COMFORT-AIRE SVH09SA-0, SVH12SA-0, SVH12SA-1, SVH18SA-1, SVH09SA-1 Remote Control Manual

...
Remote Control Manual
SVH Series
Inverter Single Zone Ductless Mini-Split
SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1
SVH18SA-1 SVH24SA-1
www.marsdelivers.com
Remote Control Manual - SVH 09/12/18/24 Series
Model
Rated Voltage
8m
3.0V(Dry batteries R03/LR03¡2)
RG51F/EU1, RG51F1/EU1, RG51F3/EU1
Remote Controller Specifications
Environment
Signal Receiving Range
TEMP
AUTO COOL DRY HEAT
O
SET TEMPERATURE( F)
62 F~86 F
CONTENTS
Remote controller Specifications...................................................
Operation of buttons .................. ..................................................
Indicators on LCD ..........................................................................
How to use the buttons .................................................................
Auto operation.................................................................................
Cooling/Heating/Fan operation......................................................
Dehumidifying operation ...............................................................
Timer operation...............................................................................
Handling the remote controller ......................................................
2
3
6
7
7
7
8
9
12
Remote Control Manual - SVH 09/12/18/24 Series
Remote Controller Specifications
Model
Rated Voltage
Signal Receiving Range
Environment
SET TEMPERATURE( F)
AUTO COOL DRY HEAT
TEMP
RG51F/EU1, RG51F1/EU1, RG51F3/EU1
3.0V(Dry batteries R03/LR03¡2)
8m
O O
62 F~86 F
O
FAN HIGH MED LOW
AUTO COOL DRY HEAT
SET TEMPERATURE( F)
TEMP
O
FAN HIGH MED LOW
MODE
SWING
CLEAN AIR
ON/OFF
ECO
RESET LOCK
LED DISPLAY
FAN SPEED
TIMER ON
TIMER OFF
TURBO
Model: RG51F3/EU1
RG51F/EU1(This model does not have clean air button)
MODE
SWING
SWING
ON/OFF
ECO
RESET LOCK
FAN SPEED
LED DISPLAY
TURBO
TIMER ON
TIMER OFF
Model : RG51F1/EU1
2
Remote Control Manual - SVH 09/12/18/24 Series
Operation of buttons
TEMP
AUTO COOL DRY HEAT
MODE
ECO
ON/OFF
RESET LOCK
1
4
5
6 7
8
3
SET TEMPERATURE
SWING
SWING
LED DISPLAY
Model : RG51F1/EU1
Operation of buttons
SET TEMPERATUREO( F)
AUTO COOL DRY HEAT
TEMP
FAN HIGH MED LOW
2
MODE
ON/OFF
FAN SPEED
3
SWING
4
CLEAN
5
AIR
RESET LOCK
6
7
ECO
LED DISPLAY
TIMER ON
TIMER OFF
TURBO
8
Model: RG51F3/EU1
RG51F/EU1(This model does not have clean air button)
1
10
11
12
13
14
TEMP UP Button
1
Push this button to increase the indoor temper­ature setting in 1 F increments to 86 F.
TEMP DOWN Button
2
Push this button to decrease the indoor temper­ature setting in 1 F increments to 62 F.
NOTE£Temperature contol is not available in Fan mode.
NOTE: Press and hold UP and DOWN buttons together for 3 seconds will alternate the temper­ature display between the C & F scale.
9
3
MODE Button
Press this button to modify the air conditioner
O O
O O
OO
mode in a sequence of following:
AUTO
COOL
DRY
HEAT FAN
SWING/SWING Button
4
Used to stop or start horizontal louver move­ment or set the desired up/down air flow direction. The louver changes 6 degree in angle for each press. If keep pushing more than 2 seconds, the louver will swing up and down automatically.
ECO Button:
5
Used to enter the energy efficient mode. Under cooling mode, press this button, the remote controller will adjust the temperature automatically to 75 F, fan speed of Auto to
O
save energy(but only if the set temperature is less than 75 F). If the set temperature is between 75 F and 86 F, press the ECO
O
O O
button, the fan speed will change to Auto, the set temperature will remain unchanged.
NOTE:
Pressing the TURBO and SLEEP button, modifying the mode or adjusting the set temperature to less than 75 F will stop
O
ECO operation.
3
Remote Control Manual - SVH 09/12/18/24 Series
Operation of buttons
Under ECO operation, the set temperature should be 75 F or more. it may result in
O
insufficient cooling. If you feel uncomfortable, just press the ECO button again to stop it.
SET TEMPERATUREO( F)
AUTO COOL DRY HEAT
FAN HIGH MED LOW
CLEAN AIR Button(applicable to RG51F3)
6
Disable/Active clean air function. When the clean air function is initiated, the Ionizer/ Plasma Dust Collector(depending on models)
TEMP
1
MODE
ON/OFF
FAN SPEED
3
SWING
4
5
SWING
RESET LOCK
6 7
ECO
LED DISPLAY
TIMER ON
TIMER OFF
TURBO
2 9
10
11
12 13
is energized and will help to remove pollen and impurities from the air.
Swing Button(applicable to RG51F1)
Used to stop or start vertical louver movement and set the desired left/right air flow direction. The vertical louver changes 6 degree in angle for each press.
RESET Button
7
Once the recessed RESET button is pressed,
8
14
all of the current settings will be cancelled and the controller will return to the initial settings.
Model : RG51F1/EU1
8
LED Button
Disable/Active indoor screen Display. When pushing the button, the indoor screen display is cleared, press it again to light the display.
9
ON/OFF Button Operation starts when this button is pressed
and stops when the button is pressed again.
10
FAN SPEED Button Used to select the fan speed in four steps:
Auto Low Med High
11
TIMER ON Button
Press this button to initiate the auto-on time sequence. Each press will increase the auto-timed setting in 30 minute increments. When the setting time displays
10.0, each press will increase the auto­timed setting 60 minute increments. To cancel the auto-timed program, simply adjust the auto-on time to 0.0.
4
Loading...