COMFORT-AIRE IR30S, IR60S Installation & Operation Manual

Radiant Infrared Electric Heater
IR30S and IR60S
FOR OUTDOOR COMMERCIAL USE ONLY
IP65 Rated for Wet Conditions
INSTALLATION &
OPERATION MANUAL
SPECIFICATIONS
TOTAL POWER
(WATTS)
CURRENT
(AMPS)
IR30S 208/240-1-60 2250/3000 10.8 / 12.5 IR60S 208/240-1-60 4500/6000 21.6 / 25.0
1
AITONS EQUIPMENT • Guelph, ON N1H 6H9 1-888-744-2911 www.aitons.com
This electric appliance produces infrared heat, and failure to follow
.
This heater is designed for outdoor commercial use only.
READ AND SAVE THESE INSTRUCTIONS!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury or property damage.
or liquids, including aerosol cans, in the vicinity of this heater while it is operating.
materials on or near the heater, or allow them to come in contact with the unit: rags, fabric, spray or aerosol cans, cleaning compounds, plastics or plastic containers, paper products, gasoline,
Do not install the heater close to furniture, curtains
(1.8 meters) between all sides of the heater and
Do not cover or otherwise obstruct the heater.
Do not use heater without wire guard in place.
WARNING
PERSONAL INJURY HAZARD
Do not touch the heater during operation. Burn or scald injury could result. The casing and components are extremely hot during operation.
Keep children away from the heater. Never leave an unsupervised child near the heater.
Because of injury risk, the heater should be operated only by individuals knowledgeable about the operation and familiar with the warnings and cautions listed in this manual.
Because of injury risk, this heater is not intended for use by persons with reduced physical, sensory or mental capabilities.
Heater is not for use in bathrooms, laundry areas
or other locations where unit could fall into a body of water.
WARNING
PERSONAL INJURY HAZARD–SERVICE
To avoid property damage, personal injury or death due to electrical shock, do not service the unit
the wired circuits from the main power supply.
Allow adequate time for the unit to cool down completely.
service technician.
Do not use the heater if the power cord is damaged.
electrician to replace the cord prior to use.
Do not use heater if it has been dropped or dam­aged in any way, until it has been inspected by an authorized service facility.
When cleaning heater or replacing emitter, disconnect wired circuits from the power supply. Be sure heater and/or emitter has cooled completely, before handling.
WARNING
INSTALLATION & USE
To avoid property damage, personal injury or death due to electrical shock, follow all instructions in this Installation and Operation manual.
bottom and back of unit must be met. Failure to
and must adhere to all local, state and national electric codes (NEC).
Heater must be grounded and hard wired.
Keep the power cable away from body of heater.
Do not use heater if power cord is damaged.
Do not insert or allow foreign objects to enter any of the heater openings. Electrical shock could result.
Never leave the heater unattended while it is operating.
Installation & Operation Radiant Infrared Heater
WARNINGS
2
AITONS EQUIPMENT
ELECTRICAL INSTALLATION
WARNING: To assure safe operation, installa-
must adhere to local, state and national electrical codes.
wet environment installations.
1. Supply voltage must correspond to the voltage indicated on unit’s rating plate.
2. The cord from each terminal box must be hard wired and properly grounded.
WARNING: Each power supply circuit must be provided with a means of disconnection, and the disconnecting means must be grouped.
WALL-MOUNTED INSTALLATION
WARNING: Observe minimum clearances shown in chart above.
1. Securely fasten the L-shaped brackets to the
the short part of the bracket. NOTE: Wall bolts are not supplied: select an appropriate size to provide adequate support for the weight of the unit and taking into consideration any wind load conditions.
CAUTION: If there is any question about security
-
tractor.
2. Mount the heater to the brackets with the terminal box at the bottom of the heater.
3. Adjust the heater to the desired directional angle,
bolts on the brackets at the rear of the heater.
CAUTION: Do not position the heater at an angle greater than 50° or less than 30°.
INTRODUCTION
Heat Controller’s infrared heater produces radiant heat that warms people and objects rather than the air surrounding them. The heater can be mounted on a wall or ceiling, and adjustable brackets allow the heat to be directed where desired.
This heater is designed for outdoor commercial use only.
MINIMUM CLEARANCE DISTANCES FROM...
MODEL FLOOR CEILING
ADJACENT
WALLS
IR30S 8' (2.44 m) 1' 8" (.51 m) 36" (.91 m)
IR60S 10' (3.05 m) 1' 8" (.51 m) 48" (1.22 m)
Installation & Operation Radiant Infrared Heater
4. Secure the electrical supply cable so it does not come in contact with the heater body or obstruct the air vents. Follow local and national electrical code requirements.
CEILING-MOUNTED INSTALLATION
WARNING: Observe minimum clearances shown in chart at left.
1.
­ing brackets (not supplied). Select brackets that will maintain a minimum clearance of 1' 8" (.51 m) from the ceiling.
2. appropriate size to provide adequate support for the weight of the unit and any additional load resulting from wind conditions.
CAUTION: If there is any question about secu-
contractor.
3. Secure the heater to the mounting brackets with the heater facing directly down.
4. Secure the electrical supply cable so it does not come in contact with the heater body or obstruct the air vents. Follow local NEC code require­ments.
ADJUSTING DIRECTIONAL POSITIONING
WARNING! Never attempt to move heater while it is operating. Personal injury could result.
1. Power to the heater from the main supply must
be OFF to adjust the position. (Turn off circuit breaker.)
2. Allow the heater to cool completely, before re-
positioning the angle.
3.
rear of the heater; re-position heater as desired,
CAUTION: Do not position the heater at an angle
greater than 50° or less than 30°.
3
AITONS EQUIPMENT