HALO SAFETY RING
Product Number 77402 comes with same items as Product Number 77401 except one extra Halo Safety Ring Circle (77104)
PARTS INCLUDED
ITEM QTY DESCRIPTION
1 1 Halo Safety Ring Circle
2 2
3 2 Telescoping Connector Spring Clip
4 2 Rubber Tube Separator
- 1
5 2 Screw - M8 x 1.25 x 45mm, SHCS, Zinc
6 4 M8 Split Washer, Zinc
Halo Safety Ring C/Channel Circle Mounting Bracket
for Panacea 1500 Bed
Hardware Kit for Both the Halo Safety Ring Single
Circle (77401) and Halo Safety Ring Double Circle
Unit Product Number (77402) for Panacea 1500 Bed
MODEL: 77401
MODEL: 77402
SINGLE SIDED MOUNT WITH CIRCLE MOUNTING BRACKET
MOUNT FOR PANACEA 1500 HOSPITAL BED.
DOUBLE SIDED MOUNT WITH CIRCLE MOUNTING
BRACKET MOUNT FOR PANACEA 1500 HOSPITAL BED.
ITEM QTY DESCRIPTION
7 4 M8 Washer, 1”OD, Zinc
8 2 M8 x 1.25 Nylon Insert Nut, Zinc
9 2 M8 Screw Spacer, Zinc
10 2 Plastic Tube Cap
11 1 6mm T Shape Allen Wrench (Not Shown)
1
1 OF 3
PANCEA BED FRAME
(NOT INCLUDED)
3
4
8
9
10
2
7
6
5
IS-77401HALO-77402HALO
REV0114
Toll Free 800.564.9248
www.comfortcompany.com
509 South 22nd Ave Bozeman, MT 59718
HALO SAFETY RING
Remove any existing bed rails or pins that are attached to the 2 holes on both side of the mattress frame.
MODEL: 77401
MODEL: 77402
1
Attach Item 2 to the bed frame using Items 5 – 9 as shown below. Fully tighten the screws to secure the mounting
2
bracket on the bed frame.
Repeat on opposite side of bed.
3
You are now ready to install the Halo Safety Ring (77104) into the Circle Mounting Brackets (77405).
4
Note: Based on whatever unit is purchased you would need to repeat the installation process of the
Halo Safety Ring if you purchased a (77402), Halo Safety Ring Double Sided Circle Unit.
- WARNING -
• Serious injury or death can result if the Halo Safety Ring is not properly installed.
• DO NOT use this product or any available optional equipment without first completely reading & understanding these instructions. If
you are unable to understand the warnings, cautions or instructions, contact customer service at (800) 564-9248 for assistance before
attempting to use this equipment - otherwise, injury or damage may occur.
• The Halo Safety Ring is not intended to prevent an individual from inadvertently rolling out of bed. DO NOT use the Halo Safety Ring
for restraint purposes. DO NOT use to transport or move bed.
• ENTRAPMENT MAY OCCUR. Proper patient assessment and monitoring, and proper maintenance and use of equipment is required
to reduce the risk of entrapment. Variations in mattress thickness, size or density could increase the risk of entrapment. Visit the FDA
website at http://www.fda.gov to learn about the risks of entrapment.
• Remove bed rails and all bed rail mounting brackets prior to installation of the Halo Safety Ring.
• The Halo Safety Ring is rated for use with patients weighing up to 1000 lbs. Although the Halo Safety Ring is rated for such use, it may
become deformed or broken if excessive force is exerted on the device.
• After installation, verify the mattress is in firm contact with the Halo Safety
Ring and that the mattress cannot shift away.
• Detent pins used to rotate the Halo Safety Ring must be engaged with holes
in the Halo Bracket prior to use, refer to Figure 1.
• The Halo Safety Ring must be perpendicular (90º) to the bed if used to assist
the user out of a chair. Detent pins must be engaged with the holes in the
Halo Safety Ring bracket prior to use as a patient assist.
DETENT PINS ENGAGED WITH
HALO SAFETY RING BRACKET
FIGURE 1
2 OF 3
WARNING!
IMPROPER INSTALLATION CREATES A RISK OF ENTRAPMENT
In order to avoid entrapment, the mattress must remain in rm contact with the Halo Safety Ring
on both sides of the bed. If a Halo Safety Ring is only installed on one side of the bed, the mattress
must also remain in rm contact with the mattress stay/bracket on the other side of the bed.
IS-77401HALO-77402HALO