Comfort Glow (VENT-FREE) GAS STOVE HEATER, SL30NT Series Owner's Operating & Installation Manual

Page 1
Save this manual for future reference.
For more information, visit www.desatech.com
WARNING: If the information in this manual is not fol­lowed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
WARNING: This SL30PT/NT series vent-free gas log heater is only approved for use in the Comfort Glow series cast iron stove models CISC and CISG.
(VENT-FREE) GAS STOVE HEATER
OWNER’S OPERATION AND
INSTALLATION MANUAL
MODELS SL30PT AND SL30NT SERIES THERMOSTAT CONTROL
GAS LOG HEATER (BURNER SYSTEM FOR CAST IRON STOVES)
Page 2
www.desatech.com
115580-01A
2
WARNING: Improper installation, adjustment, altera­tion, service or maintenance can cause injury or prop­erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi­tional information consult a qualified installer, service agency or the gas supplier.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provi­sions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation section on page 5 of this manual.
This appliance may be installed in an aftermarket,* per­manently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indi­cated on the rating plate. This appliance is not convert­ible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for bedroom and bathroom installation in the Common
-
wealth of Massachusetts.
TABLE OF CONTENTS
Safety Information ............................................... 3
Product Identification ...........................................
4
Local Codes ........................................................ 4
Product Features ................................................. 5
Air For Combustion and Ventilati
on ..................... 5
Installation ........................................................... 7
Operating Heater ............................................... 15
Inspecting Burners ............................................ 16
Cleaning and Maintenance ................................ 17
Troubleshooting .................................................
18
Specifications ....................................................
21
Service Hints ..................................................... 21
Technical Service .............................................. 21
Replacement Parts ............................................ 21
Accessories ....................................................... 21
Illustrated Parts Breakdown and Parts List ....... 22
Parts Centrals .................................................... 26
Warranty Information ............................ Back Page
Page 3
www.desatech.com
115580-01A 3
SAFETY INFORMATION
WARNING: This product con­tains and/or generates chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate or service this heater. Improper use of this heater can cause seri
­ous injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon
monoxide poisoning resemble the flu, with head
-
aches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.
Natural and Propane/LP Gas: Natural and propane/
LP gases are odorless. An odor-making agent is added to these gases. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warn
­ings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
WARNING: Any change to this heater or its controls can be dangerous.
WARNING: Do not allow fans to blow directly into the stove. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.
WARNING: Do not use a blower insert, heat exchanger insert or other accessory not ap­proved for use with this heater.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.
Stove becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing igni­tion. Heater will remain hot for a time after shutdown. Allow sur
-
face to cool before touching.
Carefully supervise young chil­dren when they are in the room with fireplace.
Keep the appliance area clear and free from combustible ma
-
terials, gasoline and other flam
-
mable vapors and liquids.
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2. Do not place propane/LP supply tank(s) in
­side any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use
any phone in your building
• immediately call your gas supplier from a
neighborʼs phone. Follow the gas supplierʼs instructions
• if you cannot reach your gas supplier, call
the fire department
Page 4
www.desatech.com
115580-01A
4
4. This heater shall not be installed in a bedroom or bathroom.
5. Do not place stove directly on carpeting, vinyl tile or any combustible material other than wood. The stove must set on a metal or wood panel extending the full width and depth of the appliance.
6. Do not use this stove as a wood burning fire
­place. Use only model SL30PT or SL30NT vent-free gas log heater.
7. Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting.
8. This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person.
Note: During
initial operation, slight smoking could occur due to log curing and heater burning manu­facturing residues.
9. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 17.
10. Before using furniture polish, wax, carpet cleaners or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.
11. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen De
­pletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 5. If heater keeps shutting off, see Troubleshooting, page 18.
12. Do not run heater
• where flammable liquids or vapors are used
or stored
• under dusty conditions
13. Do not use this stove to cook food or burn paper or other objects.
14. Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
15. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime­sized or larger).
SAFETY INFORMATION
Continued
16. Turn heater off and let cool before servicing. Only a qualified service person should service and repair heater.
17. Operating heater above elevations of 4,500 feet could cause pilot outage.
18. To prevent performance problems, the use of a propane/LP tank of less than 100 lb. capacity is not recommended (propane/LP units only).
19. Provide adequate clearances around air openings.
PRODUCT
IDENTIFICATION
Figure 1 - Typical Stove Cabinet Model
with Comfort Glow Gas Log Heater
Stove Body
Stove Door (Shown in the open position)
Piezo Ignitor
Control Knob
One Piece Log Set Inside Stove Cavity
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the lat­est edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Page 5
www.desatech.com
115580-01A 5
PRODUCT FEATURES
OPERATION
This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.
SAFETY PILOT
This heater has a pilot with an Oxygen Deple­tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system re­quires no matches, batteries or other sources to light heater.
AIR FOR COMBUSTION
AND VENTILATION
WARNING: This heater shall not be installed in a confined space or unusually tight con­struction unless provisions are provided for adequate combus
­tion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Todayʼs homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy effi
­cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three fol
-
lowing ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 5 through 7 will help you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the out
­side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and
b. weather stripping has been added on
openable windows and doors and
c. caulking or sealants are applied to areas
such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumb
­ing, electrical and gas lines and at other openings.
If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors
,
page 7. If your home does not meet all of the
three criteria above, proceed to
Determin-
ing Fresh-Air Flow For Heater Location
,
page 6.
Page 6
www.desatech.com
115580-01A
6
Confined and Unconfined Space
The National Fuel Gas Code ANSI Z223.1/NFPA 54 defines a confined space as a space whose
volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m
3
per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m
3
per kw) of the aggregate input rating of
all appliances installed in that space. Rooms com
­municating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with door
­less passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length x
width x height).
Length x Width x Height = cu. ft. (volume
of space)
Example: Space size 20 ft. (length) x 16 ft.
(width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is sup
-
plied with grills or openings, add the volume of these rooms to the total volume of the space.
2. Multiply the space volume by 20 to determine
the maximum Btu/Hr the space can support.
(volume of space) x 20 = (maximum Btu/Hr
the space can support)
Example: 2560 cu. ft. (volume of space) x 20 =
51,200 (maximum Btu/Hr the space can support)
AIR FOR COMBUSTION
AND VENTILATION
Continued
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free heater _________
Btu/Hr
Gas water heater* _________
Btu/Hr
Gas furnace ________
Btu/Hr
Vented gas heater ________
Btu/Hr
Gas fireplace logs ________
Btu/Hr
Other gas appliances* + ________
Btu/Hr
Total = ________
Btu/Hr
* Do not include direct-vent gas appliances.
Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Example:
Gas water heater ________
Btu/Hr
Vent-free heater + ________
Btu/Hr
Total = ________
Btu/Hr
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_____________Btu/Hr (maximum the space
can support)
___________ Btu/Hr (actual amount of
Btu/Hr used) Example: 51,200 Btu/Hr (maximum the
space can support)
70,000 Btu/Hr (actual amount
of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maxi
­mum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an
adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.
B. Vent room directly to the outdoors. See Ven
-
tilation Air From Outdoors,
page 7.
C. Install a lower Btu/Hr heater, if lower Btu/Hr
size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support,
the
space is an unconfined space. You will need no additional fresh air ventilation.
40,000
30,000
70,000
Page 7
www.desatech.com
115580-01A 7
AIR FOR COMBUSTION
AND VENTILATION
Continued
WARNING: If the area in
which the heater may be oper
­ated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, Section
5.3 or applicable local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining un­confined space. When ventilating to an adjoining unconfined space, you must provide two perma­nent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of
ventilation grills or ducts.
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri
­mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
WARNING: A qualified ser­vice person must install heater. Follow all local codes.
Figure 2 - Ventilation Air from Inside
Building
Or Remove Door into Adjoining
Room, Option
3
Ventilation Grills
Into Adjoining Room,
Option
2
Ve
ntilation
Grills
Into Adjoining
Room,
Option 1
12"
12"
Figure 3 - Ventilation Air from Outdoors
Outlet Air
Ve
ntilated
Attic
Outlet
A
ir
Inlet Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet
or outlet air into attic if attic has a thermostat­controlled power vent. Heated air entering the attic will activate the power vent.
Page 8
www.desatech.com
115580-01A
8
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing or other flammable objects are less than 42 inches from the front, top or sides of the heater
• in high traffic areas
• in windy or drafty areas
CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, to­bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.
IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air
for Combustion and Ventilation
, page 5.
CHECK GAS TYPE
Use only the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.
WARNING: This appliance is equipped for (natural or pro
­pane/LP) gas. Field conversion is not permitted.
INSTALLATION
Continued
CLEARANCES TO COMBUSTIBLES
(Vent-Free Operation Only)
WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining side and back walls.
Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 4. Measure from outermost point of stove top.
Minimum Wall and Ceiling Clearances (see Figure 4)
A. Clearances from outermost point of stove top
to any combustible side wall should not be less than 12 inches.
B. Clearances from outermost point of stove top
to any combustible back wall should not be less than 6 inches (includes corner installations).
C. Clearances from the stove top to the ceiling
should not be less than 48 inches.
12"
Minimum
12"
Minimum
48"
Minimum
Ceiling
Side Wall Side Wall
Back Wall
Side Wall Side Wall
12 "
Minimum
12 "
Minimum
6 "
Minimum
Corner
Wa
ll
Wa
ll
6 "
Minimum
6 "
Minimum
6"
Minimum
48"
Minimum
Ceiling
Floor
Back
Wall
Figure 4 - Minimum Clearance to Walls
and Ceiling (Stove May Vary Depending
on Model)
Page 9
www.desatech.com
115580-01A 9
STOVE CAVITY ASSEMBLY
1. Lift off corrugated box enclosing stove body crating.
2. Remove all screws fastening the wood frame enclosure. Spread wood frame open and lift away from plastic-bagged stove body. The bottom pieces of pallet wood will remain bolted to the stove body.
3. Remove plastic bag from stove body.
4. Remove back panel from stove (see Figure 5). Use an adjustable wrench or a 10 mm socket. Remove six (6) bolts and washers. Keep bolts and washers to reattach back panel later.
5. Remove all contents from inside stove cavity. Contents include:
(1) - Stove bottom (4) - Legs (Amity models include leg leveler bolts) (1) - Bottom door (1) - Top grate (1) - Hardware kit bag with fasteners
6. Carefully lay stove body on back to attach bottom components to stove body (see Figure 6). Rest stove on drop cloth or blanket to avoid scratching stove edges.
INSTALLATION
Continued
Figure 5 - Removing Back Panel
Bolt
Product Identification Label
Back Stove Panel
Figure 6 - Laying Down Stove On Side (Stove Style May Vary Depending on Model)
Front of Stove Unit
Pallet Wood Bolted to Stove Body Bottom
Top of Stove Unit
Front of Stove Unit
Top of Stove Unit
Drop Cloth/ Blanket
7. Remove remaining pallet wood attached to bottom of stove body (see Figure 7). Use an adjustable wrench to remove bolts.
8. Fasten each leg to stove with four (4) bolts. Use a flat screw driver to tighten bolt to leg. Thread bolt in tapped holes on stove body (see Figure 8 and Figure 9, page 10).
Figure 7 - Removing Pallet Wood From
The Bottom of The Stove
Pallet Wood
Bolt
Bottom Of Stove Unit
Front
Pallet Wood
Figure 8 - Locating Threaded Holes
for Stove Bottom, Legs and Door
Attachment (Appearance May Vary
Depending on Model)
Leg Hole
Leg Hole
Leg Hole
Leg Hole
Door Hinge Step Bolt Hole
Door Catch Bolt With Adjustable Hex Nuts Hole
Stove Bottom Holes
Front
Bottom Of Stove Unit
Page 10
www.desatech.com
115580-01A
10
INSTALLATION
Continued
9. Fasten stove bottom to stove with four (4) M6 x 1 - 25mm bolts. Use a flat washer and lock washer with each bolt. Tighten bolts into threaded holes on stove body (see Figure 10 and Figure 8 on page 9). Use an adjustable wrench or a 10mm socket.
10. Attach stove door by inserting step bolt through door hinge pivot holes and into threaded hole in stove body (see Figure 11). Use an adjustable wrench or a 12mm socket to fasten step bolt. Tighten step bolt until snug. Make sure door moves freely.
11. Install door catch bolt (M8 x 1.25-55mm with two M8 hex nuts) into threaded hole on stove body (see Figure 8, page 9). Use an adjustable wrench or a 12mm socket. The catch bolt has two hex nuts attached to it (see Figure 12). The top nut is a bolt stop and the bottom nut is for door leveling adjustment.
12. Check general catch bolt alignment with door claw. Make final adjustment and door leveling after stove is in normal standing position.
13. Carefully lift stove back up on its four at
-
tached legs.
Figure 9 - Attaching Stove Legs
Bottom Of Stove Unit
Leg
Bolt
Figure 10 - Attaching Stove Bottom
Bottom Of Stove Unit
Bolt
Washers
Stove Bottom
14. If available, install gas log heater inside stove cavity before installing the back panel (see In
-
stalling Gas Log Heater Into Stove, page 11).
15. Fasten back panel to stove with six (6) M6 x 1
- 20mm bolts and washers. Make sure product identification label is located on the outside in lower left-hand corner.
Figure 11 - Attaching Stove Door
(Appearance May Vary Depending on
Model)
Step Bolt
Door Hinge
Threaded Hole
Stove Door
Stove Bottom
Bolt Shoulder
Door Hinge
Step Bolt
Bolt Shoulder
Adjusting Nut
Bolt Stop
Catch Bolt
Door Claw
Door
Figure 12 - Catch Bolt and Door Claw
Orientation
Page 11
www.desatech.com
115580-01A 11
INSTALLING GAS LOG HEATER INTO STOVE
1. Remove log and gas log heater from carton.
Note: Do not pick up gas log heater by the burner itself. This could damage heater. Al
­ways handle the gas log heater by the heater base only.
2. Remove all protective packaging applied to log and gas log heater for shipment.
3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.
4. If not already removed, remove back panel from assembled stove body (see Figure 5, page 9). Use an adjustable wrench or a 10 mm socket. Remove six (6) bolts and washers. Keep bolts and washers to reattach back panel later.
5. Set gas log heater inside stove (see Figure
13). Make sure control knob extensions pass through bottom front opening.
6. Align outside holes on heater base with four (4) mounting holes on the stove bottom (see Figure 13).
7. Fasten heater base to stove bottom with #10-24 x .50 bolts and hex nuts provided with gas log heater (see Figure 14). Attachment hardware is factory packed inside plastic bag with installation manual and ownerʼs registration card. Push bolt through heater base mounting hole and through stove bottom. Connect hex nut to bolt on underside of stove bottom. The bolt hex head is for a 5/16" socket and the hex nuts are for a 3/8" socket. If sockets are not available, use adjustable wrenches.
INSTALLATION
Continued
Figure 13 - Placing Heater Base In Stove
Cavity (Appearance May Vary Depending
on Model)
Bottom Front Opening
Stove Bottom
Burner
Bolt
Heater Base
Figure 14 - Fastening Heater Base to
Stove Drop Bottom
Stove Bottom
Heater Base
Bolt
Hex Nut
One­Piece Log Set
"U" Shaped Cutout in Chassis
Burner
Middle Section at Bottom of Log Set
Figure 15 - Installing One-Piece Stove
Log Set
Heater Base
8. Set one-piece log on heater base as shown in Figure 15. Make sure middle section at bot
­tom of log is seated into "U" shaped cutout in center of heater base. Log will fit securely on base. IMPORTANT: Make sure log does not cover any burner ports and does not touch the stove cavity (see Figure 16).
9. Fasten back panel to stove with six (6) M6 x
1.20mm bolts and washers. Make sure product identification label is located on the outside lower left-hand corner.
10. Place freestanding stove in desired position in room. Be sure to maintain clearances to combustibles as outlined on page 8.
Burner Porting Areas (double slotted rectangular openings)
Figure 16 - Top View of One-Piece Log
Set on Gas Log Heater
Safety Pilot Location
One-Piece Log Set
Page 12
www.desatech.com
115580-01A
12
INSTALLATION
Continued
CONNECTING TO GAS SUPPLY
WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
CAUTION: Never connect propane/LP heater directly to the propane/LP supply. Pro
­pane/LP heaters require an ex­ternal regulator (not supplied). Install the external regulator between the heater and pro
­pane/LP supply.
WARNING: For natural gas units, never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
• exte rnal regu lator for propa ne/LP units (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See
Accessories, page 21.
Figure 17 - Gas Regulator Location and
Gas Line Access Into Stove Cabinet
Back Stove Panel
Front of Stove Unit
Gas Inlet Connection Access
Product Identifica­tion Label
Gas Log Heater
Back View
Side View
The gas inlet connection for the stove heater is located on the lower right-hand side of the stove when viewed from the front of the unit. The gas connection can be made either through the bottom right side or through the lower back opening as illustrated in Figure 17. Make sure gas log heater is secured to the stove cavity assembly.
For propane/LP gas, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres
­sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 18. Pointing the vent down protects it from freezing rain or sleet.
Back Stove Panel
Figure 18 - External Regulator With Vent
Pointing Down
Propane/LP Supply Tank
Vent Pointing Down
External Regulator
Page 13
www.desatech.com
115580-01A 13
CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas vol­ume to heater. If pipe is too small, undue loss of volume will occur.
Installation must include a equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 19).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
Check your building codes for any special re
­quirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
INSTALLATION
Continued
Tee Pipe Cap Joint Nipple
Figure 19 - Gas Connection
3" Minimum
Sediment Trap
Gas Regulator
Natural
From, Gas Meter (5" W.C. ** to 10.5" W.C. Pressure)
CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap*
Approved Flexible Gas Hose (if allowed by local codes)
We recommend that you install a sediment trap in supply line as shown in Figure 19. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detec­tion fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.
Propane/LP
From External Regulator (11" W.C.** to 14" W.C. Pressure)
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer.
See Accessories, page 21.
** Minimum inlet pressure for purpose of input adjustment.
Page 14
www.desatech.com
115580-01A
14
CAUTION: For propane/LP units, make sure external regula­tor has been installed between propane/LP supply and heater. See guidelines under Connect- ing to Gas Supply, page 12.
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.
2. Cap off open end of gas pipe where equipment shutoff valve was connected.
3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.
4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fit
-
tings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 20).
2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.
3. Check all joints from gas meter (natural gas) or propane/LP supply to equipment shutoff valve (see Figure 21 or 22). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.
4. Correct all leaks at once.
INSTALLATION
Continued
Figure 20- Equipment Shutoff Valve
Closed
Equipment Shutoff Valve
Open
Figure 21 - Checking Gas Joints
(Propane/LP Gas Only)
Control Valve Location
Propane/LP Supply Tank
Equipment Shutoff Valve
Figure 22 - Checking Gas Joints
(Natural Gas Only)
Control Valve Location
Gas Meter
Equipment Shutoff Valve
PRESSURE TESTING HEATER GAS CONNECTIONS
1. Open equipment shutoff valve (see Figure 20).
2. Open propane/LP supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from gas meter (natural gas) or propane/LP supply to equipment shutoff valve (see Figure 21 or 22). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 15). Check all other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appli
-
ance, page 16).
Page 15
www.desatech.com
115580-01A 15
3. Turn control knob clockwise to the OFF position.
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you donʼt smell gas, go to the next step.
5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 23).
Note: You may be running this heater for
the first time after hooking up to gas sup
­ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.
6. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 16.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.
OPERATING HEATER
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol­low these instructions exactly, a fire or explosion may result causing property damage, per
-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neigh bor ʼs phone. Follow the gas supplierʼs instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service tech
­nician or gas supplier. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be pres
­ent. Open a window to vent smell. This will only last a few hours.
1. STOP! Read the safety informat ion , above.
2. Make sure equipment shutoff valve is fully open.
Figure 23 - Control Knob and Ignitor
Button Location
Control Knob
Ignitor Button
Figure 24 - Pilot (Propane/LP Shown)
Thermocouple
Pilot Burner
Page 16
www.desatech.com
115580-01A
16
8. Turn co ntrol knob count erclockwi se
to desired heating level. The burn­ers should light. Set control knob to any heat level between HI and LO.
CAUTION: Do not try to ad­just heating levels by using the equipment shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise
to the
OFF position.
Shutting Off Burners Only (pilot stays lit)
Turn control knob clockwise
to the
PILOT position.
THERMOSTAT CONTROL
OPERATION
The thermostat control knob can be set to any comfort level between HI and LO. The ther­mostat will gradually modulate the heat output and flame height from higher to lower settings or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
Note: Selecting the HI setting with the control knob will cause the burner to remain fully on, without modulating down in most cases.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions, page 15.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 in Lighting Instructions, above.
OPERATING HEATER
Continued
INSPECTING BURNERS
Check pilot flame pattern and burner flame pat­terns often.
PILOT FLAME PATTERN
Figure 25 shows a correct pilot flame pattern. Figure 26 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 26
• turn heater off (see To Turn Off Gas to Appli
-
ance, column 1)
• see Troubleshooting
, page 18
Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.
Figure 25 - Correct Pilot Flame Pattern
Figure 26 - Incorrect Pilot Flame Pattern
Pilot Burner
Thermocouple
Pilot Burner
Propane/LP Natural Gas
Pilot Burner
Pilot Burner
Thermocouple
Propane/LP Natural Gas
Page 17
www.desatech.com
115580-01A 17
CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner and circu
­lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent clean­ing due to excessive lint from carpeting, pet hair, bedding material, etc.
BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend us
­ing compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly. Note: Removing the rear panel and top grates of your stove will make cleaning easier.
1. Shut off the unit, including the pilot. Allow
the unit to cool for at least thirty minutes.
2. Inspect burner, pilot and primary air inlet holes on
injector holder for dust and dirt (see Figure 27).
3. Blow air through the ports/slots and holes in
the burner.
4. Check the injector holder located at the end
of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle.
5. Blow air into the primary air holes on the injector holder.
6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as
­sembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 28). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Figure 27 - Injector Holder On Outlet
Burner Tube
Burner Tube
Injector Holder (May Be Brass or Aluminum Depending on Model)
Primary Air Inlet Holes (Shape of Holes May Vary by Model)
Figure 28 - Pilot Inlet Air Hole
Burner Tube
Pilot Assembly
Pilot Air Inlet Hole
Ports/Slots
Page 18
www.desatech.com
115580-01A
18
TROUBLESHOOTING
WARNING: Turn off heater and let cool before servicing. Only a
qualified service person should service and repair heater.
CAUTION: Never use a wire, needle or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Ignitor electrode not connected to ignitor cable
2. Ignitor cable pinched or wet
3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode broken
6. Ignitor electrode positioned wrong
1. Gas supply turned off or equip
-
ment shutoff valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in PILOT position
4. Air in gas lines when installed
5. ODS/pilot is clogged
6.
Gas regulator setting is not correct
7. Depleted gas supply (Propane/ LP only)
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Equipment shutoff valve not fully open
4.
Pilot flame not touching thermo­couple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following:
A) Low gas pressure B) Dirty or partially clogged
ODS/pilot
5. Thermoc o uple connect i o n loose at control valve
6. Thermocouple damaged
7. Control valve damaged
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry
3. Replace ignitor cable
4. Replace piezo ignitor
5. Replace pilot assembly
6. Replace pilot assembly
1. Turn on gas supply or open equip
-
ment shutoff valve
2. Turn control knob to PILOT position
3. Press in control knob while in PI
-
LOT position
4. Continue holding down control knob. Repeat igniting operation until air is removed
5. Clean ODS/pilot (see Cleaning and Maintenance, page 17) or replace ODS/pilot assembly
6. Replace gas control
7. Contact local propane/LP gas company
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob pressed in 30 seconds
3. Fully op en equip ment shu toff valve
4. A) Contact local natural or pro­pane/LP gas company
B) Clean ODS/pilot (see Clean
-
ing and Maintenance, page 17) or
replace ODS/pilot assembly
5. Hand tighten until snug, then tighten 1/4 turn more
6. Replace pilot assembly
7. Replace control valve
OBSERVED PROBLEM
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is released
Page 19
www.desatech.com
115580-01A 19
OBSERVED PROBLEM
Burner does not light after ODS/ pilot is lit
Delayed ignition burner
Burner backfiring during com
-
bustion
Slight smoke or odor during initial operation
Moisture/condensation noticed on windows
Heater produces a whistling noise when burner is lit
Dark residue on logs or inside of fireplace
REMEDY
1. Clean burner (see Cleaning and Maintenance, page 17)
or replace burner orifice
2. Contact local natural or pro­pane/LP gas company
1. Contact local natural or pro
-
pane/LP gas company
2. Clean burner (see Cleaning and Maintenance, page 17) or replace burner orifice
1. Clean burner (see Cleaning and Maintenance, page 17) or replace burner orifice
2. Replace damaged burner
3. Replace gas control
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Mainte
-
nance, page 17)
2. Replace gas control
3. Problem will stop after a few hours of operation
1. Refer to Air for Combustion and Ventilation requirements (page 5)
1. Turn control knob to LO position and let warm up for a minute
2. Operate burner until air is removed from line. Have gas line checked by local natural or propane/LP gas company
3. Observe minimum installation clearances (see page 7)
4. Clean burner (see Cleaning and Maintenance, page 17) or replace burner orifice
1. Properly locate logs (see
In-
stalling Gas Log Heater Into Stove, page 11)
2. Eliminate source of drafts around heater
3. Clean out air holes at burner inlet. Periodically repeat as needed
4. Remove blockage
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Burner orifice clogged
2. Inlet gas pressure is too low
1. Manifold pressure is too low
2. Burner orifice clogged
1. Burner orifice is clogged or damaged
2. Damaged burner
3. Gas regulator defective
1. Not enough air
2. Gas regulator defective
3. Residues from manufacturing processes and logs curing
1. Not enough combustion/ven
-
tilation air
1. Turning control knob to HI position when burner is cold
2. Air in gas line
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice
1. Improper log placement
2. Drafts or other air currents affecting flame pattern
3. Air holes at burner inle t blocked
4. Burner flame holes blocked
Page 20
www.desatech.com
115580-01A
20
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Fol­low the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
POSSIBLE CAUSE
1. When heated, vapors from furniture polish, wax, carpet cleaners, etc. may turn into white powder residue
1. Metal expanding while heat
­in g or cont rac tin g whil e cooling
1. Heater burning vapors from pai nt, hai r spray, glu es, cleaners, chemicals, new carpet, etc. (See IMPOR
-
TANT
statement above)
2. Gas leak. See Warning
statement at top of page
1. Not enough fre s h air is available
2. Low line pressure
3. O D S/ pi lot i s p a rt ia ll y clogged
1. Gas leak. See Warning
statement at top of page
2. Control valve defective
1. Foreig n ma t ter betwe e n control valve and burner
2. Gas leak. See Warning
statement at top of page
OBSERVED PROBLEM
White powder residue forming within burner box or on adjacent walls or furniture
Heater produces a clicking/tick
­ing noise just after burner is lit or shut off
Hea t er produc e s u nwante d odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
REMEDY
1. Turn heater off when using furniture polish, wax, carpet cleaners or similar products
1. This is common with most heat
­ers. If noise is excessive, contact qualified service person
1. Open window and ventilate room. Stop using odor caus
­ing products while heater is running
2. Locate and correct all leaks (see Checking Gas Connec
-
tions, page 13)
1. Open window and/or door for ventilation
2. Contact local natural or pro
-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning and Maintenance, page 17)
1. Locate and correct all leaks (see Checking Gas Connec
-
tions, page 13)
2. Replace control valve
1. Take apart gas tubing and remove foreign matter
2. Locate and correct all leaks (see Checking Gas Connec
-
tions, page 13)
TROUBLESHOOTING
Continued
Page 21
www.desatech.com
115580-01A 21
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, con
-
tact your local natural or propane/LP gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation or troubleshooting. If so, contact DESA Heating Productsʼ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.
You can also visit DESA Heating Productsʼ techni
-
cal service web site at www.desatech.com.
REPLACEMENT PARTS
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Heating Productsʼ Technical Service Department at 1-866-672-6040.
When calling DESA Heating Products, have ready
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they canʼt supply original replacement part(s), either contact your nearest Parts Central (see page 26) or call DESA Heating Products at 1-866-672-6040 for referral information.
When calling DESA Heating Products, have ready
• model number of your heater
• the replacement part number
ACCESSORIES
Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA Heating Products at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.
EQUIPMENT SHUTOFF VALVE GA5010
For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.
CLEANING KIT - CCK (Not Shown)
For all models. Your vent-free gas appliance re­quires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.
INFORMATION VIDEO - 108917-01
For all models. A care and maintenance video is available by calling 1-866-672-6040.
SPECIFICATIONS
SL30PT SL30NT
Btu (Variable) 16,000/30,000 16,000/30,000
Type Gas Propane/LP Only Natural Gas Oly
Ignition Piezo Piezo
Pressure Manifold 8" W.C. 3.5" W.C.
Inlet Gas Pressure (in. of water) Maximum 14" 10.5" Minimum* 11" 5"
Shipping Weight 28 lbs. 28 lbs.
* For input adjustment
Page 22
www.desatech.com
115580-01A
22
ILLUSTRATED PARTS BREAKDOWN
SL30PT (Shown) SL30NT
14
16
3
4
15
5
11
6
12
7
10
15
8
9
1
17
2
18
18
18
13
Page 23
www.desatech.com
115580-01A 23
PARTS LIST
This list contains replaceable parts used in your stove. For replacement parts see Replacement Parts on page 21 of this manual.
KEY PART NUMBER NO. SL30PT SL30NT DESCRIPTION QTY.
1 104026-01 104026-01 Stove Log 1 2 098249-01 098249-01 Nut, M5 2 3 ** ** Painted Base Assembly 1 4 104454-01 104454-01 Bracket, Regulator 1 5 098867-10 098867-14 Gas Regulator 1 6 104425-01 104425-01 Inlet Tube 1 7 104422-03 111331-06 Outlet Burner Tube 1 8 099056-19 099056-26 Burner Orifice Injector 1 9 111124-01 111124-01 Burner Retainer Spring 1 10 102980-01 102980-01 Burner 1 11 101329-22 101329-21 Control Valve 1 12 104472-01 104472-01 Bracket 1 13 099211-01 099211-01 Screw 2 14 102445-01 102445-01 Piezo Ignitor 1 15 099387-13 099387-13 Pilot Tube 1 16 098271-10 098271-10 Ignitor Cable 1 17 104286-01 104285-01 ODS Pilot 1 18 M11084-38 M11084-38 Screw, Hex Head (#8-18 x .38) 7
PARTS AVAILABLE — NOT SHOWN
100563-01 100563-01 Warning Plate 1 101054-01 101054-01 Lighting Instructions Plate 1 100565-01 100565-01 Warning Plate Fastener 1 101137-04 101137-04 Hardware Kit 1
** Not a field replaceable part.
Page 24
www.desatech.com
115580-01A
24
ILLUSTRATED PARTS BREAKDOWN
CISC CISG
7
4
6
4
5-4
5-1
5-2
3
5-3
5-4
2
1R
1C
1L
Page 25
www.desatech.com
115580-01A 25
PARTS LIST
CISC CISG
This list contains replaceable parts used in your stove. For replacement parts see Replacement Parts on page 21 of this manual.
KEY PART NO. NUMBER DESCRIPTION QTY.
1L 104171-06 Top Grate with Screen - Left (Black Only) 1 1C 104171-05 Top Grate with Screen - Center (Black Only) 1 1R 104171-07 Top Grate with Screen - Right (Black Only) 1 2 104969-01 Bottom Door (Charcoal) 1 104969-02 Bottom Door (Forest Green) 1 3 104174-03 Stove Dropped Bottom 1 4 104970-01 One Leg (Charcoal) (4 Total Per Stove) 1 104970-02 One Leg (Forest Green) (4 Total Per Stove) 1 5 104971-01 Hardware Kit 1 5-1 * Door Hinge Step Bolt With Shoulder (1 Per Unit) 1 5-2 * Door Catch Bolt M8 x 1.25 - 55mm Long With Two M8 Hex Nuts (1 Per Unit) 1 5-3 * Bottom Floor Bolts M6 x 1 - 25mm Long With Flat Washer And Lock Washer (4 Per Unit) 1 5-4 * Leg Attachment Stud, Headless, Slotted, M10 x 1.5 - 40mm Long 4 6 104178-01 Back Panel Bolts M6 x 1 - 20mm Long With Flat Washer And Lock Washer (6 Per Unit) 1 7 104968-01 Stove Back Panel (Black Only) 1
PARTS AVAILABLE — NOT SHOWN
104108-08 Touch-up Spray Paint 12 oz Can (Charcoal) 1 104108-05 Touch-up Spray Paint 12 oz Can (Forest Green) 1
* Included In Hardware Kit
Page 26
www.desatech.com
115580-01A
26
PARTS CENTRALS
These Parts Centrals are privately owned businesses. They have agreed to support our customerʼs needs by providing original replacement parts and accessories
Tool & Equipment Company
5 Manila Ave. Hamden, CT 06514-0322 1-800-397-7553 203-248-7553
Portable Heater Parts
342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-888-619-7060 www.portableheaterparts.com sales@portableheaterparts.com techservice@portableheaterparts.com
FBD
1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com
Master Parts Dist.
1251 Mound Ave NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com
Washer Equipment Co.
1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com
East Coast Energy Products
10 East Route 36 W. Long Branch, NJ 07764 732-870-8809 1-800-755-8809 www.njplaza.com/ecep
21st Century
2950 Fretz Valley Road Perkasie, PA 18944-4034 215-795-0400 800-325-4828
Laporte’s Parts & Service
2444 N. 5th Street Hartsville, SC 29550-7704 843-332-0191 Parts Department
Cans Unlimited, Inc.
P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com
Page 27
www.desatech.com
115580-01A 27
_____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
_____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
_____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
NOTES
Page 28
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
115580-01 Rev. A 10/04
NOT A UPC
115580 01
LIMITED WARRANTY
VENT-FREE GAS LOG HEATERS
AND CAST IRON STOVE CHASSIS
DESA Heating Products warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA Heating Products who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUD
­ING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING PRODUCTSʼ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCI
­DENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Loading...