The rounded design of the FCA unit allows either under ceiling or floor-level installation. Under
ceiling installation frees up wall and floor space, while floor-level installation helps prevent the loss
of warm air.
SLIM AND ATTRACTIVE DESIGN
New fashionable appearance and light weight structure.
LOW NOISE OPERATION
The unit not only does it has ultra quiet multi-speed motor and a tangential blower wheel for
optimum sound.
3D SWING FUNCTION FOR BETTER COMFORT
The horizontal and vertical air sweep combination allows three-dimensional control of the air
direction.
LED ERROR DISPLAY FOR TROUBLESHOOTING
Easy to read LED display for 6 error diagnostics.
IR REMOTE HANDSET OPERATION
User friendly control platform with functions in Cooling, Dehumidifying, Heating, Fan, Auto, auto
control sleep mode, 24hrs ON/OFF timer, etc.
4
REFERENCE CARD
Write the model and serial numbers here which you can find them on a
label on the side of each unit:
Model Number: _______________________________
Serial Number: _______________________________
Dealer’s Name: _______________________________
Dealer’s Tel: _______________________________
Date Purchased: _______________________________
Staple your receipt to this page in the event you need it to prove date
of purchase or for warranty issues.
5
READ THIS MANUAL
Manual x 1
Spring washer x 4
High pressure
Insulated hose x 1
Remote Control x 1
Washer x 4
Low pressure
Insulated hose x 1
AAA battery x 2
Bolt x 4
Grille x 1
Electric drill
Adjustable wrench
Level gauge
Refrigerant gas leak detector
Screw driver
vacuum pump
Torque wrench
Gauge manifold
Inside you will find many helpful hints on how to install and use your air
conditioner properly. Just a little preventive care on your part can save
you a great deal of time and money over the life of your air conditioner.
You will find many answers to common problems in the troubleshooting
table. If you review our chart of TROUBLESHOOTING first, you may not
need to call for service at all.
Warning
1. Disconnect from the main before servicing this appliance.
2. Do not repair by yourself. In case of malfunction of this appliance, do
not repair by yourself. Contact the sales dealer or service dealer for a
repair.
3. Turn off the power (isolation from main power supply). Switch off the
breaker, or switch off the power disconnecting means to isolate the
equipment from the main power supply in case of an emergency.
INSTALLATION ACCESSORIES PROVIDED
INSTALLATION REQUIRED TOOLS
6
SAFETY PRECAUTIONS
Before operating, please read the following “SafetyPrecautions”
carefully.
To prevent personal injury, injury to others and property damage, the
following instructions must be followed.
Incorrect operation due to failure to follow instructions will cause harm
or damage, the seriousness of which is classified as follow:
WarningThis sign indicates the possibility of death or serious injury.
Caution This sign indicates the possibility of injury or damage to property.
The instructions to be followed are classified by the following symbols:
This symbol denotes an action that is PROHIBITED.
This symbol denotes actions that are COMPULSORY.
7
INSTALLATION PRECAUTIONS
Warning
Do not install, remove and reinstall the unit by yourself.
Improper installation will cause leakage, electric shock or fire. Please engage an authorized
Dealer or specialist for the installation work.
Caution
This room air conditioner must be earthed.
Improper grounding could cause electric shock.
Ensure that the drainage piping is connected properly.
Otherwise, water will leak out.
Do not install the unit in a potentially explosive atmosphere.
Gas leak near the unit could cause fire.
OPERATION PRECAUTIONS
Warning
Do not operate with wet hands.
This may cause an electric shock.
Do not insert finger or other objects into the indoor unit.
Since the fan rotates at high speed, this may cause an injury.
Do not expose directly to cold air for a long period of time.
This could damage your health.
Do not turn the breaker off/on during operation.
This may cause a fire due to spark, etc.
Be sure to turn off the breaker absolutely after switching the indoor unit off with the
remote controller.
8
Use specified power cord.
If abnormal condition (burnt smell, etc) occurs, switch off the
power supply.
Caution
Do not wash the unit with water.
Do not put a vase or glass on the indoor unit.
Do not use for other purpose such as preservation.
Do not use any combustible equipment at airflow direction.
Do not stop the operating unit by pulling out the power supply
line.
Do not operate the unit for a long time in high humidity, e.g.
leaving a door or window open.
In the cooling mode, if the unit is operated in a room with highhumidity (80%RH or
more) for a long time, water condensed in the air conditioner may drop and wet or
damage furniture, etc.
Do not charge or disassemble the batteries and do not throw
them into a fire.
This may result in leakage, fire or an explosion.
Switch off the power supply before cleaning.
Ventilate the room regularly.
Pay attention as to whether the installation rack is damaged
after a long period of usage.
Switch off the power supply if the unit is not used for a long
period.
Replace the 2 batteries with new ones of same type.
Using an old battery together with a new one may result in heat generation, leakage
or an explosion.
If liquid from the alkaline batteries gets onto your skin or
clothes, wash it well with clean water.
If liquid from the alkaline batteries gets into your eyes, wash them well with clean
water and consult a doctor at once.
9
INSTALLATION, START-UP AND SERVICE
INSTRUCTIONS FOR FCA INDOOR UNIT
SAFETY CONSIDERATIONS
1. Installation and servicing of air conditioning equipment can be hazardous due to system
pressure and electrical components. Only trained and qualified personnel should service
equipment.
2. When working on air conditioning equipment observe precautions in the literature and
labels attached to the unit and other safety precautions that may apply. Follow all safety
codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations.
Have a fire extinguisher available for all brazing operations.
WARNING!
Before performing service or maintenance operations on the system, turn off the
main power switches to the unit. Electrical shock could cause personal injury.
INSTALLATION INITIAL CHECK
1. The carton should not be removed from unit until reaching final location to avoid damage.
2. Inspect unit for shipping damage and file a claim with the transport agency if necessary.
3. Check field electrical works:
a. Proper size of fuses and wire, correct wiring connections and grounding as specified
by the local electrical codes.
b. Also check supply voltage. This must be within the limits shown on the rating plate.
4. Check for a proper condensate flow.
5. Be sure piping insulation is adequate.
6. Confirm there are no obstructions to air flow for the unit. Also check for sufficient
clearances for servicing of the unit.
SELECTION OF THE INSTALLATION LOCATION
1. Unit should be installed in a proper location to avoid blind sector, as shown in Fig. 1.
2. There should not be any heat source of steam near the unit.
3. There should not be any obstacles to prevent the air circulation.
4. A place where air circulation in the room will be good.
5. A place where noise prevention is taken into consideration.
6. Ensure the spaces indicated by arrow from the wall, ceiling, fence, or other obstacles.
7. Do not install the unit near the door way.
8. Do not install the unit near a fire alarm.
9. Do not install the unit in a machinery shop or kitchen where oil vapour flows into the unit.
The oil will deposit on the heat exchanger, thereby reducing the unit performance. In the
worse case it may deform or break the plastic parts of the units. It is recommended that the
standard filter be replaced with a special filter if necessary.