Comed HF 525 Technical Description

Page 1
Technical Description
Compact Examination System
For Radiography
EVA - HF 525
Page 2
medicalECONET GmbH Mainstrasse 6c-d D-45768 Marl / Germany
X
-
R
a
y
C
o
n
s
o
l
e
H
F
-
5
2
5
X
-
R
a
y
C
o
n
s
o
l
e
H
F
-
X
-
R
a
y
C
o
n
s
o
l
e
EVA Series are controlled by Digital key panel console that displays KV, mA and mAs with APR meuu programmed. System-self-diagnosis and self –diagnostic circuitry standard on each unit. Equpped with closed loop for X-ray tube current as well as kVp, minimizing potential errors and need for re-adjustments.
H
F
5
-
5
2
2
5
5
2
Page 3
medicalECONET GmbH Mainstrasse 6c-d D-45768 Marl / Germany
X
-
R
a
y
G
e
n
e
r
a
t
o
r
H
F
-
5
2
5
X
-
R
a
y
G
e
n
e
r
a
t
o
r
H
F
-
X
-
R
a
y
G
e
n
e
r
a
t
o
r
Microprocessor controlled high frequency generator for all examinations in the area of the X- ray diagnostics, prepared for special applications. The automatic exposure control (AEC) is integrated. This generator features by a very compact design and can be integrated in the base of the examination table as a space saving compact solution.
The foil coated control desk enables easy operation and hygienic possibilities for cleaning as well as easy operation for the user. In the anatomical program operating mode can be stored programs individually.
An internal self-diagnosis centre monitors the X-ray unit and indicates errors on the screen. So the generator is optimal protected against malfunctions.
T
e
c
h
n
i
c
a
l
D
a
t
a
T
e
c
h
n
i
c
a
T
e
c
Power output at 100 kV / 0,1 s 40 kW Converter 40 kHz Exposure techniques * kV-mAs
(alternatively with Automatic Exposure Control) * kV-mA-ms
* anatomical program mode
l
h
n
i
c
a
D
a
t
a
l
D
a
t
a
H
F
5
-
5
2
2
5
5
(Generator, installed in the table)
3
Page 4
medicalECONET GmbH Mainstrasse 6c-d D-45768 Marl / Germany
Radiography
kV range 40 ... 125 kV in 1 kV steps
mA range 25 ... 500 mA
mAs range 0,2 ... 600 mAs in 42 steps
minimal exposure time 2 ms (with and without AEC)
Periphery
X-ray tube connections 1 Max. workstations 3 Programmable film screen systems (AEC) 1 Type of AEC measuring chambers ionisation chambers
4
Page 5
medicalECONET GmbH Mainstrasse 6c-d D-45768 Marl / Germany
X
-
R
a
y
T
u
b
e
T
O
S
H
I
B
A
E
7
2
5
2
X
X
-
R
a
y
T
u
b
e
T
O
S
H
I
B
A
E
7
2
X
-
R
a
y
T
u
b
e
T
O
S
H
I
B
A
State 2004-03. Subjects to change.
The E 7252X is a double-focus rotating anode X-ray tube which is designed for general radiographic procedures, according to the generators power data.
T
e
c
h
n
i
c
a
l
D
a
t
a
T
e
c
h
n
i
c
a
l
T
e
c
h
Maximal voltage 150 kV 125kV
Nominal power small focus 16 kW 21kW large focus 44 kW 45kW Focal spot dimensions small focus 0,6 x 0,6 mm 1.0x1.0mm large focus 1,2 x 1,2 mm 2.0x2.0mm
Anode material Tungsten, Rhenium, Tunstein, Rhenium. Target angel 12° 16° Rotating anode speed 2.700 rpm (50 Hz) 2,700rpm(50Hz)
Anode heat storage capacity 300 kHU = 212 kJ 140kHU=100kJ Tube assembly heat storage capacity 1.250 kHU = 900 kJ ­Max. heat dissipation of the tube assembly 15 kHU/min = 177 W -
Inherent filtration of tube and housing 0,7 mm Al -
D
n
i
c
a
l
D
a
t
a
a
t
a
E
5
7
2
5
2
2
X
X
E
7
2
3
9
X
o
r
r
E
7
o
o
r
E
7
E
7
E
7
2
E
7
2
2
5
2
X
2
5
2
X
2
5
2
X
3
3
9
9
X
X
E
E
E
7
2
7
2
7
3
9
X
3
9
X
2
3
9
X
5
Page 6
medicalECONET GmbH Mainstrasse 6c-d D-45768 Marl / Germany
Examination table with Bucky wall stand
6
Page 7
medicalECONET GmbH Mainstrasse 6c-d D-45768 Marl / Germany
E
x
a
m
i
n
a
t
i
o
n
P
l
a
c
e
E
V
A
E
x
a
m
i
n
a
t
i
o
n
P
l
a
c
e
E
x
a
m
i
n
a
t
i
o
n
P
State 2004-04. Subjects to change.
The radiographic examination unit EVA featured by an optimised construction which permits to realise a multitude of examinations on a minimised room. The table is prepared to integrate a special X-ray generator into the base. The complete system can be installed quickly and simple without additional special construction works.
The examination table is composed of a Bucky table with floating patient table top and an integrated column which supports the tube assembly, collimator and the control board. The column doesn’t need any additional fixing elements.
The arm which supports the tube and the control board permits the rotation of the radiogen system on the axe of the arm itself and enable to realise special positions with different angles of incidence as well as the operating of a Bucky wall stand. The vertical movement of the radiogen system is balanced by counterweights. The transversal displacement of the tube as well as the rotation of the column is standard All movements of the column and the table top are stopped by electromagnetic brakes.
The top panel of the Bucky table is in radio transparent laminated plastic with longitudinal profiles in extruded aluminium and lateral guides of insertion and anchorage of the accessories of common use. The movements of the table top are stopped by electromagnetic brakes which are active in the absence of power. They keep it in a defined position as well the installation is off.
The Bucky diaphragms of the table as well as the wall stand can be equipped with AEC ionisation measurement chambers.
T
e
c
h
n
i
c
a
l
D
a
t
a
T
e
c
h
n
i
c
a
l
T
e
c
h
Bucky table
Table top material grey-white colour laminated plastic Absorption approx. 0,9 mm Al-GW Dimensions 200 x 74 cm Longitudinal travel 60 cm (± 30 cm) Transversal travel 16 cm (± 8 cm) Table top upper edge to film distance 7,5 cm Table top distance to the floor 70 cm
Bucky carriage longitudinal travel 38 cm Grid 12:1, 36 L/cm, foc 110 cm
Acoustical signalling of the table’s central position.
n
i
c
a
l
D
D
a
t
a
a
t
a
E
l
a
c
e
E
V
V
A
A
7
Page 8
medicalECONET GmbH Mainstrasse 6c-d D-45768 Marl / Germany
The cassette tray is supported in a telescopic roller guide
Tube stand
Longitudinal displacement travel 185 cm Column rotation around the vertical axis ± 90° Min. focus distance to the floor (90°-Position) 73 cm Vertical travel 113 cm Max. FFD 120 cm Tube rotation around the horizontal axis ± 90° Transversal displacement travel of the tube 14 cm (± 7 cm)
8
Page 9
medicalECONET GmbH Mainstrasse 6c-d D-45768 Marl / Germany
Collimator with dose area product measurement chamber
Collimator
Type of command manual Localisation light 24 V / 150 W Halogen with electronic timer Inherent filtration 1,5 mm Al-GW
Equipped with a rotating collar
Bucky wall stand
Vertical displacement travel 120 cm Min. distance film centre line to the floor 40 cm Distance table top to film 5,5 cm Grid 12:1, 36 L/cm, foc 100 cm
Vertical movement controlleded by electromagnetic brakes.
9
Page 10
medicalECONET GmbH Mainstrasse 6c-d D-45768 Marl / Germany
Electrical requirements
Mains connection 3x 400 V, 50 Hz + 6% / -10%
Option: Single phase supply with battery Fuse 3x 35 A delayed Line impedance max. 0,3 Ω Nominal power input 23 kVA Short time pulse max. 68 kVA Stand-by 120 W
Weights and dimensions
Bucky table with tube stand kg
Generator built-in into the Examination table kg
Control desk 230 x 410 x 80 mm 5 kg
Required space
You need an area of about 2,5 x 4 m.
Certification
CE Certificate L-0243314-02 EN ISO 9002:1994 / EN 46002:1996
10
Loading...