Service Bulletin-11 | Vacuum Capacitors
X-Ray Radiation experienced
with Vacuum Capacitors
Comet AG Service Bulletin-11 | Vacuum Capacitors
Herrengasse 10 | CH-3137 Flamatt X-Ray Radiation experienced with Vacuum Capacitors
T +41 31 744 95 00 | pct@comet.tech Issue date: 01-JUN-2011
pct.comet.tech Page 1 of 3 Replaces: 10-AUG-1994

All high voltage devices operating higher than 10 kV produce X-rays. The radiation level increases as the voltage
is increased.
For a vacuum capacitor of ceramic-metal construction the radiation becomes of concern once the peak voltages
exceed 15 kV. It is therefore necessary to provide adequate shielding based on measurements and in accordance with the local laws covering X-ray radiation. Under normal circumstances the equipment manufacturer
takes the necessary precautionary measures.
We have an entirely different picture when the capacitor is tested with a tester providing no shielding like the
COMET HV-75 or similar old generation units. At the time these devices were designed, the laws covering permissible radiation levels were less stringent. For instance, it was deemed adequate to point out that these tests
be performed by qualified, trained personnel only and that the distance between the test object to the test operator be at least 150 cm. Re-evaluating these old procedures with an end of life capacitor, having especially high
leakage current, we were able to confirm that the procedures are safe if followed. The data obtained were
0.1 mR/hr (~ 1 µGy/hr). New standards known to us are:
American MIL 454F giving a max. reading of 2.0 mR/hr in 5 cm distance from outer surface of equipment.
American OSHA allows 2.4 mR/hr in 5 cm distance.
US National Council of Radiation Protection allows 5.7 mR/H in 5 cm distance.
We know that there are different standards in other countries. It is therefore strongly recommended that each
user of a HV-tester follows the applicable local laws.
If one considers the fact that X-ray radiation is present with an AC test it will be worse under DC conditions.
COMET has taken this into account when designing the new HV-tester, the HV 100-30 and HV 60-50. Not only is
the design such that no high voltage lead or terminal can be touched during operating, but also adequate shielding is provided with respect to X-ray radiation during testing and spot-knocking operations.
Comet AG Service Bulletin-11 | Vacuum Capacitors
Herrengasse 10 | CH-3137 Flamatt X-Ray Radiation experienced with Vacuum Capacitors
T +41 31 744 95 00 | pct@comet.tech Issue date: 01-JUN-2011
pct.comet.tech Page 2 of 3 Replaces: 10-AUG-1994

Switzerland (Head Office)
Led by experience. Driven by curiosity.
Comet AG
Herrengasse 10
CH-3175 Flamatt
T +41 31 744 95 00
United States
Comet Technologies USA, Inc.
541 E. Trimble Road
San José, CA 95131
T +1 408 325 8770
China
Comet Mechanical Equipment (Shanghai) Co. Ltd.
2777 East Jinxiu Road
Building 36, 8th floor
Pudong, Shanghai 201206
T +86 21 6879 9000
Germany
Comet Yxlon GmbH
Plasma Control Technologies
Kellershaustrasse 22
DE-52078 Aachen
T +49 241 936 87 00
Comet Technologies Korea Co., Ltd.
Suwon Venture Plaza Bldg, Room 402
48, Samsung-ro, 168 beon-gil, Yeongtong-gu
Suwon-si, Gyeonggi-do, ZIP 16676
T +82 (0)70 4337 6480
Malaysia
Comet Technologies Malaysia Sdn Bhd
PMT 761 Persiaran Cassie Selatan 3
Taman Perindustrian Batu Kawan
14110 Bandar Cassia
Penang
T +604 588 6516
Taiwan
Comet Solutions Taiwan Ltd.
1F., No. 120, Guangming Rd.
Qionglin Township
Hsinchu County 307001
T +886 3 592 2398
pct.comet.tech
Comet AG Service Bulletin-11 | Vacuum Capacitors
Herrengasse 10 | CH-3137 Flamatt X-Ray Radiation experienced with Vacuum Capacitors
T +41 31 744 95 00 | pct@comet.tech Issue date: 01-JUN-2011
pct.comet.tech Page 3 of 3 Replaces: 10-AUG-1994
E-mail pct@comet.tech