Parts Central...................................................... 39
Warranty Information ............................ Back Page
WARNING: Improper installation, adjustment, al-
teration, service or maintenance can cause in-
jury or property damage.
Refer to this manual for
correct installation and
operational procedures.
For assistance or additional information con-
sult a qualied installer,
service agency or the gas
supplier.
WARNING: This appliance
is for installation only in a
solid-fuel burning masonry
or UL127 factory-built replace or in a listed ventless rebox enclosure. It is
design-certied for these
installations in accordance
with ANSI Z21.11.2. Exception: Do not install this
appliance in a factory-built
replace that includes instructions stating it has
not been tested or should
not be used with unvented
gas logs.
WARNING: This is an
unvented gas-red heater. It uses air (oxygen)
from the room in which
it is installed. Provisions
for adequate combustion
and ventilation air must
be provided. Refer to Air
for Combustion and Ventilation section on page 5
of this manual.
This appliance may be in-
stalled in an aftermarket,*
per man ent ly loc ate d,
manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for
use with the type of gas
indicated on the rating
plate. This appliance is
not convertible for use
with other gases.
* Aftermarket: Completion of sale, not for
purpose of resale, from the manufacturer
www.desatech.com
113097-01H2
Page 3
SAFETY INFORMATION
Continued
WARNING: This product con-
tains and/or generates chemicals
known to the state of California
to cause cancer or birth defects
or other reproductive harm.
IMPORTANT: Read this owner’s
manual carefully and completely
be f o r e trying to a s s e mble,
operate or service this heater.
Improper use of this heater can
cause serious injury or death
from burns, fire, explosion,
electrical shock and carbon
monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon
monoxide poisoning resemble the u, with headaches, dizziness or nausea. If you have these signs,
the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people
are more affected by carbon monoxide than others.
These include pregnant women, people with heart
or lung disease or anemia, those under the inuence
of alcohol and those at high altitudes.
Natural and Propane/LP Gas: Natural and pro-
pane/LP gases are odorless. An odor-making agent
is added to the gas. The odor helps you detect a gas
leak. However, the odor added to the gas can fade.
Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your
guide to safe and proper operation of this heater.
WARNING: Any change to
this heater or its controls can
be dangerous.
WARNING: Do not allow fans
to blow directly into the replace.
Avoid any drafts that alter burner
ame patterns. Ceiling fans can
create drafts that alter burner
ame patterns. Altered burner
patterns can cause sooting.
WARNING: Do not use a blower insert, heat exchanger insert
or other accessory not approved
for use with this heater.
Due to high temperatures, the
appliance should be located out
of trafc and away from furniture
and draperies.
Do not place clothing or other
ammable material on or near
the appliance. Never place any
objects on the heater.
Heater base assembly becomes
very hot when running heater.
Keep children and adults away
from hot surface to avoid burns
or clothing ignition. Heater
will remain hot for a time after
shutdown. Allow surface to cool
before touching.
Carefully supervise young chil-
dren when they are in the room
with heater.
You must operate this heater
with a replace screen in place.
Make sure replace screen is
closed before running heater.
Keep the appliance area clear
and free from combustible materials, gasoline and other ammable vapors and liquids.
1. This appliance is only for use with the type
of gas indicated on the rating plate. This appliance is not convertible for use with other
gases.
2. Do not place propane/LP supply tank(s) inside
any structure. Locate propane/LP supply
tank(s) outdoors (propane/LP units only).
3. To prevent performance problems, do not
use propane/LP fuel tank of less than 100 lb.
capacity (propane/LP units only).
113097-01H3
www.desatech.com
Page 4
SAFETY INFORMATION
Continued
4. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not
use any phone in your building
• immediately call your gas supplier from
a neighb or’ s phone. Fo ll ow the gas
supplier’s instructions
• if you cannot reach your gas supplier, call
the re department
5. This heater shall not be installed in a bedroom
or bathroom unless installed as a vented appliance (Variable Manually-Controlled Models
Only) (see Installing Damper Clamp Acces-sory for Vented Operation, page 11). This
gas log set may not be installed as a vented
appliance in a bedroom or bathroom in the
Commonwealth of Massachusetts.
6. Before installing in a solid fuel burning
replace, the chimney ue and rebox must
be cleaned of soot, creosote, ashes and loose
paint by a qualied chimney cleaner. Creosote
will ignite if highly heated. A dirty chimney
ue may create and distribute soot within
the house. Inspect chimney ue for damage.
If damaged, repair ue and rebox before
operating heater.
7. Do not burn solid-fuel in a masonry or UL127
factory-built replace in which a vent-free
room heater is installed.
8.
If replace has glass doors, never operate this
heater with glass doors closed. If you operate
heater with doors closed, heat buildup inside replace will cause glass to burst. Make sure there are
no obstructions across openings of replace.
9.
This log heater is designed to be smokeless. If
logs ever appear to smoke, turn off heater and
call a qualied service person. Note: During
initial operation, slight smoking could occur
due to log curing and heater burning manufacturing residues.
10.
To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 23.
11. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
12. This heater needs fresh, outside air ventilation
to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system.
The ODS shuts down the heater if not enough
fresh air is available. See Air for Combustion and Ventilation, page 5. If heater keeps shutting
off, see Troubleshooting, page 25.
13. Do not run heater
• where ammable liquids or vapors are
used or stored
• under dusty conditions
14. Do not use this heater to cook food or burn
paper or other objects.
15. Do not use heater if any part has been exposed
to or under water. Immediately call a qualied
service technician to inspect the room heater
and to replace any part of the control system and
any gas control which has been under water.
16. Do not operate heater if any log is broken. Do
not operate heater if a log is chipped (dimesized or larger).
17. Turn heater off and let cool before servicing.
Only a qualied service person should service
and repair heater.
18. Operating heater above elevations of 4,500
feet could cause pilot outage.
19.
Provide adequate clear ances around a ir
openings.
LOCAL CODES
Install and use heater with care. Follow all local
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code, ANSI
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
National Fire Protection Association, Inc.
Note: Where listed vented decorative logs are
required, thermostat operation is not permitted.
State of Massachusetts: The installa-
tion must be made by a licensed plumber
or gas fitt er in the Common we alth of
Massachusetts.
Sel lers of unvented propane or natural
gas-red supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
1430 Broadway
New York, NY 10018
Batterymarch Park
Quincy, MA 02269
www.desatech.com
113097-01H4
Page 5
PRODUCT
IDENTIFICATION
Log Set
Burner
Piezo
Ignitor
Control Knob
Base
Grate
Figure 1 - Vent-Free Gas Log Heater
(Logs May Vary by Model, Seasonal Oak
Single Burner Model Shown)
UNPACKING
CAUTION: Do not remove
the data plates from the grate assembly. The data plates contain
important product information.
1. Remove logs and heater base assembly from
carton. Note: Do not pick up heater base assembly by burners. This could damage heater.
Always handle base assembly by grate.
2. Remove all protective packaging applied to
logs and heater for shipment.
3. Check all items for any shipping damage. If
damaged, promptly inform dealer where you
bought heater.
PRODUCT FEATURES
OpERATION
This heater is clean burning. It requires no outside
venting. There is no heat loss out a vent or up a
chimney. Heat is generated by realistic dancing,
yellow ames. This heater is designed for vent-free
operation with ue damper closed. It has been
tested and approved to ANSI Z21.11.2 standard
for unvented heaters. State and local codes in some
areas prohibit the use of vent-free heaters. This
heater may also be operated as a vented decorative
(ANSI Z21.60) product by opening the ue damper
(non-thermostat operation only).
SAFETY pILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free room
heaters. The ODS/pilot shuts off the heater if there
is not enough fresh air.
pIEzO IGNITION SYSTEM
This heater has a piezo ignitor. This system requires no matches, batteries or other sources to
light heater.
AIR FOR COMBUSTION
AND VENTILATION
WARNING: This heater shall
not be installed in a conned
space or unusually tight construction unless provisions are
provided for adequate combustion and ventilation air. Read the
following instructions to insure
proper fresh air for this and
other fuel-burning appliances
in your home.
Today’s homes are built more energy efcient
than ever. New materials, increased insulation and
new construction methods help reduce heat loss
in homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out
and the warm air in. During heating months, home
owners want their homes as airtight as possible.
While it is good to make your home energy efcient, your home needs to breathe. Fresh air must
enter your home. All fuel-burning appliances need
fresh air for proper combustion and ventilation.
113097-01H5
www.desatech.com
Page 6
AIR FOR COMBUSTION
AND VENTILATION
Continued
Exhaust fans, replaces, clothes dryers and fuel
burning appliances draw air from the house to
operate. You must provide adequate fresh air for
these appliances. This will insure proper venting
of vented fuel-burning appliances.
pROVIDING ADEQUATE
VENTILATION
The following are excerpts from National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section 5.3,
Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classications:
1. Unusually Tight Construction
2. Unconned Space
3. Conned Space
The information on pages 5 through 7 will help
you classify your space and provide adequate
ventilation.
Unusually Tight Construction
The air that leaks around doors and windows
may provide enough fresh air for combustion and
ventilation. However, in buildings of unusually
tight construction, you must provide additional
fresh air.
Unusually tight construction is dened
as construction where:
a. walls and ceilings exposed to the out-
side atmosphere have a continuous
water vapor retarder with a rating of
one perm (6x10
less with openings gasketed or sealed
and
b. weather stripping has been added on
openable windows and doors and
c. caulking or sealants are applied to
areas such as joints around window
and door frames, between sole plates
and oors, between wall-ceiling joints,
between wall panels, at penetrations
for plumbing, electrical and gas lines
and at other openings.
If your home meets all of the three criteria
above, you must provide additional fresh
air. See Ventilation Air From Outdoors,
page 7.
If your home does not meet all of the three
criteria above, proceed to Determining
Fresh-Air Flow for Heater Location.
-11
kg per pa-sec-m2) or
www.desatech.com
Conned and Unconned Space
National Fuel Gas Code, ANSI Z223.1/NFPA
54 denes a conned space as a space whose
volume is less than 50 cubic feet per 1,000 Btu
per hour (4.8 m3 per kw) of the aggregate input
rating of all appliances installed in that space and
an unconned space as a space whose volume is
not less than 50 cubic feet per 1,000 Btu per hour
(4.8 m3 per kw) of the aggregate input rating of
all appliances installed in that space. Rooms communicating directly with the space in which the
appliances are installed*, through openings not
furnished with doors, are considered a part of the
unconned space.
* Adjoining rooms are communicating only if
there are doorless passageways or ventilation grills
between them.
DETERMINING FRESH-AIR FLOW
FOR HEATER LOCATION
Determining if You Have a Conned or
Unconned Space
Use this work sheet to determine if you have a
conned or unconned space.
Space: Includes the room in which you will install
replace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length x
width x height).
Length x Width x Height =__________cu. ft.
(volume of space)
Example: Space size 20 ft. (length) x 16 ft.
(width) x 8 ft. (ceiling height) = 2,560 cu. ft.
(volume of space)
If additional ventilation to adjoining room is
supplied with grills or openings, add the volume
of these rooms to the total volume of the space.
2. Multiply the space volume by 20 to determine
the maximum Btu/Hr the space can support.
__________ (volume of space) x 20 = (Maxi-
mum Btu/Hr the space can support)
Example: 2,560 cu. ft. (volume of space) x 20 =
51,200 (maximum Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in
the space.
Vent-free replace __________ Btu/Hr
Gas water heater* __________ Btu/Hr
Gas furnace __________ Btu/Hr
Vented gas heater __________ Btu/Hr
Gas replace logs __________ Btu/Hr
Other gas appliances* + ________ Btu/Hr
Total = ________ Btu/Hr
* Do not include direct-vent gas appliances. Di-
rect-vent draws combustion air from the outdoors
and vents to the outdoors.
113097-01H6
Page 7
AIR FOR COMBUSTION
Outlet
Air
Ventilated
Attic
Outlet
A
ir
Inlet
Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
Or
Remove
Door into
Adjoining
Room,
Option
3
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilation
Grills
Into Adjoining
Room,
Option 1
12"
12"
AND VENTILATION
Continued
Example:
Gas water heater ____________ Btu/Hr
Vent-free replace + ___________ Btu/Hr
Total = ___________ Btu/Hr
4. Compare the maximum Btu/Hr the space can
support with the actual amount of Btu/Hr used.
_________
_________
Btu/Hr (maximum the space can support)
Btu/Hr (actual amount of Btu/Hr used)
Example: 51,200 Btu/Hr (maximum the space
can support)
79,000 Btu/Hr (actual amount of
Btu/Hr used)
The space in the example is a conned space because
the actual Btu/Hr used is more than the maximum
Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoin-
ing room. If the extra space provides an unconned
space, remove door to adjoining room or add
ventilation grills between rooms. See Ventilation
Air From Inside Building.
B. Vent room directly to the outdoors. See Ventila-
tion Air From Outdoors.
C. Install a lower Btu/Hr replace, if lower Btu/Hr
size makes room unconned.
If the actual Btu/Hr used is less than the maximum
Btu/Hr the space can support, the space is an unconned space. You will need no additional fresh
air ventilation.
WARNING: If the area in
which the heater may be operated is smaller than that dened
as an unconned space or if the
building is of unusually tight
construction, provide adequate
combustion and ventilation air
by one of the methods described
in the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 Section 5.3
or applicable local codes.
40,000
39,000
79,000
the two spaces (see options 1 and 2, Figure 2). You
can also remove door into adjoining room (see
option 3, Figure 2). Follow the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for
Combustion and Ventilation for required size of
ventilation grills or ducts.
Figure 2 - Ventilation Air from Inside
Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or
ducts. You must provide two permanent openings:
one within 12" of the ceiling and one within 12"
of the oor. Connect these items directly to the
outdoors or spaces open to the outdoors. These
spaces include attics and crawl spaces. Follow the
National Fuel Gas Code, ANSI Z223.1/NFPA 54,
Section 5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet
or outlet air into attic if attic has a thermostatcontrolled power vent. Heated air entering the attic
will activate the power vent.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconned space. When ventilating to an adjoining
unconned space, you must provide two permanent openings: one within 12" of the ceiling and
one within 12" of the oor on the wall connecting
113097-01H7
Figure 3 - Ventilation Air from Outdoors
www.desatech.com
Page 8
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your primary heat source. If you have a
central heating system, you may
run system’s circulating blower
while using log heater. This will
help circulate the heat from your
log heater throughout the house.
In the event of a power outage,
you can use this heater as your
primary heat source.
WARNING: Never install the
heater
• in a bedroom or bathroom
unless installed as a vented
appliance (Variable ManuallyControlled Models Only) (see
page 11)
• in a recreational vehicle
• where curtains, furniture,
clothing or other ammable
objects are less than 42" from
the front, top or sides of the
heater
• in high trafc areas
• in windy or drafty areas
WARNING: A qualied service person must install heater.
Follow all local codes.
NOTICE: State or local codes may
only allow operation of this appliance in a vented conguration.
Check your state or local codes.
WARNING: Before installing
in a solid fuel burning replace,
the chimney ue and rebox
must be cleaned of soot, creosote, ashes and loose paint by
a qualified chimney cleaner.
Creosote will ignite if highly
heated. A dirty chimney ue may
create and distribute soot within
house. Inspect chimney ue and
rebox for damage. If damaged,
repair ue and rebox before
operating heater.
WARNING: Seal any fresh
air vents or ash clean-out doors
located on oor or wall of replace. If not, drafting may cause
pilot outage or sooting. Use a
heat-resistant sealant. Do not
seal chimney ue damper.
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning uids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
IMPORTANT: Vent-free heaters add moisture to
the air. Although this is benecial, installing heater
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5.
CHECK GAS TYpE
Use the correct gas type (natural or propane/LP)
for your unit. If your gas supply is not correct, do
not install heater. Call dealer where you bought
heater for proper type heater.
WARNING: This appliance
is equipped for natural or propane/LP gas. Field conversion
is not permitted.
www.desatech.com
113097-01H8
Page 9
INSTALLATION
Continued
INSTALLATION AND CLEARANCES
(Vent-Free Operation Only)
WARNING: Maintain the
minimum clearances. If you
can, provide greater clearances
from oor, ceiling and adjoining
wall.
Carefully follow the instructions below. This will
ensure safe installation into a masonry, UL127listed manufactured replace or certied vent-free
rebox.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 4.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the
replace opening (see Figure 4).
Note: When installing your gas logs into
a man uf actur ed fireb ox , foll ow fir ebox
manufacturer’s instructions for minimum
clearances to combustible materials.
B. Clearances from the top of the replace open-
ing to the ceiling should not be less than 42".
Example
*
*Minimum 16" from Side Wall
Figure 4 - Minimum Clearance for
Combustible to Wall
NOTICE: Manual control heaters
may be used as a vented product.
If so, you must always run heater
with chimney ue damper open.
If running heater with damper
open, noncombustible material
above replace opening is not
needed. Go to Installing Damper
Clamp Accessory for Vented
Operation, page 11.
Minimum Noncombustible Material
Clearances
If Not Using Mantel
Note: If using a mantel, proceed to If Using
Mantel, page 10. If not using a mantel, follow the
information below.
You must have noncombustible material(s) above
the replace opening. Noncombustible materials
(such as slate, marble, tile, etc.) must be at least
1/2" thick. With sheet metal, you must have noncombustible material behind it. Noncombustible
material must extend at least 8" up (for all models). If noncombustible material is less than 12",
you must install the replace hood accessory (24"
and 30" models only). See Figure 5, page 10 for
minimum clearances.
IMPORTANT: If you cannot meet these minimum
clearances, you must operate heater with chimney
ue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 11.
113097-01H9
www.desatech.com
Page 10
INSTALLATION
Heat Resistant
Material
(A)
Minimum
Noncombustible
Material
Minimum
Noncombustible
Material Height
Distances to
Underside of
Mantel
Top of Fireplace
Opening
Underside
of Mantel
Shelf
Mantel Shelf
12"
8"
(A)
18"8"20"
14"
22"
17"
24"
20"
All minimum
distances
are in inches
Log Set
24"/30"
Models
18" Model
2
1
/2
"
6"
8"
10"
Continued
If Using Mantel
You must have noncombustible material(s) above
the replace opening. Noncombustible materials
(such as slate, marble, tile, etc.) must be at least
1/2" thick. With sheet metal, you must have noncombustible material behind it. Noncombustible
material must extend at least 8" up (for all models).
If noncombustible material is less than 12", you
must install the replace hood accessory (24" and
30" models only). Even if noncombustible material
is more than 12", you may need the hood accessory to deect heat away from your mantel shelf.
See Figure 5 and 6 and Figure 7 on page 11 for
minimum clearances.
Noncombustible Requirements for
Material Safe Installation
Distance (A)
12" or more Noncombust ble material
okay.
Between 8" 24", 30" or 36" Models:
and 12" Install replace hood
accessory (GA6050,
GA6052 or GA6053 see
Accessories, page 38).
18" Model: Noncombus tible material okay.
Less than 8" Noncombustible material
must be extended to at
least 8". See Between 8"
and 12", above. If you
cannot extend material,
you must operate heater
with ue damper open.
MANTEL CLEARANCES
In addition to meeting noncombustible material
clearances, you must also meet required clearances
between replace opening and mantel shelf. If
you do not meet the clearances in Figure 6 you
will need a hood.
Determining Minimum Mantel Clearance
If you meet minimum clearance between mantel
shelf and top of replace opening, a hood is not
required (see Figure 6).
Determining Minimum Mantel Clearance
When Using a Hood
If minimum clearances in Figure 6 are not met, you
must have a hood. When using a hood there are
still certain minimum mantel clearances required.
Follow minimum clearances shown in Figure 7,
page 11 when using hood.
NOTICE: Surface temperatures
of adjacent walls and mantels become hot during operation. Walls
and mantels above the rebox
may become hot to the touch.
If installed properly, these temperatures meet the requirement
of the national product standard.
Follow all minimum clearances
shown in this manual.
Figure 5 - Heat Resistant Material (Slate,
Marble, Tile, etc.) Above Fireplace
IMPORTANT: If you cannot meet these minimum
clearances, you must operate heater with chimney
ue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 11.
www.desatech.com
Figure 6 - Minimum Mantel Clearances
Without Using Hood
113097-01H10
Page 11
Minimum
Noncombustible
Material
8"
Min.
12" 15" 18"
All minimum
distances are
in inches
Log Set
20"
2
1
/2
"
6"
8"
10"
12"
Distances to
Underside of
Mantel
Hood
Top of
Fireplace
Opening
Underside
of Mantel
Shelf
Mantel Shelf
14"
Min.
Combustible
Material
Noncombustible
Material
Hearth
5"
Min.
Combustible
Material
INSTALLATION
Continued
NOTICE: If your installation does
not meet the minimum clearances shown, you must do one
of the following:
• operate the logs only with the
ue damper open
• raise the mantel to an acceptable height
• remove the mantel
All
Models
(GA6050,
GA6052 and
GA6053)
Figure 7 - Minimum Mantel Clearances
FLOOR CLEARANCES
A. If installing appliance on the oor level, you
must maintain the minimum distance of 14"
to combustibles (see Figure 8).
B. If combustible materials are less than 14" to
the replace, you must install appliance at
least 5" above the combustible ooring (see
Figure 9).
Figure 8 - Minimum Fireplace Clearances
113097-01H
When Using Hood
if Installed at Floor Level
www.desatech.com
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
INSTALLING DAMpER CLAMp
ACCESSORY FOR VENTED
OpERATION
Note: When used as a vented heater, appliance
must be installed only in a solid-fuel burning
replace with a working ue and constructed of
noncombustible material.
For Massachusetts Residents Only: Instal-
lation of this gas log set as a vented appliance in
the Commonwealth of Massachusetts requires the
damper be permanently removed or welded in the
fully open position.
If your heater is a manually-controlled model, you
may use this heater as a vented product. There
are three reasons for operating your heater in the
vented mode.
1. The replace does not meet the clearance to combustibles requirements for vent-free operation.
2. State or local codes do not permit vent-free
operation.
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you
must permanently open chimney ue damper. You
must install the damper clamp accessory (to order,
see Accessories, page 38). This will insure vented
operation (see Figure 10). The damper clamp will
keep damper open. Installation instructions are
included with clamp accessory.
Damper
Clamp
Damper
Masonry
Fireplace
Figure 10 - Attaching Damper Clamp
Damper
Damper
Clamp
Damper
Manufactured
Fireplace
11
Page 12
INSTALLATION
Continued
See chart below for minimum permanent ue
opening you must provide. Attach damper clamp
so the minimum permanent ue opening will be
maintained at all times.
data plates attached to the heater
base assembly. The data plates
contain important warranty and
safety information.
WARNING: You must secure
this heater to replace oor. If
not, heater will move when you
adjust controls. Moving heater
may cause a gas leak.
WARNING: If installing in a
sunken replace, special care
is needed. You must raise the
replace oor to allow access
to heater control panel. This
will insure adequate air ow
and guard against sooting and
controls being damaged. Raise
replace oor with noncombustible material. Make sure material
is secure.
CAUTION: Do not pick up
heater base assembly by the
burner. This could damage
heater. Only handle base assembly by grates.
IMPORTANT: Make sure the heater burners are
level. If heater is not level, heater will not work
properly. For thermostat models, avoid damage
to thermostat bulb. Avoid nicks or sharp bends
in thermostat bulb wire. Keep thermostat bulb
in mounting bracket until ready to mount base
to oor. See Optional Positioning Of Thermostat Sensing Bulb, page 28.
Installation Items Needed
• hardware package (provided with heater)
• approved exible gas hose (not provided) (if
allowed by local codes)
• sealant resistant to propane (propane/LP) gas,
not provided
• electric drill with 3/16" drill bit
• athead screwdriver
1. Apply pipe joint sealant lightly to male threads
of the tting to be threaded into gas regulator.
Connect approved exible gas hose to gas
regulator of heater (see Figure 11).
IMPORTANT: Hold gas regula to r with
wrench when connecting exible gas hose.
2. Locate masonry screws in hardware package.
3. Position heater base assembly in replace.
4. Place logs in their proper position on heater base,
see Installing Logs on page 16.
5. Center heater base and logs front-to-back and
side-to-side in replace.
6. Carefully remove logs without moving heater
base.
Flex ble Gas Hose
(if allowed by local codes)
Heater Gas
Regulator
Fitting
Figure 11 - Attaching Flexible Gas Hose
to Heater Gas Regulator
2
www.desatech.com
113097-01H1
Page 13
INSTALLATION
Continued
7. Mark screw locations through holes in mounting brackets (see Figure 12 and 13). If installing in a brick-bottom replace, mark screw
locations in mortar joint of bricks.
8. Remove heater base from replace.
9. Drill holes at marked locations using 3/16"
drill bit.
10. Attach base assembly to replace oor using
two masonry screws (in hardware package)
(see Figure 12 or 13).
CONNECTING TO GAS SUppLY
WARNING: This appliance
requires a 1/2" NPT (National
Pipe Thread) inlet connection to
the pressure regulator.
WARNING: A qualied service person must connect heater
to gas supply. Follow all local
codes.
Masonry
Screw
Mounting
Bracket
Figure 12 - Attaching Base Assembly to
Fireplace Floor - Dual Burner Model
Masonry
Screw
Mounting
Bracket
Figure 13 - Attaching Base Assembly to
Fireplace Floor - Single Burner Model
CAUTION: Never connect
heater directly to the propane/LP
supply. This heater requires an
external regulator (not supplied).
Install the external regulator between the heater and propane/LP
supply.
WARNING: Never connect
natural gas replace to private
(non-utility) gas wells. This
gas is commonly known as
wellhead gas.
Installation Items Needed
Before installing heater, make sure you have the
items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certied equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. Purchase the optional CSA
design-certied equipment shutoff valve from your
dealer. See Accessories, page 38.
113097-01H13
www.desatech.com
Page 14
INSTALLATION
Continued
For propane/LP units, the installer must supply
an external regulator. The external regulator will
reduce incoming gas pressure. You must reduce
incoming gas pressure to between 11" and 14" of
water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install
external regulator with the vent pointing down
as shown in Figure 14. Pointing the vent down
protects it from freezing rain or sleet.
CAUTION: Use only new,
black iron or steel pipe. Internally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" diameter or greater to allow
proper gas volume to heater. If
pipe is too small, undue loss of
volume will occur.
Installation must include an equipment shutoff
valve, union and plugged 1/8" NPT tap. Locate NPT
tap within reach for test gauge hook up. NPT tap
must be upstream from heater (see Figure 15).
IMPORTANT: Install equipment valve in an accessible location. The equipment shutoff valve is for
turning on or shutting off the gas to the appliance.
Check your building codes for any special requirements for locating equipment shutoff valve
to replaces.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could result
in clogged heater valves.
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
Propane/LP
Supply Tank
External
Regulator
We recommend that you install a sediment trap in
supply line as shown in Figure 15. Locate sediment
trap where it is within reach for cleaning. Install
in piping system between fuel supply and heater.
Locate sediment trap where trapped matter is not
likely to freeze. A sediment trap traps moisture and
contaminants. This keeps them from going into
heater controls. If sediment trap is not installed or
is installed wrong, heater may not run properly.
CAUTION: Avoid damage
to regulator. Hold gas regulator
with wrench when connecting it
to gas piping and/or ttings.
pROpANE/Lp
From External
Regulator (11" W.C.**
to 14" W.C. Pressure)
NATURAL
From Gas Meter
(5" W.C.** to
10.5" W.C.
Pressure)
Tee Pipe Cap
Joint Nipple
Sediment Trap
Figure 15 - Gas Connection
* Purchase the optional CSA design-certified
equipment shutoff valve from your dealer. See
Accessories, page 38.
** Minimum inlet pressure for purpose of input
adjustment.
CSA Design-
Certied Equipment
Shutoff Valve With
1/8" NPT Tap*
Gas
Regulator
3" Minimum
Approved Flexible
Gas Hose (if allowed
by local codes)
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections, internal
and external to unit, for leaks
after installing or servicing. Correct all leaks at once.
Vent
Pointing
Down
Figure 14 - External Regulator With Vent
Pointing Down
www.desatech.com
WARNING: Never use an open
ame to check for a leak. Apply a
noncorrosive leak detection uid
to all joints. Bubbles forming show
a leak. Correct all leaks at once.
113097-01H14
Page 15
INSTALLATION
Continued
CAUTION: Make sure exter-
nal regulator has been installed
between propane/LP supply and
heater. See guidelines under Con-necting to Gas Supply, page 13.
pRESSURE TESTING GAS SUppLY
pIpING SYSTEM
Test pressures In Excess Of 1/2 pSIG
(3.5 kPa)
1. Disconnect appliance with its appliance main
gas valve (control valve) and equipment
shutoff valve from gas supply piping system.
Pressures in excess of 1/2 psig will damage
heater regulator.
2. Cap off open end of gas pipe where equipment
shutoff valve was connected.
3. Pressurize supply piping by either opening
propane/LP supply tank valve for propane/LP
gas or opening main gas valve located on or
near gas meter for natural gas or using compressed air.
4. Check all joints of gas supply piping system.
Apply a noncorrosive leak detection uid to
all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff valve
to gas supply. Check reconnected ttings for
leaks.
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 16).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve
located on or near gas meter for natural gas
or using compressed air.
3. Check all joints from gas meter to equipment
shutoff valve for natural gas or propane/LP
supply to equipment shutoff valve for propane/LP (see Figures 17 and 18). Apply
noncorrosive leak detection uid to all joints.
Bubbles forming show a leak.
4. Correct all leaks at once.
pRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 16).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP
supply tank valve.
113097-01H15
www.desatech.com
3. Make sure control knob of heater is in the OFF
position.
4. Check all joints from equipment shutoff valve
to thermostat gas valve (Thermostat-Controlled Models) or to control valve (Manually-Controlled Models) (see Figures 17 and
18). Apply noncorrosive leak detection uid
to all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, page
19 [manually-controlled models] or page 21
[thermostatically-controlled models]). Check
all other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appli-ance, page 20 [manually-controlled models] or
page 22 [thermostatically-controlled models]).
Equipment
Shutoff
Valve
Figure 16 - Equipment Shutoff Valve
Propane/LP
Supply Tank
Figure 17 - Checking Gas Joints
(Propane/LP Gas Models)
Gas Meter
Figure 18 - Checking Gas Joints (Natural
Equipment
Shutoff Valve
Thermostat Gas Valve or
Control Valve Location
Equipment
Shutoff Valve
Thermostat Gas Valve or
Control Valve Location
Gas Models)
Open
Closed
Page 16
INSTALLATION
Continued
INSTALLING LOGS
Front
Log (#1)
CAUTION: After installa-
tion and periodically thereafter,
check to ensure that no ame
comes in contact with any log.
With the heater set to HI, check
to see if ames contact any log. If
so, reposition logs according to
the log installation instructions
in this manual. Flames contacting logs will create soot.
WARNING: Failure to position the parts in accordance
with these diagrams or failure
to use only parts specically
approved with this heater may
result in property damage or
personal injury.
Dual Burner Biltmore Split Oak Models
CCL3018PTA/NTA, CCL3924PTA/NTA,
CCL3930PTB/NTB
Each log is marked with a number. These numbers
will help you identify the log when installing. It
is very important to install these logs exactly as
instructed. Do not modify logs. Only use logs
supplied with heater.
1. Place the front log (#1) on the grate ngers.
Make sure the front log rests rmly between
the grate ngers and the grate base (see Figure
19).
2. Place the base of the middle log (#2) in the
U-shaped slots of the grate base. The cutout
on the right of the middle log should t over
the burner (see Figure 20). Make sure the front
of the middle log is resting on the tabs of the
grate base.
3. Locate pins on the bottom of back log (#3).
Slide these pins into the holes in the grate base
behind the burner (see Figure 21).
4. Locate holes on the bottom of crossover
log (#4). Slide front hole onto the left pin
(C CL3 924 PTA /NTA or CCL393 0PT B/
NTB) or middle pin (CCL3018PA/NA or
CCL3018PTA/NTA) on the middle log (#2)
and the pin on the back log (#3). See Figure
22, page 17, for placement.
Grate
Fingers
Grate
Base
Figure 19 - Installing Front Log #1
(CCL3930PTB/NTB Shown)
Middle
Log (#2)
Tab
Figure 20 - Installing Middle Log #2
(CCL3930PTB/NTB Shown)
Figure 21 - Installing Rear Log #3
(CCL3930PTB/NTB Shown)
U-Shaped Slot
Pins
Hole in
Grate Base
Burner
Burner
Rear
Log (#3)
www.desatech.com
113097-01H16
Page 17
INSTALLATION
7
6
Continued
5. For CCL3924PTA/NTA and CCL3930PTB/NTB
Only: Locate pin and hole on the bottom of
crossover log (#5). Slide the pin into the hole
located in crossover log (#4). Slide the hole
onto the pin on front log (#1). See Figure 23.
For CCL3018PA/NA and CCL3018PTA/NTA
Only: Locate holes on the bottom of crossover log
(#5). Slide the holes over the left pins on middle
log (#2) and front log (#1). See Figure 24.
6. Locate holes on the bottom of crossover log
(#6). Slide these holes onto the right pins
located in middle log (#2) and front log
(#1). See Figure 25 for CCL3924PTA/NTA
or CCL3930PTB/NTB. See Figure 24 for
CCL3018PA/NA or CCL3018PTA/NTA.
7. For CCL3930PTB/NTB only: Locate holes
on the bottom of crossover log (#7). Slide
onto the pins located in crossover log (#6)
and middle log (#2). See Figure 26.
8. Add lava rock around base of heater if desired. Do not place any lava rock on logs or
burner.
Middle
Log (#2)
Pins
Crossover
Log (#4)
Back Log
(#3)
Crossover
Log (#5)
Middle
Log (#2)
Figure 24 - Installing Crossover Log
#5 and Log #6 (CCL3018PA/NA and
Log (#1)
Crossover
Log (#4)
Front
Log (#1)
CCL3018PTA/NTA Only)
Crossover
Log (#6)
Crossover
Log (#6)
Pins
Middle
Log (#2)Front
Figure 25 - Installing Crossover Log #6
(CCL3930PTB/NTB Shown)
Holes
Figure 22 - Installing Crossover Log #4
(CCL3930PTB/NTB Shown)
Crossover
Log (#5)
Crossover
Log (#4)
Front Log (#1)
113097-01H17
Figure 23 - Installing Crossover Log #5
(CCL3930PTB/NTB Shown)
www.desatech.com
Pins
Figure 26 - Installing Crossover Log #7
(Model CCL3930PTB/NTB Only)
Crossover
Log (#7)
Middle
Log (#2)
Crossover
Log (#6)
Page 18
INSTALLATION
Continued
Single Burner Seasonal Oak Models
CRL2718PA/NA, CRL3124PA/NA
Front Log
WARNING: Failure to position the parts in accordance
with these diagrams or failure
to use only parts specically
approved with this heater may
result in property damage or
personal injury.
The Seasonal Oak Log Set is a reversible log set.
This means that the two bottom logs may be turned
to face either direction. The top logs, however,
must remain in the same position. Do not modify
logs. Only use logs supplied with heater.
1. Place the back log onto the back of the base assembly. Make sure log sits forward against the
two posts in front of log (see Figure 27). This
log may be turned to face either direction.
2. Place front log onto grate on front of base assembly. The log will t down between grate
ngers and posts on front of base assembly
(see Figure 28). This log may be turned to
face either direction.
3. Place the left and right crossover logs on top
of the back log and front log. Make sure pins
on front and back are inserted into holes on
crossover logs (see Figure 29). Crossover logs
must be placed as shown in Figure 29 or the
holes will not seat onto the pins.
4. Add lava rock around base of heater if desired.
Do not put lava rock on logs or burner.
Back Log
Base
Assembly
Post
Post
Grate
Fingers
Base
Assembly
Figure 28 - Installing Front Log
Left Crossover Log
Figure 29 - Installing Left and Right
Crossover Logs
Post
Right
Crossover Log
Post
Figure 27 - Installing Back Log
www.desatech.com
113097-01H18
Page 19
OPERATING HEATER
MANUALLY-CONTROLLED
MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a re or explosion may result
causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the oor because some gas is heavier than
air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supp lier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the re department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, don’t
try to repair it, call a qualied service technician or gas supplier. Force or attempted
repair may result in a re or explosion.
D. Do not use this appliance if any part has
bee n under water . Immediat ely call a
qualied service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
LIGHTING
INSTRUCTIONS
WARNING
• If replace has glass doors,
never operate this heater with
glass doors closed. If you op-
erate heater with doors closed,
heat buildup inside replace
will cause glass to burst. Make
sure there are no obstructions
across openings of replace.
• You must operate this heater
with a fireplace screen in
place. Make sure fireplace
screen is closed before running heater.
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange ame will also be present. Open damper or window to
vent smell. This will only last a
few hours.
Note: Home owners generally prefer to operate their heater with the chimney damper
closed. This will put all the heat into the room.
However, there may be times you will desire
the full ames of the HI heat setting but will
nd the heat output excessive. You can open
the chimney damper (if you have one) fully or
partially to release some of the heat.
WARNING: Damper handle
will be hot if heater has been
running.
1. STOP! Read the safety information in
column 1.
2. Make sure equipment shutoff valve is fully
open.
3. Press in and turn control knob clockwise
to the OFF position.
4. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the oor.
If you smell gas, STOP! Follow “B” in the
safety information, column 1. If you don’t
smell gas, go to the next step.
113097-01H19
www.desatech.com
Page 20
OPERATING HEATER
Continued
5. Slightly depress and turn control knob
counterclockwise to the PILOT
position. Press in control knob for ve (5)
seconds (see Figure 30).
Note: You may be running this heater for
the rst time after hooking up to gas supply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
6. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualied service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
Note: If pilot goes out, repeat steps 3
through 7. If control knob does not pop out
when released, contact a qualied service
person or gas supplier for repairs.
8. Slightly depress and turn control knob
counterclockwise to desired heat-
ing level. The burner(s) should light. Set
control knob to any heat level between HI
and LO.
9. To leave pilot lit and shut off burners only,
turn control knob clockwise to the
HI position then press in and turn clockwise
to PILOT position.
WARNING: Do not operate
heater between PILOT and HI
positions.
Ignitor
Electrode
Thermocouple
Figure 31 - Pilot
Pilot Burner
VARIABLE CONTROL
OpERATION
The variable control valve can be set to any
heat setting and ame height desired, by simply
turning the control knob until that setting is
attained. Even the lowest setting provides realistic, dancing yellow ames. Selecting higher
settings produces greater heat output. This
results in increased heating comfort.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
TO TURN OFF GAS
TO AppLIANCE
1. Press in and turn control knob clockwise
2. Turn control knob clockwise to the
3. Press in control knob and turn clockwise
4. Close equipment shutoff valve (see Figure
1. Follow steps 1 through 5 under Lighting
2. Depress control knob and light pilot with
3. Keep control knob pressed in for 30 seconds
to the HI position.
pilot position.
to the OFF position.
16, page 15).
MANUAL LIGHTING
pROCEDURE
Instructions, pages 19 and 20.
match.
after lighting pilot. After 30 seconds, release
control knob. Now follow step 8, under
Lighting Instructions, column 1.
Ignitor Button
Figure 30 - Control Knob and Ignitor
Control Knob
Button Location
www.desatech.com
113097-01H20
Page 21
OPERATING HEATER
Continued
LIGHTING
INSTRUCTIONS
THERMOSTAT-CONTROLLED
MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly,
a re or explosion may result
causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the oor because some gas is heavier than
air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediat ely call your gas s upplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the re department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, don’t
try to repair it, call a qualied service technician or gas supplier. Force or attempted
repair may result in a re or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualied service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
WARNING
• If replace has glass doors,
never operate this heater with
glass doors closed. If you op-
erate heater with doors closed,
heat buildup inside replace
will cause glass to burst. Make
sure there are no obstructions
across openings of replace.
• You must operate this heater
with a fireplace screen in
place. Make sure fireplace
screen is closed before running heater.
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange ame will also be present. Open damper or window to
vent smell. This will only last a
few hours.
Note: Home owners generally prefer to operate their heater with the chimney damper
closed. This will put all the heat into the room.
However, there may be times you will desire
the full ames of the HI heat setting but will
nd the heat output excessive. You can open
the chimney damper (if you have one) fully or
partially to release some of the heat.
WARNING: Damper handle
will be hot if heater has been
running.
1.
STOP ! Read th e safet y inf orm ation ,
column 1.
2. Make sure equipment shutoff valve is fully
open.
3. Turn control knob clockwise to the
OFF position.
4. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the oor.
If you smell gas, STOP! Follow “B” in the
safety information, column 1. If you don’t
smell gas, go to the next step.
113097-01H21
www.desatech.com
Page 22
OPERATING HEATER
O
H
O F
Pl
Continued
5. Turn control knob counterclockwise
to the PILOT position. Press in control
knob for ve (5) seconds (see Figure 32).
Note: You may be running this heater for
the rst time after hooking up to gas supply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
6. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualied service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety interlock
system. Wait one (1) minute for system to
reset before lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The burners should
light. Set control knob to any heat level
between HI and LO.
9. Turn control knob clockwise to the
PILOT position to shut off burner leaving
pilot lit.
Ignitor
Electrode
Pilot Burner
Thermocouple
Figure 33 - Pilot
TO TURN OFF GAS
TO AppLIANCE
1. Turn control knob clockwise to the
OFF position.
2. Close equipment shutoff valve (see Figure
16, page 15).
THERMOSTAT
CONTROL OpERATION
The thermostat control knob can be set to any
comfort level between HI and LO. The thermostat will gradually modulate the heat output
and ame height from higher to lower settings
or pilot, in order to maintain the comfort level
you select. The ideal comfort setting will vary
by household depending upon the amount of
space to be heated, the output of the central
heating system, etc.
Note: Selecting the HI setting with the control
knob will cause the burners to remain fully on,
without modulating down in most cases.
MANUAL LIGHTING
pROCEDURE
1. Follow steps 1 through 5 under Lighting
Instructions, page 21.
2. Depress control knob and light pilot with
match.
3. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow step 8, under
Lighting Instructions, column 1.
Ignitor Button
Control Knob
Figure 32 - Control Knob and Ignitor
Button Location
www.desatech.com
113097-01H22
Page 23
INSPECTING BURNERS
Check pilot ame pattern and burner ame patterns often.
pILOT FLAME pATTERN
Figure 34 shows a correct pilot ame pattern. Figure
35 shows an incorrect pilot ame pattern. The incorrect pilot ame is not touching the thermocouple.
This will cause the thermocouple to cool. When the
thermocouple cools, the heater will shut down.
If pilot ame pattern is incorrect, as shown in
Figure 35
• turn heater off (see To Turn Off Gas to Appli-ance, page 20 [manually-controlled models] or
page 22 [thermostat-controlled models])
• see Troubleshooting, page 25
Note: The pilot ame on natural gas units will
have a slight curve, but ame should be blue and
have no yellow or orange color.
Pilot Burner
CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner and circulating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a
qualied service person. Heater
may need more frequent cleaning due to excessive lint from
carpeting, bedding material, pet
hair, etc.
WARNING: Failure to keep
the primary air opening(s) of
the burner(s) clean may result in
sooting and property damage.
Thermocouple
Figure 34 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
Figure 35 - Incorrect Pilot Flame Pattern
BURNER pRIMARY AIR HOLES
Air is drawn into the burner through the holes in the
tting at the entrance to the burner. These holes may
become blocked with dust, lint or pet hair. Periodically inspect these holes for any blockage and clean
as necessary. Blocked air holes will create soot.
MAIN BURNER
Periodically inspect all burner ame holes with the
heater running. All slotted burner ame holes should
be open with yellow ame present. All round burner
ame holes should be open with a small blue ame
present. Some burner ame holes may become
blocked by debris or rust, with no ame present. If
so, turn off heater and let cool. Remove blockage.
Blocked burner ame holes will create soot.
113097-01H23
www.desatech.com
BURNER INjECTOR HOLDER AND
pILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount
of air to mix with the gas. This provides a clean
burning ame. Keep these holes clear of dust, dirt,
lint and pet hair. Clean these air inlet holes prior to
each heating season. Blocked air holes will create
soot. We recommend that you clean the unit every
three months during operation and have heater
inspected yearly by a qualied service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust and
dirt. To clean these parts we recommend using
compressed air no greater than 30 PSI. Your local
computer store, hardware store or home center
may carry compressed air in a can. You can use a
vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on
the can. If you don’t follow directions on the can,
you could damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow
the unit to cool for at least thirty minutes.
Page 24
CLEANING AND
MAINTENANCE
Continued
2. Inspect burner, pilot and primary air inlet holes
on injector holder for dust and dirt (see Figure
36).
3. Blow air through the ports/slots and holes in
the burner.
4. Check the injector holder located at the end
of the burner tube again. Remove any large
particles of dust, dirt, lint or pet hair with a
soft cloth or vacuum cleaner nozzle.
5. Blow air into the primary air holes on the
injector holder.
6. In case any large clumps of dust have now been
pushed into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the
pilot ame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about
2" from where the pilot ame comes out of the
pilot assembly (see Figure 37). With the unit off,
lightly blow air through the air inlet hole. You may
blow through a drinking straw if compressed air
is not available.
Burner Tube
Injector Holder
Primary Air
Inlet Holes
Figure 36 - Injector Holder On Outlet
Burner Tube
Ports/Slots
Burner Tube
LOGS
• If you remove logs for cleaning, refer to Installing Logs, page 16, to properly replace logs.
• Replace log(s) if broken or chipped (dime-sized
or larger).
MAIN BURNER
Periodically inspect all burner ame holes with
the heater running. All slotted burner ame holes
should be open with yellow ame present. All
round burner ame holes should be open with a
small blue ame present. Some burner ame holes
may become blocked by debris or rust, with no
ame present. If so, turn off heater and let cool.
Remove blockage. Blocked burner ame holes
will create soot.
SERVICE HINTS
When Gas pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specied heat
• for propane/LP units, propane/LP gas supply
may be low
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural gas
supplier.
TECHNICAL SERVICE
You may have further questions about installation,
operation or troubleshooting. If so, contact DESA
Heating Products’ Technical Service Department
at 1-866-672-6040. When calling please have your
model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ technical service web site at www.desatech.com.
Pilot Assembly
Figure 37 - Pilot Inlet Air Hole
Pilot Air
Inlet Hole
www.desatech.com
113097-01H24
Page 25
TROUBLESHOOTING
WARNING: Turn off heater and let cool before servicing. Only a
qualied service person should service and repair heater.
CAUTION: Never use a wire, needle or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
OBSERVED pROBLEM
When ignitor button is pressed,
there is no spark at ODS/pilot
When ignitor button is pressed,
there is spark at ODS/pilot but
no ignition
ODS /pilot ligh ts but fl ame
goes out when control knob is
released
pOSSIBLE CAUSE
1. Ignit or ele ct rode not con nected to ignitor cable
2. Ignitor cable pinched or wet
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong
1. Gas supply turned off or equipment shutoff valve closed
2. Control knob not in PILOT
position
3. Control knob not pressed in
while in PILOT position
4. Air in gas li nes whe n in-
stalled
5. Depleted gas supply (propane/
LP only)
6. ODS/pilot is clogged
7.
Gas regulator setting is not
correct
1.
Control knob not fully pressed in
2. Control knob not pressed in
long enough
3. Equipment shutoff valve not
fully open
4. Pilot ame not touching thermocouple, which allows thermoc ouple to cool, causing
pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
5. The rmoco upl e conne ction
loose at control valve
6. Thermocouple damaged
7. Control valve damaged
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched
by any metal or tubing. Keep
ignitor cable dry
3. Tighten nut holding piezo ignitor
to base panel of log set. Nut is
located behind base panel
4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace pilot assembly
7. Replace pilot assembly
1. Turn on gas supply or open
equipment shutoff valve
2. Turn control knob to PILOT
position
3. Press in control knob while in
PILOT position
4. Continue holding down control knob. Repeat igniting operation until air is removed
5. Contact local propane/LP gas
company
6. Clean ODS/pilot (see Cleaning
and Maintenance, page 23) or
replace ODS/pilot assembly
7. Replace gas regulator
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob pressed in 30 seconds
3. Fully open equipment shutoff
valve
4. A) Contact local propane/LP
or natural gas company
B) Clean ODS / pilo t (s e e
Cleaning and Maintenance,
page 23) or replace ODS/pilot
assembly
5. Hand tighten until snug, then
tighten 1/4 turn more
6. Replace pilot assembly
7. Replace control valve
113097-01H25
www.desatech.com
Page 26
OBSERVED pROBLEM
Burner does light after ODS/
pilot is lit
TROUBLESHOOTING
Continued
pOSSIBLE CAUSE
1. Burner orice clogged
2. Inlet gas pressure is too low
REMEDY
1. Clean burner (see Cleaning
and Maintenance, page 23)
or replace burner orice
2. Contact local propane/LP or
natural gas company
Delayed ignition of burner
Bu r n e r b a c k f irin g dur i n g
combustion
Slight smoke or odor during
initial operation
Moisture/condensation noticed
on windows
Heater produces a whistling
noise when burner is lit
1. Manifold pressure is too low
2. Burner orice clogged
1. Burner orice is clogged or
damaged
2. Damaged burner
3. Gas regulator defective
1. Not enough air
2. Gas regulator defective
3. Residues from manufacturing
processes and logs curing
1. Not enough combustion/ven-
tilation air
1. Turning control knob to HI
or position 5 when burner is
cold
2. Air in gas line
3. Air passageways on heater
blocked
4. Dirty or par tiall y clog ge d
burner orice
1. Contact local propane/LP or
natural gas company
2. Clean burner (see Cleaning and Maintenance, page 23)
or replace burner orice
1. Clean burner (see Cleaning and Maintenance, page 23)
or replace burner orice
2. Replace damaged burner
3. Replace gas regulator
1. Check burner for dirt and debris. If found, clean burner (see
Cleaning and Maintenance,
page 23)
2. Replace gas regulator
3. Problem will stop after a few
hours of operation
1. Refer to Air for Combustion and Ventilation requirements
(page 5)
1.
Turn c on tr ol knob to LO or
position 1 and let warm up for a
minute
2. Operate burner until air i s
removed from line. Have gas
line checked by local propane/
LP or natural gas company
3. Observe minimum installation clearances (see page 9)
4. Clean burner (see Cleaning and Maintenance, page 23)
or replace burner orice
White powder residue forming
within burner box or on adjacent
walls or furniture
Heater produces a clicking/ticking noise just after burner is lit
or shut off
1. When heated, vapors from
furniture polish, wax, carpet
cleaners, etc. may turn into
white powder residue
1. Metal expanding while heating
or contracting while cooling
www.desatech.com
1. Turn heater off when using
furniture polish, wax, carpet
cleaners or similar products
1. This is common with most heaters. If noise is excessive, contact
qualied service person
113097-01H26
Page 27
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint,
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These
fumes may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED pROBLEM
Heat er pr odu ce s u nwant ed
odors
Heater s h u t s o f f i n u se
(ODS operates) temperature
drops to a lower than ideal level
before log set comes back on
Gas odor even when control
knob is in OFF position
Gas odor during combustion
Logs set cycles to pilot, but
room
pOSSIBLE CAUSE
1. Heater burning vapors from
paint, hair spray, glues, cleaners, chemicals, new carpet,
etc. (See IMPORTANT state-
ment above)
2. Gas le ak. Se e War n i ng
statement above
1. Not enough fresh air is available
2. Low line pressure
3. O D S/ p il ot i s p a rt ia ll y
clogged
1. Gas le ak. Se e War n i ng
statement above
2. Control valve defective
1. Foreign matter between control valve and burner
2. Gas le ak. Se e War n i ng
statement above
1. Thermostat sensing bulb needs
to be repositioned
REMEDY
1. Open window and ventilate
room. Stop using odor causing products while heater is
running
2. Locate and correct all leaks
(see Checking Gas Connec-tions, page 14)
1. Open window and/or door for
ventilation
2. Contact local propane/LP or
natural gas company
3. Clean ODS/pilot (see Cleaning and Maintenance, page 23)
1. Locate and correct all leaks
(see Checking Gas Connec-tions, page 14)
2. Replace control valve
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connec-tions, page 14)
1. Reposition thermostat sensing
bulb (see Optional Positioning
of Thermostat Sensing Bulb,
beginning on page 28
113097-01H27
www.desatech.com
Page 28
OPTIONAL POSITIONING
OF THERMOSTAT
SENSING BULB
FOR MASONRY AND FACTORYBUILT METAL FIREpLACE
If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level
before the log set comes back on, you may want
to reposition the thermostat sensing bulb.
The thermostat sensing bulb is located near the
gas valve assembly on the mounting bracket.
This location allows the thermostat to keep the
room temperature at an ideal comfort level for
most replace applications. For positioning the
thermostat sensing bulb elsewhere, an adhesivebacked mounting clip is available.
Tools needed: 1/4" hex driver or socket
1. Remove logs. Locate the gas valve assembly
and thermostat sensing bulb (see Figure 38).
2. With 1/4" hex driver or socket, loosen the thermostat screw. Carefully slide the thermostat
sensing bulb out of the retaining clamp (see
Figure 40).
Note: Do not remove the screw. Make sure
you tighten the screw after removing the
thermostat sensing bulb.
IMPORTANT: Do not force or bend the
thermostat sensing bulb or capillary.
3. The thermostat sensing bulb may be located to
the lower right front side of replace. Determine
location of sensing bulb, but do not mount sensing bulb until step 4. If you have a masonry replace, see Figure 41 for location. If you have
a factory-built metal replace, see Figure 42
for location. If your replace has glass doors,
position sensing bulb directly behind door gap
on right bottom side (see Figure 43).
Figure 39 - Adhesive-backed Mounting Clip
Capillary
Retaining
Clamp
Figure 40 - Removing Thermostat
Sensing Bulb
Thermostat
Sensing Bulb
Adhesive-backed
Mounting Clip
Figure 41- Locating Thermostat Sensing
Bulb on Masonry Fireplace
Thermostat
Screw
Thermostat
Sensing
Bu b
Thermostat
Sensing Bulb
Adhesivebacked
Mounting Clip
Gas Valve
Assembly
Mounting
Bracket
Figure 38 - Location of Gas Valve
Assembly and Thermostat Sensing Bulb
8
Thermostat
Sensing
Bu b
www.desatech.com
Figure 42 - Locating Thermostat Sensing
Bulb on Factory-built Metal Fireplace
Thermostat
Sensing Bu b
Adhesive-backed
Mounting Clip
Glass Doors
Figure 43 - Installing Thermostat Sensing
Bulb Behind Glass Doors
113097-01H2
Page 29
OPTIONAL POSITIONING
OF THERMOSTAT
SENSING BULB
Continued
4. The mounting clip must be a minimum of 3"
from bottom of replace to prevent crimping
of capillary. Once you have decided on a
location, clean the area thoroughly. Remove
the paper backing from the adhesive on back
of mounting clip. Press the clip into the new
location so that the thermostat sensing bulb
will be positioned vertically with the capillary at the bottom (see Figure 44). Slide the
thermostat sensing bulb into the clip.
Inlet Gas Pressure (in. of water)
Maximum 14" 10.5" 14" 10.5"
Minimum* 11" 5" 11" 5"
Shipping Weight 49 lbs. 49 lbs. 53 lbs. 53 lbs.
* For the purpose of input adjustment
Capillary
113097-01H29
www.desatech.com
Page 30
ILLUSTRATED PARTS BREAKDOWN
24
21
11
12
13
4
5
3
2
21
8
21
7
10
9
16
15
17
19
22
18
14
19
23
20
18
6
1
VARIABLE MANUALLY-CONTROLLED BILTMORE SpLIT OAK MODELS
CCL3018PA, CCL3018NA, CCL3924PA AND CCL3924NA
www.desatech.com
113097-01H30
Page 31
PARTS LIST
VARIABLE MANUALLY-CONTROLLED BILTMORE SpLIT OAK MODELS
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions
listed under Replacement Parts on page 38 of this manual.
KEY
NO.
CCL3018PA CCL3018NA CCL3924PA CCL3924NA
pART NUMBERDESCRIpTIONQTY.
1111342-03 111342-03 111342-02 111342-02 Back Log (#1)1
2111341-03 111341-03 111341-02 111341-02 Middle Log (#2)1
3111340-03 111340-03 111340-02 111340-02 Front Log (#3)1
4111343-03 111343-03 111343-02 111343-02 Left Back Crossover Log (#4)1
5111344-02 111344-02 111344-01 111344-01 Left Top Crossover Log (#5)1
6111345-02 111345-02 111345-02 111345-02
THERMOSTATICALLY-CONTROLLED BILTMORE SpLIT OAK MODELS
CCL3018PTA AND CCL3018NTA
www.desatech.com
113097-01H32
Page 33
PARTS LIST
THERMOSTATICALLY-CONTROLLED BILTMORE SpLIT OAK MODELS
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions
listed under Replacement Parts on page 38 of this manual
KEY
NO.
pART NUMBER
DESCRIpTIONQTY.CCL3018PTA CCL3018NTA
1111340-03 111340-03 Front Log (#1)1
2111341-03 111341-03 Middle Log (#2)1
3111342-03 111342-03 Back Log (#3)1
4111343-03 111343-03 Left Back Crossover Log (#4)1
5111344-02 111344-02 Left Top Crossover Log (#5)1
6111345-02 11345-02Right Bottom Crossover Log (#6)1
7****Painted Base Assembly1
8102844-02 102844-02 Lower Bracket1
9099211-01 099211-01 Hex Screw, 10-16 x 2.502
10098867-10 098867-14 Gas Regulator1
11102810-03 102810-03 Inlet Tube1
12102983-06 111331-08 Outlet Burner Tube1
13099056-19 099056-26 Burner Orice Injector1
14111124-01111124-01Burner Retainer Spring1
15102980-01 102980-01 Burner1
16101329-22 101329-21 Thermostat Gas Valve Assembly 1
17102979-02 102979-02 Thermostat Bracket1
18098544-01 098544-01 Thermostat Clip 1
19102445-01 102445-01 Piezo Ignitor1
20099387-09 099387-09 Pilot Tube1
21098271-10 098271-10 Ignitor Cable1
22104286-01 104285-01 ODS Pilot1
23M11084-38 M11084-38 Hex Screw, #8-18 x .38 15
24098249-01 098249-01 Nut, M52
THERMOSTATICALLY-CONTROLLED BILTMORE SpLIT OAK MODELS
CCL3924PTA, CCL3924NTA, CCL3930PTB AND CCL3930NTB
113097-01H34
www.desatech.com
Page 35
PARTS LIST
THERMOSTATICALLY-CONTROLLED BILTMORE SpLIT OAK MODELS
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions
listed under Replacement Parts on page 38 of this manual.
KEY
NO.
CCL3924PTA CCL3924NTA CCL3930PTB CCL3930NTB
pART NUMBER
DESCRIpTIONQTY.
1111340-02 111340-02 111340-01 111340-01 Front Log (#1)1
2111341-02 111341-02 111341-01 111341-01 Middle Log (#2)1
3111342-02 111342-02 111342-01 111342-01 Back Log (#3)1
4111343-02 111343-02 111343-01 111343-01 Left Back Crossover Log
(#4)
5111344-01 111344-01 111344-01 111344-01 Left Top Crossover Log
(#5)
6111345-02 111345-02 111345-01 111345-01 Right Bottom Crossover
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions
listed under Replacement Parts on page 38 of this manual.
Note: Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
pARTS UNDER WARRANTY
Contact authorized dealers of this product. If they
can’t supply original replacement part(s), contact
your nearest Parts Central (see page 39) or call
DESA Heating Products’ Technical Service Department at 1-866-672-6040 for referral information.
When calling DESA Heating Products, have ready
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to
the factory.
pARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they
can’t supply original replacement part(s), contact your
nearest Parts Central (see page 39) or call DESA
Heating Products at 1-866-672-6040 for referral
information.
When calling DESA Heating Products, have ready
• model number of your heater
• the replacement part number
ACCESSORIES
Purchase these replace accessories from your local dealer. If they can not supply these accessories,
call DESA Heating Products’ Sales Department at
1-866-672-6040 for referral information. You can
also write to the address listed on the back page
of this manual.
EQUIpMENT SHUTOFF VALVE
GA5010
For all models. Equipment shutoff valve with 1/8"
NPT tap. Fits 1/2" NPT pipe.
For all models. Helps deect heat away from
mantel or wall above replace.
DAMPER CLAMP - GA6080
(Not Shown)
Permanently opens chimney flue damper for
vented operation. Can be used only with nonthermostat accessories.
LAVA ROCK - GA6060
(Not Shown)
For all models. Order when additional rock is
desired. (2 lb. bag)
www.desatech.com
113097-01H38
Page 39
PARTS CENTRAL
These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs
by providing original replacement parts and accessories.
Always specify model and serial numbers when communicating with the factory
The only warranty applicable is our standard written warranty We make no other warranty, expressed or implied
LIMITED WARRANTY
COMFORT GLOW VENT-FREE GAS LOG HEATERS
DESA Heating Products warrants this product to be free from defects in materials and components for two (2)
years from the date of rst purchase, provided that the product has been properly installed, operated and maintained
in accordance with all applicable instructions To make a claim under this warranty the Bill of Sale or cancelled
check must be presented
This warranty is extended only to the original retail purchaser This warranty covers the cost of part(s) required
to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Heating
Products Authorized Service Center Warranty part(s) MUST be obtained through authorized dealers of this product
and/or DESA Heating Products who will provide original factory replacement parts Failure to use original factory
replacement parts voids this warranty The heater MUST be installed by a qualied installer in accordance with
all local codes and instructions furnished with the unit
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts
that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by
improper installation Travel, diagnostic cost, labor, transportation and any and all such other costs related to
repairing a defective heater will be the responsibility of the owner
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE
OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS
ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE AND DESA HEATING PRODUCTS’
LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING
INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of
incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on
damages may not apply to you
This warranty gives you specic legal rights and you may also have other rights that vary from state to state