Comba Telecom TS-19-12XXXXXX User Manual

MCPA TBS SYSTEM USER MANUAL
SYSTEM
User Manual
Let Communication Be Available
May 2009
ENU:1-0-0 Copyright Comba Telecom Ltd., March 2009. All rights reserved Page1-1
MCPA TBS SYSTEM USER MANUAL
COPYRIGHT DECLARATIONS
This is an unpublished work the copyright in which vests in Comba Telecom Ltd. ("Comba").
All rights reserved. The information contained herein is confidential and the property of Comba
and is supplied without liability for errors or omissions. No part may be reproduced, disclosed
or used except as authorised by contract or other written permission. The copyright and the
foregoing restriction on reproduction and use extend to all media in which the information may
be embodied.
ENU:1-0-0 Copyright Comba Telecom Ltd., March 2009. All rights reserved Page1-2
MCPA TBS SYSTEM USER MANUAL
FCC COMPLIIANCE
z This device complies with Part 15 of the FCC Rules. Operation is subject to the condition
that this device does not cause harmful interference.
z Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
z NOTE: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
z To comply with FCC RF exposure requirements, the device and the antenna for this
device must be installed to ensure a minimum separation distance of 15.81 metres or more from a person's body. Other operating configurations should be avoided.
ENU:1-0-0 Copyright Comba Telecom Ltd., March 2009. All rights reserved Page1-3
MCPA TBS SYSTEM USER MANUAL
ABOUT THIS DOCUMENT
Purpose of this document
This document provides training and guide for the installation of Comba MCPA TBS system.
Reader of this document
This document will be used and read by operator who will or is going to do Comba MCPA TBS
system installation or for people who will or is going to do site service, such as commissioning,
maintenance, troubleshooting, etc.
Contents of this document
This document consists of system introduction, system installation and system initial startup. In
system installation, it includes the site preparation, installation instruction of each module, and
all kinds of cable connection.
Suggestion for this document
Whilst every endeavor is made to ensure the accuracy of this and all Comba documents, there
is always the possibility that an inaccuracy or omission could occur. In order that any
amendment/remedial action can be carried out promptly, we would appreciate your
co–operation in filling out and returning a photocopy of this customer reply sheet as soon as
possible. Please refer to Appendix A.
ENU:1-0-0 Copyright Comba Telecom Ltd., March 2009. All rights reserved Page1-4
MCPA TBS SYSTEM USER MANUAL
CONTENTS
Section Page
COPYRIGHT DECLARATIONS ............................................................................................................. 1-1
COPYRIGHT DECLARATIONS ............................................................................................................. 1-2
FCC COMPLIIANCE .............................................................................................................................. 1-3
ABOUT THIS DOCUMENT .................................................................................................................... 1-4
CONTENTS 1-5
ISSUE CONTROL .................................................................................................................................. 1-6
ISSUE CONTROL .................................................................................................................................. 1-6
0.1 SAFETY LABELLING......................................................................................................... 1-7
0.2 IMPORTANT SAFETY NOTICE ........................................................................................ 1-8
1 SYSTEM INTRODUCTION.............................................................................................. 1-11
1.1 PURPOSE OF MCPA TBS SYSTEM .............................................................................. 1-12
1.2 MODELS COMPLIANCE ................................................................................................. 1-13
2 SYSTEM INSTALLATION................................................................................................ 2-15
2.1 GERNERAL INTRODUCTION......................................................................................... 2-15
2.2 INSTALLATION SITE REQUIREMENT........................................................................... 2-16
2.3 POWER SUPPLY REQUIREMENT................................................................................. 2-17
2.3.1 TEMPERATURE AND HUMIDITY REQUIREMENT ....................................................... 2-17
2.3.2 UNPACKING AND INSPECTION .................................................................................... 2-19
2.3.3 INSTALLATION TOOLS REQUIREMENT....................................................................... 2-20
3 SYSTEM POWER ON AND OFF .................................................................................... 3-21
3.1 CONTROLS AND INDICATORS ..................................................................................... 3-22
3.1.1 MCPA CONTROL AND INDICATOR............................................................................... 3-22
3.1.2 CONTROL MODULE CONTROL AND INDICATORS .................................................... 3-23
3.2 SYSTEM DC POWER ON AND OFF PROCEDURES.................................................... 3-24
4 APPENDICES .................................................................................................................. 4-26
4.1 APPENDIX A: SUGGESTION FOR THE DOCUMENT................................................... 4-26
4.2 APPENDIX B: SERVICE POLICY AND RETURN OF EQUIPMENT .............................. 4-27
4.3 APPENDIX C: RMA (RETURN MATERIAL AUTHORIZATION) FORM ......................... 4-29
ENU:1-0-0 Copyright Comba Telecom Ltd., March 2009. All rights reserved Page1-5
MCPA TBS SYSTEM USER MANUAL
ISSUE CONTROL
Change No. ENU Date of Change Details Of Change
1 0-0-1 March 2009 Initial Draft
2 1-0-0 March 2009 Original Issue.
ENU:1-0-0 Copyright Comba Telecom Ltd., March 2009. All rights reserved Page1-6
MCPA TBS SYSTEM USER MANUAL
0.1 SAFETY LABELLING
This document contains safety and note labels in accordance with appropriate standards as
following:
DANGER
WARNING
CAUTION
In the interests of conformity with the territory standards for the country concerned, the
equivalent territorial admonishments are also shown.
DANGER
These draw the attention of personnel to hazards which will cause death or severe injury to the
operator or others. Examples of use are cases of high voltage, radiation emission, toxic
substances, point of high temperature, etc. The format is as following:
Text describing the hazards conditions/damage, and instructions for proper
DANGER
WARNING
These draw the attention of personnel to hazards which can cause death or severe injury to
the operator or others. The format is as following:
operation
Text describing the hazards conditions/damage, and instructions for proper
WARNING
CAUTION
These draw attention to hazards which may cause minor personal injury, or cause damage to
the equipment where there is a possibility of property loss or seriously impairing its
performance. The format is as following:
CAUTION
operation
Text describing the matters where that have possibility of minor injury or
property loss or impairing equipment performance, and instruction for proper
operation
ENU:1-0-0 Copyright Comba Telecom Ltd., March 2009. All rights reserved Page1-7
MCPA TBS SYSTEM USER MANUAL
0.2 IMPORTANT SAFETY NOTICE
Before the installation, please read this section carefully and follow on all detailed safety instructions. A safe and successful installation relies on your careful reading a nd following.
1. GENERAL SAFETY INSTRUCTIONS
Follow on following instruction can avoid severe injury or critical damage to the
equipment:
DANGER
WARNING
z Before the installation or system operation, review the hazards which could
occur during mechanical installation, RF and electricity connections.
z The rack or outdoor cabinet is setup at a flat ground or platform.
z Do not force to install equipment onto the rack or cabinet which can’t
support its weight.
z Do not do any operation for TBS system when your hands are wet.
z Do not do cleaning for equipment with wet cloth, liquid cleaner, solvent or
aerosol cleaner.
z In order to avoid electrical shock, do not recover circuit packs or touch DC
terminals without any protection.
z In order to avoid strong radiation, please switch off the RF input from BTS.
Before startup TBS system, RF input cables and RF output feeder lines are
properly connected to Passive Module.
z Check the voltage and current request and do not connect the wrong
voltage power source.
z Check the power cable requirement for right voltage and current.
z Do not do power connection before main breaker is still on.
z Do not expose the equipment to liquid, moisture, or oily or water vapor of
any kind, under any conditions.
z Do not put your hands into the running blade of cooling fans.
Follow on following instruction can avoid and eliminate the possibility for
personal severe injury or damage to equipment:
z Read and review the site preparation and assure good ventilation for heat
dissipation.
z Avoid to knock at some hard things and hurt your body, make sure the
move direction and sight is clear when move equipment,
z Have enough support or lift capability when do mechanical installation
which is beyond one person’s ability.
z Check the labels carefully and install the right modules in right system.
z Do not expose the equipment to direct sunlight or a high temperature
place.
z Install blank panel for empty slots.
z Do not put hands or other things into empty slots.
z Do not place other things on the top of equipment.
ENU:1-0-0 Copyright Comba Telecom Ltd., March 2009. All rights reserved Page1-8
MCPA TBS SYSTEM USER MANUAL
z Do not slam modules into Subrack or rack directly.
z Switch off circuit breaker or disconnect power supply when do operation
z Use profession installation tools to do mechanical installation RF and
power connection.
z Check whole equipment is well grounded before startup.
Follow on following instruction can avoid and eliminate the possibility for
personal minor injury or damage to equipment :
z Please make sure you have got professional training and you understand
CAUTION
the procedures clearly. Otherwise you need professional technician site
support.
z Do not start installation when you find the equipment package is damaged,
please contact forwarder.
z Do not start installation when you find some components/materials are
missing, please contact forwarder.
z Make sure installation tools are all available and properly.
z Do not place any magnet or magnetic static material near to equipment.
z Do not tear the seals on equipment which is still in warranty period.
2. SITE SERVICE REQUEST
When site service request includes the activities as following:
Equipment need to move
Alarm or fault can’t be solved and need troubleshooting
Equipment can’t work and need troubleshooting
Water leakage into equipment
Equipment damage (such as drop or fall)
Equipment maintenance, such as cleaning, visual inspection, RF and power cable
connection checking, etc
Module replacement
Please contact with field engineer or Comba local office (Appendix B) for site service. Only
personnel who have been professionally trained and authorized can provide the service. And
please follow on following instructions for site service.
z Before operation, please read the general safety instructions and make
WARNING
sure you know the hazards and understand the working procedures.
z Do not remove covers of any circuit pack or modules. Only personnel
who have been professionally trained and authorized.
z Do not disassemble modules and cable connections. Only personnel
who have been professionally trained and authorized can do it.
z Do not do cleaning for equipment with wet cloth, liquid cleaner, solvent or
aerosol cleaner. For dust or dirt accumulation on air vents or filters, use
compressed air or a brush with soft bristles to loosen and remove it. And
ENU:1-0-0 Copyright Comba Telecom Ltd., March 2009. All rights reserved Page1-9
Loading...