comfortel Vogue CleanSpa Pedi Owner's Manual

#6790 VOGUE CLEANSPA PEDICURE CHAIR
vogue cleanspa pedi
comfortel.com.au
owners manual
CLIENTS WITH ANY INFECTIOUS SKIN OR NAIL CONDITIONS, OR ANY OTHER PEDICURE CONTRAINDICATIONS.
CLIENTS WHO SUFFER FROM SERIOUS NECK OR BACK PROBLEMS MAY BE CONTRAINDICATED TO THE SHIATSU MASSAGE.
PREGNANT CLIENTS SHOULD NOT USE MASSAGE FUNCTION
NEVER USE ANY PLUMBING FITTINGS
EG. TAPS OR FOOT RESTS TO LIFT OR MOVE
PEDICURE SPA
CONTRAINDICATIONS
CAUTION
GENERAL SAFETY
1. Read carefully and keep these instructions in a safe place.
2. Use this product only for its intended function and do not use attachments not recommended by the manufacturer.
3. Never use this product if the flexible power cord is damaged and inspect regularly to ensure
PLUMBING
1. This unit must be plumbed by a licensed plumber.
IMPORTANT PLEASE READ THESE SAFETY INSTRUCTIONS
DO NOT ALLOW CHILDREN AROUND THE PEDICURE SPA WHEN IN USE
ALL PLUMBING MUST BE COMPLETED BY A LICENSED PLUMBER
IMPORTANT
IMPORTANT
DO NOT USE IF FLEXIBLE POWER CORD IS DAMAGED. ANY REPAIRS MADE TO PEDICURE SPA MUST BE CONDUCTED BY A QUALIFIED ELECTRICIAN ONLY.
ALL ELECTRICAL GPO'S MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH AUSTRALIAN STANDARDS.
CAUTION IMPORTANT
PRECAUTIONS
1. This product is for indoor use only and is not recommended for use on carpet or wood floors.
2. DO NOT USE if you are diabetic, have poor circulation, or if any area of your feet or legs is inflamed or has an open sore. Consult your physician before using if you have any kind of fungal infection, swelling, fracture or persistent pain.
3. To reduce risk of injury, do not permit children to use this unit unless they are closely supervised at all times.
4. Excessive water temperature is dangerous, always check the water temperature BEFORE use. Maximum temperature of the water should never exceed 38ºC.
5. Do not step or stand in foot basin.
6. Always enter and exit the Pedicure Spa slowly and carefully.
7. Maximum load for the spa chair is 120kg.
8. Proper installation in accordance with this manual is required. Failure to do so may result in serious injury and/ or warranty will be null and void. You must have a qualified licensed plumber connect the spa in place safely.
9. There are health regulations and codes that apply locally as well as some which are specific to each state. It is the owners responsibility to ensure they comply with all applicable regulations and codes.
ELECTRICAL APPLIANCES
1. All GPO’s must be installed by a qualified Electrician in accordance with local electrical standards.
2. DO NOT allow children to operate the electric motors in this product.
3. Turn the power o and remove the plug when not in use.
4. Turn the power o and remove the plug when cleaning.
5. Do not let the power cord get damaged in any way.
6. Keep the power cord away from heat sources.
7. Do not use an extension cord unless the cord complies with local electrical safety standards.
8. Periodically inspect the power cord for signs of damage.
9. Do not operate any electrical item with a damaged power cord.
GETTING STARTED
1
2
3
4
7
8
9
6
11
5
1 Chair with Massage 2 Armrest 3 Shiatsu Massage Remote Control 4 Manicure-Tray 5 Wellness Chromotherapy Tub 6 Shower head 7 Footrest 8 On/O Drainage with Discharge 9 On/O Hot/Cold Water Flick Mixer 10 On/O Whirpool Jets & LED Light 11 Bag Hook 12 Magnacleanse Magnetic Jet 13 LED Chromotherapy Light Basin 14 Drain Stopper
12
13
14
PEDICURE SPA ASSEMBLY
ABOUT
VOGUE
CleanSpa Pedicure Chair
The ultimate in luxury pedicure spas, this pedicure spa is designed to be used with disposable Cleanspa basin liners.
FEATURES:
· Electric Seat Adjustment
· Chromotherapy LED Basin
· Shiatsu multi-function massage system
· Magnetic Jet & Drainage Pump
10
ALL PLUMBING MUST BE COMPLETED BY A LICENSED PLUMBER
IMPORTANT
ALL ELECTRICAL GPO'S MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH AUSTRALIAN STANDARDS.
IMPORTANT
POSITIONING
BEFORE INSTALLING YOU SHOULD CONSIDER THE FOLLOWING
• Allow for the necessary room around the unit for free movement.
• If installing against a wall, a minimum distance of 540mm between wall and bottom back of basin is required to allow free movement behind the chair. (Diagram A)
• For positioning please allow necessary space between Pedicure Spas (Diagram B)
DIAGRAM A
DIAGRAM B
DIAGRAM C
ø215
1370 540
1910
GPO OPTION 2
GPO OPTION 1
PLUMBING OPTION 1
PLUMBING OPTION 2
All measurements are in mm.
1525
762.5
600
140
660
215
ASSEMBLY: CHAIR
ASSEMBLY: REMOVING THE BACK REST
1 2
3
4
Line-up backrest frame and locking screws to the open trenches located on seat frame and system will auto lock the backrest frame.
Line-up & install 2 screws beneath the seat cushion onto seat frame.
Attaching Armrests Step 1: Put 2 plastic ringbolt Ø 42 mm and springs Ø37 mm on the core of arm rest. Step 2: Push the arm rest enough to place the ringbolt Ø 30mm, turn rivet Ø 13mm Step 3: Step 3: Use wrench to turn rivet Ø 13mm until cannot turn more and then put the cap cover on the screw.
Connect actuator power connectors by following wire's color.
1
2
3
Lift up and release the latch located on the left under sides of the back rest
Pull up this lock ring to remove arm-rest
Lift up this latch to unlock and remove the back rest
Plastic ringbolt Ø 42 mm
Springs Ø37 mm
Ringbolt Ø 30 mm
Rivet Ø 13mm
Plastic Cap cover
HOT AND COLD WATER SUPPLY LINES
1. Carefully connect 1/2" ID supply hoses (not provided) to fresh water source. Shut-o valves (not provided) should be utilised. Valves should be placed outside the tub for easy access.
2. Make sure to remove any and all debris and/or dust from the current hot/cold water pipes before connecting to the spa. To remove debris, turn on water and drain into a bucket or container (See illustration)
ALWAYS USE NEW HOT/COLD WATER HOSES WHEN CONNECTING SPA TO PREVENT DEBRIS FROM CLOGGING DRAIN
OPTION 1: PLUMBING FLOW PATTERN FOR GRAVITY DRAIN
INSTALLATION: PLUMBING
Underground to Waste
1 1/4” Flex Hose
with Removable Connection
1 1/4” Flex Hose with Removable Connection
Drain
1/2” Hot/Cold Water Inlet
1/2 “ Hot/Cold Water Inlet
1370
540
1910
CONNECTION
1. Connect waste pipe (Installed) to 32mm
waste outlet.
2. Connect hot and cold (½”connection) to respective hot and cold supplies.
ELECTRICAL REQUIREMENTS
1 x10 amp GPO required 240V, 50/60Hz, 2A
PLUMBING AND WASTE
Follow diagram above for plumbing specifications. All plumbing must be installed by a licensed plumber in accordance with local regulations.
DRAIN
The extraction drain pump is included with the unit. It designed to pump the waste from the pedicure spa where there is insucient fall to allow gravity drainage. Refer to Diagram G for Drain System Recommendation.
Extraction Pump can pump up to 2meters.
DIAGRAM C DIAGRAM D
INSTALLATION: PLUMBING
HOT AND COLD WATER SUPPLY LINES
1. Carefully connect 1/2" ID supply hoses (not provided) to fresh water source. Shut-o valves (not provided) should be utilised. Valves should be placed outside the tub for easy access.
2. Make sure to remove any and all debris and/or dust from the current hot/cold water pipes before connecting to the spa. To remove debris, turn on water and drain into a bucket or container (See illustration)
ALWAYS USE NEW HOT/COLD WATER HOSES WHEN CONNECTING SPA TO PREVENT DEBRIS FROM CLOGGING DRAIN
OPTION 2: PLUMBING FLOW PATTERN WITH EXTRACTION/DRAIN PUMP
DRAIN SYSTEM RECOMMENDATION
To Waste
To be connected to an indirect waste connector
Extraction Pump
1/2 “ Hot/Cold
Water Inlet
ø215
1370
540
1910
1 1/4” Flex Hose with Removable Connection
Extraction Pump
1/2 “ Hot/Cold Water Inlet
DIAGRAM E DIAGRAM F
DIAGRAM G
To Waste
PLUMBING AND WASTE
Follow diagram above for plumbing specifications. All plumbing must be installed by a licensed plumber in accordance with local regulations.
REAR DRAIN
The extraction drain pump is included with the unit. It designed to pump the waste from the pedicure spa where there is insucient fall to allow gravity drainage. Refer to Diagram G for Drain System Recommendation. Extraction Pump can pump up to 2 meters.
CONNECTION
1. Connect waste pipe (Installed) to 32mm waste outlet.
2. Connect hot and cold (½”connection) to respective hot and cold supplies.
ELECTRICAL REQUIREMENTS
1 x10 amp GPO required 240V, 50/60Hz, 2A
GENERAL OPERATION
Turn Hot/Cold Flick Mixer to adjust optimal water temperature. To turn water on: Pull Hot/Cold Flick Mixer upwards. Water will fill up.
To turn water o: Push Hot/Cold Flick Mixer to turn o water.
OPERATION & DRAINAGE
8
10
9
DRAINAGE
CLOSE DRAIN TO TURN OFF DRAINAGE
PUMP WHEN BOWL IS EMPTY
When activating the switch, it will raise the drain-stopper and power up the drain pump (if exist) at the same time.
To drain water: Turn the drain knob clockwise. Drain pump is activated.
To turn o the drain pump: Turn the drain knob counter-clockwise.
NOTE: REMEMBER TO RESET THE DRAIN KNOB TO THE VERTICAL POSITION TO CLOSE THE DRAIN STOPPER PRIOR TO FILLING WITH WATER.
DIAGRAM H
USER TIP
8 On/O Drainage with Discharge 9 On/O Hot/Cold Water Flick Mixer 10 On/O Whirpool Jets & LED Light
FUNCTIONS
OPERATION: CALF SUPPORT
OPERATION: SHITASHU MASSAGE REMOTE
OPERATING THE REMOTE
1 POWER ON/OFF
Press Power Button to start Auto mode. Press again to turn o massage.
Auto and Manual mode will run for duration of 20min.
2 MASSAGE MODE ON/OFF
Press any button (Rolling/Spot, Kneading, Tapping, Combine) to enter Manual mode
Press Rolling/Spot to stop rolling up/down and stop at desired spot.
3 INTENSITY ON/OFF
Press Intensity button to select tapping intens
4 VIBRATION ON/OFF
Vibro Button is an option. Pressing this button will resume with Tapping action.
5 SEAT ADJUSTMENT
Press any chair button (Recline, Incline, Backward, Forward) to move the chair to desired positions
1
2
2
4
3
5
· Drain water from the tub by piecing the bag above the drain. Once water is drained dispose of the Clean Spa Liner.
· We recommend cleaning with Spa Giene or Pedi Giene. These are approved spa cleaners and hospital grade disinfectants. They will remove oily product residues, break down biological wastes (skin cells, oils etc) and disinfect the foot bath to stop cross-contamination and the spread of infections.
· Spray the inside of the Spa with diluted (1:4 dilution) Spa Giene. Eg.100mLs of spa cleaner to 300mL water Or 250mL spa cleaner to 750mL water.
· Use the hand held shower and a cloth or sponge to rinse any residue out of the tub.
· Wipe the inside of the foot bath clean with a non­ abrasive cloth (eg Chux cloth or sponge) and dry all surfaces thoroughly.
· The chair, foot-rest and surrounding surfaces may be wiped clean with a soft cloth and mild non-abrasive surface cleaning agent.
· Add a fresh disposable Clean Spa Liner for the next client.
CLEANING RECOMMENDATIONS
· Remove the magnetic jet cap from the bowl.
· Turn Counter-clockwise to open the cap.
· Scrub clean each part of the magnetic jet cap.
· Soak the magnetic jet cap in diluted Spa Giene or Pedi Giene for 3-5 minutes
· Rinse thoroughly and dry with a soft lint free cloth
· Clip the magnetic jet cap inside a fresh liner ready to use.
FOOT BATH
MAGNACLEANSE- MAGNETIC JET
THE PEDICURE SPA TUB/FOOT BATH MUST BE CLEANED BETWEEN EVERY CLIENT
THE MAGNETIC CAP MUST BE CLEANED BETWEEN EVERY CLIENT
CLEANING RECOMMENDATIONS
CHAIR & UPHOLSTERY
· All upholstery needs some care; good housekeeping will help to prolong the life of any upholstered products.
· Avoid extreme temperatures. Extreme cold can make your vinyl prone to cracking, while extreme heat can cause permanent stretching.
· Avoid exposing your products to direct sunlight for prolonged periods of time.
· Clean regularly (weekly) to remove body oils which cause hardening.
· To clean use a sponge which has been moistened in warm soapy water.
· After cleaning with a sponge, dry with a soft, clean cloth.
· Stubborn grime may require gentle scrubbing with a soft brush.
DO NOT USE
· furniture polishes
· bleach
· detergent
· abrasive cleaners
· steel wool
Damage caused by any improper treatment is not covered by the product warranty
GENERAL SURFACES
· To clean use a sponge which has been moistened in warm soapy water.
· After cleaning with a sponge, dry with a soft, clean cloth.
· Stubborn grime may require gentle scrubbing with a soft brush.
DO NOT USE
· furniture polishes
· bleach
· detergent
· abrasive cleaners
· steel wool
A periodic inspection of all components and fasteners should be made to ensure that your pedicure spa is structurally intact and functioning properly.
Damaged and broken parts should be replaced and loose fasteners tightened.
All maintenance to be carried out by a suitably qualified tradesperson.
MAINTENANCE
The information contained in this document is subject to change without notice and should not be construed as a commitment by Comfortel Furniture Pty Ltd.
Comfortel Furniture Pty Ltd. assumes no responsibility for any errors that may appear in this document nor does it make expressed or implied warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
Comfortel Furniture Pty Ltd. shall not be liable for incidental or consequential damages in connection with or arising out of the use of this document and the program material.
PRODUCT CODE
PURCHASE DATE INVOICE NUMBER
NOTE YOUR PURCHASE DATE & INVOICE NUMBER FOR FUTURE REFERENCE
PLEASE RETAIN THIS INFORMATION FOR FUTURE REFERENCE
For more information about our products and services, contact us at comfortel.com.au
comfortel.com.au
1 x10 amp GPO required 240V, 50/60Hz, 2A
#6790 VOGUE PEDICURE SPA
©Comfortel Furniture 1997-2018. All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without written consent of Comfortel Furniture Pty Ltd.
PERIOD AND DESCRIPTION PRODUCTS
12 MONTHS PARTS & LABOR All products
2 YEARS PARTS ONLY All products excluding small electrical appliances
3 YEARS PARTS ONLY All Linak electric actuators
5 YEARS PARTS ONLY Taps cartridge, Ceramic basins
TERMS AND CONDITIONS
For more information about our terms and conditions including warranty, please refer to our website.
WARRANTY PERIOD
Revision Date: 05.07.2018
Loading...