429Plus (+ )572Pl us (+ )572
Minus (-)468Minus (-)644Minus (-)644
B
Normal520Normal715Normal715
Pl us (+ )572Plus (+ )787Pl us (+ )787
Minus (-)644Minus (-)819Minus (-)819
C
Normal715Normal910Normal910
Pl us (+ )787Plus (+ )1001P l us (+ )1001
Mi nus (-)819M inus (-)105 3M i nus (-)1053
Normal910Normal117 0Normal1170
Pl us (+ )1001P lus (+ )1287P l us (+ )1287
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed
as needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM maximum.
18
AMVC80905CX* *
GMVC80905CX**
Cooling
Speed Tap
A
B
Adjust
Tap
CFM
1
Speed Tap
AMVC8115 5CX**
GMVC81155CX**
Cooling
A
B
Adjust
Tap
CFM
CC
D
DD
1
Page 19
BLOWER PERFORMANCE SPECIFICATIONS
p
p
AMVC8/GMVC8
Continuous Fan Speed Chart
Continous Fan Speeds
Model
AMVC800704BX**
GMVC80704BX**
AMVC80905CX**
GMVC80905CX**
AMVC81155CX**
GMVC81155CX**
1
Continuous fan speed is 30% of furnace maximum CFM
2
Three continuous fan speeds are pos sible with the
Furnace
Ma x imu m CFM
1760530
2000600
2000600
Co ntinu ous Fan
eed
1,2
S
C TK01AA thermostat : 30%, 50%, and 70% of furnace
maximum C FM
ADVC8 Continuous Fan Speed Chart
Continous Fan Speeds
Model
Furnace
Ma x imu m CFM
Co ntinu ous Fan
1,2
S
eed
ADVC80703BX**1760530
ADVC80905CX**2000600
ADVC81155CX**2000600
1
Continuous fan speed is 30% of furnace maximum CFM
2
Three continuous fan speeds are pos sible with the
C TK01AA thermostat : 30%, 50%, and 70% of furnace
maximum C FM
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed
as needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM maximum.
19
Page 20
BLOWER PERFORMANCE SPECIFICATIONS
ADVC8 Heating Speed Chart
ADVC80703BX **
(Rise Ran g e : 30° - 60°F)
Heating
Speed
Tap
AA
BB
CC
DD
Adju st
Tap
Minus (-)66094555Minus (-)850121555
Normal735105049Normal945135049
Plus (+ )810115545Plus (+ )1040148545
Minus (-)725103550M inus (-)915130551
Normal805115045Normal1015145046
Plus (+ )885126541Plus (+ )1115159542
Minus (-)790112546M inus (-)975139548
Normal875125041Normal1085155043
Plus (+ )960137538Plus (+ )1195170539
Minus (-)850121543M inus (-)1040148545
Normal945135038Normal1155165040
Plus (+ )1040148535P lus (+)1270181537
(Rise Ran g e : 35° - 65°F)
Low -
Stage
CFM
ADVC81155CX **
High-
Stage
CFM
Rise (°F)
Heating
Speed
Tap
ADVC80905CX **
(Rise Ran g e : 30° - 60°F)
Adju st
Tap
Low-
Stage
CFM
High-
Stage
CFM
Rise (°F)
Heating
Speed
Tap
A
B
C
D
Adju st
Tap
Minus (-)975139561
Normal1085155055
Plus (+ )1195170550
Minus (-)1040148557
Normal1155165052
Plus (+ )1270181547
Minus (-)1105157554
Normal1225175049
Plus (+ )1350192544
Minus (-)1135162053
Normal1260180047
Plus (+ )1385198043
Low -
Stage
CFM
High-
Stage
CFM
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed
as needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM maximum.
20
Rise (°F)
Page 21
BLOWER PERFORMANCE SPECIFICATIONS
(+)
(+)
)
ADVC8High (Single) Stage Cooling Speed Charts
ADVC 80703C X**AD V C 809 05C X* *ADVC81 155C X**
Coolin g
Speed Tap
Adjust
Tap
CFM
Cooling
1
Spe ed Tap
Adjust
Tap
Mi nus (-)540Mi nus (-)720Minus (-)765
AAA
Normal600Normal800Normal850
Plus (+)660P lus (+)880Plus (+)935
Mi nus (-)720Mi nus (-)990Minus (-)1035
BBB
Normal800Normal1100Normal1150
Plus (+)880Plus (+)1210P lus (+)1265
Mi nus (-)900Mi nus (-)1260Minus (-)1305
CC
Normal1000Normal1400Normal1450
Plus (+)1100Plus (+)1540Plus (+)1595
Mi nus (-)1080Minus (-)1620Minus (-)1665
DD
Normal1200Normal1800Normal1850
Plus
1320Plus (+)1980P lus (+)2,000*
ADVC8 Low Stage Cooling Speed Charts
ADVC80703CX**ADVC80905CX**
Cooling
Speed Tap
Adjust
Tap
CFM
Cooling
1
Speed Tap
Adjust
Tap
CFM
CFM
Cooling
1
Speed Tap
Cooling
1
Speed Tap
Adjust
Tap
C
D
ADVC81155CX**
Adjust
Tap
CFM
CFM
1
1
Minus ( -)351Minus (-)468Minus (-)497
Normal390Normal520Normal553
Plus (+)429Plus (+)572Plus (+)608
Minus ( -)468Minus (-)644Minus (-)673
BB
Normal520Normal715Normal748
Plus (+)572Plus (+)787Plus (+)822
Minus ( -)585Minus (-)819Minus (-)848
CC
Normal650Normal910Normal943
Plus (+)715Plus (+)1001Plus (+)1037
Minus ( -)702Minus (-)1053Minus (-)1082
DD
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed
as needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM maximum.
Normal780Normal1170Normal1203
Plus
858Plus (+)1287Pl us (+
AAA
B
C
D
1323
21
Page 22
BLOWER PERFORMANCE SPECIFICATIONS
NOFF
Circulator Blower Speed Adjustment Switches
Switch Bank: S3
Cooling Speed
Taps
AOFFOFF
BONOFF
COFFON
D*ONON
(*Indicates factory setting)
DIP S w itch No .
12
Switch Bank: S3
A djust Taps
Normal*OFFOFF
10%ONOFF
-10%OFFON
NormalONON
(*Indicates f actory setting)
DIP Sw itch No.
34
Note: There are dual 7-segment LED's adjacent
to the selection dipswitches. The airflow rounded
to the nearest 100 CFM, is displayed on the dual
7-segment LED's. The CFM display alternates
with the operating mode.
Example:
If the airlfow demand is 1230 CFM, the LED's will
display 12. If the airflow demand is 1275 CFM,
the LED's will display 13.
Switch Bank: S4
Heating Speed
Taps
AOFFOFF
B*ONOFF
COFFON
DONON
(*Indicates factory setting)
DIP Sw itch No.
78
Dehumidification Enable Switch
O
9
10
S5
DEHUM
Unused
Move to the ON position
to enable dehumidification
Note: Continuous fan speed will be 30% of the
furnace's maximum airflow capability. If the furnace maximum CFM capaibility is 1760 CFM, the
continuous fan speed will be 0.30 X 1760 CFM =
530 CFM.
Example: If the furnace maximum CFM capaibility
is 1760 CFM, the continuous fan speed will be
0.30 X 1760 CFM = 530 CFM.
Note: The optional usage of a dehumidistat allows
the furnace’s circulator blower to operate at a slightly
lower speed (85% of desired speed) during a combined
thermostat call for cooling and dehumidistat call for
dehumidification. This can be done through an
independent dehumidistat or through a thermostat’s
DEHUM terminal (if available). This lower blower speed
enhances dehumidification of the conditioned air as it
passes through the AC coil. For proper function, a
dehumidistat applied to this furnace must operate on
24 VAC and utilize a switch which opens on humidity
rise.
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed
as needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM maximum.
22
Page 23
BLOWER PERFORMANCE SPECIFICATIONS
Ramping Profile
Switc h Bank: S4
Ramping
Profiles
A*OFFOFF
BONOFF
COFFON
DONON
(*Ind i cates facto ry setting )
DIP Switch No.
56
OFF
Profile A: provides only an OFF delay of one (1) minute at
100% of the cooling demand airflow.
Note: The multi-speed circulator blower also offers several
custom ON/OFF ramping profiles. These profiles may be
used to enhance cooling performance and increase comfort
level. The ramping profiles are selected using DIP switches
5 and 6. Refer to the following figure for switch positions
and their corresponding taps. Refer to the bullet points below
for a description of each ramping profile. Verify CFM by
noting the number displayed on the dual 7-segment LED
display.
100% CFM100% CFM
OFF
1 min
OFF
Profile B: ramps up to full cooling demand airflow by first
stepping up to 50% of the full demand for 30 seconds. The
motor then ramps to 100% of the required airflow. A one (1)
minute OFF delay at 100% of the cooling airflow is provided.
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed
as needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM maximum.
50% CFM
1/2 min
100% CFM
100% CFM
OFF
1 min
23
Page 24
BLOWER PERFORMANCE SPECIFICATIONS
Ramping Profile
OFF
Profile C: ramps up to 82% of the full cooling demand airflow
and operates there for approximately 7 1/2 minutes. The motor
then steps up to the full demand airflow. Profile C also has a
one (1) minute 100% OFF delay.
OFF
100% CFM
OFF
OFF
Profile D: ramps up to 50% of the demand for 1/2 minute,
then ramps to 82% of the full cooling demand airflow and
operates there for approximately 7 1/2 minutes. The motor
then steps up to the full demand airflow. Profile D has a 1/2
minute at 50% airflow OFF delay.
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed
as needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM maximum.
24
Page 25
PERFORMANCE
MPER
RE R
÷ CFM
130140150
900
FORMULAS
BTU OUTPUT = CFM x 1.08 x RISE
1.08
BTU OUTPUT
RISE =
100
2400 CFM
2200
2000
1800
1600
1400
1200
1100
1000
OUTPUT BTU/HR x 1000
800
90
700
80
BTU OUTPUT vs TEMPER ATURE RISE CHART
600 CFM
100
70
30405060708090110120
60
ISE
50
ATU
TE
40
30
20
10
25
Page 26
WIRING DIAGRAMS
A
A
A
A
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MUL TIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
2
1
BK
WH
3
I
H
WH
2
C
1
PM
*MVC8***AA Models
TO
/
5
C
1
1
V
A
1
P
P
S
P
O
R
W
GND
P
R
CTI
E
E
O
T
ON DEV
C
JUNCTION BOX
B
24V HUM.
YL
C
O
N
C
NO
YL
K
WH
YL
TO 115VAC/ 1
Ø /60 HZ POWER SUPPLY WITH
OVERCURRENT PROTE
H
LY WI
T
U
D
T
O
N
EVI
C
E
I
ICE
PU
PU
PU
3
2
R
D
1
A
B
U
NER COM
R
O
B
WER COM
L
WH
24 V
O
DEHUM
P
R
P
A
H
T
ERMOSTAT CO
Y2
Y1
T
TM
E
N
T
TME
N
R
AUTO RESET
AUXILIARY
LIMIT CONTROL
E
N
N
CTION
S
2
1
G
W1
R
C
W2
RD
BK
DIAGNOSTIC
WH
LED'S
BK
1
2
3
4
1
2
3
4
WH
M
E
0
RD
R
T
S
S
G
B
CIRCULATOR
BLOWER
F
0
0
5
L
B
Y
4
K
3
2
1
6
0
6
WH
M
C
E
N
HAR
NOTES:
1. SE T HEAT ANTI CIPATOR ON RO
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE
USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRE A S S UP P L IE D WITH THE
FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH
WIRING MATERIAL HA VING A TEMPERATURE RATING OF AT
LEAST 105°C. USE COPPER CONDUCTORS ONL Y.
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFOR
N.E.C. AND LOCAL CODES.
5. TO RECALL THE LAST 6 FAUL TS, MO ST RECENT TO LEAST
RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE
IN STANDBY (NO THERMOSTAT INPUTS)
1
4
0
DIP SWITCHES
5
4
3
2
1
OM THERMO
R
E
2ND STG DLY
T-ST AT
HEAT OFF
DELAY
UNUSED
DEHUM
HEAT
DELAY
DJUST
COOL
S
F
NEUTRAL
BK
GR
PK
STAT AT 0.7 AMPS.
.
A
V
SEE
NOTE 5
OR
3
6
9
12
15
YL
LINE
HUM
WH
M T
O
2
5
8
11
14
GND
RD
FUSE
YL
1
4
7
10
13
WH
BK
EAC
PU
4
2
V
A
3
RD
RD
YL
RD
BR
B
L
BL
WH
B
K
INDUCTOR COIL
70kBTU,90kBTU,
115kBTU MODE LS
ONLY
COLOR CODES:
PK PINK
BR BROWN
WH WHITE
BL BLUE
GY GRAY
RD RED
Y
O
PU PURPLE
GN GREEN
BK BLACK
CHASSIS GROU ND
DISCONNECT
YL
OR
YL
GN
WH
YL
RD
BR
BL
WH
BK
BLOWER
COMPARTMENT
DOOR SWIT CH
(OPEN WHEN
DOOR OPEN)
B
K
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (115
L
HI VO
L
L
E
O
Y
L
W
G
R
OR
A
E
N
INTERN
INTEGRAT
PLUG CONNECTION
DOOR
SWITCH
INDUCTO
70kBTU,90kBTU,
115 kBTU MODELS
E
LIN
INTEGRATED CO NTRO L MODULE
LINE
FUSE 3 A
R
TO
24V THERMOSTAT CONNECTIONS
Y1
W1
W2
TO
MICRO
Y2
G
O
D
E
H
U
M
24V HUM.
C
O
T
R
T
O
O
MIC
R
INTEGRATED CONTROL MODULE
V)
E
F
G
A
T
IELD
JUNCTION
E
T
R
M
I
A
N
TO
AL
NTROL
ED CO
+
L
ONLY
V
EAC
HUM
IGN
D
R COI
IND HI
IND LO
FS
TH (4)
C
HLO (10)
PSO (7)
PS1 (2)
2
P
S
HIGH FI RE
PRESS. SWTICH
HLI (1)
MVL (1 3)
MVH (14)
MVC (8)
GND (5)
TR (11)
D
N
G
+ VDC
(
X
R
X
(
T
JUNCTION BOX
L
INDOOR
CIRCULATOR
BLWR
ELECTRONIC
IR CLEANE R
ID
BLWR
HUMIDIFIER
HOT SURFACE
IGNITER
FLAME SENSOR
24V HUM.
NO
)
2
1
(
4
)
(
1
(
)
2
)
C
)
3
F
HUMID
I
I
E
EQUIPMENT GND
SWITCH (TEMP.)
SWITCH (PRESS
IR
115 VAC
40 VA
TRANSFORMER
24 VAC
NO
C
GND
I
N
R
O
O
D
AIR
L
U
C
R
I
T
O
R
BLWR
R
FIELD G
FIELD SPLICE
I
N
G
I
C
R
E
V
URR
O
PROT. D EVICE
GND
NEUTRAL
NEUTRAL
NEUTRAL
NEUTRAL
NEUTRAL
NEUTRAL
LOW FIRE PRESS.
SWITCH
C
ND
R
T
E
.)
T
N
E
GAS
VALVE
INTEGRATED CONTROL M ODUL E
PM
HI
C
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
26
Page 27
WIRING DIAGRAMS
A
A
A
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MUL TIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
*MVC8***AB, *DVC8***AA Models
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
TO
GND
115 VAC / 1
Ø /60 HZ
POWER SUPPLY W ITH
OVERCURRENT
PROTECTION DEVICE
WARNING:DISCONNECT
POWER BEFORE
SERVICING. WIRING
TO UNIT MUST BE
PROPERLY POLARIZED
AND GROUNDED.
GND
N
DISCONNECT
GND
NEUTRAL
NEUTRAL
NEUTRAL
NEUTRAL
NEUTRAL
NEUTRAL
40 VA
TRANSFORMER
AUTO RESET PRIMARY
LIMIT CONTROL
LOW FIRE PRESS.
SWITCH
C
NO
C
MANUAL RESET ROLLOUT
LIMIT CONTROLS
GAS
VALV E
GND
INDOOR
AIR
BLWR
FIELD GND
IGNITER
I
N
T
E
G
R
A
T
E
D
C
O
N
T
R
O
L
M
O
D
U
L
E
PM
HI
C
YL
FLAME
SENSOR
OR
YL
WH
YL
BL
24
VAC
115
VAC
40 VA
TRANSFORMER
WH
BK
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
LOW VOLTAGE ( 24V)
LOW VOLTAGE FIELD
HI VOLTAGE (115V)
HI VOLTAGE FIELD
INTEGRATED CONTROL
JUNCTION BOX
BK
WH
TO 115VAC/ 1
WARNING:
DISCONNECT POWER
BEFORE SER VICING.
WIRING TO UNI T
MUST BE PROPERLY
POLARIZED AND
GROUNDED .
CHASSIS GROUND
GN
I
N
T
E
G
R
A
T
E
D
C
O
N
T
R
O
L
M
O
D
U
L
E
R
Y1
2
4
V
T
H
E
R
W1
M
O
S
T
W2
T
C
O
N
Y2
N
E
C
T
G
I
O
N
S
O
DEHUM
2
4
V
H
U
M
C
.
BK
TO
R
MICRO
INTEGRATED CONTROL MODULE
JUNCTION
TERMINAL
INTERNAL TO
PLUG CONNE CTION
L
N
DISCONNECT
Ø /60 HZ POWER SUPPLY WITH
OVERCURRENT PROTECTION DE VICE
DOOR
SWITCH
INDUCTOR CO IL
70kBTU,90kBTU,
115kB TU MOD ELS
LINE
LINE
FUSE 3 A
TO +VDC
TO
MICRO
TO
ONLY
EAC
ELECTRONIC
AIR CLEANER
IND HI
IND LO
HUM
HUMIDIFIER
IGN
HOT SURFACE
FS
FLAME SENSOR
TH (4)
AUTO RESET AUXILIARY L IMIT
CONTROLS
HLO (10)
PSO (7)
PS1 (2)
PS2 (12)
HIGH FIRE
PRESS. SWTICH
HLI (1)
MVL (13)
MVH (14)
MVC (8)
GND (5)
TR (11)
GND (4)
+ VDC (1)
RX (2)
TX (3)
HUMIDIFIER
L
JUNCTION BOX
INDOOR
AIR
CIRCULATOR
BLWR
ID
BLWR
IGNITER
115 VAC
24 VAC
24V HUM.
NO
CIRCULATOR
EQUIPMENT GND
FIELD SPLICE
SWITCH (TEMP.)
SWITC H (PRESS.)
OVERCURRENT
PROT. DEVICE
ID BLOWER TWO-STAGE PRESSURE
SWITCH ASSEMBL Y
24V HUM.
C
NO
YL
AUTO RESET
AUXILIARY
LIMIT CONTROL
R
C
YL
RD
PU
INDUCED
DRAFT
BLOWER
GND
FUSE
1
2
2
1
BK
WH
HOT
SURFACE
IGNITER
2 CIRCUIT
CONNECTOR
TWO STAGE
GAS VALVE
(HONEY WELL)
WH
LOW FIRE
PRESSURE
SWITCH
2
HI
3
BL
C
1
PM
MANUAL RESET ROLLOUT LIMIT
LIMIT CONTROL
3
WH
2
RD
1
BK
CONTROLS
PU
AUTO RESET PRIMARY
BURNER COMPARTMENT
BLOWER COMPARTMENT
24 V THERMOSTAT CONNECTIONS
W2
DEHUM
W1
Y2
Y1
O
WH
BR
PU
G
RD
BK
DIAGNOSTIC
WH
RD
LED'S
INTEGRATED
T
W
CONTROL
MODULE
O
-
S
T
G
E
4 CIRCUIT MOTOR
1
CONNECTOR
2
3
4
5 CIRC UIT CONNEC TOR
1
2
3
4
5
BL
GY
4
BK
3
2
1
CIRCULATOR
BLOWER
WH
BK
WH
ECM MTR
HARNESS
NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE
USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH
WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT
LEAST 105 C. USE COPPER CONDUCTORS ONLY.
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO
N.E.C. AND LOCAL C ODES.
5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST
RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE
IN STANDBY (NO THERMOSTAT INPUTS)
DIP SWITCH ES
2ND STG DLY
T-STAT
HEAT OFF
DELAY
UNUSED
DEHUM
HEAT
DELAY
ADJUST
COOL
FS
NEUTRAL
5
4
3
2
1
BK
GR
PK
SEE
NOTE 5
OR
HUM
WH
YL
2
1
3
6
4
5
9
7
8
10
12
11
15
13
14
WH
YL
LINE
BK
E
C
GND
C
NO
PU
24 V
3 A
RD
RD
YL
RD
BR
BL
BL
BK
INDUCTOR COIL
70kBTU,90kBTU,
115kBTU MODELS
ONLY
COLO R CODES:
PK PINK
BR BROWN
BL BLUE
GY GRAY
RD RED
PU PURPLE
GN GREEN
BK BLACK
HIGH FIRE
PRESSURE
SWITCH
YL
RD
BR
RD
WH
WH WHITE
YL YELLOW
OR ORANGE
0140F00660 REV. A
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
27
Page 28
SCHEMATICS
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MUL TIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
INTEGRATED CONTROL MODULE
HUM
Y2
DE
Y1
Y2
DEHUM
Y1Y1O
Y21DEHUM
R
W2
W1
C
GO
2
G
W2
R
W1
C
2O
W2
W1
G1
2
R
C
1
1
3
6
9
12
15
4
7
10
13
ST5
INDUCTOR COIL
GND
TX
RX
12V
ST4
FS
WH
IGN-N
IND-N
IND-LO
IND-HI
IGN
BK
R
ANSI Z21 .20 AU TOMATIC IGNITIO N SYST EM 24VAC 60Hz 0 .8 A. M AX.
EAC
HUM
BK
WH
59-4715 R EV. F
LINE
LOAD
TRANSFORMER
ADVC8/AMVC8/GMVC8_____X* MODEL FURNACES
This schematic is for reference only. Not all wiring is as shown above,
refer to the appropriate wiring diagram for the unit being serviced.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
28
CONTROL ASSEMBLY SCHEMATIC
Page 29
SCHEMATICS
Y2
O
W2
W1
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MUL TIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
XFMR
G
DEHUM
P
μ
C
4
8
R
Y112
6
N/C
122
DIPSWX
334
TX/RX
1
VARIABLE SPEED
CIRCULATOR
HI
2
LO
3
INDUCER
4
EAC
RJ11
P
μ
RS485
COMM
COMM
STATUS LED
DU AL LED
DIS PLAY S
71593
101
PS2
PS1
N/C
AUXRLSHL
TYPICAL SCHEMATIC
14
WR 50C51-289 INTEGRATED IGNITION CONTROL
ADVC8/AMVC8/GMVC8_____X* MODEL FURNACES
HUM
15
IGN
ZCNTL
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
DRAIN
SWITC H
LOHI
138
GAS VALVE
5-11
GROU ND
WIRING SCHEMATIC
This schematic is for reference only. Not all wiring is as shown above. Refer to the appropriate wiring diagram for the unit being serviced.
29
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.