Comfort Glow Brentwood LCF18, Brentwood LCF24 Owner's Operation & Installation Manual

For more information, visit www.desatech.com
WARNING: If the information in this manual is not fol-
lowed exactly, a re or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other appliance.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
— Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
VENTED DECORATIVE NATURAL GAS LOGS
OWNER’S OPERATION AND INSTALLATION MANUAL
RGA 2-72
APPROVED
TESTED AND
LISTED BY
BRENTWOOD
MODELS LCF18 AND LCF24
www.desatech.com
115043-01D2
WARNING: Improper installation, adjustment, altera­tion, service or maintenance can cause injury or prop­erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi­tional information consult a qualied installer, service agency or the gas supplier.
WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built replace, constructed of noncombustible material and connected to a working ue. (See page 6 for minimum ue opening.
WARNING: This is a decorative gas appliance. It uses air (oxygen) from the room in which it is installed. Provi­sions for adequate combustion and ventilation air must be provided. Refer to the National Fuel Gas Codes, ANSI
Z233.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
This appliance may be installed in an aftermarket,* per­manently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indi­cated on the rating plate.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
State of Massachusetts: The installation must be made by a licensed plumber or gas tter in the Commonwealth of Massachusetts.
TABLE OF CONTENTS
Safety Information ............................................... 3
Product Identication ........................................... 4
Local Codes......................................................... 4
Unpacking............................................................ 5
Optional Product Features................................... 5
Installation ........................................................... 5
Operating Appliance .......................................... 10
Cleaning and Maintenance ................................ 12
Service Hints ..................................................... 12
Technical Service............................................... 12
Replacement Parts ............................................ 12
Troubleshooting ................................................. 13
Illustrated Parts Breakdown and Parts List........ 16
Accessories ....................................................... 18
Warranty Information ............................ Back Page
www.desatech.com
115043-01D 3
WARNING: This appliance is equipped for natural gas. An optional propane/LP conversion kit must be installed for use with propane/LP gas.
WARNING: Do not allow fans
to blow directly into the replace. Avoid any drafts that alter burner ame patterns.
WARNING: Installed decora-
tive glass door enclosures must be fully opened when operating this gas appliance.
Due to high temperatures, the appliance should be located out of trafc and away from furniture and draperies.
Do not place clothing or other ammable material on or near the appliance. Never place any objects on the appliance.
Appliance assembly becomes very hot when in use. Keep chil-
dren and adults away from hot
surface to avoid burns or clothing ignition. Appliance will remain hot for a time after shutdown. Allow surface to cool before touching.
Carefully supervise young chil-
dren when they are in the room
with appliance.
You must operate this appliance with a replace screen in place. Make sure replace screen is closed before running appliance.
Keep the appliance area clear and free from combustible ma­terials, gasoline and other am­mable vapors and liquids.
SAFETy INFORMATION
WARNING: This product con-
tains and/or generates chemicals
known to the State of California
to cause cancer or birth defects or other reproductive harm.
WARNING: Keep ue open
when operating unit.
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate or service this log set. Improper use of this log set can cause serious injury or death from burns, re, explosion, electrical shock and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning resemble the u, with headaches, dizziness or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced. Some
people are more affected by carbon monoxide than
others. These include pregnant women, people with heart or lung disease or anemia, those under the inuence of alcohol and those at high altitudes.
Natural Gas: Natural gas is odorless. An odor-
making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this log set.
WARNING: Any change to this log set or its controls can be dangerous.
WARNING: Do not use a blow­er insert, heat exchanger insert or other accessory not approved for use with this appliance.
www.desatech.com
115043-01D4
1. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your building
• immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
• if you cannot reach your gas supplier, call the re department
2. Never install the log set
• in a recreational vehicle
• where curtains, furniture, clothing, or other ammable objects are less than 42 inches from the front, top, or sides of the log set
• in high trafc areas
• in windy or drafty areas
3. Before installing in a solid fuel burning replace, the chimney ue and rebox must be cleaned of soot, creosote, ashes and loose paint by a qualied chimney cleaner. Creosote will ignite if highly heated. Inspect chimney ue for damage. If dam­aged, repair ue before operating appliance.
4. This log set is designed to be smokeless. If logs ever appear to smoke, turn off appliance and call a qualied service person. Note: During initial operation, slight smoking could occur due to log curing and the burning of manufacturing residues. You may wish to add more ventilation by opening a window.
5. To reduce the creation of soot, follow the instructions in Cleaning and Maintenance, page 12.
6. The installation and provisions for combustion and ventilation air must conform with the Na-
tional Fuel Gas Code, ANSI Z233.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
7. Do not run log set
• where ammable liquids or vapors are used
or stored
• under dusty conditions
8. Do not burn solid fuel in the replace after installing the log set. Do not use this log set to cook food or burn paper or other objects.
9. Do not use appliance if any part has been exposed to or under water. Immediately call a qualied service technician to inspect the
room appliance and to replace any part of
the control system (if using GA9050A or GA9150A) and any gas control which has been under water.
SAFETy INFORMATION
Continued
10. To help prevent breakage, new logs must be broken-in (see Curing Logs page 11).
11. Turn log set off and let cool before servicing, installing, or repairing. Only a qualied ser­vice person should install, service, or repair log set.
12. Provide adequate clearances around air openings.
13. This vented gas log set may not be installed in a bedroom or bathroom in the Common­wealth of Massachusetts.
PRODUCT
IDENTIFICATION
Figure 1 - Product Identication (Dual
Burner Shown)
Hearth Kit Model ____________________
Serial Number ______________________
Log Set Model ______________________
Grate
Burner Pan
Burner Manifold
Burner Inlet Fitting
Burner Clamp
Grate Steps
LOCAL CODES
Install and use log set with care. Follow all local codes. In the absence of local codes, use the lat-
est edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
www.desatech.com
115043-01D 5
UNPACkING
CAUTION: Do not remove the
data plates from the burner pan. The data plates contain impor­tant product information.
1. Remove logs, hearth kit, pan materials, and hardware from carton.
2. Remove all protective packaging applied to logs and base for shipment.
3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought the product.
OPTIONAL PRODUCT
FEATURES
ON/OFF SAFETY VALVE/PILOT KIT AND PROPANE/LP CONVERSION
An optional valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. You must use this optional system for LP conversion. See Accessories, page 18.
REMOTE CONTROL READY
(MILLIVOLT) SAFETY VALVE/PILOT KIT
An optional millivolt valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. This system may be connected to a wall switch or hand-held wireless remote control. See Accessories, page 18.
REMOTE CONTROL ACCESSORIES
There is an optional hand-held ON/OFF remote control that can be purchased separately for this log set. You must use the millivolt valve/safety pilot kit to use remote accessories with this appliance. See Accessories, page 18.
A wall switch is also available for this appliance. You must use the millivolt valve/safety pilot kit to use the wall switch with this appliance. See Accessories, page 18.
INSTALLATION
CAUTION: Do not remove the
data plates attached to the burner pan. The data plates contain im­portant warranty information.
WARNING: Before installing in a solid fuel burning replace, the chimney ue and rebox must be cleaned of soot, creo­sote, ashes and loose paint by a qualied chimney cleaner. Creo­sote will ignite if highly heated. A dirty chimney ue may create and distribute soot within the house. Inspect chimney ue for damage. If damaged, repair ue before operating appliance.
NOTICE: Installation, service,
and repair of this appliance must be performed by a qualied in­staller, service agency, company or gas supplier experienced with this type of gas appliance. Only factory authorized components
listed in these instructions may
be used in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdic­tion. Any modications to this
kit, or use of unauthorized
components or accessory items will void the manufacturer’s
warranty, and may result in a
hazardous condition.
FLUE OPENING SPECIFICATIONS
Note: This vented appliance must be installed only in a solid-fuel burning replace with a working ue and constructed of noncombustible material.
The charts in Figure 2, page 6 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specica­tions shown are applicable before installation is attempted.
www.desatech.com
115043-01D6
The replace must include a working ue and venting system with the minimum openings shown in the Figure 2.
INSTALLATION
Continued
Figure 2 - Technical Information Charts
Model
Burner
Descrip-
tion
BTU Input
(Natural
Gas)
Min. Vent
Opening
LCF18 18" Dual 55,000 8" LCF24 24" Dual 60,000 8"
Minimum Fireplace Dimensions
Model
Front
Width
Back
Width*
Depth Height
LCF18 28" 18" 14" 16" LCF24 29.75" 17" 15.5" 18"
* At depth Indicated
Fuel Inlet Pressure
Specications (W.C.)
Min. Max.
N.G. 5.5" 10.5"
Burner Orice Sizing
Log Size
Natural Gas
In. Num.
18" .120 31 24" .129 30
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural gas, you must install ON/OFF Safety Valve/Pilot Kit (see Accessories, page 18). Call dealer where you bought log set.
If the replace does not have a gas supply shutoff valve, one must be installed.
VENTING SPECIFICATIONS FOR
INSTALLATION
The replace chimney ue and vent must be draft­ing properly. To check the vent for proper drafting: Light a tightly rolled newspaper on one end and place it at the inside front edge of the replace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the ame and remove any obstruction until proper venting is achieved.
The chimney ue must remain open a minimum of 3" at all times during the operation of this log set.
For Massachusetts Residents Only
Installation of this vented gas log set in the Com­monwealth of Massachusetts requires the damper be permanently removed or welded in the fully open position.
INSTALLING DAMPER CLAMP
Secure the damper stop clamp provided to the leading edge of the damper as shown in Figure 3. If for any reason this clamp doesn't work on your replace, another suitable clamp or permanent stop must be installed, or the damper blade must be cut or removed.
CONNECTING TO GAS SUPPLY
WARNING: A qualied ser­vice person must connect log set to gas supply. Follow all local codes.
Installation Items Needed
Before installing log set, make sure you have the items listed below.
• piping (check local codes)
• sealant (resistant to Propane/LP gas)
• equipment shutoff valve
• test gauge connection
• adjustable (crescent) wrench or pliers
• sediment trap
• tee joint
• pipe wrench
Figure 3 - Attaching Damper Clamp
Damper Clamp
Damper Clamp
Damper
Manufactured
Fireplace
Masonry Fireplace
Damper
Loading...