WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. (I.E. Installation of this product is
permitted after the manufactured (mobile) home is sited)
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause
injury or property damage. Refer to this manual for correct
installation and operational procedures. For assistance or additional information consult a
qualified installer, service
agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate
combustion and ventilation air
must be provided. Refer to
Combustion and Ventilation
tion on page 4 of this manual.
Air for
sec-
Save this manual for future reference.
Page 2
VENT-FREE NATURAL GAS PEDESTAL STOVE
SAFETY
INFORMATION
WARNINGS
WARNING ICON G 001
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate, or service this heater. Improper use of this heater can
cause serious injury or death from
burns, fire, explosion, electrical
shock, and carbon monoxide
poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early
signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness,
or nausea. If you have these signs, the heater
may not be working properly. Get fresh airat once! Have heater serviced. Some people
are more affected by carbon monoxide than
others. These include pregnant women,
people with heart or lung disease or anemia,
those under the influence of alcohol, and
those at high altitudes.
Natural Gas: Natural gas is odorless. An
odor-making agent is added to the gas. The
odor helps you detect a gas leak. However,
the odor added to the gas can fade. Gas may
be present even though no odor exists.
Make certain you read and understand all
Warnings. Keep this manual for reference.
It is your guide to safe and proper operation
of this heater.
WARNING: Any change to
this heater or its controls can be
dangerous.
1.This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.
2.If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do
not use any phone in your building
• immediately call your gas supplier
from a neighbor’s phone. F ollow the
gas supplier’s instructions
• if you cannot reach your gas supplier,
call the fire department
3.This heater shall not be installed in a
bedroom or bathroom.
4.Never install the heater
• in a recreational vehicle
• where curtains, furniture, clothing, or
other flammable objects are less than
42 inches from the front, top or sides
of the heater
• in high traffic areas
• in windy or drafty areas
5.Do not use this heater as a wood-burning heater. Use only the logs provided
with the heater.
6.Do not add extra logs or ornaments
such as pine cones, vermiculite, or rock
wool. Using these added items can
cause sooting. Do not add lava rock
around base. Rock and debris could fall
into the control area of heater.
7.You must operate this heater with the
screen in place. Make sure screen is in
place before running heater. After servicing, always replace screen before
operating heater.
8.This log heater is designed to be smokeless. If logs ever appear to smoke, turn
off heater and call a qualified service
person.
slight smoking could occur due to log
curing and heater burning manufacturing residues.
9.To prevent the creation of soot, follow
the instructions in Cleaning and Main-tenance, page 13.
10. Do not allow fans to blow directly into
the stove. Avoid any drafts that alter
burner flame patterns. Ceiling fans can
create drafts that alter burner flame
Note:
During initial operation,
patterns. Altered burner patterns can
cause sooting.
11. Before using furniture polish, wax, carpet cleaners, or similar products, turn
heater off. If heated, the vapors from
these products may create a white powder residue within burner box or on
adjacent walls or furniture.
12. Do not use a blower insert, heat exchanger insert or other accessory not
approved for use with this heater.
13. This heater needs fresh, outside air ventilation to run properly. This heater has
an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts
down the heater if not enough fresh air
is available. See Air for Combustionand Ventilation, pages 4 through 6. If
heater keeps shutting off, see Trouble-shooting, pages 14 through 16.
14. Do not run heater
• where flammable liquids or vapors
are used or stored
• under dusty conditions
15. Do not use this stove to cook food or
burn paper or other objects.
16. Do not place clothing or other flammable material on or near the appliance.
Never place any objects in the heater
or on logs.
17. Heater becomes very hot when running.
Keep children and adults away from hot
surface to avoid burns or clothing ignition. Heater will remain hot for a time
after shutdown. Allow surface to cool
before touching.
18. Carefully supervise young children
when they are in the room with heater .
19. Do not use heater if any part has been
exposed to or under water . Immediately
call a qualified service technician to inspect the room heater and to replace any
part of the control system and any gas
control which has been under water.
20. Do not operate heater if any log is broken. Do not operate heater if a log is
chipped (dime-sized or larger).
21. Turn heater of f and let cool before ser vicing. Only a qualified service person
should service and repair heater.
22. Operating heater above elevations of
4,500 feet could cause pilot outage.
2
105683
Page 3
OWNER’S MANUAL
PRODUCT
IDENTIFICATION
Screen
Logs
Heater Controls
(Inside Door)
Stove
Cabinet
PRODUCT
FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/
pilot is a required feature for vent-free room
heaters. The ODS/pilot shuts off the heater if
there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.
Figure 1 - Vent-Free Natural Gas Stove
LOCAL CODES
Install and use heater with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel GasCode ANS Z223.1, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
This heater is designed for vent-free operation. State and local codes in some areas
prohibit the use of vent-free heaters.
UNPACKING
1.Remove top inner pack.
2.Tilt carton so that stove is upright.
3.Remove protective side packaging.
4.Slide stove out of carton.
5.Remove protective plastic wrap.
6.Remove screen by lifting and then pulling forward.
7.Remove log set by cutting plastic ties.
8.Carefully unwrap log.
9.Check for any shipping damage. If
stove or log is damaged, promptly inform dealer where you bought stove.
105683
3
Page 4
VENT-FREE NATURAL GAS PEDESTAL STOVE
AIR FOR
COMBUSTION AND
VENTILATION
WARNING: This heater shall
not be installed in a confined space
or unusually tight construction
unless provisions are provided
for adequate combustion and ventilation air. Read the following instructions to insure proper fresh
air for this and other fuel-burning
appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased
insulation, and new construction methods
help reduce heat loss in homes. Home
owners weather strip and caulk around
windows and doors to keep the cold air out
and the warm air in. During heating months,
home owners want their homes as airtight
as possible.
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, heaters, clothes dryers, and
fuel burning appliances draw air from the
house to operate. You must provide adequate fresh air for these appliances. This
will insure proper venting of vented fuelburning appliances.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National
Fuel Gas Code. NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classifications:
1.Unusually Tight Construction
2.Unconfined Space
3.Confined Space
The information on pages 4 through 6 will
help you classify your space and provide
adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for
combustion and ventilation. However, in
buildings of unusually tight construction,
you must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the
outside atmosphere have a continuous water vapor retarder with
a rating of one perm (6 x 10
per pa-sec-m2) or less with openings gasketed or sealed
b. weather stripping has been
added on openable windows and
doors
c. caulking or sealants are applied
to areas such as joints around
window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three
criteria above, you must provide additional fresh air. See
From Outdoors
If your home does not meet all of the
three criteria above, proceed to
and
, page 6
Ventilation Air
.
mining Fresh-Air Flow For Heater
Location,
page 5
.
-11
and
Deter-
kg
Confined and Unconfined Space
The National Fuel Gas Code (ANS Z223.1,
1992 Section 5.3) defines a confined space
as a space whose volume is less than 50
cubic feet per 1,000 Btu per hour (4.8 m3 per
kw) of the aggregate input rating of all
appliances installed in that space and an
unconfining space as a space whose volume
is not less than 50 cubic feet per 1,000 Btu
per hour (4.8 m3 per kw) of the aggregate
input rating of all appliances installed in that
space. Rooms communicating directly with
the space in which the appliances are installed*, through openings not furnished
with doors, are considered a part of the
unconfined space.
This heater shall not be installed in a confined space or unusually tight construction
unless provisions are provided for adequate
combustion and ventilation air.
* Adjoining rooms are communicating only
if there are doorless passageways or ventilation grills between them.
4
105683
Page 5
OWNER’S MANUAL
AIR FOR
COMBUSTION AND
VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between
the rooms.
1.Determine the volume of the space (length x width x height).
Length x Width x Height = ____________________ cu. ft. (volume of space)
Example:
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of
the space.
2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example:
3.Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free heater_________________Btu/Hr
Gas water heater*_________________Btu/Hr
Gas furnace_________________Btu/Hr
Vented gas heater_________________Btu/Hr
Gas heater logs_________________Btu/Hr
Other gas appliances* +_________________Btu/Hr
Total =_________________Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_________________ Btu/Hr (maximum the space can support)
_________________ Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support.
You must provide additional fresh air. Your options are as follows:
A.
Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining
room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.
B.
Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6.
C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.
Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)
Example:
Gas water heater30,000Btu/Hr
Vent-free heater +26,000Btu/Hr
Total =56,000Btu/Hr
51,200 Btu/Hr (maximum the space can support)
56,000 Btu/Hr (actual amount of Btu/Hr used)
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space
or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of
the methods described in the
105683
National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3
or applicable local codes.
Continued
5
Page 6
VENT-FREE NATURAL GAS PEDESTAL STOVE
AIR FOR
COMBUSTION AND
12"
VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside
Building
This fresh air would come from an adjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must provide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 2). You can also
remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel
Gas Code NFPA 54/ANS Z223.1, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
WARNING: Rework worksheet, adding the space of the
adjoining unconfined space. The
combined spaces must have
enough fresh air to supply all
appliances in both spaces.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two permanent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
or spaces open to the outdoors. These spaces
include attics and crawl spaces. Follow the
National Fuel Gas Code NFPA 54/ANS
Z223.1, Section 5.3, Air for Combustion and
Ventilation for required size of ventilation
grills or ducts.
IMPORTANT:
for inlet or outlet air into attic if attic has
a thermostat-controlled power vent.
Heated air entering the attic will activate
the power vent.
Do not provide openings
Ventilation
Grills
Into Adjoining
Room,
Option 1
Figure 2 - Ventilation Air from Inside Building
Or
Remove
Door into
Adjoining
Room,
Option
3
Outlet
Air
Ventilation Grills
Into Adjoining Room,
Option 2
12"
Ventilated
Attic
Outlet
Air
Inlet
Air
Inlet Air
Figure 3 - Ventilation Air from Outdoors
Crawl Space
To Attic
To
Crawl
Space
Ventilated
6
105683
Page 7
OWNER’S MANUAL
6"
Minimum
48"
Minimum
Ceiling
Floor
Back Wall
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your primary heating system. Do not install this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualified service person must install heater.
Follow all local codes.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the heater
• in high traffic areas
• in windy or drafty areas
IMPORTANT:
Vent-free heaters add moisture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-bustion and Ventilation, pages 4 through 6.
CHECK GAS TYPE
Use only natural gas. If your gas supply is
not natural gas, do not install heater. Call
dealer where you bought heater for proper
type heater.
CLEARANCES TO
COMBUSTIBLES
(Vent-Free Operation Only)
WARNING: Maintain the minimum clearances. If you can, provide greater clearances from
floor, ceiling, and adjoining side
and back walls.
Front View
Side WallSide Wall
12"
Minimum
Carefully follow the instructions below. This
stove is a freestanding unit designed to set
directly on the floor.
IMPORTANT:
must maintain minimum wall and ceiling
clearances during installation. The minimum clearances are shown in Figure 4.
Measure from outermost point of stove top.
Minimum Wall and Ceiling
Clearances (see Figure 4)
A. Clearances from outermost point of
stove top to any combustible side wall
should not be less than 12 inches.
B. Clearances from outermost point of
stove top to any combustible back wall
should not be less than 6 inches (Includes corner installations).
C. Clearances from the stove top to the
ceiling should not be less than 48
inches.
Ceiling
48"
Minimum
12"
Minimum
You
CAUTION: This heater creates warm air currents. These
currents move heat to wall surfaces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as tobacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.
105683
Top View
12
"
Minimum
Side WallSide Wall
Corner
Wall
Back Wall
6
"
Minimum
6
"
Minimum
"
12
Minimum
Front of
Stove Unit
"
Wall
6
Minimum
Figure 4 - Minimum Clearance to Walls and Ceiling
7
Side View
Continued
Page 8
VENT-FREE NATURAL GAS PEDESTAL STOVE
INSTALLATION
Continued
CONNECTING TO GAS
SUPPLY
WARNING: A qualified service
person must connect heater to gas
supply. Follow all local codes.
Installation Items Needed
Before installing heater, make sure you have
the items listed below.
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
* An A.G.A. design-certified manual shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See
Accessories, page 21.
Back View
Side View
Front
of
Stove
Unit
Gas Regulator
Inlet Connection
WARNING: Never connect
heater to private (non-utility) gas
wells. This gas is commonly
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged heater valves.
known as wellhead gas.
CAUTION: Use pipe joint seal-
Apply pipe joint sealant lightly to male
CAUTION: Use only new,
black iron or steel pipe. Internally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
diameter or greater to allow
proper gas volume to heater. If
pipe is too small, undue loss of
pressure will occur.
ant that is resistant to liquid petroleum (LP) gas.
Install sediment trap in supply line as shown
in Figure 6. Locate sediment trap where it is
within reach for cleaning. Locate sediment
trap where trapped matter is not likely to
freeze. A sediment trap traps moisture and
contaminants. This keeps them from going
into heater controls. If sediment trap is not
installed or is installed wrong, heater may
Installation must include a manual shutoff
not run properly.
valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from
heater (see Figure 6).
CAUTION: Avoid damage to
regulator. Hold gas regulator with
wrench when connecting it to gas
piping and/or fittings.
A.G.A. Design-Certified Manual
From Gas Meter
(5" W.C.** to 10.5"
W.C. Pressure)
Sediment
Trap
Figure 6 - Gas Connection
Tee Joint
Pipe
Nipple
Cap
Shutoff Valve With 1/8" NPT Tap*
Approved Flexible Gas Hose
(if allowed by local codes)
Gas
Regulator
of Heater
3" Minimum
* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer.
See Accessories, page 21.
**Minimum inlet pressure for purpose of input adjustment.
Figure 5 - Gas Regulator Location and
Gas Line Access Into Stove Cabinet
8
105683
Page 9
OWNER’S MANUAL
NT
OS
INSTALLATION
Continued
CHECKING GAS
CONNECTIONS
WARNING: Test all gas piping and connections for leaks
after installing or servicing. Correct all leaks at once.
WARNING: Never use an open
flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. Bubbles forming show
a leak. Correct all leaks at once.
Pressure Testing Gas Supply
Piping System
Test Pressures In Excess Of 1/2 PSIG
1. Disconnect heater and its individual
manual shutoff valve from gas supply
piping system. Pressures in excess of
1/2 psig will damage heater regulator.
2. Cap off open end of gas pipe where
manual shutoff valve was connected.
3.Pressurize supply piping system by either using compressed air or opening
main gas valve located on or near gas
meter.
4.Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles forming show a leak.
5.Correct all leaks at once.
6.Reconnect heater and manual shutoff
valve to gas supply . Check reconnected
fittings for leaks.
Test Pressures Equal To or Less Than
1/2 PSIG
1.Close manual shutoff valve (see Figure 7).
2.Pressurize supply piping system by either using compressed air or opening
main gas valve located on or near gas
meter.
3. Check all joints from gas meter to
manual shutoff valve (see Figure 8). Apply mixture of liquid soap and water to
gas joints. Bubbles forming show a leak.
4.Correct all leaks at once.
O
Open
POSI
Manual
Shutoff
Valve
Closed
PO
Figure 7- Manual Shutoff Valve
Manual Shutoff Valve
Gas Meter
Control Valve Location
Figure 8 - Checking Gas Joints
Pressure Testing Heater Gas
Connections
1.Open manual shutoff valve (see Figure 7).
2.Open main gas valve located on or near
gas meter.
3.Make sure control knob of heater is in
the OFF position.
4.Check all joints from manual shutoff
valve to control valve (see Figure 8).
Apply mixture of liquid soap and water to gas joints. Bubbles forming show
a leak.
5.Correct all leaks at once.
6. Light heater (see Operating Heater,
pages 11 and 12). Check all other internal joints for leaks.
7.Turn of f heater (see To Turn Off Gas toAppliance, page 12).
105683
Continued
9
Page 10
VENT-FREE NATURAL GAS PEDESTAL STOVE
INSTALLATION
Continued
INSTALLING LOGS
WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.
CAUTION: After installation and
periodically thereafter, check to ensure that no flame comes in contact
with any log. With the heater set to
High, check to see if flames contact
any log. If so, reposition logs according to the log installation instructions in this manual. Flames
contacting logs will create soot.
It is very important to install the logs exactly
as instructed. Do not modify logs. Only use
logs supplied with heater.
Place one-piece log set on grate to fit as
illustrated in Figure 9. Make sure log sits flat
on firebox floor (see Figure 9).
IMPORTANT:
any burner ports (see Figure 10).
One Piece
Log Set
Make sure log does not cover
INSTALLING BLOWER
ACCESSORY - GA3750
Tools required: Phillips screwdriver
NOTICE: Shut off gas heater during
the following blower installation.
1.Remove top panel of stove by removing three screws from under top lip on
each side of stove (see Figure 11).
2.Facing front of stove, carefully slide top
panel forward until it is completely removed from stove (see Figure 11).
3.Disconnect power cord wires from blower
motor (if connected) (see Figure 12).
4. Disconnect green ground wire from
blower housing (if connected) by removing screw holding wire terminal
(see Figure 12).
Figure 11 - Removing Stove Top Panel
White Powercord Wire
Black Powercord Wire
5.Install one plastic bushing provided in
blower kit into the 1 1/2" hole in the left
rear of firebox floor. Access hole
through the rectangular opening in the
rear panel (see Figure 13).
6. Remove the two blower mounting
brackets from the rear panel by removing two screws each (see Figure 14).
7.Attach the two mounting brackets to
blower housing using four screws provided in blower kit (2 for each bracket)
(see Figure 14). Tighten screws securely. Place blower assembly temporarily on top of firebox.
8. Working from the rear of the stove,
place entire power cord, including
speed control housing, in lower control
compartment.
9.Route ends of 3-wire power cord up
from the lower control compartment
through the plastic bushing, then up to
the upper cavity of stove (see Figure 15).
10. Attach the terminal ends of the white
and black power cord wires to the terminals on the blower motor (see Figure 14). Push firmly.
11. Attach the terminal end of the green
power cord wire to the front tab of the
blower housing using screw provided
(see Figure 12).
12. Using the four screws previously removed, mount blower assembly to
stove by reattaching blower brackets to
rear panel (see Figure 14). Tighten
screws securely.
Blower
Bracket
I
H
L
O
O
F
F
N
O
P
T
I
L
O
Firebox Floor
Figure 9 - Installing One-Piece Log Set
Burner Ports
One Piece Log Set
Figure 10 - Installing One-Piece Log set
(Top View)
Green
Screw
Ground Wire
Figure 12 - Removing Wires from Blower
Figure 13 - Installing Bushing
10
Blower
Firebox Top
Figure 14 - Removing Blower Brackets
from Stove and Attaching to Blower
105683
Page 11
OWNER’S MANUAL
INSTALLATION
Continued
13. Install plastic control knob onto output
shaft of speed control housing (see Figure 15). Place speed control housing
just inside control compartment door
in front of stove (see Figure 16).
14. Using two screws provided in blower
kit, mount blower speed control housing to mounting tab in left side of lower
control compartment (see Figure 16).
15. Check to make sure that the power cord is
completely clear of blower wheel and there
are no foreign objects in blower wheel.
16. Carefully replace stove top panel. Align
holes and replace six screws removed
in step 1.
17. Plug power cord into a convenient 3-prong
grounded wall receptacle near the stove.
18. Using speed control knob, turn blower
on and check for operation.
19. All remaining parts from blower kit
may be discarded.
Power
Cord
Control
Knob
Figure 15 - Routing Power Cord
Speed Control
Housing
Blower Speed
Control Housing
Figure 16 - Installing Blower Control Housing
OPERATING HEATER
FOR YOUR SAFETY
READ BEFORE
LIGHTING
WARNING: If you do not follow these instructions exactly, a
fire or explosion may result causing property damage, personal
injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly .
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.
WHA T TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Ne ver use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.
D. Do not use this appliance if any part
has been under water . Immediately call
a qualified service technician to inspect
the appliance and to replace any part
of the control system and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be present.
Open a window to vent smell. This
will only last a few hours.
1.STOP! Read the safety information,
column 2.
2.Make sure manual shutoff valve is
fully open.
3.Tur n control knob clockwise
to the OFF position.
Ignitor Button
Figure 17- Control Knob and Ignitor
Button Location
4.Wait f ive (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety information, column 2. If you don’t
smell gas, go to the next step.
5.T urn contr ol knob counterclockwise
to the PILOT position.
C-clockwise
Press in control knob for f ive (5) seconds (see Figure 17).
Note:
You may be running this
heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in
for 30 seconds or less. This will allo w
air to bleed from the gas system.
6.With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep pressing ignitor button until pilot lights.
Note:
If pilot does not stay lit, con-
tact a qualified service person or gas
supplier for repairs. Until repair s are
made, light pilot with match. T o light
pilot with match, see Manual Light-ing Procedure, page 12.
Control Knob
Clockwise
105683
Continued
11
Page 12
VENT-FREE NATURAL GAS PEDESTAL STOVE
OPERATING
HEATER
Continued
7.Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 3
through 7. This heater has a safety inter lock system. W ait one (1) minute for system to reset before lighting pilot again.
8.Turn control knob counterclockwise
C-clockwise
to desired heating level. The
burners should light. Set control knob
to any heat level between HI and LO.
Ignitor Electrode
Thermocouple
Figure 18 - Pilot
CAUTION: Do not try to adjust
heating levels by using the
manual shutoff valve.
Pilot Burner
THERMOSTAT CONTROL
OPERATION
The thermostat control knob can be set to
any comfort level between Hi and Lo. The
thermostat will gradually modulate the heat
output and flame height from higher to
lower settings, or pilot, in order to maintain
the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated,
the output of the central heating system, etc.
Note:
Selecting the Hi setting with the
control knob will cause the burners to
remain fully on, without modulating down
in most cases.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 5 under Light-
ing Instructions, page 11.
2.Depress control knob and light pilot
with match.
3.Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8 in column 1.
INSPECTING
BURNERS
Check pilot flame pattern and burner flame
patterns often.
PILOT FLAME PATTERN
Figure 19 shows a correct pilot flame pattern. Figure 20 shows an incorrect pilot
flame pattern. (
assembly may vary by model). The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to
cool. When the thermocouple cools, the heater
will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 20
• turn heater off (see To Turn Off Gas toAppliance)
• see T roubleshooting, pages 14 through 16
Thermocouple
Figure 19 - Correct Pilot Flame Pattern
Thermocouple
Note:
Appearance of pilot
Pilot Burner
Pilot Burner
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise
the OFF position.
Shutting Off Burners Only (pilot
stays lit)
Turn control knob clockwise
the PILOT position.
Clockwise
Clockwise
to
to
12
Figure 20 - Incorrect Pilot Flame Pattern
105683
Page 13
OWNER’S MANUAL
CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep control areas, burner, and circulating
air passageways of heater clean.
Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more
frequent cleaning due to excessive
lint from carpeting, pet hair, etc.
CLEANING BURNER
INJECTOR HOLDER AND
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper
amount of air to mix with the gas. This
provides a clean burning flame. Keep these
holes clear of dust, dirt, and lint. Clean these
air inlet holes prior to each heating season.
Blocked air holes will create soot. We recommend that you clean the unit every 2,500
hours of operation or every three months.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSI.
Your local computer store, hardware store, or
home center may carry compressed air in a
can. You can use a vacuum cleaner in the
blow position. If using compressed air in a
can, please follow the directions on the can.
If you don't follow directions on the can, you
could damage the pilot assembly.
1.Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.
2.Inspect burner, pilot, and primary air
inlet holes on injector holder for dust
and dirt (see Figure 21).
3. Blow air through the ports/slots and
holes in the burner.
4.Check the injector holder located at the
end of the burner tube again. Remove any
large particles of dust, dirt, lint, or pet hairs
with a soft cloth or vacuum cleaner nozzle.
5.Blow air into the primary air holes on
the injector holder.
6.In case any large clumps of dust have
now been pushed into the burner repeat
steps 3 and 4.
Clean the pilot assembly also. A yellow tip on
the pilot flame indicates dust and dirt in the pilot
assembly. There is a small pilot air inlet hole
about two inches from where the pilot flame
comes out of the pilot assembly (see Figure 22).
With the unit off, lightly blow air through the air
inlet hole. You may blow through a drinking
straw if compressed air is not available.
Burner
Tube
Primary Air Inlet
Holes (Shape of
Holes May Vary
by Model)
Figure 21 - Injector Holder On Outlet
Burner Tube
Burner
Tube
Pilot
Assembly
Pilot Air
Inlet
Hole
Figure 22 - Pilot Inlet Air Hole
Injector Holder
(May Be Brass
or Aluminum
Depending on
Model)
Ports/Slots
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air
to clean.
Exterior
• Use a soft cloth dampened with a mild
soap and water mixture. Wipe the cabinet to remove dust.
LOGS
• If you remove logs for cleaning, refer to
Installing Logs, page 10, to properly replace logs.
• Replace log(s) if broken or chipped
(dime-sized or larger).
MAIN BURNER
Periodically inspect all burner flame holes
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may become blocked by debris or rust, with no flame
present. If so, turn off heater and let cool.
Either remove blockage or replace burner.
Blocked burner flame holes will create soot.
Review your video included with your heater
for additional cleaning instructions.
REPLACEMENT
PARTS
Note:
Use only original replacement parts.
This will protect your warranty coverage
for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) call DESA International’s Technical
Service Department at 1-800-323-5190 for
referral information.
When calling DESA International, have ready
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the defec-
tive part to the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product
or Parts Central (see page 17). If they can’t
supply original replacement part(s) call
DESA International’s Parts Department at
1-800-972-7879 for referral information.
When calling DESA International, have ready
• model number of your heater
• the replacement part number
105683
13
Page 14
VENT-FREE NATURAL GAS PEDESTAL STOVE
TROUBLESHOOTING
Note:
For additional help, visit DESA
International’s Technical Service web
site at www.desatech.com.
Note:
All troubleshooting items are listed in
order of operation.
OBSERVED PROBLEM
When ignitor button is pressed, there is no
spark at ODS/pilot
When ignitor button is pressed, there is
spark at ODS/pilot but no ignition
WARNING: Turn off heater
and let cool before servicing. Only
a qualified service person should
service and repair heater.
POSSIBLE CAUSE
1. Ignitor electrode not connected to ignitor cable
2. Ignitor cable pinched or wet
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong
1. Gas supply turned off or manual shutoff
valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in
PILOT position
4. Air in gas lines when installed
5. ODS/pilot is clogged
6. Gas regulator setting is not correct
CAUTION: Never use a wire,
needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any
metal or tubing. Keep ignitor cable dry
3. T ighten nut holding piezo ignitor to base
panel of log set. Nut is located behind
base panel
4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace piezo ignitor
7. Replace piezo ignitor
1. Turn on gas supply or open manual
shutoff valve
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT
position
4. Continue holding down control knob.
Repeat igniting operation until air is removed
5. Clean ODS/pilot (see Cleaning andMaintenance, page 13) or replace ODS/
pilot assembly
6. Replace gas control
ODS/pilot lights but flame goes out when
control knob is released
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Manual shutoff valve not fully open
4. Pilot flame not touching thermocouple,
which allows thermocouple to cool,
causing pilot flame to go out. This problem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot
5. Thermocouple connection loose at control valve
6. Thermocouple damaged
7. Control valve damaged
www.desatech.com
14
1. Press in control knob fully
2. After ODS/pilot lights, keep control
knob pressed in 30 seconds
3. Fully open manual shut-off valve
4. A) Contact local natural gas company
B) Clean ODS/pilot (see Cleaning andMaintenance, page 13) or replace ODS/
pilot assembly
5. Hand tighten until snug, then tighten 1/4
turn more
6. Replace thermocouple
7. Replace control valve
105683
Page 15
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
Burner does not light after ODS/pilot is lit
OWNER’S MANUAL
POSSIBLE CAUSE
1. Burner orifice clogged
2. Inlet gas pressure is too low
3. Burner orifice diameter is too small
4. Thermopile leads disconnected or improperly connected
5. Burners will not come on in remote position
REMEDY
1. Clean burner (see Cleaning and Maintenance, page 13) or replace burner orifice
2. Contact local natural gas company
3. Replace burner orifice
4. Reconnect leads (see wiring diagram)
5. Replace battery in transmitter and receiver
Delayed ignition burner
Burner backfiring during combustion
Slight smoke or odor during initial operation
Moisture/condensation noticed on windows
Heater produces a whistling noise when
burner is lit
1. Manifold pressure is too low
2. Burner orifice clogged
1. Burner orifice is clogged or damaged
2. Damaged burner
3. Gas regulator defective
1. Not enough air
2. Gas regulator defective
3. Residues from manufacturing processes
and logs curing
1. Not enough combustion/ventilation air
1. Turning control knob to HI position w hen
burner is cold
2. Air in gas line
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice
1. Contact local natural gas company
2. Clean burner (see Cleaning and Mainte-nance, page 13) or replace burner orifice
1. Clean burner (see Cleaning and Mainte-nance, page 13) or replace burner orifice
2. Replace damaged burner
3. Replace gas control
1. Check burner for dirt and debris. If found,
clean burner (see Cleaning and Mainte-nance, page 13)
2. Replace gas control
3. Problem will stop after a few hours of
operation
1. Refer to Air for Combustion and V entila-tion requirements (page 4)
1. Turn control knob to LO position and let
warm up for a minute
2. Operate burner until air is removed from
line. Have gas line checked by local natural gas company
3. Observe minimum installation clearances
(see pages 7 through 9)
4. Clean burner (see Cleaning and Mainte-nance, page 13) or replace burner orifice
Dark residue on logs or inside of fireplace
White powder residue forming within burner
box or on adjacent walls or furniture
105683
1. Improper log placement
2. Drafts or other air currents affecting
flame pattern
3. Air holes at burner inlet blocked
4. Burner flame holes blocked
1. When heated, vapors from furniture polish, wax, carpet cleaners, etc. turn into
white powder residue
www.desatech.com
15
1. Properly locate logs (see Installing Logs,
page 10)
2. Eliminate source of drafts around heater
3. Clean out air holes at burner inlet. Periodically repeat as needed
4. Remove blockage or replace burner
1. Turn heater off when using furniture polish, wax, carpet cleaners, or similar
products
Continued
Page 16
VENT-FREE NATURAL GAS PEDESTAL STOVE
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT:
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors. These odors
will disappear over time.
Operating heater where impurities in air exist may create odors. Cleaning
OBSERVED PROBLEM
Heater produces a clicking/ticking noise
just after burner is lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF
position
POSSIBLE CAUSE
1. Metal expanding while heating or contracting while cooling
1. Heater burning vapors from paint, hair
spray, glues, cleaners, chemicals, new
carpet, etc. (See
ment above)
2. Gas leak. See W arning statement at
top of page
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See W arning statement at
top of page
2. Control valve defective
IMPORTANT
state-
REMEDY
1. This is common with most heaters. If
noise is excessive, contact qualif ied service person
1. Open window and ventilate room. Stop
using odor causing products while heater
is running
2. Locate and correct all leaks (see Check-ing Gas Connections, page 9)
1. Open window and/or door for ventilation
2. Contact local natural gas company
3. Clean ODS/pilot (see Cleaning andMaintenance, page 13)
1. Locate and correct all leaks (see Check-ing Gas Connections, page 9)
2. Replace control valve
Gas odor during combustion
1. Foreign matter between control valve
and burner
2. Gas leak. See W arning statement at
top of page
www.desatech.com
16
1. Take apart gas tubing and remove foreign matter
2. Locate and correct all leaks (see Check-ing Gas Connections, page 9)
105683
Page 17
OWNER’S MANUAL
SPECIFICATIONS
Btu (Variable)20,000/26,000
Type GasNatural Only
IgnitionPiezo
Manifold Pressure3.0" W.C.
Inlet Gas Pressure
(in. of water) *
Maximum10.5"
Minimum5"
Dimensions, Inches (H x W x D)
Stove24 x 27 1/4 x 17 1/4
Carton22 x 31 x 31 1/2
Weight, pounds
Stove66 lbs.
Shipping80 lbs.
* For purposes of input adjustment
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• natual gas supply may be low
When Gas Quality Is Bad
• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
natural gas supplier.
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG
(1-800-337-2564).
You can also visit DESA International’s
Technical Services web site at
www.desatech.com.
PARTS CENTRALS
These Parts Centrals are privately owned
businesses. They have agreed to support our
customer’s needs by providing original replacement parts and accessories.
Baltimore Electric
1348 Dixwell Avenue
Hamden, CT 06514-0322
1-800-397-7553
203-248-7553
Parts Department
Portable Heater Parts
342 N. County Rd. 400 East
Valparaiso, IN 46383-9704
All States
219-462-7441
1-800-362-6951
Parts Department
FBD
1349 Adams St.
Bowling Green, KY 42103-3413
502-846-1199
1-800-654-8534
Fax: 1-800-846-0090
Four Flags Power Products
1115 Stateline Road
Niles, MI 49120-4728
616-684-2697
1-800-268-4983
Parts Only
Master Parts Distributors
1251 Mound Ave. NW
Grand Rapids, MI 49504-3458
616-791-0505
Fax: 1-616-791-8270
Parts Department
1-800-446-1446
Washer Equipment Co.
1715 Main Street
Kansas City, MO 64108-2195
KS, MO, AR
816-842-3911
Parts Department
East Coast Energy Products
707 Broadway
W. Long Branch, NJ 07764-1542
732-870-8809
1-800-755-8809
Parts Department
Tarantin Tank Co.
P.O. Box 6129
Freehold, NJ 07728-6129
908-780-9340
1-800-922-0724
Parts Department
Heater & Heater Store
1922 N Route 9
Cape May Court, NJ 08210-1110
609-624-0678
Parts Department
Dayton Hardware
P.O. Box 275
North Dayton Station
Dayton, OH 45404-0275
All States
937-258-3721
Parts Department
1-800-762-3426
Halco Enterprises
208 Carter Drive, Unit 21
West Chester, PA 19382-4500
610-430-7717
1-800-368-0803
Parts Department
LaPorte’s Parts & Service
2444 North 5th Street
Hartsville, SC 29550-7704
803-332-0191
Parts Department
Cans Unlimited, Inc.
P.O. Box 645
Taylor, SC 29687-0013
All States
803-879-3009
1-800-845-5301
Parts Department
105683
17
Page 18
VENT-FREE NATURAL GAS PEDESTAL STOVE
ILLUSTRATED
PARTS
BREAKDOWN
S26NT
1
2
12
6
10
7
3
5
4
13
9
14
10
8
11
18
15
105683
Page 19
OWNER’S MANUAL
PARTS LIST
S26NT
This list contains replaceable parts used in your heater. When ordering parts, follow the
instructions listed under Replacement Parts on page 13 of this manual.
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions
listed under Replacement Parts on page 13 of this manual.
Purchase these heater accessories from your
local dealer or Parts Central (see page 17). If
they cannot supply these accessories call
DESA International’s Sales Department at
1-800-458-2472 for referral information.
You can also write to the address listed on
the back page of this manual.
Provides better heat distribution. Features
variable speed control knob.
105683
21
Page 22
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard
written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
VENT-FREE NATURAL GAS PEDESTAL STOVE
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date
of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all
applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this
heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty
part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original
factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed
by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or
become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel,
diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the
responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE
PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND
LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS
FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO
THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY
OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or
consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
INTERNATIONAL
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
www.desatech.com
105683 01
NOT A UPC
105683-01
Rev. A
06/99
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.